• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de métodos para a determinação de Pb, Cd, Cr, Ni e Sb em cosméticos faciais por espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua empregando amostragem direta de sólidos / Development of methods for determination of Pb, Cd, Cr, Ni and Sb in facial cosmetics by high-resolution continuum source graphite furnace atomic absorption spectrometry employing direct solid sampling

Barros, Ariane Isis [UNESP] 23 August 2016 (has links)
Submitted by ARIANE ISIS BARROS null (nane_isis@hotmail.com) on 2016-09-02T15:26:47Z No. of bitstreams: 1 versão finalCD.pdf: 2759107 bytes, checksum: a6bb24a7b9f0540265cbb13f22e1d798 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-09-06T14:04:39Z (GMT) No. of bitstreams: 1 barros_ai_dr_araiq.pdf: 2759107 bytes, checksum: a6bb24a7b9f0540265cbb13f22e1d798 (MD5) / Made available in DSpace on 2016-09-06T14:04:40Z (GMT). No. of bitstreams: 1 barros_ai_dr_araiq.pdf: 2759107 bytes, checksum: a6bb24a7b9f0540265cbb13f22e1d798 (MD5) Previous issue date: 2016-08-23 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este trabalho relata o desenvolvimento de métodos para a determinação de Pb, Cd, Cr, Ni e Sb em cosméticos faciais por espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua (HR-CS GF AAS) empregando análise direta de amostras sólidas. Essa técnica foi utilizada devido a sua alta capacidade para a correção de fundo baseada em algoritmos dos mínimos quadrados. Para a determinação de Pb e Sb, interferências causadas por moléculas de SiO(g) nas linhas 283,306 nm (Pb), 217,582 nm (Sb) e 231,147 nm (Sb) foram eliminadas pela aplicação do método de correção de fundo pelos mínimos quadrados (LSBC). Para a correção de fundo na determinação de Pb, o espectro de referência foi gerado a partir de SiO2. Diferentes precursores foram avaliados para geração do espectro de referência para a correção de fundo na determinação de Sb, sendo a zeólita e a mica os precursores mais eficazes. Efeitos de matriz foram avaliados pela comparação das massas características e inclinações das curvas obtidas em padrões aquosos e amostras (ou material de referência certificado). Calibrações com padrões aquosos foram possíveis e curvas com bom coeficiente de correlação (r>0,99) foram obtidas para todos os analitos. Os limites de detecção foram de 0,06 mg kg -1 Pb, 3,67 µg kg-1 Cd, 0,5 mg kg-1 Cr, 0,292 mg kg-1 Ni e 0,32 mg kg-1 Sb. As concentrações dos analitos encontradas em amostras comerciais de blush, sombra de olho e pó compacto variaram de 1,0 – 27,08 mg kg-1 Pb, 5,06 – 198,20 µg kg-1 Cd, 2,87 – 23,65 mg kg-1 Cr, 1,36 – 12,09 mg kg-1 Ni e 9,14 – 14,52 mg kg-1 Sb. A exatidão foi checada pela análise de material de referência certificado (CRM) de solo, testes de adição e recuperação e/ou método comparativo. As concentrações encontradas no CRM foram concordantes com os valores certificados ao nível de 95% de confiança (teste t). Recuperações variaram de 99 – 108 % (Pb), 86 – 115 % (Cd), 105 – 115 % (Cr), 83 – 106 % (Ni) e 82 – 108 % (Sb). Os resultados para Cd e Pb determinados com os métodos propostos foram concordantes com os obtidos com os métodos comparativos, ao nível de 95% de confiança (teste t-pareado). / This work reports on the development of methods for determination of Pb, Cd, Cr, Ni and Sb in facial cosmetics by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) employing direct solid sample analysis. This technique was used due to the high capability for background correction based on least-squares algorithm. For Pb and Sb determinations, interferences caused by SiO(g) molecule at the lines 283.306 nm (Pb), 217.582 nm (Sb) and 231.147 nm (Sb) were eliminated by applying the least-squares background correction (LSBC). For background correction in the determination of Pb, a reference spectrum was generated from SiO2. Different precursors were evaluated to generate reference spectra for correction of the background in the determination of Sb, been zeolite and mica the most effective precursors. Matrix effects were evaluated by comparing the characteristics masses and slopes of curves in aqueous standards and sample (or certified reference material). Calibration with aqueous standards were possible, and curves with good correlation coefficients (r>0.99) were attained for all analytes. The limits of detection were 0.06 mg kg-1 Pb, 3.67 µg kg-1 Cd, 0.5 mg kg-1 Cr, 0.292 mg kg-1 Ni and 0.32 mg kg-1 Sb. The found concentrations of analytes in commercial blush, eye shadow and compact powder samples were within 1.0 – 27.08 mg kg-1 Pb, 5.06 – 198.20 µg kg-1 Cd, 2.87 – 23.65 mg kg-1 Cr, 1.36 – 12.09 mg kg-1 Ni, and 9.14 – 14.52 mg kg-1 Sb. Accuracy was checked by analyzing soil certified reference materials (CRM), addition and recovery tests and/or comparative method. The concentrations found in CRM were in agreement with certified values at a 95% confidence level (t-test). Recoveries were in the 99 – 108 % (Pb), 86 – 115 % (Cd), 105 – 115 % (Cr), 83 – 106 % (Ni) and 82 – 108 % (Sb) intervals. Results for Cd and Pb determined with the proposed method were in agreement with those obtained by the comparative method at a 95% confidence level (paired t-test). / CNPq: 47166/2012-8
2

Desenvolvimento de métodos analíticos para avaliação da presença de elementos essenciais e potencialmente tóxicos em fórmulas infantis

Gamela, Raimundo Rafael January 2017 (has links)
O consumo de fórmulas infantis no Brasil, utilizadas como substituto do leite materno, tem aumentado nos últimos anos de forma significativa. Tal fato é uma preocupação para os órgãos de saúde pois, o aleitamento materno exclusivo até no mínimo 6 meses, deixou de fazer parte de nutrição da maioria dos lactentes. Os produtos utilizados como substituto do leite materno contêm quantidades suficientes de vitaminas e nutrientes que ajudam no desenvolvimento normal do organismo dos lactentes. Entretanto, além de elementos essenciais, podem conter elementos potencialmente tóxicos presentes na matéria prima ou oriundos das etapas de processamento e armazenamento das mesmas. No presente trabalho foram desenvolvidos métodos analítico para determinar a presença de elementos potencialmente tóxicos (As, Cd, Pb e Tl) e essenciais (Cu e Mn) em fórmulas infantis, utilizando espectrometria de absorção atômica de alta resolução com fonte contínua e forno de grafite e análise direta de sólidos. As amostras utilizadas neste trabalho foram obtidas nos mercados da cidade de Porto Alegre, RS, Brasil, todas na forma sólida (pó) com diferentes composições e matéria prima (arroz, aveia, soja e leite). As curvas de calibração foram realizadas com soluções padrão aquosas e os métodos otimizados foram aplicados nas amostras em estudo. Em todas as amostras os elementos As, Cd, Pb e Tl apresentaram valores de concentração abaixo do limite de detecção. Das seis amostras analisadas, três apresentaram valores de concentração de Cu abaixo dos parâmetros mínimos estabelecidos pela legislação brasileira, enquanto que para o Mn todas amostras apresentaram valores de concentração dentro dos parâmetros mínimos da legislação brasileira. Os métodos desenvolvidos foram simples, exatos e precisos, podendo ser utilizados para análise de rotina. / The consumption of infant formula in Brazil, as a replacement of breast milk, has lately increased significantly. It is a major concern for health agencies because the exclusive breastfeeding up to at least 6 months is no longer part of most infants. The products used as a substitute of the breast milk contain sufficient amounts of vitamins and nutrients, which helps in the normal development of the infants. However, besides the essential elements, it may contain potentially toxic elements present in raw material or from of the processing and storage stages of the same. In the present work the presence of the essential (Cu e Mn) and potentially toxic elements (As, Cd, Pb e Tl) in infant formulas were evaluated. For this, analytical methods were developed for the determination of As, Cd, Cu, Mn, Pb and Tl using high-resolution continnum source graphite furnace atomic absorption spectrometry and direct solid sampling analysis in infant formulas. The samples were acquired in Porto Alegre’s market, RS, Brazil, all in powder form with different compositions and raw materials (rice, oats, soy and bovine milk). The calibration curves were performed with aqueous standard solutions and the optimized methods were applied in the study samples. In all samples, the concentration values of As, Pb, Cd and Tl were below of the limit of detection. For the analyzed samples, three of them present the concentration values of Cu lower than the minimum parameters established by Brazilian legislation, while for Mn, all samples present the concentration values within the minimum parameters of Brazilian legislation. The developed methods for the determination of these elements in infant formulas were simple, exacts and precise, and can be applicated for the routine analysis.
3

Desenvolvimento de métodos analíticos para avaliação da presença de elementos essenciais e potencialmente tóxicos em fórmulas infantis

Gamela, Raimundo Rafael January 2017 (has links)
O consumo de fórmulas infantis no Brasil, utilizadas como substituto do leite materno, tem aumentado nos últimos anos de forma significativa. Tal fato é uma preocupação para os órgãos de saúde pois, o aleitamento materno exclusivo até no mínimo 6 meses, deixou de fazer parte de nutrição da maioria dos lactentes. Os produtos utilizados como substituto do leite materno contêm quantidades suficientes de vitaminas e nutrientes que ajudam no desenvolvimento normal do organismo dos lactentes. Entretanto, além de elementos essenciais, podem conter elementos potencialmente tóxicos presentes na matéria prima ou oriundos das etapas de processamento e armazenamento das mesmas. No presente trabalho foram desenvolvidos métodos analítico para determinar a presença de elementos potencialmente tóxicos (As, Cd, Pb e Tl) e essenciais (Cu e Mn) em fórmulas infantis, utilizando espectrometria de absorção atômica de alta resolução com fonte contínua e forno de grafite e análise direta de sólidos. As amostras utilizadas neste trabalho foram obtidas nos mercados da cidade de Porto Alegre, RS, Brasil, todas na forma sólida (pó) com diferentes composições e matéria prima (arroz, aveia, soja e leite). As curvas de calibração foram realizadas com soluções padrão aquosas e os métodos otimizados foram aplicados nas amostras em estudo. Em todas as amostras os elementos As, Cd, Pb e Tl apresentaram valores de concentração abaixo do limite de detecção. Das seis amostras analisadas, três apresentaram valores de concentração de Cu abaixo dos parâmetros mínimos estabelecidos pela legislação brasileira, enquanto que para o Mn todas amostras apresentaram valores de concentração dentro dos parâmetros mínimos da legislação brasileira. Os métodos desenvolvidos foram simples, exatos e precisos, podendo ser utilizados para análise de rotina. / The consumption of infant formula in Brazil, as a replacement of breast milk, has lately increased significantly. It is a major concern for health agencies because the exclusive breastfeeding up to at least 6 months is no longer part of most infants. The products used as a substitute of the breast milk contain sufficient amounts of vitamins and nutrients, which helps in the normal development of the infants. However, besides the essential elements, it may contain potentially toxic elements present in raw material or from of the processing and storage stages of the same. In the present work the presence of the essential (Cu e Mn) and potentially toxic elements (As, Cd, Pb e Tl) in infant formulas were evaluated. For this, analytical methods were developed for the determination of As, Cd, Cu, Mn, Pb and Tl using high-resolution continnum source graphite furnace atomic absorption spectrometry and direct solid sampling analysis in infant formulas. The samples were acquired in Porto Alegre’s market, RS, Brazil, all in powder form with different compositions and raw materials (rice, oats, soy and bovine milk). The calibration curves were performed with aqueous standard solutions and the optimized methods were applied in the study samples. In all samples, the concentration values of As, Pb, Cd and Tl were below of the limit of detection. For the analyzed samples, three of them present the concentration values of Cu lower than the minimum parameters established by Brazilian legislation, while for Mn, all samples present the concentration values within the minimum parameters of Brazilian legislation. The developed methods for the determination of these elements in infant formulas were simple, exacts and precise, and can be applicated for the routine analysis.
4

Desenvolvimento de métodos analíticos para avaliação da presença de elementos essenciais e potencialmente tóxicos em fórmulas infantis

Gamela, Raimundo Rafael January 2017 (has links)
O consumo de fórmulas infantis no Brasil, utilizadas como substituto do leite materno, tem aumentado nos últimos anos de forma significativa. Tal fato é uma preocupação para os órgãos de saúde pois, o aleitamento materno exclusivo até no mínimo 6 meses, deixou de fazer parte de nutrição da maioria dos lactentes. Os produtos utilizados como substituto do leite materno contêm quantidades suficientes de vitaminas e nutrientes que ajudam no desenvolvimento normal do organismo dos lactentes. Entretanto, além de elementos essenciais, podem conter elementos potencialmente tóxicos presentes na matéria prima ou oriundos das etapas de processamento e armazenamento das mesmas. No presente trabalho foram desenvolvidos métodos analítico para determinar a presença de elementos potencialmente tóxicos (As, Cd, Pb e Tl) e essenciais (Cu e Mn) em fórmulas infantis, utilizando espectrometria de absorção atômica de alta resolução com fonte contínua e forno de grafite e análise direta de sólidos. As amostras utilizadas neste trabalho foram obtidas nos mercados da cidade de Porto Alegre, RS, Brasil, todas na forma sólida (pó) com diferentes composições e matéria prima (arroz, aveia, soja e leite). As curvas de calibração foram realizadas com soluções padrão aquosas e os métodos otimizados foram aplicados nas amostras em estudo. Em todas as amostras os elementos As, Cd, Pb e Tl apresentaram valores de concentração abaixo do limite de detecção. Das seis amostras analisadas, três apresentaram valores de concentração de Cu abaixo dos parâmetros mínimos estabelecidos pela legislação brasileira, enquanto que para o Mn todas amostras apresentaram valores de concentração dentro dos parâmetros mínimos da legislação brasileira. Os métodos desenvolvidos foram simples, exatos e precisos, podendo ser utilizados para análise de rotina. / The consumption of infant formula in Brazil, as a replacement of breast milk, has lately increased significantly. It is a major concern for health agencies because the exclusive breastfeeding up to at least 6 months is no longer part of most infants. The products used as a substitute of the breast milk contain sufficient amounts of vitamins and nutrients, which helps in the normal development of the infants. However, besides the essential elements, it may contain potentially toxic elements present in raw material or from of the processing and storage stages of the same. In the present work the presence of the essential (Cu e Mn) and potentially toxic elements (As, Cd, Pb e Tl) in infant formulas were evaluated. For this, analytical methods were developed for the determination of As, Cd, Cu, Mn, Pb and Tl using high-resolution continnum source graphite furnace atomic absorption spectrometry and direct solid sampling analysis in infant formulas. The samples were acquired in Porto Alegre’s market, RS, Brazil, all in powder form with different compositions and raw materials (rice, oats, soy and bovine milk). The calibration curves were performed with aqueous standard solutions and the optimized methods were applied in the study samples. In all samples, the concentration values of As, Pb, Cd and Tl were below of the limit of detection. For the analyzed samples, three of them present the concentration values of Cu lower than the minimum parameters established by Brazilian legislation, while for Mn, all samples present the concentration values within the minimum parameters of Brazilian legislation. The developed methods for the determination of these elements in infant formulas were simple, exacts and precise, and can be applicated for the routine analysis.

Page generated in 0.0826 seconds