• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1458
  • 474
  • 302
  • 188
  • 149
  • 112
  • 88
  • 55
  • 35
  • 28
  • 24
  • 15
  • 13
  • 13
  • 13
  • Tagged with
  • 3571
  • 626
  • 430
  • 379
  • 365
  • 354
  • 306
  • 263
  • 218
  • 203
  • 202
  • 198
  • 194
  • 191
  • 189
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

CHANGE IN THE THERMIONIC EMISSION CURRENT OF PALLADIUM DUE TO CHEMISORPTION OF ATOMIC AND MOLECULAR HYDROGEN

Eisenstadt, Melvin Mortimer, 1931- January 1966 (has links)
No description available.
72

Respiratory motion correction for positron emission tomography

Dikaios, Nikolaos January 2012 (has links)
No description available.
73

Exo-electron emission during heterogeneous catalysis

Tamjidi, Freedoon, 1948- January 1972 (has links)
No description available.
74

Characterization of silicon photomultiplier readout designs for use in positron emission tomography systems

Liu, Chen-Yi 29 October 2011 (has links)
Geiger-mode avalanche photodiodes, or silicon photomultipliers, are promising light sensors for the next generation Positron Emission Tomography (PET) scanners. The sensor is being used in the scanner’s gamma ray detector to measure scintillation light. This thesis describes the test results of three gamma ray detectors that utilize silicon photomultipliers. The first one is a commercial detector, and the other two are custom made. The detectors are tested for their 511 keV photon energy and timing resolution, as well as their ability to measure light from small scintillator crystals. The two custom made detectors had smaller active area, but outperformed the commercial detector in energy resolution. The introduction of buffer amplifiers improved the timing resolution of one detector. All three detectors had their crystal decoding ability limited by signal multiplexing and the sensor’s dark noise. Finally, a detector design was proposed for the PET system being developed in our group.
75

Ordering and disordering of hydroxylic solvents by ions and biopolymer surfaces employing emission spectroscopy

Milton, John G. January 1974 (has links)
No description available.
76

Development of a model for characterizing pneumatically generated primary aerosols for inductively coupled plasma emission spectrometry

Msimanga, Ntombiyomusa Doris Grissel 05 1900 (has links)
No description available.
77

Combining positron emission tomography (PET) data with neuroanatomical constraints : comparing models of single-word processing

Nikelski, Erwin James. January 1996 (has links)
The focus of this paper is to apply some of the new analytic techniques to positron emission tomography (PET) data in order to test the neuroanatomical plausibility of two very specific models of language processing: the model of Geschwind (1965), and that of Petersen et al. (1988; 1989). Model plausibility was assessed by fitting both models to a word repetition and a synonym generation rCBF PET dataset using methods based on the examination of interregional correlations, and structural equation modeling. / Physiologically-based regions of interest were defined a priori through a review of PET activation literature. The current study demonstrated (1) the feasibility of using a priori defined physiological regions of interest in model evaluation, (2) the advantages of using structural equation modeling over interregional correlations, and (3) that neither model proved to be a particularly good fit to the data.
78

Characterization of silicon photomultiplier readout designs for use in positron emission tomography systems

Liu, Chen-Yi 29 October 2011 (has links)
Geiger-mode avalanche photodiodes, or silicon photomultipliers, are promising light sensors for the next generation Positron Emission Tomography (PET) scanners. The sensor is being used in the scanner’s gamma ray detector to measure scintillation light. This thesis describes the test results of three gamma ray detectors that utilize silicon photomultipliers. The first one is a commercial detector, and the other two are custom made. The detectors are tested for their 511 keV photon energy and timing resolution, as well as their ability to measure light from small scintillator crystals. The two custom made detectors had smaller active area, but outperformed the commercial detector in energy resolution. The introduction of buffer amplifiers improved the timing resolution of one detector. All three detectors had their crystal decoding ability limited by signal multiplexing and the sensor’s dark noise. Finally, a detector design was proposed for the PET system being developed in our group.
79

Emission and dispersion of odour from swine operations

Zhou, Xiaojing 19 January 2011 (has links)
Odour emissions and instantaneous downwind odour plumes were measured on two 3000-sow swine farrowing farms located in a flat area of southern Manitoba, one farm (Farm A) with open earthen manure storage (EMS) and another (Farm B) with negative air pressure (NAP) covered EMS. Three commonly used dispersion models (ISCST3, AUSPLUME, and INPUFF-2) were used to predict downwind odour distributions on the two farms. Dispersion predictions were based on the measured odour emission data for each farm and on-site weather data recorded by a portable weather station. The peak-to-mean ratios of downwind odour intensity were computed from field odour intensity measurements and analysed against averaging time, downwind distance, and atmosphere stability class. It was found that the average odour emission rate from the negative pressure covered earthen manure storage (NAP EMS) was negligible in comparison with the open EMS (0.3 vs 20.3 OU/ s-m2). Downwind odour intensity measured by trained human sniffers on Farm A with covered manure storage was significantly (P<0.05) lower than that on Farm B with open manure storage at 100 and 500 m, but the difference in odour intensity at 1000 m was not significant (P>0.05) between the two farms. A 46% difference in odour emission rate between Farms A and B resulted in a 14% difference in the separation distance for odour annoyance-free between the two farms. When three commonly used dispersion models, namely AUSPLUME, ISCST3, and INPUFF-2, were used to predict downwind odour from the farms, the percentage of agreement between model predictions and field measurements was adequate for downwind distances of 500 and 1000 m, but relatively low for 100 m for all three models. Since the long-distance (>1000 m) predictions are of more practical value, all three models were considered to be adequate in predicting odour downwind from the swine operations. The peak-to-mean ratios of downwind odour intensity were computed from field odour intensity measurements and analysed against averaging time, downwind distance, and atmospheric stability class. The peak-to-mean ratio of field odour intensity increases with averaging time and downwind distance, and unstable atmospheric conditions.
80

The effect of diode and array geometrical parameters on performance of high field electron emitters formed from unidirectionally solidified uranium dioxide-tungsten composites

Ohlinger, Wayne Laurance 08 1900 (has links)
No description available.

Page generated in 0.0515 seconds