Seismic damage avoidance design of warehouse buildings constructed using precast hollow core panels

Abdul Hamid, Nor Hayati January 2006 (has links)
Precast prestressed hollow core units are commonly used in the construction of the flooring system in precast buildings. These units without transverse reinforcement bars are designed to resist seismic loading as replacement for fixed-base precast wall panels in the construction of warehouse buildings. Thus, this research seeks to investigate the seismic performance of the units constructed as a subassemblage (single wall) subjected to biaxial loading and as a superassemblage (multi-panel) subjected to quasi-static lateral loading. A design procedure for warehouse building using precast hollow core walls under Damage Avoidance Design (DAD) is proposed. In addition, a risk assessment under Performance-Based Earthquake Engineering (PBEE) is evaluated using the latest computational tool known as Incremental Dynamic Analysis (IDA). A comparative risk assessment between precast hollow core walls and fixed-base monolithic precast wall panels is also performed. Experimental results demonstrate that rocking precast hollow core walls with steelarmouring do not suffer any non-structural damage up to 2.0% drift and minor structural damage at 4.0% drift. Results revealed that the wall with unbonded fuse-bars and 50% initial prestressing of unbonded tendons performed the best compared with other types of energy dissipators. Furthermore, 12mm diameter of fuse-bar is recommended as there is no uplifting of the foundation beam during ground shaking. Hence, this type of energy dissipator is used for the construction of seismic wall panels in warehouse buildings. One of the significant findings is that the capacity reduction factor (Ø ) which relates to global uncertainty of seismic performance is approximately equal to 0.6. This value can be used to estimate the 90th percentile of the structures without performing IDA. Therefore, the structural engineers are only required to compute Rapid-IDA curve along with the proposed design procedure.

Page generated in 0.1223 seconds