Estudo de parâmetros dosimétricos e dosimetria in vivo em radioterapia / Study of dosimetric parameters and in vivo dosimetry in RadiotherapyMirko Salomón Alva Sánchez 31 August 2007 (has links)
Os resultados esperados em Radioterapia requerem o controle da qualidade dos procedimentos executados, existindo a necessidade de avaliar-se a dose administrada aos pacientes e sendo recomendado que a diferença percentual entre as doses prescrita e administrada esteja entre -5% e +7%, conforme a Comissão Internacional sobre Unidades e Medidas em Radiação (ICRU). Especificamente em tratamentos de irradiação de corpo inteiro (TBI, do inglês Total Body Irradiation), que emprega distâncias fonte-superfície extensas e campos largos de radiação, apresentando um grau de complexidade elevada quando comparada com os procedimentos convencionais, não há um protocolo bem estabelecido para o cálculo da dose absorvida. Considerando-se, por outro lado, os efeitos colaterais severos associados ao tratamento, TBI requer um controle rigoroso das doses administradas ao paciente, fazendo com que um programa de verificação do tratamento através de dosimetria in vivo seja imprescindível. O presente trabalho apresenta um estudo dos parâmetros dosimétricos, para campos convencionais e de irradiação de corpo inteiro, como parte de um programa de controle da qualidade em Radioterapia. Os parâmetros dosimétricos foram determinados utilizando-se dosímetros termoluminescentes, câmara de ionização e dosímetro semicondutor. Avaliaram-se as correções necessárias para o uso dos parâmetros dosimétricos, obtidos em condições convencionais, nos tratamentos de irradiação de corpo inteiro, apresentado-se, ainda, uma metodologia de dosimetria in vivo para tratamentos de TBI. Os resultados obtidos permitem concluir que os parâmetros dosimétricos utilizados em TBI devem ser obtidos nas condições próprias desse tipo de técnica, não devendo ser adaptados de condições convencionais, e que a metodologia de dosimetria de entrada é adequada para avaliação das doses nessa técnica de tratamento. / The expected outcomes in Radiotherapy require a strict quality control program to be performed in order to evaluate the doses delivered to patients. Accordingly to the International Commission on Radiation Units and Measurements (ICRU) the possible discrepancies between prescribed and delivered doses to patients must be in a range of -5% and +7%. Treatments of total body irradiation (TBI) use large source-surface distances and broad radiation fields, showing high complexity when compared to conventional procedures and do not present a well-established protocol for the calculation of the absorbed dose. On the other hand, considering, the severe collateral effects associated to this treatment, TBI requires a rigorous control of the doses administrated to the patient and a program of verification of the treatment through in vivo dosimetry is paramount. This work presents a study of dosimetric parameters for both conventional and total body irradiation treatments as part of a quality control program in Radiotherapy. The dosimetric parameters had been determined using termoluminescente dosimetry, ionization chamber, and semiconductor dosimeters. Possible corrections for the use of the conventional conditions-obtained parameters in total body irradiation were evaluated. An in vivo dosimetry methodology had been also studied to be applied to TBI treatments. The obtained results leads to the conclusions that TBI dosimetric parameters must be obtained under proper irradiation conditions and should not be adapted from conventional conditions and that entrance dosimetry is an adequate technique to evaluate delivered doses in TBI.
|
12 |
Implementação de um sistema dosimétrico termoluminescente para utilização em dosimetria in vivo em teleterapia com feixes de fótons de energia alta / Implementation of a thermoluminescent dosimetric system for use in in vivo dosimetry on radiotherapy with external high energy photon beamsLindomar Soares dos Santos 15 October 2007 (has links)
A dosimetria in vivo é a verificação final da dose real administrada ao paciente e tornou-se atualmente necessária devido ao aumento da complexidade e da sofisticaçã das técnicas radioterápicas. A finalidade deste trabalho foi apresentar, verificar e avaliar alguns procedimentos básicos, práticos e viáveis para a implementação da dosimetria in vivo com dosímetros termoluminescentes na verificação de dose em um serviço de radioterapia. Para o estabelecimento do sistema dosimétrico termoluminescente, alguns testes e medições foram realizados, incluindo o procedimento de inicialização, a determinação da homogeneidade do grupo de dosímetros, a determinação do fator de correção individual de cada dosímetro, a determinação da faixa de linearidade do sistema e do coeficiente de calibração. Medições em um objeto simulador antropomórfico foram realizadas para garantir que os métodos utilizados são satisfatórios antes que estes fossem usados para medições em pacientes. Medições de dose em um paciente foram feitas em um tratamento de câncer de próstata. A metodologia proposta pode ser usada como parte de um programa de garantia de qualidade em um serviço de radioterapia. / In vivo dosimetry is the ultimate check of the actual dose delivered to an individual patient and has become a procedure actually necessary due to increasing complexity and sophistication of radiotherapy techniques. The purpose of the present work was to present, verify and evaluate some basic, practical and viable procedures for the implementation of in vivo dosimetry with thermoluminescent dosimeters for patient dose verification at a radiotherapy service. For the setting up of the thermoluminescent dosimetric system, several tests and measurements were carried out including the initialisation procedure, the determination of the batch homogeneity, the determination of individual correction factor of each dosimeter, the determination of linearity range of the system and its calibration coefficients. Anthropomorphic phantom measurements were taken to ensure that the methods are satisfactory before they are used for patients measurements. Patient dose measurements were carried out in a prostate cancer treatment. The proposed methodology can be used as a part of a quality assurance program in a radiotherapy service.
|
13 |
Caracterização de dosímetros semicondutores e suas aplicações em técnicas especializadas em radioterapia / Characterization of Semiconductors Dosimeters and their Applications in Specialized Techniques in Radiation Therapy.Fernanda Ferretti de Oliveira 21 December 2012 (has links)
Introdução: A Radioterapia é frequentemente utilizada no tratamento do câncer, seja como uma modalidade simples ou em combinação com outras modalidades, tais como a cirurgia e a quimioterapia. Com o objetivo de eliminar células não desejadas no organismo humano, utiliza-se de radiações ionizantes para provocar a destruição de células tumorais pela absorção da energia da radiação incidente. A principal dificuldade encontrada em radioterapia é que as células tumorais não são tratadas isoladamente, isto é, o dano da radiação não é restrito somente às células tumorais, mas afeta também as células normais. Assim sendo, é essencial que a dose de radiação liberada nos tecidos normais seja tão baixa quanto possível para minimizar o risco de efeitos colaterais provocados pelos tratamentos radioterápicos. Objetivos: O objetivo deste trabalho é a caracterização de dosímetros semicondutores e dosímetros termoluminescentes e suas aplicações em técnicas não convencionais de Radioterapia. A partir da caracterização será possível a implementação dos dosímetros como sistema de dosimetria in vivo em teleterapia com feixe de fótons, visando atender as necessidades prementes do Serviço de Radioterapia do HCFMRP em implantar a técnica de irradiação de corpo inteiro e em realizar o controle de dose administrada ao paciente. Metodologia e Resultados: Diodos semicondutores foram caracterizados de acordo com o fator campo, angulação, taxa de dose, temperatura e fator bandeja, para obtenção dos fatores de correção. Verificou-se que a variação da resposta dos diodos com a temperatura, angulação e taxa de dose não foi significativa. Fatores campo foram calculados e registrados para campos de 3x3 cm 2 a 40x40cm 2 , onde se observou aumento na leitura do diodo com o aumento no campo. A resposta com a taxa de dose apr esentou pouca variação (de 100cGy/min para 300cGy/min a variação foi menor que 1,2%). O fator bandeja encontrado foi de 0,95±0,01 demonstrando que a presença da bandeja provoca diminuição na resposta do detector. Após a caracterização, os diodos foram calibrados em setup TBI para determinação dos fatores de calibração para cada espessura simulada do paciente (DLL). A dosimetria in vivo foi realizada em 3 pacientes submetidos ao tratamento de TBI do HCFMRP. A diferença percentual máxima entre as medidas com diodo e o valor nominal de dose foi de 3,6%, o que está de acordo com o recomendado pelo ICRU (+/- 5%). Os resultados demonstram a viabilidade e confiabilidade da técnica de dosimetria com diodos semicondutores para Controle de Qualidade de dose em tratamento de TBI. Ainda, dosímetros termoluminescentes foram caracterizados quanto à homogeneidade do grupo e a linearidade. Os fatores de calibração individuais foram encontrados e os dosímetros foram aplicados em simulações em setup TBI. Os cálculos de dose das simulações realizadas com os termoluminescentes inseridos nos orifícios de um OSA demonstraram concordância com os valores nominais de dose. Para as regiões do tórax superior e inferior, onde os TLD receberam doses mais elevadas (>150cGy), recomendou-se a utilização de compensadores de dose, para a prática clínica.Uma câmara de ionização foi utilizada como dosímetro de referência em todas as etapas de calibração e caracterização dos diodos e termoluminescentes. Conclusões: Este estudo mostrou que, para tratamentos de irradiação de corpo inteiro, quando o paciente estiver sendo preparado para um transplante de medula óssea, e o planejamento necessitar de uma grande eficácia na distribuição de dose, a metodologia com aplicações de dosímetros semicondutores apresenta-se como uma alternativa viável, precisa e de grande importância para o controle dosimétrico. Assim, ficou evidenciada a importância da utilização do diodo para o Controle de Qualidade, na avaliação da dos e a ser ministrada ao paciente, pelo menos em toda primeira fração de tratamento de TBI. Além disso, ficou demonstrada a aplicabilidade dos dosímetros termoluminescentes para controle dosimétrico, demonstrando o valor da dosimetria termoluminescente como um sistema de verificação de dose e sua eficácia como parte de um programa de garantia de qualidade em Radioterapia. A caracterização dos termoluminescentes evidenciou a possibilidade de aplicação da técnica TL em dosimetria in vivo. / Introduction: Radiation therapy is often used in cancer treatment, either as a single modality or in combination with other modalities, such as surgery and chemotherapy. Aiming to eliminate unwanted cells in the human body, radiation therapy uses ionizing radiation to cause destruction of tumor cells by absorbing the energy of the incident radiation. The main difficulty in radiation therapy is that tumor cells are not separately treated. The radiation damage is not restricted solely to tumor cells, but also affects normal cells. Therefore, it is essential that the radiation dose released in normal tissues is as low as possible to minimize the risk of side effects caused by radiotherapy treatments. Objectives: The objective of this work is the characterization of semiconductor dosimeters and thermoluminescent dosimeters and their applications in non -conventional radiotherapy techniques. After characterization it will be possible to implement the dosimeters as a system of in vivo dosimetry in radiotherapy with photon beam, to meet the pressing needs of the Radiotherapy Service of HCFMRP in deploying the technique of total body irradiation and make the control of dose administered to the patient . Methodology and Results: Semiconductor diodes were characterized according to the field factor, angle, dose rate, temperature and tray factor to obtain the correction factors. It was found that the variation of the response of the diodes with temperature, angle and dose rate was not significant. Field factors were calculated and recorded for fields from 3x3 cm 2 to 40x40cm 2 , wher e there was an increase in the reading of the diode with increasing field. The response with dose rate showed small variation (from 100cGy/min to 300cGy/min the variation was less than 1.2%). The tray factor was 0.95 ± 0.01 demonstrating that the tray decreases detector response. After characterization, the diodes were calibrated in TBI setup for determining the calibration factors for each simulated patient thickness (latero-lateral distance). The in vivo dosimetry was performed in 3 patients undergoing TBI treatment in HCFMRP. The maximum percentage difference between the measurements and the diode nominal dose was 3.6%, which is consistent with that recommended by ICRU (+ / - 5%). The results demonstrate the feasibility and reliability of the dosimetry technique with semiconductor diodes for dose quality control in TBI treatments. Still, dosimeters were characterized by group homogeneity and linearity. The calibration factors were found and individual dosimeters were applied in simulations with TBI setup. The dose calculation of simulations performed with the thermoluminescent inserted in holes of the phantom showed agreement with the nominal dose. For regions of the upper and lower thorax where TLD received higher doses (> 150cGy) it was recommended the use of compensating dose in clinic. An ionization chamber dosimeter was used as reference in all stages of calibration and characterization of diodes and thermoluminescents. Conclusions: This study showed that, for total body irradiation treatments, when the patient is being prepared for a bone marrow transplant, and planning requires a great effect on the dose distribution, the methodology with semiconductor dosimeters presented a viable alternative, and has great importance for the dosimetric control. The study proved the importance of diode semiconductors for quality control, for evaluation of the dose to be administered to the patient, at least throughout the first fraction of TBI treating. Furthermore, it was demonstrated the applicability of TLD for control quality, demonstrating the value of thermoluminescent dosimetry as a dose verification system and its effectiveness as part of a program of quality assurance in radiotherapy. The characterization of thermoluminescent showed the possibility of applying the TL technique in in vivo dosimetry.
|
14 |
Programa de controle da qualidade dosimétrico, validado com auxílio de filme radiocrômico, aplicado à radioterapia estereotáxica / Dosimetric quality assurance with the help of the radiochromic film, applied to stereotactic radiotherapy.Amaral, Leonardo Lira do 08 March 2012 (has links)
A Radioterapia de lesões cerebrais próximas a estruturas críticas necessitam de uma alta precisão na localização e na dose. O rigor na liberação da dose deve ser acompanhado por um preciso controle da qualidade nos aparelhos que envolvam a prática. O comissionamento do sistema de planejamento consiste em averiguar e confirmar os cálculos realizados pelo sistema. Porém, mesmo com todo controle da qualidade no comissionamento, existem vários aspectos que podem influenciar na administração da dose no volume alvo, o que exige a necessidade de se fazer uma avaliação final, no ato do tratamento, in vivo. O objetivo deste trabalho é desenvolver uma técnica de dosimetria in vivo como parte de um programa de controle da qualidade em radioterapia estereotáxica. Na técnica de dosimetria in vivo, utilizaram-se segmentos de filme radiocrômico, com dimensões de 1x1 cm2, acoplados na área externa ao colimador formado por micro-lâminas, Moduleaf. Estes filmes foram inseridos na região central do feixe. Os filmes foram irradiados e calibrados para obtenção dos fatores campos, na configuração da técnica. Com estes dados foi elaborado um programa computacional, o qual calcula a densidade relativa que um filme deve adquirir quando submetido a uma exposição nesta configuração. Como a técnica de dosimetria in vivo usa os dados do TPS, validaram-se alguns parâmetros do comissionamento do TPS. Complementando o estudo da dosimetria in vivo foram avaliados cinco planos não co-planares, sendo o primeiro com 15 campos e os outros com 25 campos. Antes de iniciar o procedimento o segmento de filme era acoplado ao aparelho e após a execução do tratamento a densidade ótica era avaliada e comparada com a calculada pelo programa desenvolvido. No comissionamento, todas as dosimetrias relativas apresentaram diferenças percentuais menores que 2%, quando comparados os resultados medidos com os calculados pelo sistema de planejamento. No desenvolvimento da técnica de dosimetria in vivo, a diferença percentual média da verificação dosimétrica, no momento da irradiação, comparado com a calculada pela planilha foi de 1,5%, enquanto que a dosimetria absoluta aplicada ao controle da qualidade convencional foi aprovada com diferença percentual média de 2,5% e a função gama média encontrada foi de 97,9% dos pontos aprovados com critério de aceitação %=2% e D=2 mm. Logo, todos os dados estão em concordância com os limites estabelecidos pelo TRS-430. Desta forma, conclui-se que foi desenvolvida uma técnica de dosimetria in vivo como parte de um programa de controle da qualidade em radioterapia estereotáxica com filme radiocrômico, já que foram confirmados os parâmetros básicos do comissionamento do sistema de planejamento e a técnica foi validada com o controle de qualidade convencional nos cinco planos analisados. / Radiation therapy of brain lesions near critical structures requires a highly accurate location and dose. The accuracy in dose delivery should be accompanied by an accurate quality control in devices involving the practice. The commissioning of the planning system is to ascertain and confirm the calculations performed by the system, but even with all quality control in the commissioning, there are several aspects that may influence the dosing the target volume, which necessitates the need to make a final assessment at the time of treatment, in vivo. The objective of this work is to develop a technique for in vivo dosimetry as part of quality assurance in stereotactic radiotherapy. In vivo dosimetry technique, we used segments of film radiocrômico, with dimensions of 1x1 cm2, coupled to the external area formed by the micro-collimator blades, Moduleaf. These films were inserted in the central region of the beam. The films were irradiated and calibrated to obtain factors of fields in the configuration of the technique. With these data we designed a computer program which calculates the relative density of a film must acquire when subjected to an exposure in this setting. As the technique of in vivo dosimetry using data from the TPS, validated parameters are the commissioning of the TPS. Complementing the study of in vivo dosimetry were evaluated five non-coplanar plans, the first with 15 fields and the other with 25 fields. Before starting the procedure, the film segment was attached to the unit and after the treatment is the optical density was measured and compared with those calculated by the program developed. At commissioning, all presented on dosimetry percentage differences less than 2%, when comparing the measured results with those calculated by the planning system. In developing the technique of in vivo dosimetry, the mean percent difference dosimetry verification at the time of irradiation compared with the calculated by the sheet was 1.5%, while the absolute dosimetry applied to the conventional quality control has been approved as mean percent difference 2.5% and the gamma function mean was 97.9% of the points agreed with the acceptance criterion % = 2% and D = 2 mm. Therefore, all data are in agreement with the limits set by TRS-430. Thus, we conclude that we have developed a technique for in vivo dosimetry as part of a quality assurance in stereotactic radiotherapy radiocrômico film, since some parameters were confirmed to commissioning the planning system and the technique was validated with control quality standard in five plans analyzed.
|
15 |
Desenvolvimento de uma metodologia de avaliação dosimétrica de transmissão, usando filmes radiocrômicos em tratamentos radioterápicos / Development of a methodology for transmission dosimetric evaluation using radiochromic film in radiotherapy treatmentsAmaral, Leonardo Lira do 14 March 2014 (has links)
Apesar da introdução do controle da qualidade individual nas técnicas complexas de tratamentos, tem-se comprovado que, mesmo assim, é possível a ocorrência de erros na aplicação da dose no momento da aplicação. No entanto, ainda não estão bem estabelecidas as ferramentas de redundância a fim de controlar a dose no momento da terapêutica, além do que, as técnicas mais modernas de tratamento radioterápico desenvolvem as aplicações com feixes rotacionais e os dosímetros tradicionalmente utilizados em controle da qualidade oferecem limitações angulares. Assim, este trabalho vem contribuir para o desenvolvimento de uma metodologia de controle da qualidade de transmissão in vivo utilizando filmes radiocrômicos acoplados ao cabeçote do acelerador linear, durante aplicações radioterápicas nas técnicas de tratamento conformacional e IMRT. A metodologia de controle da qualidade desenvolvida neste trabalho baseia-se na obtenção da distribuição de dose in vivo de tratamentos radioterápicos com um filme radiocrômico EBT2 posicionado em um suporte acrílico, semelhante a uma bandeja, a uma distância fonte-superfície de 56,8 cm, acoplado ao acessório holder do acelerador linear durante a aplicação de todo o tratamento teleterápico. Posteriormente, foi realizada uma análise gama para comparação da distribuição de dose medida pelo filme com a esperada pelo sistema de planejamento, obtida no plano coronal e central de um objeto simulador, com dimensões semelhantes ao suporte acrílico, posicionado à distância de 100 cm, como resultado da transferência do plano em questão. Com os resultados encontrados na seção conformacional, avaliando tanto a simulação Monte Carlo quanto as irradiações, pode-se concluir que a diferença entre a distribuição de dose do sistema de planejamento, na distância foco detector de 100 cm, e do filme, na distância de 56,8 cm, é diminuta e, desta forma, é viável criar uma metodologia para verificação dosimétrica de transmissão utilizando o filme radiocrômico acoplado ao cabeçote do acelerador. O controle da qualidade proposto na técnica de IMRT concordou com o esperado em 24 das 25 situações testadas, apresentando apenas um resultado diferente, ou seja, uma concordância de 96% com o esperado. As avaliações in vivo concordaram com 98% dos controles avaliados. Desta forma, pode-se concluir que a metodologia proposta neste trabalho é factível para o controle da qualidade de transmissão in vivo, em tratamentos radioterápicos que usam a técnica de tratamento conformacional e IMRT e, como ela não oferece dificuldades para o deslocamento angular do gantry, ela poderá ser aplicada em técnicas teleterápicas mais modernas. / Even with the introduction of the individual quality control in the complex techniques of radiation therapy treatments, the occurrence of errors in the release of the dose at the time of application is possible. However, in order to monitor the dose at the time of therapy, redundancy tools are not yet well established, Besides that, the most modern techniques of radiation treatment use rotational beams to deliver the desired dose distributions and the dosimeters traditionally used in quality control of radiation therapy suffer angular limitations. In this way, this work aims to contribute to the development of a methodology of transmission quality control in vivo presenting a dose control technique using radiochromic film coupled to the headstock linear accelerator for radiotherapy applications to monitor conformational techniques and IMRT treatment. The quality control methodology developed in this work is based on obtaining the in vivo dose distribution of radiotherapy treatments with a radiochromic film EBT2, positioned on an acrylic stand, similar to a tray at a source-surface distance of 56.8 cm, coupled to the linear accelerator accessory holder during application of any treatment. It was subsequently performed a gama analysis for comparison of the dose distribution measured by the film with the expected dose distribution by the treatment planning system. The expected dose distribution was obtained in the coronal and central plane of a phantom, with similar dimensions to the acrylic stand and positioned on a source-surface distance of 100 cm as a result of the transfer of the plan in question. Based on the results presented in the conformational section, evaluating both, Monte Carlo simulation and irradiation results, it can be concluded that the difference between the distribution of the dose planning system, focus distance 100 cm detector, and the film, on distance of 56.8 cm, are small, and in this way it is feasible to create a methodology for dosimetry verification using radiochromic film coupled to the head of the accelerator. The proposed quality control in IMRT technique agreed with expected in 24 simulations of the 25 situations tested, showing only one different result, i.e., there was a 96% concordance with the expected. In this way, it can be concluded that the methodology proposed in this work is feasible for the in vivo quality control of radiation therapy treatments that use the conformational and IMRT treatment techniques, and also can be applied to the most modern radiotherapy techniques since, it does not offer difficulties with the angular displacement of the gantry.
|
16 |
Desenvolvimento de uma metodologia de avaliação dosimétrica de transmissão, usando filmes radiocrômicos em tratamentos radioterápicos / Development of a methodology for transmission dosimetric evaluation using radiochromic film in radiotherapy treatmentsLeonardo Lira do Amaral 14 March 2014 (has links)
Apesar da introdução do controle da qualidade individual nas técnicas complexas de tratamentos, tem-se comprovado que, mesmo assim, é possível a ocorrência de erros na aplicação da dose no momento da aplicação. No entanto, ainda não estão bem estabelecidas as ferramentas de redundância a fim de controlar a dose no momento da terapêutica, além do que, as técnicas mais modernas de tratamento radioterápico desenvolvem as aplicações com feixes rotacionais e os dosímetros tradicionalmente utilizados em controle da qualidade oferecem limitações angulares. Assim, este trabalho vem contribuir para o desenvolvimento de uma metodologia de controle da qualidade de transmissão in vivo utilizando filmes radiocrômicos acoplados ao cabeçote do acelerador linear, durante aplicações radioterápicas nas técnicas de tratamento conformacional e IMRT. A metodologia de controle da qualidade desenvolvida neste trabalho baseia-se na obtenção da distribuição de dose in vivo de tratamentos radioterápicos com um filme radiocrômico EBT2 posicionado em um suporte acrílico, semelhante a uma bandeja, a uma distância fonte-superfície de 56,8 cm, acoplado ao acessório holder do acelerador linear durante a aplicação de todo o tratamento teleterápico. Posteriormente, foi realizada uma análise gama para comparação da distribuição de dose medida pelo filme com a esperada pelo sistema de planejamento, obtida no plano coronal e central de um objeto simulador, com dimensões semelhantes ao suporte acrílico, posicionado à distância de 100 cm, como resultado da transferência do plano em questão. Com os resultados encontrados na seção conformacional, avaliando tanto a simulação Monte Carlo quanto as irradiações, pode-se concluir que a diferença entre a distribuição de dose do sistema de planejamento, na distância foco detector de 100 cm, e do filme, na distância de 56,8 cm, é diminuta e, desta forma, é viável criar uma metodologia para verificação dosimétrica de transmissão utilizando o filme radiocrômico acoplado ao cabeçote do acelerador. O controle da qualidade proposto na técnica de IMRT concordou com o esperado em 24 das 25 situações testadas, apresentando apenas um resultado diferente, ou seja, uma concordância de 96% com o esperado. As avaliações in vivo concordaram com 98% dos controles avaliados. Desta forma, pode-se concluir que a metodologia proposta neste trabalho é factível para o controle da qualidade de transmissão in vivo, em tratamentos radioterápicos que usam a técnica de tratamento conformacional e IMRT e, como ela não oferece dificuldades para o deslocamento angular do gantry, ela poderá ser aplicada em técnicas teleterápicas mais modernas. / Even with the introduction of the individual quality control in the complex techniques of radiation therapy treatments, the occurrence of errors in the release of the dose at the time of application is possible. However, in order to monitor the dose at the time of therapy, redundancy tools are not yet well established, Besides that, the most modern techniques of radiation treatment use rotational beams to deliver the desired dose distributions and the dosimeters traditionally used in quality control of radiation therapy suffer angular limitations. In this way, this work aims to contribute to the development of a methodology of transmission quality control in vivo presenting a dose control technique using radiochromic film coupled to the headstock linear accelerator for radiotherapy applications to monitor conformational techniques and IMRT treatment. The quality control methodology developed in this work is based on obtaining the in vivo dose distribution of radiotherapy treatments with a radiochromic film EBT2, positioned on an acrylic stand, similar to a tray at a source-surface distance of 56.8 cm, coupled to the linear accelerator accessory holder during application of any treatment. It was subsequently performed a gama analysis for comparison of the dose distribution measured by the film with the expected dose distribution by the treatment planning system. The expected dose distribution was obtained in the coronal and central plane of a phantom, with similar dimensions to the acrylic stand and positioned on a source-surface distance of 100 cm as a result of the transfer of the plan in question. Based on the results presented in the conformational section, evaluating both, Monte Carlo simulation and irradiation results, it can be concluded that the difference between the distribution of the dose planning system, focus distance 100 cm detector, and the film, on distance of 56.8 cm, are small, and in this way it is feasible to create a methodology for dosimetry verification using radiochromic film coupled to the head of the accelerator. The proposed quality control in IMRT technique agreed with expected in 24 simulations of the 25 situations tested, showing only one different result, i.e., there was a 96% concordance with the expected. In this way, it can be concluded that the methodology proposed in this work is feasible for the in vivo quality control of radiation therapy treatments that use the conformational and IMRT treatment techniques, and also can be applied to the most modern radiotherapy techniques since, it does not offer difficulties with the angular displacement of the gantry.
|
17 |
Programa de controle da qualidade dosimétrico, validado com auxílio de filme radiocrômico, aplicado à radioterapia estereotáxica / Dosimetric quality assurance with the help of the radiochromic film, applied to stereotactic radiotherapy.Leonardo Lira do Amaral 08 March 2012 (has links)
A Radioterapia de lesões cerebrais próximas a estruturas críticas necessitam de uma alta precisão na localização e na dose. O rigor na liberação da dose deve ser acompanhado por um preciso controle da qualidade nos aparelhos que envolvam a prática. O comissionamento do sistema de planejamento consiste em averiguar e confirmar os cálculos realizados pelo sistema. Porém, mesmo com todo controle da qualidade no comissionamento, existem vários aspectos que podem influenciar na administração da dose no volume alvo, o que exige a necessidade de se fazer uma avaliação final, no ato do tratamento, in vivo. O objetivo deste trabalho é desenvolver uma técnica de dosimetria in vivo como parte de um programa de controle da qualidade em radioterapia estereotáxica. Na técnica de dosimetria in vivo, utilizaram-se segmentos de filme radiocrômico, com dimensões de 1x1 cm2, acoplados na área externa ao colimador formado por micro-lâminas, Moduleaf. Estes filmes foram inseridos na região central do feixe. Os filmes foram irradiados e calibrados para obtenção dos fatores campos, na configuração da técnica. Com estes dados foi elaborado um programa computacional, o qual calcula a densidade relativa que um filme deve adquirir quando submetido a uma exposição nesta configuração. Como a técnica de dosimetria in vivo usa os dados do TPS, validaram-se alguns parâmetros do comissionamento do TPS. Complementando o estudo da dosimetria in vivo foram avaliados cinco planos não co-planares, sendo o primeiro com 15 campos e os outros com 25 campos. Antes de iniciar o procedimento o segmento de filme era acoplado ao aparelho e após a execução do tratamento a densidade ótica era avaliada e comparada com a calculada pelo programa desenvolvido. No comissionamento, todas as dosimetrias relativas apresentaram diferenças percentuais menores que 2%, quando comparados os resultados medidos com os calculados pelo sistema de planejamento. No desenvolvimento da técnica de dosimetria in vivo, a diferença percentual média da verificação dosimétrica, no momento da irradiação, comparado com a calculada pela planilha foi de 1,5%, enquanto que a dosimetria absoluta aplicada ao controle da qualidade convencional foi aprovada com diferença percentual média de 2,5% e a função gama média encontrada foi de 97,9% dos pontos aprovados com critério de aceitação %=2% e D=2 mm. Logo, todos os dados estão em concordância com os limites estabelecidos pelo TRS-430. Desta forma, conclui-se que foi desenvolvida uma técnica de dosimetria in vivo como parte de um programa de controle da qualidade em radioterapia estereotáxica com filme radiocrômico, já que foram confirmados os parâmetros básicos do comissionamento do sistema de planejamento e a técnica foi validada com o controle de qualidade convencional nos cinco planos analisados. / Radiation therapy of brain lesions near critical structures requires a highly accurate location and dose. The accuracy in dose delivery should be accompanied by an accurate quality control in devices involving the practice. The commissioning of the planning system is to ascertain and confirm the calculations performed by the system, but even with all quality control in the commissioning, there are several aspects that may influence the dosing the target volume, which necessitates the need to make a final assessment at the time of treatment, in vivo. The objective of this work is to develop a technique for in vivo dosimetry as part of quality assurance in stereotactic radiotherapy. In vivo dosimetry technique, we used segments of film radiocrômico, with dimensions of 1x1 cm2, coupled to the external area formed by the micro-collimator blades, Moduleaf. These films were inserted in the central region of the beam. The films were irradiated and calibrated to obtain factors of fields in the configuration of the technique. With these data we designed a computer program which calculates the relative density of a film must acquire when subjected to an exposure in this setting. As the technique of in vivo dosimetry using data from the TPS, validated parameters are the commissioning of the TPS. Complementing the study of in vivo dosimetry were evaluated five non-coplanar plans, the first with 15 fields and the other with 25 fields. Before starting the procedure, the film segment was attached to the unit and after the treatment is the optical density was measured and compared with those calculated by the program developed. At commissioning, all presented on dosimetry percentage differences less than 2%, when comparing the measured results with those calculated by the planning system. In developing the technique of in vivo dosimetry, the mean percent difference dosimetry verification at the time of irradiation compared with the calculated by the sheet was 1.5%, while the absolute dosimetry applied to the conventional quality control has been approved as mean percent difference 2.5% and the gamma function mean was 97.9% of the points agreed with the acceptance criterion % = 2% and D = 2 mm. Therefore, all data are in agreement with the limits set by TRS-430. Thus, we conclude that we have developed a technique for in vivo dosimetry as part of a quality assurance in stereotactic radiotherapy radiocrômico film, since some parameters were confirmed to commissioning the planning system and the technique was validated with control quality standard in five plans analyzed.
|