• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Viscosity and Density of Reference Fluid

Almotari, Masaed Moti M January 2006 (has links)
The viscosity and density of bis(8-methylnonyl) benzene-1,2- dicarboxylate {diisodecyl phthalate (DIDP)}, with a nominal viscosity at T = 298 K and p = 0.1 MPa of 87 mPa•s, have been measured at temperatures from (298.15 to 423.15) K and pressures from (0.1 to 70) MPa. A vibrating wire viscometer, with a wire diameter of about 0.15 mm, was utilised for the viscosity measurements and the results have an expanded uncertainty, (k = 2), including the error arising from the pressure measurement, of between ±(2 and 2.5) % The density was determined with two vibrating tube densimeters one for operation at p≈0.1 MPa with an expanded uncertainty (k = 2) of about ±0.1 %, the other that used at pressures up to 70 MPa, with an estimated expanded uncertainty (k = 2) of about ±0.3 %. Measurements of density and viscosity were performed on three samples of DIDP each with different purity stated by the supplier and as a function of water mass fraction. The measured viscosity and density are represented by interpolating expressions with differences between the experimental and calculated values that are comparable with the expanded (k = 2) uncertainties. The obtained viscosities at p = 0.1 MPa agree with values reported in the literature within the combined expanded (k = 2) uncertainties of the measurements while our densities differ by no more than 1.5 %. Viscosity data at p > 0.1 MPa deviate systematically from the literature values in the range of -10 % to 10 %. An apparatus capable of simultaneously measuring the solubility of a gas dissolved in a liquid and the viscosity and the density of the resulting mixture over a wide temperature and pressure range was constructed and tested. Preliminary results have been reported.
2

Viscosity and Density of Reference Fluid

Almotari, Masaed Moti M January 2006 (has links)
The viscosity and density of bis(8-methylnonyl) benzene-1,2- dicarboxylate {diisodecyl phthalate (DIDP)}, with a nominal viscosity at T = 298 K and p = 0.1 MPa of 87 mPa•s, have been measured at temperatures from (298.15 to 423.15) K and pressures from (0.1 to 70) MPa. A vibrating wire viscometer, with a wire diameter of about 0.15 mm, was utilised for the viscosity measurements and the results have an expanded uncertainty, (k = 2), including the error arising from the pressure measurement, of between ±(2 and 2.5) % The density was determined with two vibrating tube densimeters one for operation at p≈0.1 MPa with an expanded uncertainty (k = 2) of about ±0.1 %, the other that used at pressures up to 70 MPa, with an estimated expanded uncertainty (k = 2) of about ±0.3 %. Measurements of density and viscosity were performed on three samples of DIDP each with different purity stated by the supplier and as a function of water mass fraction. The measured viscosity and density are represented by interpolating expressions with differences between the experimental and calculated values that are comparable with the expanded (k = 2) uncertainties. The obtained viscosities at p = 0.1 MPa agree with values reported in the literature within the combined expanded (k = 2) uncertainties of the measurements while our densities differ by no more than 1.5 %. Viscosity data at p > 0.1 MPa deviate systematically from the literature values in the range of -10 % to 10 %. An apparatus capable of simultaneously measuring the solubility of a gas dissolved in a liquid and the viscosity and the density of the resulting mixture over a wide temperature and pressure range was constructed and tested. Preliminary results have been reported.

Page generated in 0.071 seconds