• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5783
  • 109
  • 97
  • 84
  • 84
  • 83
  • 55
  • 37
  • 29
  • 21
  • 21
  • 18
  • 3
  • 3
  • 1
  • Tagged with
  • 6029
  • 3373
  • 2538
  • 1559
  • 1414
  • 1184
  • 959
  • 777
  • 749
  • 729
  • 672
  • 662
  • 615
  • 611
  • 525
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Expansão do sistema de transmissão de energia elétrica no Brasil / Expansion of the electrical energy transmission system in Brazil

Vieira, Isabela Sales 04 1900 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2009. / Submitted by Larissa Ferreira dos Angelos (ferreirangelos@gmail.com) on 2010-03-23T15:22:17Z No. of bitstreams: 1 2009_IsabelaSalesVieira.pdf: 1033055 bytes, checksum: 539710caf8047b67346fc0326a52d58f (MD5) / Approved for entry into archive by Daniel Ribeiro(daniel@bce.unb.br) on 2010-04-01T01:22:17Z (GMT) No. of bitstreams: 1 2009_IsabelaSalesVieira.pdf: 1033055 bytes, checksum: 539710caf8047b67346fc0326a52d58f (MD5) / Made available in DSpace on 2010-04-01T01:22:17Z (GMT). No. of bitstreams: 1 2009_IsabelaSalesVieira.pdf: 1033055 bytes, checksum: 539710caf8047b67346fc0326a52d58f (MD5) Previous issue date: 2009-04 / O sistema de transmissão de energia elétrica no Brasil tem grande importância para o atendimento às cargas e para a confiabilidade do sistema elétrico nacional. A grande extensão do país exige um sistema de transmissão de grande dimensão, capaz de interligar a geração e a carga das diversas regiões geográficas, otimizando a operação do sistema. Este trabalho apresenta um estudo sobre a expansão do sistema de transmissão e a análise econômica desta expansão, especialmente quanto às interligações inter-regionais, devido à importância de tais instalações para o Sistema Interligado Nacional – SIN. As interligações inter-regionais integram os subsistemas do SIN, possibilitando o melhor aproveitamento da capacidade de geração, e representam mais de 25% da Receita Anual Permitida – RAP associada às instalações de transmissão. O custo médio das interligações inter-regionais, em R$/MWh, e o Índice Custo-Benefício apresentados neste trabalho foram utilizados para avaliar a viabilidade econômica destas instalações de transmissão. O trabalho também apresenta a evolução da RAP entre os anos 2000 e 2008, a qual aumentou cerca de 370%, influenciada por fatores como a correção monetária pelo Índice Geral de Preços do Mercado – IGP-M e a diferença entre os valores de receita associados às instalações antigas e a RAP associada às novas instalações de transmissão. ________________________________________________________________________________________ ABSTRACT / The electrical energy transmission system in Brazil is of great importance for market service and for the reliability of the national electrical system. The vast expanse of the country demands a transmission system of large proportions, one that is capable of interconnecting the generation and the charge of the diverse geographic regions; thus, optimizing the operation of the system. This paper presents a study on the expansion of the transmission system and the economic analysis of such expansion, especially in reference to interregional interconnections due to the importance of these installations to the National Interconnected System (Sistema Interligado Nacional - SIN). The interregional interconnections merge the subsystems of SIN, allowing for the best possible utilization of generation capability and represent more than 25% of the Allowed Annual Revenue (Receita Anual Permitida - RAP) associated with the transmission installations. The average cost of the interregional interconnections, in R$/MWh, and the presented Cost-Benefit Index in this paper were used to evaluate the economic viability of these transmission installations. Furthermore, the paper shows the evolution of the Allowed Annual Revenue between the years 2000 and 2008, which increased by about 370%, and was influenced by factors such as the indexation by the General Market Price Index (Índice Geral de Preços do Mercado - IGP-M) and the difference between the revenue values associated with the old installations and the RAP associated with the new transmission installations.
62

Dupla ótica sobre a comparação da eficiência de empresas de transmissão de energia elétrica / Double perspective-data analysis in the comparison of electrical energy transmission company efficiency

Sampaio, Lanier Peterson Castelo Branco 17 August 2011 (has links)
Tese (doutorado)—Universidade de Brasília, Programa de Pós-Graduação em Engenharia Elétrica, 2011. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2011-11-30T13:05:14Z No. of bitstreams: 1 2011_LanierPetersonCasteloBrancoSampaio.pdf: 1599431 bytes, checksum: 9025d4c2c06b303452ca6d3d56923cd0 (MD5) / Approved for entry into archive by LUCIANA SETUBAL MARQUES DA SILVA(lucianasetubal@bce.unb.br) on 2011-12-05T14:59:26Z (GMT) No. of bitstreams: 1 2011_LanierPetersonCasteloBrancoSampaio.pdf: 1599431 bytes, checksum: 9025d4c2c06b303452ca6d3d56923cd0 (MD5) / Made available in DSpace on 2011-12-05T14:59:26Z (GMT). No. of bitstreams: 1 2011_LanierPetersonCasteloBrancoSampaio.pdf: 1599431 bytes, checksum: 9025d4c2c06b303452ca6d3d56923cd0 (MD5) / Modelos DEA (Data Envelopment Analysis) são amplamente utilizados no processo de benchmarking de indicadores de produção. O método DEA exige uma série de prérequisitos relacionados, por exemplo, à quantidade de indicadores e homogeneidade da amostra para seu uso, caso contrário, sua aplicação direta não é recomendada. O objetivo do trabalho é desenvolver uma metodologia de comparação de eficiência entre unidades de produção, baseada em DEA, para ser aplicada nos casos em que o procedimento envolve um número reduzido de amostras, grande quantidade de indicadores, conjuntos não-homogêneos e interesses conflitantes. Para isto são criados índices onde é possível compactar as informações relevantes de um grupo de indicadores que representam o enfoque econômico, a qualidade do serviço e a posição socioambiental assumida pelas empresas. É proposta a aplicação da Envoltória sob Dupla Ótica (EDO) para obter um conjunto competitivo que identifique a eficiência levando em consideração as diversas perspectivas. São utilizados dois modelos DEA obtendo uma fronteira normal e uma invertida, onde é calculada a distância entre as mesmas e identificadas as características do conjunto. Iniciase o processo de retirada das camadas externas mais influentes. O conceito é aplicado de forma inovadora a uma situação real no setor de transmissão de energia elétrica no Brasil. Os resultados demonstram que o método EDO complementa e valida o método DEA tradicional modelando a imperfeição e o poder do mercado, fornecendo graus de liberdade para negociação e melhoria contínua, contribuindo para auxiliar a manutenção do equilíbrio entre os diversos agentes envolvidos de forma transparente, sem eliminar o incentivo para a redução dos custos operacionais, aumento dos lucros e transferência dos ganhos de eficiência para o consumidor, assegurando a segurança do suprimento de energia elétrica e a qualidade dos serviços. Por fim, é empregada uma adaptação da teoria da Economia da Experiência como proposta para a fase após o DEA, ou seja, as ações de melhoria do desempenho. ______________________________________________________________________________ ABSTRACT / DEA models are widely used in the benchmarking process of strategic production indicators. The DEA methodology requires a series of prerequisites related, for example, the number of indicators and homogeneity of the sample for use, otherwise its direct application is not recommended. The objective of this study is to develop a methodology to compare the efficiency of production units, based on DEA, to be applied in cases where the procedure involves a small number of samples, large number of indicators, non-homogeneous sets and divergent interests. To do this, indexes are created where it is possible to compact the relevant information from a group of indicators that represent economic focus, quality of service and the socio-environmental position assumed by the companies. This paper proposes applying Double Perspective- Data Envelopment Analysis to obtain a competitive set that satisfies the objectives taking into consideration diverse points of view. Two DEA models are utilized, obtaining a normal and an inverted frontier, where the distance between them is calculated and the characteristics of the set are identified. A process of removing the most influential layers is initiated. The concept is innovatively applied to a real situation in Brazil’s electric energy transmission sector. The results demonstrate that the DP-DEA method complements and validates the traditional DEA approach, modeling the imperfections and market power, providing degrees of freedom for negotiation and continued improvements, contributing to aiding in maintaining the balance among the various agents involved, transparently, without eliminating the incentive to reduce operational costs, while assuring the security of the electric energy supply as well as the quality of services. Finally, an adaptation of the theory of Experimental Economics is employed as a proposal for the phase after DEA, actions for improvement have been taken.
63

Otimização da operação energetica do sistema hidroeletrica do Rio Iguaçu

Ferreira, Luiz Roberto Morgenstern 12 July 1991 (has links)
Orientador : Chistiano Lyra Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-14T00:25:50Z (GMT). No. of bitstreams: 1 Ferreira_LuizRobertoMorgenstern_M.pdf: 3809059 bytes, checksum: 750d5cb024baf3fe31815628a1256a20 (MD5) Previous issue date: 1991 / Resumo: Este trabalho apresenta a otimização da operação da cascata de aproveitamentos hidroelétricos do rio Iguaçu. Essa cascata é formada por quatro usinas, pertencentes a duas empresas distintas ( COPEL e ELETROSUL). As caracteristicas particulares da cascata do Iguaçu, onde as quedas de algumas usinas são reduzidas pela operação dos reservatórios de jusante, dificultam a obtenção de um consenso quanto à forma de operação. Programação Dinâmica e Otimização Multiobjetivo são usadas na abordagem do problema. Os resultados computacionaismostram a possibilidade de se obter ganhos energéticos com a adoção de regras operativas não convencionais, especificaspara esta cascata de usinas / Abstract: This work presents the optimal operation of the Iguaçu cascade, comprising four hidro plants holded by two different companies (COPEL and ELETROSUL ). The peculiar features of this cascade, where the head of some plants can be reduced by the operation of the downstreans reservoirs, adds difficulties to a consensus about operation policy. Dynamic Programming and Multiobjective Optimization are adopt to deal with the problem. The case study indicates the possibility of obtainning gains with the adoption of non-conventional operation rules / Mestrado / Mestre em Engenharia Elétrica
64

Equivalentes estaticos para sistemas de energia eletrica

Deckmann, Sigmar Maurer, 1946- 14 July 2018 (has links)
Orientador : Alcir Jose Monticelli / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-14T10:08:50Z (GMT). No. of bitstreams: 1 Deckmann_SigmarMaurer_D.pdf: 2919977 bytes, checksum: 0d46dfab1b5ea999ab6ab3a82638c61d (MD5) Previous issue date: 1979 / Resumo: Neste trabalho são discutidos equivalentes estáticos para representar partes de sistemas de energia elétrica. Técnicas convencionais de redução, tais como transformações y-? e equivalentes generalizados Thevenin-Norton não têm levado a resultados satisfatórios, devido às características não-lineares do sistema de transmissão e distribuição. Métodos especiais de redução são apresentados e testados, inclusive para o sistema Sudeste brasileiro. Com equivalentes estáticas, os problemas afetos ao planejamento e ã operação do sistema são reduzidos às dimensões da área de maior interesse para estudo. Isto representa um estímulo à utilização de mini-computadores na análise de grandes sistemas. Nas novas aplicações de controle em tempo real, a representação das partes não-observáveis através de equivalentes externos, permite simular diferentes condições de operação, entre elas a importante análise de segurança estática / Abstract: Static equivalent models are considered for electric power system representation. Normal reduction methods, such as y-? transformation and generalized Thevenin-Norton equivalents, suffer from inaccuracies due to system non-linearities. Special reduction methods are discussed and tested, also for the Brazilian Southeast system. Static equivalents turn it possible to reduce the planning or operational problems to a more convenient study system size. This also represents for introducing mini-computers on large power system analysis. In the recent applications on real-time control, the representation for non-observable parts by static equivalents, is essential to perform the static security analysis / Doutorado / Doutor em Engenharia Elétrica
65

Analise e projeto de auto-regulação paracircuitos trifasicos tiristorizados

Oliveira, Tyrone Dias de 07 August 1989 (has links)
Orientador: Daniel Wisnivesky / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-13T21:50:05Z (GMT). No. of bitstreams: 1 Oliveira_TyroneDiasde_M.pdf: 17783511 bytes, checksum: bfb218f81fb49a54a4bf1c6255af013d (MD5) Previous issue date: 1989 / Resumo: Não informado / Abstract: In this work we present a mathematical moddeling and experimental results on the performance of a six pulse thiristor converter using a fast feed forward method based on the crossing cosine wave with a de reference voltage to determine the firing time for each thyristor. Unbalance mains phase voltage are corrected by a method which advances or delays the firing angle of each thyristor so as to output voltage constant. The results obtained using the propoused method gives a 0.2 percent regulation for the 10 percent amplitude variation of Iine voltage and 0.5 percent voltage variation for 10 percent voltage unbalaneed percent between the three phases / Mestrado / Mestre em Engenharia Elétrica
66

Planejamento a longo prazo em sistemas de distribuição de energia eletrica

Silva, Marcos Carneiro da 20 August 1990 (has links)
Orientador: Paulo Morelato França / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Energia Eletrica / Made available in DSpace on 2018-07-13T21:50:17Z (GMT). No. of bitstreams: 1 Silva_MarcosCarneiroda_D.pdf: 2766291 bytes, checksum: b04c93a05e15f0789dce329f3fc0f84c (MD5) Previous issue date: 1990 / Resumo: Esta dissertação apresenta uma nova proposta metodológica para o Planejamento da Expansão dos Sistemas de Distribuição de Energia Elétrica. Os problemas referentes à rede primária e à rede secundária são tratados de forma hierárquica. As alternativas de expansão das redes são delineadas através da resolução de modelos matemáticos baseados na teoria de otimização de sistemas. O modelo da rede primária compreende simultaneamente os problemas de localizar e dimensionar as subestações e de rotear os alimentadores. Consideram-se os custos fixos das subestações a dos alimentadores novos, bem como de suas ampliações. O custo variável das perdas é tratado de forma quadrática. Um eficiente algoritmo de enumeração implícita é usado para resolver o problema. A radialidade da rede é obtida por meio de heurísticas que trabalham com o custo real. Para a rede secundária é proposta uma metodologia em três etapas seqüenciais: na primeira localizam-se transformadores, depois definem-se as rotas dos alimentadores secundários e, por fim, decide-se a interligação entre as redes primária e secundária. Essas etapas são resolvidas de forma otimizada através da solução dos clássicos problemas das p-medlanas, de localização quadrático e de Steiner, respectivamente. A metodologia é testada em um exemplo real e são feitas comparações qualitativas e quantitativas com o enfoque normalmente empregado para propor alternativas de expansão. / Abstract: This thesis presents a new methodological approach for Electric Energy Distribution Systems Expansion Planning. The problems related to primary and secondary networks are treated in a hierarchical model. In the primary system the aspects of location and sizing of substations as well as feeders routing are considered simultaneously. The model includes fixed costs of new substation and feeders and also their expansions. The variable costs of losses receives a quadratic approach. An efficient Branch and Bound algorithm is utilized in problem solving. Network radiality is obtained through heuristic methods, which work under real cost function. On the secondary network, a heuristic procedure was developed which sequentially enumerates transformers and for each one of these configurations it studies in an optimized manner the transformers location, the secondary feeders routing and primary feeders and transformers interconnect on. These three phases were modeled respectively as p-medians, quadratic facilities location problem and Steiner's problem. / Doutorado / Doutor em Engenharia Elétrica
67

Minimização de perdas em sistemas de energia eletrica

Murari, Carlos Alberto Favarin, 1950- 15 July 2018 (has links)
Orientador: Alcir Jose Monticelli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação. / Made available in DSpace on 2018-07-15T17:52:42Z (GMT). No. of bitstreams: 1 Murari_CarlosAlbertoFavarin_M.pdf: 1741952 bytes, checksum: 2b4c3842b9019f42c5fd74027587ebc7 (MD5) Previous issue date: 1980 / Resumo: Neste trabalho é apresentada uma visão crítica do método Dommel-Tynney aplicado ao problema de controle reativo/tensão (minimização de perdas). Adota-se uma versão do método da matriz Hessiana e compara-se o seu bom desempenho em relação a outros métodos de cálculo de fluxo de carga ótimo. São apresentados resultados obtidos com o Sistema Interligado da Região Sudeste do Brasil (645 barras, 1019 linhas e 81 variáveis de controle). / Abstract: Not informed. / Mestrado / Mestre em Engenharia Elétrica
68

Processamento de erros grosseiros na estimação estatica de estado em sistemas de energia eletrica

Tanaka, Marcia Reimi, 1956- 21 November 1985 (has links)
Orientador: Ariovaldo V. Garcia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-17T05:59:18Z (GMT). No. of bitstreams: 1 Tanaka_MarciaReimi_M.pdf: 840419 bytes, checksum: b1765933853ac82ed1792376663a1618 (MD5) Previous issue date: 1985 / Resumo: Neste trabalho é feita uma avaliação do desempenho de alguns métodos para processamento de erros grosseiros, quando aplicados juntamente com o Estimador de Estado Clássico (WLS) ou com o Estimador Desacoplado Rápido. Propõe-se uma nova maneira de se obter o limiar de decisão no teste de hipótese realizado no processamento de erros grosseiros pelos resíduos normalizados. / Abstract: Not informed. / Mestrado / Mestre em Engenharia Elétrica
69

Um modelo heuristico para solução do problema de planejamento de reativos em sistemas de energia eletrica

Mantovani, Jose Roberto Sanches 15 February 1995 (has links)
Orientador: Ariovaldo Verandio Garcia / Tese (doutorado) - Universidade Estadual de Campinas. Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-19T23:40:56Z (GMT). No. of bitstreams: 1 Mantovani_JoseRobertoSanches_D.pdf: 6055172 bytes, checksum: 520f5722a9ab589c098d210413b0065d (MD5) Previous issue date: 1994 / Resumo: Neste trabalho apresenta-se a formulação geral do problema de planejamento de reativos em sistemas de energia elétrica. As restrições de igualdade - equações estáticas do fluxo de carga, são linearizadas em torno de um ponto de Q peração e o problema passa a ser analisado como um problema de programação linear de grande porte. As restrições de desigualdade consideradas são os limites nas magnitudes das tensões e os limites nas gerações de reativos. A matriz Jacobiano Reativo ?LCRIC? é usada como sensibilidade para o processo de otimização. Através da preparação adequada dos dados d~ fini-se o conjunto de barras candidatas à alocação de novas fontes reativas, podendo fazer parte deste conjunto todas as barras do sistema. o método proposto neste trabalho fornece a localização e a capacidade das fontes reativas que devem ser alocadas no sistema para atender às restrições de operaçao. Não havendo necessidade de novas fontes, obtém-se um ponto viável de operação para o sistema considerando as fontes reatiyas existentes (despacho reativo). Apresentam-se resultados obtidos com a simulação de dois sistemas testes: IEEE30 e IEEE118 / Abstract: Not informed. / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
70

Uma plataforma para análise e localização de faltas em sistemas de transmissão

Venturi, Cristiano, 1987-, Mustafa, Thair Ibrahim Abdel Hamid, 1967-, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Elétrica. January 2015 (has links) (PDF)
Orientador: Thair Ibrahim Abdel Hamid Mustafa. / Dissertação (Mestrado em Engenharia Elétrica) - Programa de Pós-Graduação em Engenharia Elétrica, Centro de Ciências Tecnológicas, Universidade Regional de Blumenau, Blumenau.

Page generated in 0.1019 seconds