Spelling suggestions: "subject:"electrical current.""
251 |
A comparative study of capacitor voltage balancing techniques for flying capacitor multi-level power electronic convertersYadhati, Vennela, January 2010 (has links) (PDF)
Thesis (M.S.)--Missouri University of Science and Technology, 2010. / Vita. The entire thesis text is included in file. Title from title screen of thesis/dissertation PDF file (viewed July 26, 2010) Includes bibliographical references (p. 96-102).
|
252 |
The thermoelectrostatic energy converterVliet, Daniel Hendricks, January 1965 (has links)
Thesis (Ph. D.)--University of Wisconsin--Madison, 1965. / Typescript. Vita. Description based on print version record. Includes bibliographical references.
|
253 |
Application of advanced power electronics in renewable energy sources and hybrid generating systemsEsmaili, Gholamreza, January 2006 (has links)
Thesis (Ph. D.)--Ohio State University, 2006. / Title from first page of PDF file. Includes bibliographical references (p. 140-147).
|
254 |
FACTS device modelling in the harmonic domain : a thesis presented for the degree of Doctor of Philosophy in Electrical and Electronic Engineering at the University of Canterbury, Christchurch, New Zealand /Collins, Christopher Donald. January 1900 (has links)
Thesis (Ph. D.)--University of Canterbury, 2006. / Typescript (photocopy). "April 2006." Includes bibliographical references (p. [117]-121). Also available via the World Wide Web.
|
255 |
Multi level reinjection ac/dc converters for HVDC : a thesis presented for the degree of Doctor of Philosophy in Electrical and Computer Engineering at the University of Canterbury, Christchurch, New Zealand /Perera, Lasantha Bernard. January 1900 (has links)
Thesis (Ph. D.)--University of Canterbury, 2006. / Typescript (photocopy). "February 2006." Includes bibliographical references (p. [151]-160). Also available via the World Wide Web.
|
256 |
A novel control design for a wave energy converter /Schacher, Alphonse A. January 1900 (has links)
Thesis (M.S.)--Oregon State University, 2008. / Printout. Includes bibliographical references (leaves 96-97). Also available on the World Wide Web.
|
257 |
Opportunities for in-line, transistorbased technologies on MV and LV power distribution networksMeyer, Bernard 12 1900 (has links)
Thesis (MScEng)--University of Stellenbosch, 2000. / ENGLISH ABSTRACT: Once more opportunities exist for innovative technologies to be applied on MV and LV
power distribution networks to meet the new challenges set by government through its
National Electrification Programme (NEP) to electrify a further 2,5 million households of
which a large majority are in low-density rural areas. Electronic means of voltage
compensation of long MV and LV networks supplying these low-density rural areas are now
possible in the form of electronic voltage regulators mounted on the secondary side of
distribution transformers and service connection boxes along the LV feeders.
Furthermore, it is now possible to provide remote rural agricultural customers with singlephase
supplies supported by end-use technologies in the form of electronic phase converters
that eliminate the need for three-phase supplies. This hybrid of supply- and end-use
technologies together with Eskom's "self-build" policy has made the dream of Eskom grid
power a reality. / AFRIKAANSE OPSOMMING: Nuwe geleenthede het na yore getree vir die toepassing van innoverende tegnologie op
medium- en laagspannings netwerke in antwoord op die uitdagings gestel deur die regering in
die vorm van die Nasionale Elektrifiseringsprogram (NEP). Die elektrifisering van 'n verdere
2,5 miljoen huishoudings waarvan die grootste gedeelte in yl bevolkte plattelandse gebiede is,
word in vooruitsig gestel. Spanningskompensasie van lang laag- en mediumspannings
netwerke word nou moontlik gemaak deur middel van elektroniese spanningsreguleerders,
gemonteer aan die sekondere kant van distribusie transformators en in diensaansluitingskaste
op laagspannings voerders.
Verder is dit ook nou moontlik om afgelee landelike plase met enkelfase krag, gerugsteun
deur eindverbruik tegnologie in die vorm van elektroniese fase omsetters, te voorsien. Die
beskikbaarheid van hierdie tegnologie elimineer die vraag na drie-fase krag. Hierdie hibriede
kombinasie van toevoer- en eindverbruik tegnologie in kohesie met die selfbou beleid van
Eskom, maak dit moontlik dat 'n droom van Eskom voorsiende elektrisiteit, in 'n werklikheid
omskep word.
|
258 |
Analysis and synthesis of an active resonant snubber for high-power IGBT convertersCombrink, Frederik Wilhelm 12 1900 (has links)
Thesis (MScEng)--University of Stellenbosch, 2001. / ENGLISH ABSTRACT: This thesis describes the study of two soft-switching inverter topologies that are well suited to
high-power applications. For the first topology, namely an active resonant turn-off snubber,
the existing theory is expanded with a detailed study into operation strategies and topology
protection.
This is followed by an investigation into the second topology, which is a combined snubber
that reduces both turn-off and turn-on losses. The investigation involves a detailed analysis of
the losses in the snubber components and main devices, as well as a study into the effects of
parasitic components and diode reverse recovery on the operation of the snubber. Based on this
theory a snubber optimisation procedure is also developed. Possible operation strategies and
protection techniques were also evaluated for this topology. Single-phase experimental inverters
were used to verify the basic operation theory and switching loss prediction for both topologies.
The thesis is concluded by the design and construction of a practical soft-switching threephase
inverter. After implementation the experimental inverter is used for theory verification. / AFRIKAANSE OPSOMMING: Hierdie proefskrif beskryf die ondersoek na twee saggeskakelde omsetter topologieë wat veral
geskik is vir hoë-drywing toepassings. Die bestaande teorie aangaande die eerste topologie,
naamlik 'n aktiewe, resonante, afskakel gapser, word uitgebrei met 'n deeglike-studie oor bedryfstegnieke
en beskermingsmetodes.
Vervolgens word 'n gekombineerde gapser topologie, wat beide aanskakel- en afskakelverliese
verminder, ondersoek. Die studie behels 'n volledige analise van die verliese in die omsetter
en gapser komponente en die invloed van parasitêre komponente en diode tru-herstel. Hierdie
teorie word ook gebruik om 'n optimale gapser ontwerp prosedure te ontwikkel. Die moontlikke
bedryfstegnieke en beskermingsmetodes word ook vir hierdie topologie evalueer. In albei gevalle
is eksperimentele, enkelfase omsetters gebruik om die teorie oor basiese werking en skakelverlies
vermindering te verifieer.
Die ondersoek word afgesluit deur die ontwerp en konstruksie van 'n praktiese, saggeskakelde,
drie-fase omsetter te beskryf. Na implimentering van die omsetter word volledige eksperimentele
verifikasie uitgevoer.
|
259 |
Voltage control of medium to high power three-phase inverter supply systemsJacobs, D. M. (Danver Maxwill) 12 1900 (has links)
Thesis (MScEng)--University of Stellenbosch, 2001. / ENGLISH ABSTRACT: In this thesis a new voltage control method is developed for a three-phase inverter
supply system. The inverter supply system consist of a Permanent Magnet Generator, a
three-phase rectifier, a three-phase inverter plus LC-filter and a three-phase transformer
in series. This system supplies power to a network or to a stand-alone load. The main
focus of this thesis is on the control aspects of the inverter and the LC-filter.
Different voltage control systems are investigated and compared to each other. From
these methods the proposed voltage control method is developed where only the output
voltages are measured to establish good voltage control. All these voltage control
methods are also simulated with a software package. The proposed voltage control
method compares very well with other voltage control methods. The results that are
obtained in the simulations are satisfactory. The proposed voltage control method is also
implemented in an 8 kW laboratory scale model and, again, very good practical results
are obtained. A TMS320F240 nsp controller is used to implement the proposed voltage
control method. The controller compensates well for load steps, and these results
compare well to an alternative voltage control method, which was also evaluated
practically. / AFRIKAANSE OPSOMMING: In hierdie tesis IS 'n nuwe spanningsbeheermetode ontwikkel VIr 'n drie-fase
wisselrigter kragtoevoerstelsel. Die wisselrigter kragtoevoerstelsel bestaan uit 'n
Permanent Magneet Generator, 'n drie-fase gelykrigter, 'n drie-fase wisselrigter plus
Le-filter, en 'n drie-fase transformator in serie. Hierdie stelsel voorsien krag aan 'n
netwerk sowel as aan 'n alleenstaande las. Die hooffokus van hierdie tesis is op die
beheeraspekte van die wisselrigter en Le-filter.
Verskillende spanningsbeheermetodes is deeglik ondersoek en vergelyk met mekaar.
Uit hierdie metodes is dan die voorgestelde beheermetode ontwikkel waar slegs die
uittreespanning gemeet word om goeie spanningsbeheer te kan doen. Al hierdie
spanningsbeheermetodes is dan gesimuleer met 'n sagteware pakket. Die voorgestelde
spanningsbeheermetode vergelyk baie goed met die ander spanningsbeheermetodes. Die
resultate verky in die simulasies is ook baie bevredigend. Die voorgestelde
beheermetode is ook geïmplementeer op 'n 8 kW laboratorium skaalmodel en weereens
is baie goeie praktiese resultate verky. 'n TMS320F240 DSP-beheerder is gebruik om
die voorgestelde beheermetode mee te implementeer. Die beheerder kompenseer baie
goed vir lastrappe en vergelyk ook goed met 'n ander spanningsbeheermetode wat
prakties ge-evalueer is.
|
260 |
Analysis and design of a voltage regulator based on an AC-to-AC converterVan Schalkwyk, Christine 04 1900 (has links)
Thesis (MScEng)--University of Stellenbosch, 2003. / ENGLISH ABSTRACT: This thesis discusses the analysis and design of a voltage regulator based on
an AC-to-AC converter. A background study was performed on the best
topology for the purpose. The chosen topology was analysed and the
converter was designed in detail. A voltage sign-detector and an over-current
detector were designed and built. They were used for control and protection.
Three methods of control were investigated. The first was a slow but reliable
method of computing the RMS value of the input voltage and then using that
value and the RMS value of the desired output voltage to compute the duty
ratio of the converter. The second method was fast and is an open-loop
control method, where the measured input voltage and a reference value of
the desired output voltage are used to compute the duty ratio. The third
method is a closed-loop control method in which the input voltage, output
voltage and the same reference values used in the second method are used
to compute the duty ratio. All of these methods were implemented and tested. / AFRIKAANSE OPSOMMING: Hierdie tesis bespreek die analise en die ontwerp van 'n spannings
reguleerder wat gebaseer is op 'n WS-na-WS omsetter. 'n Ondersoek was
ingestelom die beste topologie te vind vir die doel. Die topologie wat gekies
is, is toe geanaliseer en die omsetter is in detailontwerp. 'n Spannings-tekendetektor
baan as ook 'n oorstroombeskermings baan was ontwerp en is
gebou. Hierdie bane word gebruik vir die beheer en die beveiliging van die
stelsel. Daar is drie metodes van beheer wat ondersoek is. Die eerste metode
is stadig, maar betroubaar. Die metode bereken die WGK waarde van die
intree spanning en gebruik dan die waarde en die WGK van die gewenste
uittree spanning om die diens siklus van die omsetter uit te werk. Die tweede
metode van beheer is vinnig en is 'n oop-lus metode van beheer. Hierdie
metode maak gebruik van die gemete intreespanning en 'n verwysing van die
gewensde uittree spanning om die dienssiklus uit te werk. Die derde metode
is 'n geslote-lus beheer wat van die gamete intreespanning, die gemete
uittreespanning en die verwysing soos die in die tweede beheermetode
gebruik maak on die diens siklus uit te werk. AI die metodes was
geimplementeer en getoets.
|
Page generated in 0.0523 seconds