• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • 10
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 64
  • 64
  • 20
  • 18
  • 17
  • 14
  • 10
  • 10
  • 10
  • 9
  • 9
  • 8
  • 7
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Contraintes et conséquences électromécaniques liées au passage d'une intensité de courant dans les structures en câbles

Lilien, J. L. January 1983 (has links)
Thesis (Ph. D.)--Université de Liège. / Includes bibliographical references (p. 243-263).
22

The integration of a high voltage cable fault location instrument with modern information technology

Kelly, Roger James January 2002 (has links)
Dissertation submitted in compliance with the requirements for Master's Degree in Technology: Electrical Engineering (Light Current), Durban Institute of Technology, 2002. / Modern society as a whole seems destined to have an ever-increasing demand for power for both industrial and domestic use, as continued population growth means that cities, suburbs and industrial areas become larger and denser. At the same time the trend toward increased productivity in all segments of industry is influencing the development and techniques employed at locating faults in power cables and networks to ensure only limited downtime and reduced direct and indirect costs associated with the location of faults / M
23

Determination of Failure Criteria for Electric Cables Exposed to Fire for Use in a Nuclear Power Plant Risk Analysis

Murphy, Jill E. 14 January 2004 (has links)
The vulnerability of electrical cables exposed to a fire environment is of particular concern to the nuclear power plant community. The community is interested in data that could be used for predicting cable failures during a fire situation. For this reason, a cable test program was conducted using two different types of cable insulation. Several different exposure heat fluxes were tested, as well as different test arrangements such as cable trays and conduits. The program revealed that a single failure temperature for all cable types is not recommended, but if it is necessary a reasonable temperature could be chosen for the thermosets tested in this project.
24

Thermal resistance effects in underground power cable bundles

Foo, Pik-yue, 傅必雨 January 1969 (has links)
published_or_final_version / Electrical Engineering / Master / Master of Science in Engineering
25

A statistical method for establishing insulated cable clearances in large power transformers

Lanoue, Thomas J. January 1975 (has links)
The relationship between impulse breakdown stress and stressed oil volume has been extensively investigated for uniform field electrodes. In large high voltage transformers it is essential to extend this relationship to paper insulated non-uniform field situations which are more frequently encountered in practice. This paper develops the stated relationship by experimental tests, using insulated cable to plane configurations, and statistical methods. These tests show that the impulse breakdown strength of an insulated cable to plane or nonuniform field system has a two parameter Weibull distribution, when the oil is considered to be the weak-link of the system. A non-linear regression analysis is then used to find that the Weibull parameters for insulated non-uniform field electrodes are approximately the same as the parameters for the uninsulated uniform field electrodes provided their stressed oil volumes are equivalent. Statistical calculations are used to derive the fundamental relationship between the Weibull parameters for any stressed oil volume and the Weibull parameters for the unit oil volume. With this relationship it is possible for design engineers to approximately determine the probability of electrical breakdown of any insulated cable to plane configuration in large power transformers.
26

Certain aspects concerning the thermal environment of underground power cables /

Halfter, N. A., January 1972 (has links)
Thesis (Ph. D.)--University of Hong Kong. / Mimeographed.
27

Thermal resistance effects in underground power cable bundles.

Foo, Pik-yue, January 1969 (has links)
Thesis--M. Sc.(Eng.), University of Hong Kong. / Mimeographed.
28

Certain aspects concerning the thermal environment of underground power cables

Halfter, N. A. January 1972 (has links)
published_or_final_version / Electrical Engineering / Doctoral / Doctor of Philosophy
29

Impulse breatdown voltage-time characteristics of compressed SF6 and SF6-N2 insulation

Eteiba, Magdy B. January 1981 (has links)
The thesis constitutes a systematic theoretical and experimental investigation into impulse breakdown voltage-time curves of coaxial-cylinder gaps in SF(,6) and a 50% SF(,6) - 50% N(,2) mixture. The breakdown time delay probability is treated as a bivariate distribution in statistical and formative time lags. A method is developed to deduce the marginal breakdown voltage probability curve from statistics of time delay. The experimental work was performed on 2.54/7.0-cm diameter, 60-cm long coaxial-cylinder electrodes using SF(,6) or SF(,6)-N(,2) mixtures at pressures of 0.1 - 0.3 MPa subjected to 0.5/50-(mu)s and 1.2/50-(mu)s impulses of both polarities. The effect of a spherical conducting particle attached to the central electrode of the coaxial-cylinder gap on the voltage-time characteristics is also investigated.
30

Effect of ADLash opitical fibre cable on corona onset gradient and electric fields around the shield wire of the Apollo-Cahora Bassa HVDC line.

Bussy, Eamon Riccardo. January 2005 (has links)
ADLash® is the trade name for an optical fibre cable attached to a transmission line shield wire using aramid-reinforced bands. The installation of this type of optic fibre cable has been considered for the HVDC line from the Songo hydroelectric scheme at Cahora Bassa in Mozambique, to Apollo substation in South Africa. The impact that installation of this cable will have on the onset of corona is examined. The shield wire with and without ADLash attached is modelled for both the actual line configuration and for corona cage studies. The electric field is calculated using the Method of Images and the Boundary Element Method to predict the electric field enhancements and to estimate the corona onset gradient. Corona onset gradients and phenomena for smooth and stranded conductors are researched to aid the prediction of voltage onset magnitudes for the corona cage. Estimated values are compared with observed values for both AC and DC applied voltages. Different patterns of corona and different corona onset voltages are observed for AC and negative DC applied voltages. The relative permittivity of the ADLash is higher than the surrounding air and this is shown to lead to greatly enhanced electric fields at the air/ dielectric/ shield wire interfaces that are significant enough to cause corona at the rated operating voltage. The corona will bombard the ADLash and probably damage it. Some alternative methods of installing fibre optic cables are reviewed for further research because the use of ADLash cannot be recommended. / Thesis (M.Sc.)-University of KwaZulu-Natal, Durban, 2005.

Page generated in 0.0487 seconds