• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Effects of municipal wastewater on soil chemical properties in cultivating turfgrass using subsurface drip irrigation

Tabatabaei, Sayyed-Hassan, Mousavi, Seyyed Mohammad, Mirlatifi, Seyed Majid, Sharifnia, Rezvan Sadat, Pessarakli, Mohammad 04 January 2017 (has links)
Knowing the concentrations of the nutrient elements in soils is important due to their toxic effect on humans and the environment. The aims of this study were to assess the effects of water quality, depths and distances of lateral installation on soil chemical properties during turfgrass cultivation. A field experiment was conducted using a Split Split Plot design based on the Randomized complete Block (RCB) with two treatments (well’s and wastewater), and eight sub-treatments (45 and 60 cm distance of the laterals and 15, 20, 25, and 30 cm depths of laterals) in three replicates on a sandy-loam soil, in Shahrekord, Iran. Soil samples were collected from 0-30 and 30-60 cm depth for measuring nitrate (NO3-), electrical conductivity (EC), and pH at the end of the experiment. During the experiment, fecal coliform (FC) were also measured at the soil surface. Results indicated that by increasing lateral distance, NO3- level increased in both layers. With installing laterals in deeper levels, NO3- concentration decreased at the beginning, then increased in the first layer, whereas in the second layer NO3- concentration decreased. In addition, installing laterals in deeper depth, caused an increase in soil EC in the top layer, but a decrease in the lower layer. However, the results showed that there was no significant effect of experimental factors on soil pH. The results also show that with increasing laterals depth, Fc level decreased at the soil surface.
2

Estudo da uniformidade de emissão de água utilizando diferentes espaçamentos entre gotejadores na linha lateral /

Andrade, Luiz Antonio de, 1956- January 2009 (has links)
Orientador: João Carlos Cury Saad / Banca: Raimundo Leite Cruz / Banca: Rubens Duarte Coelho / Banca: Tarlei Arriel Botrel / Banca: Everaldo Chartuni Mantovani / Resumo: A irrigação por gotejamento no Brasil está crescendo no cultivo de hortaliças e frutas de ciclo anual. O adequado dimensionamento do projeto de irrigação por gotejamento visando altos Coeficientes de Uniformidade de Emissão de água é coerente com a pressão da sociedade pelo uso racional dos recursos naturais, especialmente a água. A utilização de linhas laterais mais longas promove redução de custos na instalação do projeto, entretanto pode reduzir a uniformidade de emissão de água, sendo que a otimização deste fator é importante objetivo de todo projeto criteriosamente executado. Propôs-se um modelo de mangueira gotejadora com dois segmentos, sendo o ultimo com um espaçamento padrão, e o segmento inicial com um espaçamento especial entre os emissores, com o objetivo de obter linhas mais longas sem prejudicar o Coeficiente de Uniformidade de Emissão de água. Mangueira gotejadora dimensionada teoricamente conforme o modelo proposto, com lateral de 150,6 m sendo 59,7 m iniciais com espaçamento entre emissores de 0,35 m associada com 90,9 m finais com distancia entre gotejadores de 0,30 m apresentou variação de vazão de 8,05 % e CUECVf de 97,62% e foi 36% mais longa que a mangueira gotejadora com único espaçamento de 0,30 m, com variação de vazão de 10 %, e CUECVf de 94,71.Ganhos semelhantes foram obtidos com os espaçamentos padrões de 0,40 e 0,50 m. Concluiu-se que modelo proposto tem possibilidade de ser aplicado na pratica da irrigação por gotejamento em cultivo adensado, por apresentar melhor CUE, lateral mais longa e menor variação de vazão. / Abstract: The use of drip irrigation in horticultural and annual cycle fruits in Brazil is growing. The correct sizing of a drip irrigation project, using High Emission Uniformity Coefficients, is in accordance with society's pressure for a rational use of natural resources. Sizing longer lateral irrigation lines promotes a cost reduction in the installation costs of a project. A model for a drip irrigation lateral composed of two segments is proposed; the last having a standard spacing, the initial segment having a special spacing between emitters, higher than the standard, with the objective of obtaining longer laterals, without decreasing the Emission Uniformity Coefficient of water, EUC.A theoretically dimensioned drip hose, in accordance with the proposed model, with a total length of 150.6 m, having the initial 59.7 m an emitter spacing of 0.3508 m, while the final 90.9 m an emitter spacing of 0.30 m, presented a flow variation of 8.05% and an EUC of 97.62%. It is 36% longer than a drip irrigation hose with a 0.30 m emitter spacing, with a 10% flow variation and a EUC of 94.71%. A substitution of the standard lateral model for the proposed lateral model still needs a field trial validation in order to justify its use, considering that the commercial production of this model is viable. / Doutor
3

Avaliação hidráulica e de resistência a tração de dois modelos de mangueiras gotejadoras

Andrade , Luiz Antonio de [UNESP] 25 January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-01-25Bitstream added on 2014-06-13T20:34:45Z : No. of bitstreams: 1 andrade_la_me_botfca.pdf: 1207218 bytes, checksum: c40efa691ed75ddb73200db6e9eaa325 (MD5) / Universidade Estadual Paulista (UNESP) / A irrigação por gotejamento no Brasil ganhou novo impulso a partir dos anos 90, quando diversas empresas internacionais especializadas neste mercado aportaram por aqui. Alguns destes produtos que estão no mercado, quando apresentam informações técnicas, normalmente não estão em Português. A existência de normas de avaliação que sejam aceitas pela comunidade tem grande valia para os que escolhem, projetam, compram, instalam, operam e avaliam equipamentos de irrigação. Uma norma estabelecida representa o estado da arte em sua área de atuação. A ISO 9261:2004 é uma norma internacional que orienta como avaliar e especificar gotejadores (emissores com vazão menor ou igual a 24 L.h-1) e entre outras informações, defini o que é uma mangueira gotejadora colapsável, ou fita do Inglês tape. O ensaio de resistência à tensão conforme a ISO 9261:2004 é uma ferramenta útil para classificar um modelo de mangueira gotejadora em reutilizável e não reutilizável. A mangueira reutilizável pode ser removida do campo e ser reinstalada de uma época de cultivo para outra. A mangueira gotejadora não reutilizável não é adequada para ser removida do campo para outra reinstalação. O objetivo deste estudo foi a de aplicar a ISO 9261:2004 na avaliação de mangueiras gotejadoras colapsáveis, daqui em diante citada como mangueira (s) gotejadora (s). No Laboratório de Irrigação da Universidade Estadual Paulista Julio de Mesquita Filho - Faculdade de Ciências Agronômicas, ensaiou-se duas mangueiras gotejadoras de acordo com a norma ISO 9261:2004. Uma marca é o Golden Drip fabricado na Coréia do Sul pela empresa Seo Won Inc, e a outra é um protótipo em fase de testes, codificado como P2015, da empresa Petroisa Brasil. Os dois produtos avaliados não foram especificados e/ou fabricados de acordo com a norma ISO 9261. As duas mangueiras gotejadoras são similares visualmente... / Drip irrigation systems in Brazilian Market have had an increase after 90`s, when several expertise international corporations in that business came here. Some drip tapes that farmers can find in Brazilian Market, donþt have technical information in Portuguese language. Standards in their respective areas can be important tools for people who select, design, purchase, install, operate and evaluate irrigation equipment. 5 The ISO 9261:2004 gives mechanical and functional requirements for agricultural irrigation emitters and emitting pipes, and, provides methods for testing conformity with such requirements. It also specifies the data to be supplied by the manufacturer to permit correct information, installation and operation in the field. It is applicable to emitters, emitting and dripping (trickling) pipes, hoses, including collapsible hoses (tapes) and tubing of which the emitting units form an integral part, to emitters and emitting units with or without pressure regulation and with flow rates not exceeding 24 L.h-1 per outlet. It is not applicable to porous pipe, nor does it cover the performance of pipes as regards clogging. The carry out the resistence to tension for emitting pipe is a good tool to classify in non-reusable and reusable emitting pipes. Non-reusable emitting pipe is not intended for removal from the field and reinstallation. Reusable emitting pipe is designed for removal from the field and reinstallation with proper handling from one season to another or under other circumstances. This work was developed at the Irrigation Laboratory - UNESP to evaluate two drip collapsible hose (P2015 and Golden Drip) according to ISO 9261:2004. The Golden Drip is a commercial product from South Korea and P2015 is an industrial prototype from Petroisa Brasil. Both drip tape are similar. The raw material is basic polyethylene resin added with UV protection...(Complete abstract click electronic access below)
4

Avaliação hidráulica e de resistência a tração de dois modelos de mangueiras gotejadoras /

Andrade , Luiz Antonio de, 1956- January 2005 (has links)
Orientador: João Carlos Cury Saad / Banca: Ramiundo Leite Cruz / Banca: Tarlei Arriel Botrel / Resumo: A irrigação por gotejamento no Brasil ganhou novo impulso a partir dos anos 90, quando diversas empresas internacionais especializadas neste mercado aportaram por aqui. Alguns destes produtos que estão no mercado, quando apresentam informações técnicas, normalmente não estão em Português. A existência de normas de avaliação que sejam aceitas pela comunidade tem grande valia para os que escolhem, projetam, compram, instalam, operam e avaliam equipamentos de irrigação. Uma norma estabelecida representa o estado da arte em sua área de atuação. A ISO 9261:2004 é uma norma internacional que orienta como avaliar e especificar gotejadores (emissores com vazão menor ou igual a 24 L.h-1) e entre outras informações, defini o que é uma mangueira gotejadora colapsável, ou fita do Inglês "tape". O ensaio de resistência à tensão conforme a ISO 9261:2004 é uma ferramenta útil para classificar um modelo de mangueira gotejadora em reutilizável e não reutilizável. A mangueira reutilizável pode ser removida do campo e ser reinstalada de uma época de cultivo para outra. A mangueira gotejadora não reutilizável não é adequada para ser removida do campo para outra reinstalação. O objetivo deste estudo foi a de aplicar a ISO 9261:2004 na avaliação de mangueiras gotejadoras colapsáveis, daqui em diante citada como mangueira (s) gotejadora (s). No Laboratório de Irrigação da Universidade Estadual Paulista "Julio de Mesquita Filho" - Faculdade de Ciências Agronômicas, ensaiou-se duas mangueiras gotejadoras de acordo com a norma ISO 9261:2004. Uma marca é o Golden Drip fabricado na Coréia do Sul pela empresa Seo Won Inc, e a outra é um protótipo em fase de testes, codificado como P2015, da empresa Petroisa Brasil. Os dois produtos avaliados não foram especificados e/ou fabricados de acordo com a norma ISO 9261. As duas mangueiras gotejadoras são similares visualmente...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Drip irrigation systems in Brazilian Market have had an increase after 90's, when several expertise international corporations in that business came here. Some drip tapes that farmers can find in Brazilian Market, donþt have technical information in Portuguese language. Standards in their respective areas can be important tools for people who select, design, purchase, install, operate and evaluate irrigation equipment. 5 The ISO 9261:2004 gives mechanical and functional requirements for agricultural irrigation emitters and emitting pipes, and, provides methods for testing conformity with such requirements. It also specifies the data to be supplied by the manufacturer to permit correct information, installation and operation in the field. It is applicable to emitters, emitting and dripping (trickling) pipes, hoses, including collapsible hoses ("tapes") and tubing of which the emitting units form an integral part, to emitters and emitting units with or without pressure regulation and with flow rates not exceeding 24 L.h-1 per outlet. It is not applicable to porous pipe, nor does it cover the performance of pipes as regards clogging. The carry out the resistence to tension for emitting pipe is a good tool to classify in non-reusable and reusable emitting pipes. Non-reusable emitting pipe is not intended for removal from the field and reinstallation. Reusable emitting pipe is designed for removal from the field and reinstallation with proper handling from one season to another or under other circumstances. This work was developed at the Irrigation Laboratory - UNESP to evaluate two drip collapsible hose (P2015 and Golden Drip) according to ISO 9261:2004. The Golden Drip is a commercial product from South Korea and P2015 is an industrial prototype from Petroisa Brasil. Both drip tape are similar. The raw material is basic polyethylene resin added with UV protection...(Complete abstract click electronic access below) / Mestre
5

Estudo da uniformidade de emissão de água utilizando diferentes espaçamentos entre gotejadores na linha lateral

Andrade, Luiz Antonio de [UNESP] 08 June 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-06-08Bitstream added on 2014-06-13T20:43:44Z : No. of bitstreams: 1 andrade_la_dr_botfca.pdf: 831598 bytes, checksum: b06b99430e825b80d7ec37981bcbe1c5 (MD5) / Universidade Estadual Paulista (UNESP) / A irrigação por gotejamento no Brasil está crescendo no cultivo de hortaliças e frutas de ciclo anual. O adequado dimensionamento do projeto de irrigação por gotejamento visando altos Coeficientes de Uniformidade de Emissão de água é coerente com a pressão da sociedade pelo uso racional dos recursos naturais, especialmente a água. A utilização de linhas laterais mais longas promove redução de custos na instalação do projeto, entretanto pode reduzir a uniformidade de emissão de água, sendo que a otimização deste fator é importante objetivo de todo projeto criteriosamente executado. Propôs-se um modelo de mangueira gotejadora com dois segmentos, sendo o ultimo com um espaçamento padrão, e o segmento inicial com um espaçamento especial entre os emissores, com o objetivo de obter linhas mais longas sem prejudicar o Coeficiente de Uniformidade de Emissão de água. Mangueira gotejadora dimensionada teoricamente conforme o modelo proposto, com lateral de 150,6 m sendo 59,7 m iniciais com espaçamento entre emissores de 0,35 m associada com 90,9 m finais com distancia entre gotejadores de 0,30 m apresentou variação de vazão de 8,05 % e CUECVf de 97,62% e foi 36% mais longa que a mangueira gotejadora com único espaçamento de 0,30 m, com variação de vazão de 10 %, e CUECVf de 94,71.Ganhos semelhantes foram obtidos com os espaçamentos padrões de 0,40 e 0,50 m. Concluiu-se que modelo proposto tem possibilidade de ser aplicado na pratica da irrigação por gotejamento em cultivo adensado, por apresentar melhor CUE, lateral mais longa e menor variação de vazão. / The use of drip irrigation in horticultural and annual cycle fruits in Brazil is growing. The correct sizing of a drip irrigation project, using High Emission Uniformity Coefficients, is in accordance with society's pressure for a rational use of natural resources. Sizing longer lateral irrigation lines promotes a cost reduction in the installation costs of a project. A model for a drip irrigation lateral composed of two segments is proposed; the last having a standard spacing, the initial segment having a special spacing between emitters, higher than the standard, with the objective of obtaining longer laterals, without decreasing the Emission Uniformity Coefficient of water, EUC.A theoretically dimensioned drip hose, in accordance with the proposed model, with a total length of 150.6 m, having the initial 59.7 m an emitter spacing of 0.3508 m, while the final 90.9 m an emitter spacing of 0.30 m, presented a flow variation of 8.05% and an EUC of 97.62%. It is 36% longer than a drip irrigation hose with a 0.30 m emitter spacing, with a 10% flow variation and a EUC of 94.71%. A substitution of the standard lateral model for the proposed lateral model still needs a field trial validation in order to justify its use, considering that the commercial production of this model is viable.

Page generated in 0.0255 seconds