• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 1
  • Tagged with
  • 33
  • 22
  • 20
  • 17
  • 17
  • 17
  • 16
  • 12
  • 11
  • 11
  • 11
  • 10
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Suportabilidade a Afundamentos de Tensão em Geradores DFIG Empregando Limitador Supercondutor

OLIVEIRA, F. D. C. 13 September 2016 (has links)
Made available in DSpace on 2018-08-02T00:02:00Z (GMT). No. of bitstreams: 1 tese_4743_Tese Flávio Duarte Couto Oliveira20161129-121045.pdf: 22560177 bytes, checksum: 86691b577fe6f3610a134faeb939e918 (MD5) Previous issue date: 2016-09-13 / No mundo moderno, a produção de energia elétrica é fundamental para o desenvolvimento industrial e econômico de um país. O crescimento econômico aliado à cescente conscientização ambiental tem aumentado a preocupação com as fontes de energia. Diante disso, há um grande estimulo a utilização de fontes alternativas. Dentre essas fontes alternativas, uma das mais promissoras é a energia eólica, que se tornou uma fonte de produção viável e competitiva. Entre as tecnologias de geradores eólicos, uma das mais utilizadas é a de Gerador de Indução Duplamente Alimentado - DFIG, adequado à operação com turbinas de velocidade variável. Essa tecnologia, DFIG, passou a ser amplamente utilizada por alguns países em seus sistemas elétricos. Como consequência, esses países foram obrigados a definir critérios de sua interconexão com a rede cada vez mais rígidos. Um dos principais critérios exige que a usina permaneça conectada à rede durante um afundamento momentâneo de tensão - AMT. Além disso, alguns códigos, como da Alemanha e Espanha, exigem que o sistema forneça potência reativa à rede durante o AMT para reduzir seu efeito. Neste trabalho é realizado um estudo teórico da influência dos AMTs em um sistema de conversão de energia eólica utilizando a tecnologia DFIG. Após isso, é apresentado uma nova solução para aumentar a suportabilidade da turbina durante um AMT equilibrado. Um dispositivo que incorpora limitadores de corrente supercondutores-LCS é proposto, sendo analisado em diferentes configurações e estratégias e é comparado com as soluções convencionais. A validação, feita por simulação computacional, utilizou o software PSCAD/EMTDC da Manitoba-HVDC. Os resultados de simulação mostram o bom desempenho do dispositivo aumentando a robustez do DFIG.
2

Vibrações monopolares isoescalares em alguns núcleos duplamente mágicos / Isoscalar monopolar vibrations in some doubly magic nuclei.

Galetti, Diógenes 11 August 1978 (has links)
Usamos o formalismo de A. Toledo Pisa e E. Passos, que usa o método de coordenadas geradores e o Teorema Espectral de Anélise Funcional, para obter uma hamiltoniana coletiva para as vibrações monopolares isoescalares nos núcleos duplamente mágicos ANPOT. 4 He, ANPOT. 16 O e ANPOT 40 C. As funções de onda do oscilador hermônico são tomadas como funções de onda geradoras, e a interação de muitos corpos é aquela de Skyrme. Com esta hamiltoniana coletiva calculamos o espectro de energias do modo monopolar isoescalar, parâmetros de inércia e módulos de incompressibilidade para aqueles núcleos e comparamos com os resultados de Flocard e Vautherin, que resolvem numericamente a equação de Griffin-Wheeler. Foram calculados ainda os raios quadráticos médios nucleares. Os efeitos espúrios dos movimentos do centro de massa são eliminados exatamente para o AMPOT. 4 He e recalculamos aquelas propriedades nucleares. / The isoscalar monopole vibrational mode in 4 He,16 O and 40Ca is studied with the aid of collective Hamiltonians obtained from e general formalism proposed by A. Toledo Piza and E. Passos, which makes use of the generator coordinate method and Functional Analisis Spectral Theorem. Cur generator wave functions are that of the harmonic oscillator and use is made of the Skyrme\'s schematic effective interaction. Using the collective Hamiltonian we can calculate the energy spectrum, inertial parameters end incompressibility modulus and compare with numerical results of Flocard and Vautherin. R. m. s. radii are also calculated. Center of mass spurious effects are exactly eliminated and the forementioned nuclear properties are calculated again for 4 He.
3

Avaliação do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensão

Amorim, Arthur Eduardo Alves 09 October 2015 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2015-11-16T18:15:13Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Avaliacao do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensao.pdf: 2595378 bytes, checksum: 555c76d8ac8053bf86c8ee4bdb825fe0 (MD5) / Approved for entry into archive by Morgana Andrade (morgana.andrade@ufes.br) on 2016-01-07T11:06:00Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Avaliacao do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensao.pdf: 2595378 bytes, checksum: 555c76d8ac8053bf86c8ee4bdb825fe0 (MD5) / Made available in DSpace on 2016-01-07T11:06:01Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Avaliacao do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensao.pdf: 2595378 bytes, checksum: 555c76d8ac8053bf86c8ee4bdb825fe0 (MD5) Previous issue date: 2015 / CNPQ / Em um contexto de necessidade de aumento da oferta de energia elétrica e de busca por fontes renováveis e limpas de energia, a energia eólica tem experimentado um crescimento expressivo nos últimos anos. Uma das tecnologias mais empregadas em geradores eólicos, o DFIG, possui como maior susceptibilidade os distúrbios da rede, principalmente o afundamento de tensão. Soluções na topologia e no controle do gerador têm sido propostas para aumento da suportabilidade do gerador a esses fenômenos. Este trabalho avalia a utilização de um limitador de corrente supercondutor resistivo no elo-CC do conversor back-to-back para proteção do conversor e aumento da suportabilidade a afundamentos de tensão em um gerador eólico baseado em DFIG. A aplicação da tecnologia de supercondutores na proteção de sistemas eólicos é recente e os resultados obtidos nesse trabalho contribuem com os estudos feitos na área. Com o gerador DFIG operando em condições normais, o supercondutor não transita para o estado condutor, e permanece invisível à operação. Na ocorrência de um afundamento de tensão na rede a corrente no circuito de rotor aumenta ultrapassando o valor da corrente crítica e levando o supercondutor ao estado condutor, inserindo um elemento resistivo, limitando assim, a corrente. As análises são feitas utilizando o software de simulação de transitórios eletromagnéticos PSCAD/EMTDC com a implementação do limitador supercondutor em uma turbina eólica de 2MW. São avaliados aspectos tais como limitação de corrente, influência na resposta e atendimento à normativa de suportabilidade para duas posições do limitador dentro do elo-CC do conversor back-to-back. Os resultados obtidos demonstram que a inserção do limitador no elo-CC limita a corrente no rotor durante a ocorrência de afundamentos de tensão, ao mesmo tempo em que mantém a tensão do elo-CC em valores seguros, confirmando a validade da proposta. / In a context of necessity to increase electric energy offer and to search clean and renewable energy sources, wind energy have experienced an expressive expansion through the last few years. One of the most employed wind generators, the DFIG, has its performance significantly affected by grid disturbances, especially voltage sag. Topology and control solutions have been presented to increase generator’s supportability to these phenomena. This work verifies the use of superconducting resistive current limiter placed on back-to-back converter DC-link to protect the converter and to increase low voltage ride-through for a DFIG-based wind generator. The application of superconducting technology on wind systems protection is novel and the obtained results contribute with other works in this area. Under DFIG normal operation, the superconductor doesn’t transits to conductor state and remains invisible to the system. During a voltage dip the rotor circuit current surpasses the device critical current turning the superconductor to a conductor state inserting a resistive element, limiting the hazardous current. The studies are made through electromagnetic transient simulation software PSCAD/EMTDC with implementation of a superconducting current limiter on a 2MW wind turbine. Aspects as current limitation, response influence and supportability standard attendance are evaluated for limiter inside back-to-back converter DC-link in two different settings. The obtained results demonstrate that if voltage sag occurs the limiter insertion on DC-link limits the rotor current at the same time that it maintains DC-link voltage in safe values, proving the proposal validly.
4

Vibrações monopolares isoescalares em alguns núcleos duplamente mágicos / Isoscalar monopolar vibrations in some doubly magic nuclei.

Diógenes Galetti 11 August 1978 (has links)
Usamos o formalismo de A. Toledo Pisa e E. Passos, que usa o método de coordenadas geradores e o Teorema Espectral de Anélise Funcional, para obter uma hamiltoniana coletiva para as vibrações monopolares isoescalares nos núcleos duplamente mágicos ANPOT. 4 He, ANPOT. 16 O e ANPOT 40 C. As funções de onda do oscilador hermônico são tomadas como funções de onda geradoras, e a interação de muitos corpos é aquela de Skyrme. Com esta hamiltoniana coletiva calculamos o espectro de energias do modo monopolar isoescalar, parâmetros de inércia e módulos de incompressibilidade para aqueles núcleos e comparamos com os resultados de Flocard e Vautherin, que resolvem numericamente a equação de Griffin-Wheeler. Foram calculados ainda os raios quadráticos médios nucleares. Os efeitos espúrios dos movimentos do centro de massa são eliminados exatamente para o AMPOT. 4 He e recalculamos aquelas propriedades nucleares. / The isoscalar monopole vibrational mode in 4 He,16 O and 40Ca is studied with the aid of collective Hamiltonians obtained from e general formalism proposed by A. Toledo Piza and E. Passos, which makes use of the generator coordinate method and Functional Analisis Spectral Theorem. Cur generator wave functions are that of the harmonic oscillator and use is made of the Skyrme\'s schematic effective interaction. Using the collective Hamiltonian we can calculate the energy spectrum, inertial parameters end incompressibility modulus and compare with numerical results of Flocard and Vautherin. R. m. s. radii are also calculated. Center of mass spurious effects are exactly eliminated and the forementioned nuclear properties are calculated again for 4 He.
5

Controle e integração de centrais eólicas à rede elétrica com geradores de indução duplamente alimentados. / Control and integration of wind farms to the power grid using doubly fed induction generators.

Kleber Freire da Silva 14 March 2006 (has links)
Esta Tese trata do controle e integração de centrais eólicas à rede elétrica interligada, utilizando-se geradores de indução duplamente alimentados (GIDE). O objetivo principal da Tese foi desenvolver estratégias de controle discreto para o sistema de geração eólica, de forma a reduzir os impactos na qualidade da energia gerada, em função dos diversos regimes e transitórios de vento, que podem ocorrer no sítio eólico. Para o projeto do sistema de controle dos geradores foi adotada a técnica do controle vetorial, de forma a desacoplar o controle do fluxo das potências ativa e reativa entre o gerador e a rede elétrica. Visando caracterizar os diversos modos de operação do GIDE, com velocidades acima e abaixo da síncrona, foi desenvolvido um estudo de regime permanente do gerador, obtendo-se os limites de correntes, tensões e demais grandezas elétricas e mecânicas, para uma determinada faixa de velocidade. As principais estratégias de controle atualmente utilizadas pelos fabricantes de turbinas eólicas foram analisadas, destacando-se os aspectos da eficiência energética do conjunto turbina-gerador e da qualidade da energia. O projeto das malhas de controle dos conversores estáticos conectados ao circuito do rotor foi desenvolvido utilizando a técnica de controle discreto, propondo-se as estratégias de controle e o conjunto de especificações para definição dos ganhos dos controladores, objetivando reduzir os impactos na qualidade da energia gerada. Foi analisada a influência da modelagem da turbina com eixos elásticos e eixos rígidos, no comportamento das variáveis controladas. Buscando reduzir os harmônicos de ordem elevada da corrente do gerador, devido à modulação por largura de pulso (PWM) dos conversores estáticos, foi proposta uma estratégia de projeto de filtro passivo LCL, instalado no circuito do rotor. Um programa de simulação no ambiente Matlab/Simulinkâ foi desenvolvido, para análise da interligação de um parque eólico, representado por uma turbina equivalente, ao sistema elétrico de potência reduzido, permitindo estudos de regime permanente e transitório. Com este programa, um estudo de caso foi realizado, avaliando-se o controle e a integração de uma usina eólica de 192MW, conectada na rede básica do sistema interligado nacional, na tensão 230kV. Os resultados obtidos mostram as contribuições, das estratégias de controle propostas, para melhorar o comportamento das tensões do sistema elétrico quando da ocorrência de transitórios de ventos na usina. / This Thesis presents the control and integration of wind farms to the interconnected power grid, using doubly fed induction generators (DFIG). The main objective of the present Thesis was to develop discrete control strategies for the wind generation system, with the goal to reduce the wind variations impacts in the grid power quality. The design technique selected for the generators control system was the vector control technique, which allows independent control of active and reactive power flow between the generator and the grid. In order to characterize the diverse operation modes of the DFIG, below and above the synchronous speed, a generator steady-state study was developed, getting the current and voltage limits and the others electric and mechanical safe limits variables, for one determined speed range. The main control strategies currently used by the wind turbines manufacturers were analyzed, highlighting the aspects of the turbine-generator energy efficiency and the power quality. The control loops design of the static converters was developed using the discrete control technique. It was elaborated the control strategies and also the basic specifications used to define the controllers gains, with the key target to reduce the impacts in the grid power quality caused by the wind variations. Other aspect covered by this work was the influence of the turbine modeling, with rigid shafts and with shafts of a relatively low stiffness, in the control system performance. In a way to reduce high order harmonics in the generator current, caused by the pulse width modulation (PWM) of the static converters, it was proposed a design strategy of a passive LCL filter, installed in the rotor circuit. A simulation program was developed, using the Matlab/SimulinkÔ platform, to analyze the interconnection of a wind farm, represented by a equivalent turbine, to the reduced power electrical system, allowing steady-state and transient studies. With this simulation program, a case study was developed evaluating the control and integration of a 192MW wind farm, connected to 230kV voltage level of the national interconnected power system. The main results reached by this work showed the contributions of the control strategies proposed to improve the electrical system voltages behavior, when wind variations occur in the wind farm.
6

Questionário de frequência alimentar para idosos saudáveis: Validação da ingestão de energia pelo método da água duplamente marcada / Food frequency questionnaire to healthy elderly: Validation of energy intake for using the doubly labeled water

Marchesi, Juliana Cristina Lemos de Souza 15 March 2018 (has links)
Espera-se que entre 2010 e 2050, a população mundial total terá um aumento de 2 bilhões de habitantes, ao passo que a população idosa chegará ao número de 1,3 bilhões de habitantes. Dentre os diversos fatores envolvidos com expectativa de vida longa, está bem estabelecido que o hábito alimentar desempenha um papel central para a saúde, o que torna importante o conhecimento do padrão alimentar nesta faixa etária. Para a avaliação da ingestão alimentar média a longo prazo em grande número de indivíduos, os Questionários de Frequência de Alimentos (QFAs) são instrumentos particularmente importantes. Objetivo: validar um questionário de frequência alimentar para idosos saudáveis. Casuística e Métodos: Participaram da pesquisa 43 idosos independentes, com a capacidade cognitiva e funcional preservadas, de ambos os gêneros, com idades > 60 anos. Foi avaliado o consumo alimentar dos indivíduos por meio de 3 recordatórios alimentares de 24 horas e um questionário de frequência alimentar, com o auxílio de um livro de fotografias para visualização do tamanho das porções dos alimentos. Como método padrão-ouro, foi utilizada a água duplamente marcada (DLW) para aferição do gasto energético total diário. Para a análise estatística, foi realizada análise descritiva dos dados, calculado o coeficiente de correlação de Spearman, construídos gráficos de dispersão e de Bland-Altman, e também o Coeficiente de Correlação Intraclasse (ICC). Foi adotado o nível de significância de 5%. Resultados: foi observada excelente concordância entre o QFA e DLW para estimativa do consumo de energia em mulheres idosas, assim boa correlação entre o R24h e DLW para estimativa do consumo de energia em homens idosos. Não foram encontradas correlações significativas entre o QFA e DLW para estimativa do consumo de energia em ambos os sexos. Conclusão: Considerando que o objetivo desta pesquisa foi validar o QFA para os dois gêneros (homem e mulher), o mesmo não foi alcançado. / Introduction: It is expected that between 2010 and 2050, the total world population will increase by 2 billion inhabitants, while the elderly population will reach 1.3 billion. Among the many factors involved in long life expectancy, it is well established that eating habits play a central role in health, which makes it important to know the food pattern in this age group. For the evaluation of the long-term average food intake in a large number of individuals, Food Frequency Questionnaires (FFQs) are particularly important instruments. Objective: to validate a food frequency questionnaire for healthy elderly. METHODS: Participants were 43 independent, with cognitive and functional capacity, of both genders, aged> 60 years. The individuals\' food consumption was evaluated through three 24-hour recalls and a food frequency questionnaire, with the aid of a photo book to visualize the size of the food portions. As a gold standard method, double-labeled water (DLW) was used to measure total daily energy expenditure. For the statistical analysis, a descriptive analysis of the data was performed, the Spearman correlation coefficient was calculated, the dispersion and Bland-Altman graphs were constructed, as well as the Intraclass Correlation Coefficient (ICC). The significance level of 5% was adopted. Results: excellent concordance was observed between the QFA and DLW for estimation of energy consumption in elderly women, thus a good correlation between R24h and DLW for estimation of energy consumption in elderly men. No significant correlations were found between the QFA and DLW to estimate the energy consumption in both sexes. Conclusion: Considering that the objective of this research was to validate the FFQ for both genders (man and woman), the same was not achieved.
7

Controle e integração de centrais eólicas à rede elétrica com geradores de indução duplamente alimentados. / Control and integration of wind farms to the power grid using doubly fed induction generators.

Silva, Kleber Freire da 14 March 2006 (has links)
Esta Tese trata do controle e integração de centrais eólicas à rede elétrica interligada, utilizando-se geradores de indução duplamente alimentados (GIDE). O objetivo principal da Tese foi desenvolver estratégias de controle discreto para o sistema de geração eólica, de forma a reduzir os impactos na qualidade da energia gerada, em função dos diversos regimes e transitórios de vento, que podem ocorrer no sítio eólico. Para o projeto do sistema de controle dos geradores foi adotada a técnica do controle vetorial, de forma a desacoplar o controle do fluxo das potências ativa e reativa entre o gerador e a rede elétrica. Visando caracterizar os diversos modos de operação do GIDE, com velocidades acima e abaixo da síncrona, foi desenvolvido um estudo de regime permanente do gerador, obtendo-se os limites de correntes, tensões e demais grandezas elétricas e mecânicas, para uma determinada faixa de velocidade. As principais estratégias de controle atualmente utilizadas pelos fabricantes de turbinas eólicas foram analisadas, destacando-se os aspectos da eficiência energética do conjunto turbina-gerador e da qualidade da energia. O projeto das malhas de controle dos conversores estáticos conectados ao circuito do rotor foi desenvolvido utilizando a técnica de controle discreto, propondo-se as estratégias de controle e o conjunto de especificações para definição dos ganhos dos controladores, objetivando reduzir os impactos na qualidade da energia gerada. Foi analisada a influência da modelagem da turbina com eixos elásticos e eixos rígidos, no comportamento das variáveis controladas. Buscando reduzir os harmônicos de ordem elevada da corrente do gerador, devido à modulação por largura de pulso (PWM) dos conversores estáticos, foi proposta uma estratégia de projeto de filtro passivo LCL, instalado no circuito do rotor. Um programa de simulação no ambiente Matlab/Simulinkâ foi desenvolvido, para análise da interligação de um parque eólico, representado por uma turbina equivalente, ao sistema elétrico de potência reduzido, permitindo estudos de regime permanente e transitório. Com este programa, um estudo de caso foi realizado, avaliando-se o controle e a integração de uma usina eólica de 192MW, conectada na rede básica do sistema interligado nacional, na tensão 230kV. Os resultados obtidos mostram as contribuições, das estratégias de controle propostas, para melhorar o comportamento das tensões do sistema elétrico quando da ocorrência de transitórios de ventos na usina. / This Thesis presents the control and integration of wind farms to the interconnected power grid, using doubly fed induction generators (DFIG). The main objective of the present Thesis was to develop discrete control strategies for the wind generation system, with the goal to reduce the wind variations impacts in the grid power quality. The design technique selected for the generators control system was the vector control technique, which allows independent control of active and reactive power flow between the generator and the grid. In order to characterize the diverse operation modes of the DFIG, below and above the synchronous speed, a generator steady-state study was developed, getting the current and voltage limits and the others electric and mechanical safe limits variables, for one determined speed range. The main control strategies currently used by the wind turbines manufacturers were analyzed, highlighting the aspects of the turbine-generator energy efficiency and the power quality. The control loops design of the static converters was developed using the discrete control technique. It was elaborated the control strategies and also the basic specifications used to define the controllers gains, with the key target to reduce the impacts in the grid power quality caused by the wind variations. Other aspect covered by this work was the influence of the turbine modeling, with rigid shafts and with shafts of a relatively low stiffness, in the control system performance. In a way to reduce high order harmonics in the generator current, caused by the pulse width modulation (PWM) of the static converters, it was proposed a design strategy of a passive LCL filter, installed in the rotor circuit. A simulation program was developed, using the Matlab/SimulinkÔ platform, to analyze the interconnection of a wind farm, represented by a equivalent turbine, to the reduced power electrical system, allowing steady-state and transient studies. With this simulation program, a case study was developed evaluating the control and integration of a 192MW wind farm, connected to 230kV voltage level of the national interconnected power system. The main results reached by this work showed the contributions of the control strategies proposed to improve the electrical system voltages behavior, when wind variations occur in the wind farm.
8

Questionário de frequência alimentar para idosos saudáveis: Validação da ingestão de energia pelo método da água duplamente marcada / Food frequency questionnaire to healthy elderly: Validation of energy intake for using the doubly labeled water

Juliana Cristina Lemos de Souza Marchesi 15 March 2018 (has links)
Espera-se que entre 2010 e 2050, a população mundial total terá um aumento de 2 bilhões de habitantes, ao passo que a população idosa chegará ao número de 1,3 bilhões de habitantes. Dentre os diversos fatores envolvidos com expectativa de vida longa, está bem estabelecido que o hábito alimentar desempenha um papel central para a saúde, o que torna importante o conhecimento do padrão alimentar nesta faixa etária. Para a avaliação da ingestão alimentar média a longo prazo em grande número de indivíduos, os Questionários de Frequência de Alimentos (QFAs) são instrumentos particularmente importantes. Objetivo: validar um questionário de frequência alimentar para idosos saudáveis. Casuística e Métodos: Participaram da pesquisa 43 idosos independentes, com a capacidade cognitiva e funcional preservadas, de ambos os gêneros, com idades > 60 anos. Foi avaliado o consumo alimentar dos indivíduos por meio de 3 recordatórios alimentares de 24 horas e um questionário de frequência alimentar, com o auxílio de um livro de fotografias para visualização do tamanho das porções dos alimentos. Como método padrão-ouro, foi utilizada a água duplamente marcada (DLW) para aferição do gasto energético total diário. Para a análise estatística, foi realizada análise descritiva dos dados, calculado o coeficiente de correlação de Spearman, construídos gráficos de dispersão e de Bland-Altman, e também o Coeficiente de Correlação Intraclasse (ICC). Foi adotado o nível de significância de 5%. Resultados: foi observada excelente concordância entre o QFA e DLW para estimativa do consumo de energia em mulheres idosas, assim boa correlação entre o R24h e DLW para estimativa do consumo de energia em homens idosos. Não foram encontradas correlações significativas entre o QFA e DLW para estimativa do consumo de energia em ambos os sexos. Conclusão: Considerando que o objetivo desta pesquisa foi validar o QFA para os dois gêneros (homem e mulher), o mesmo não foi alcançado. / Introduction: It is expected that between 2010 and 2050, the total world population will increase by 2 billion inhabitants, while the elderly population will reach 1.3 billion. Among the many factors involved in long life expectancy, it is well established that eating habits play a central role in health, which makes it important to know the food pattern in this age group. For the evaluation of the long-term average food intake in a large number of individuals, Food Frequency Questionnaires (FFQs) are particularly important instruments. Objective: to validate a food frequency questionnaire for healthy elderly. METHODS: Participants were 43 independent, with cognitive and functional capacity, of both genders, aged> 60 years. The individuals\' food consumption was evaluated through three 24-hour recalls and a food frequency questionnaire, with the aid of a photo book to visualize the size of the food portions. As a gold standard method, double-labeled water (DLW) was used to measure total daily energy expenditure. For the statistical analysis, a descriptive analysis of the data was performed, the Spearman correlation coefficient was calculated, the dispersion and Bland-Altman graphs were constructed, as well as the Intraclass Correlation Coefficient (ICC). The significance level of 5% was adopted. Results: excellent concordance was observed between the QFA and DLW for estimation of energy consumption in elderly women, thus a good correlation between R24h and DLW for estimation of energy consumption in elderly men. No significant correlations were found between the QFA and DLW to estimate the energy consumption in both sexes. Conclusion: Considering that the objective of this research was to validate the FFQ for both genders (man and woman), the same was not achieved.
9

Controle vetorial aplicado à redução das ondulações do torque eletromagnético no gerador de indução duplamente alimentado em sistemas eólicos / Vector control applied to reduction of the electromagnetic torque ripple in the Double-Induced Induction Generator in wind systems

Santana, Marcelo Patrício de 30 August 2017 (has links)
Este trabalho apresenta um sistema de controle com o objetivo de atenuar as ondulações do torque eletromagnético considerando os harmônicos de quinta, sétima, décima primeira e décima terceira ordem da tensão do estator do Gerador de Indução Duplamente Alimentado (GIDA). Dessa maneira, propõe-se a utilização de controladores proporcional-integrativo vetoriais juntamente com um sistema de identificação dos componentes harmônicos da corrente do estator empregando a transformada discreta de Fourier. O trabalho aborda a influência dos harmônicos de quinta, sétima, décima primeira e décima terceira ordem da tensão do estator nos harmônicos da corrente do estator, nas ondulações do torque eletromagnético e nas potências ativa e reativa do estator. Resultados de simulação avaliam o controlador proposto em condições adversas: variações paramétricas e da frequência da rede, além da influência de atrasos na corrente do estator. Finalmente, resultados experimentais validam o sistema proposto. / This work presents a vector controller with the objective of reducing the electromagnetic torque and the active and reactive powers of the stator by means of control of the harmonics of the stator current in harmonic conditions of fifth, seventh, eleventh and thirteenth order of the stator voltage. The objective of the work is to propose a controller that uses two techniques already consolidated in the literature, proportional-integrative and discrete Fourier transform, besides being robust the main disadvantages of the existing harmonic controllers in the literature that are dependencies of the parameters of the machine and the Frequency of the network beyond the influence of the stator current delays on the harmonic controller. First, the influence of the fifth, seventh, eleventh, eleventh and thirteenth order harmonics of the stator voltage on the harmonics of the stator current and on the undulations of the electromagnetic torque and the active and reactive powers of the stator are studied. Next, simulation results evaluate the proposed controller under adverse conditions: parametric variations and the frequency of the network, besides the influence of stator current delays. Finally, experimental results validate the controller under conditions that the controller reference is nonzero.
10

Efeitos da dupla listagem internacional: uma análise das empresas brasileiras emitentes de depositary receipts em tempos de crise financeira internacional / Effects of international cross-listing: an analysis of the Brasilian companies issuers of depositary receipts in times of internacional financial crisis

Queiroz, Lísia de Melo 31 July 2015 (has links)
A dupla listagem é uma estratégia que supostamente pode minimizar os efeitos de uma crise financeira internacional sobre as empresas. Este estudo buscou analisar se esta suposição é válida para companhias brasileiras, no contexto da crise de 2008. O problema de pesquisa que direcionou este estudo foi: A dupla listagem internacional fez com que os impactos da crise financeira de 2008 sobre determinados indicadores das empresas fossem compatíveis com os previstos na literatura e fossem diferentes daqueles sofridos pelas empresas domésticas? O objetivo foi analisar se a dupla listagem pode minimizar os efeitos gerados pela crise financeira de 2008 sobre determinados indicadores associados às empresas listadas. Os efeitos da crise de 2008 foram também comparados com os sofridos pelos papéis de empresas domésticas, sem dupla listagem. Os indicadores analisados foram: liquidez, volume, risco, retorno, custo de capital, alavancagem financeira, valor da empresa e concorrência. O teste de hipóteses foi utilizado para verificar se houve impacto significativo nas variáveis das empresas antes e após a crise financeira. Foram utilizadas para a amostra 37 empresas duplamente listadas (EDL) e 37 empresas domésticas (ED). Os resultados obtidos com o estudo sugerem que, durante uma crise financeira internacional, a maioria dos indicadores das EDL apresenta diferença significativa quando comparados os períodos pré e pós-crise. Os resultados das empresas domésticas foram semelhantes. Estes resultados estão em consonância com os apresentados nos estudos de Bailey, Chan e Chung (2000), Huang e Stoll (2001), Bin, Blenman e Chen (2004), mas contradizem os resultados de Huang e Stoll (2001). Em relação às diferenças entre os dois grupos de empresas Chandar, Patro e Yezegel (2009) afirmam que empresas com dupla listagem ficaram mais protegidas no período da crise; porém, Chira e Marciniak (2014) comprovaram que por serem duplamente listadas as empresas ficaram mais expostas durante as crises financeiras. As duas conclusões principais do estudo são que a crise afetou de forma semelhante os dois grupos de empresas e que, portanto, a dupla listagem não minimizou seus efeitos / The cross-listing is a strategy that supposedly can minimize the effects of an international financial crisis on businesses. This study sought to analyze if this supposition is valid for Brazilian companies, in the context of the crisis of 2008. The research problem that directed this study was: The international cross-listing has meant that the impact of the financial crisis of 2008 on certain indicators of the companies were compatible with the expected in the literature and were different from those experienced by domestic firms? The objective was to analyze if the cross-listing can minimize the effects generated by the 2008 financial crisis on certain indicators associated with listed companies. The effects of the 2008 crisis were also compared with those suffered by the papers of domestic companies, without cross-listing. The indicators analyzed were: liquidity, scale, risk and return, cost of capital, financial leverage, firm\'s value and competitors. The hypothesis testing was used to verify if there was significant impact on the variables of enterprises before and after the financial crisis. The hypothesis testing was used to verify if there was significant impact on the variables of enterprises before and after the financial crisis. They were used for the sample 37 cross-listed firms (CLF) and 37 domestic firms (DF). The results of the study suggest that, during an international financial crisis, most of the indicators of the CLF presents significant difference when compared to the periods before and after the crisis. The results of domestic companies were similar. These results are consistent with those presented in studies by Bailey, Chan and Chung (2000), Huang and Stoll (2001), Bin, Blenman and Chen (2004), but contradict the results by Huang and Stoll (2001). Regarding the differences between the two groups of companies Chandar, Patro and Yezegel (2009) state that companies with cross-listing were more protected in times of crisis; however, Chira and Marciniak (2014) confirmed that cross-listed companies were more exposed during the financial crisis. The two principal conclusions of the study are that the crisis affected in a similar manner both groups of companies and, therefore, the cross-listing did not minimize their effects

Page generated in 0.0843 seconds