• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 34
  • 34
  • 8
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

An improved commutator and some sources of error in the commutator method for the measurement of overvoltage The measurement of polarisation by the direct and commutator methods ...

Chên, Graham Mien, Ferguson, Alfred Lynn, January 1900 (has links)
Thesis (Ph. D.)--University of Michigan, 1930. / "By A.L. Ferguson and G.M. Chen." From the Journal of physical chemistry, v. 36, no. 4, April, 1932.
22

An arcover control for the spark gap

Beutler, Arthur Julius. January 1968 (has links)
Thesis (M.S.)--University of Wisconsin--Madison, 1968. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
23

An accurate, trimless, high PSRR, low-voltage, CMOS bandgap reference IC

Gupta, Vishal. January 2007 (has links)
Thesis (Ph. D.)--Electrical and Computer Engineering, Georgia Institute of Technology, 2008. / Ayazi, Farrokh, Committee Member ; Rincon-Mora, Gabriel, Committee Chair ; Bhatti, Pamela, Committee Member ; Leach, W. Marshall, Committee Member ; Morley, Thomas, Committee Member.
24

Applications of signal processing techniques in microprocessor based instrumentation

Duggirala, Madhukar. January 1984 (has links)
Call number: LD2668 .T4 1984 D84 / Master of Science
25

Quantitative clinical measurement of spasticity.

Chao, Alfred January 1976 (has links)
Thesis. 1976. M.S.--Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics. / Microfiche copy available in Archives and Barker. / Bibliography: p.80-81. / M.S.
26

A computer-aided measurement system for monopolar high-voltage direct-current coronating lines /

Tong, Sai-kit. January 1986 (has links)
Thesis--M. Phil., University of Hong Kong, 1986.
27

Sequential measurement of multidimensional transducers.

January 1964 (has links)
Bibliography: p. 85.
28

A computer-aided measurement system for monopolar high-voltage direct-current coronating lines

湯世傑, Tong, Sai-kit. January 1986 (has links)
published_or_final_version / Electrical Engineering / Master / Master of Philosophy
29

A wideband signal conditioning system for high voltage measurements using a transconductance topology

Agjee, F. M. D. E. (Faatima, Moosa, Dawood, Ebrahim) 03 1900 (has links)
Thesis (MScEng)--Stellenbosch University, 2000. / ENGLISH ABSTRACT: Recent research has shown that standard substation capacitive voltage transformers (CVTs) and current transformers (CTs) can be used for the measurement of wideband high voltage phenomena by employing these apparatus in a transconductance topology. With this topology the voltage waveform can be obtained by integration of the ground return current in the earth straps of the CVT and the CT. This technique does, however, impose unique requirements on the amplification and integration instrumentation due to large dynamic range requirements and the strict offset specifications required for accurate integration. This thesis describes a programmable, wideband signal conditioning system for high voltage (HV) measurements using the transconductance topology. A suitable system topology, optimised to reduce the problems usually associated with grounding and electromagnetic interference (EMI) in HV environments, is proposed. This system consists of an analog signal conditioning subsystem, a digital signal conditioning subsystem and a high speed serial fibre-optic link. The analog signal conditioning subsystem conditions the signals from a sensor to levels suitable for the digitiser of the digital signal conditioning subsystem. The high bandwidth specification of the application made it necessary to consider both discrete and integrated implementation of the analog signal conditioning subsystem. Based on the simulated and laboratory test results of both implementations, the optimum design was chosen for the developed system. The digital signal conditioning subsystem, which performs the integration, as well as the serial optic-fibre link control logic was implemented using programmable logic array (PLA) technology. The digital data is transmitted across the fibre-optic link. This data is then converted back to an analog signal. Keywords: High voltage measurements, Transconductance topology. / AFRIKAANSE OPSOMMING: Onlangse navorsing het aangetoon dat standaard substasie kapasitiewe spanningstransformators en stroomtransformators gebruik kan word om wyeband hoogspanningsverskynsels te meet deur hierdie apparatuur in 'n transkonduktansie topologie aan te wend. Met hierdie topologie kan die spanningsgolfvorm verkry word deur die integrasie van die aardstrome in die aardverbindings van die kapasitiewe spanningstransformators en stroomtransformators. Hierdie tegniek stel egter unieke vereistes vir die versterkings- en integrasieinstrumentasie te wyte aan groot dinamiese bereik vereistes en die streng afset spesifikasies wat benodig word vir akkurate integrasie. Hierdie tesis beskryf 'n programmeerbare, wyeband seinkondisioneringstelsel vir hoogspanningsmetings deur van die transkonduktansie topologie gebruik te maak. 'n Geskikte stelseltopologie, wat geoptimiseer is om probleme, wat gewoonlik met aarding en elektromagnetiese interferensie in hoogspanningsomgewings geassosieer word, te verminder, is voorgestel. Die stelsel bestaan uit 'n analoog seinkondisioneringsubstelsel, 'n digitale seinkondisioneringsubstelsel en 'n hoëspoed seriële optiese vesel koppelvlak. Die analoog seinkondisioneringsubstelsel kondisioneer die seine vanaf 'n sensor na geskikte vlakke vir die versyferaar van die digitale seinkondisioneringsubstelsel. Die hoë bandwydte spesifikasie van die toepassing vereis die inagneming van beide diskrete en geïntegreerde implementerings van die analoog seinkondisioneringsubstelsel. Gebaseer op gesimuleerde en laboratorium toetsresultate van beide implementerings is die optimale ontwerp vir die ontwikkelde stelsel gekies. Die digitale seinkondisioneringsubstelsel wat die integrasie uitvoer, asook die seriële optiese vesel koppelvlak beheerlogika is geïmplementeer met behulp van programmeerbare logika skikking tegnologie. Die digitale data word gestuur oor die optiese vesel koppelvlak. Hierdie data word dan terug geskakel na 'n analoog sein. Sleutelwoorde: Hoogspanningsmetings, Transkonduktansie topologie.
30

Real-time state estimation of a distributed electrical power system under conditions of deregulation

Kusekwa, Mashauri A. D. January 2010 (has links)
Thesis (DTech (Electrical Engineering))--Cape Peninsula University of Technology, 2010. / Static state estimation is a mathematical procedure in which physical measurements from sub-stations and physical model are combined in an optimal way. That is, the measurements obtained from the sub-stations are used with the physical model and the states of the power system are selected or calculated such that the states match the measurements in some best way. The states of a power system are the bus voltage magnitude and voltage angle of each bus of the system. Static state estimation is an increasingly common part of electrical power utility energy management systems (EMS). It plays a critical part in a day-to-day operation of a power system utility. The system measurements obtained from static estimation are used for realtime operations like optimal power flow calculations and contingency analysis. Proper system operations with regards to avoidance of insecure conditions includes situational awareness, therefore, the static estimator plays an important role in power system security. A further motivation: in increasingly electrical power deregulation, more economic operations mean savings for customers and electrical power provider alike. Economic benefit might be realized if system operators have a more accurate situational awareness of the system through improved power system state estimator. The objective of the study was to develop method, algorithm and MATLAB program for solution of power system state estimation using parallel processing techniques. In achieving the objective, the study has concentrated on development of an approximate Tanzanian power system network model comprising of 30 buses and used as a case study; decomposing the bus admittance matrix of the model into 3 interconnected sub-systems; development of mathematical model for real and reactive power injections, real and reactive power flows in the transmission lines and tie-lines connecting the sub-systems; development of measurement data model for voltage magnitude, real and reactive power injections, real and reactive power flows; formulating of a constrained weighted least absolute value state estimation problem; development of decomposition-coordination method and algorithm; and formulating algorithm and MATLAB program for solving the constrained state estimation problem using parallel processing technique.

Page generated in 0.1082 seconds