• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 13
  • 8
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Automação de diagnóstico para ensaios nao destrutivos magnéticos. / Automation of diagnostic for non-destrutive magnetic tests.

Ana Isabel Castillo Pereda 05 August 2010 (has links)
Este trabalho apresenta um método para o reconhecimento e a detecção automática dos diferentes valores ou graus de deformação plástica em Ensaios Não Destrutivos empregando o Ruído Magnético de Barkhausen. O método é baseado no uso de uma Rede Neural Probabilística que permite o diagnóstico automático dos diferentes valores de deformação plástica, conteúdo de carbono, estas medidas são procedentes das medições das amostras de placas de aço AISI 1006, 1050 e 1070, esta base de dados foi feita pelo grupo de pesquisadores do Laboratório de Dinâmica e Instrumentação LADIN da Escola Politécnica da USP, departamento da Mecânica. Os excelentes resultados da rede neural probabilística de detectar automaticamente os valores de deformação mostram a efetividade do desempenho da rede neural probabilística que tem um desempenho superior aos métodos não destrutivos tradicionais e que realmente esta nova tecnologia é uma excelente solução para o diagnóstico. / This work presents a method for automatic detection and recognition of different levels or degrees of plastic deformation in Non-Destructive Testing using the Magnetic Barkhausen Noise. The method is based on using a Probabilistic Neural Network that allows the automatic diagnosis of the different values of plastic deformation and carbon content. The measurements corresponds to samples of steel plates AISI 1006, 1050 and 1070, this database was made by the group of researchers from the Laboratory of Dynamics and Instrumentation LADIN the Polytechnic School of USP, Department of Mechanical Engineering. The results show the effectiveness of the probabilistic neural network to automatically detect plastic deformation levels as well as carbon content level. This method has a superior performance in comparison to traditional nondestructive methods.
12

Radiografia com elétrons induzida por nêutrons / NEUTRON INDUCED ELETRON RADIGRAPHY

Andrade, Marcos Leandro Garcia 25 February 2008 (has links)
No presente trabalho foi desenvolvida uma nova técnica radiográfica que utiliza feixes de elétrons de baixa energia como radiação penetrante para inspecionar amostras finas com espessuras da ordem de micra. Esta técnica é denominada, radiografia com elétrons induzida por nêutrons e os feixes são obtidos mediante a irradiação de uma tela de gadolínio com nêutrons térmicos. Foram determinadas as condições ótimas para a obtenção de radiografias no filme convencional para raios - X, Kodak Industrex AA, utilizando um sistema digital para análise do grau de enegrecimento dos filmes. Todas as irradiações foram realizadas em um equipamento radiográfico instalado no canal de irradiação 08 do reator nuclear de pesquisas IEA-R1 do IPEN-CNEN/SP. O tempo de irradiação necessário para se obter a radiografia com o melhor contraste foi de 100 segundos e nesta condição foi possível discernir 1 ?m em 24 ?m de alumínio com uma resolução máxima de 32 ?m. As imagens radiográficas obtidas no IPENCNEN/ SP por esta técnica apresentam visualmente uma qualidade superior quando comparadas as obtidas pelas outras técnicas radiográficas usuais que utilizam elétrons como radiação penetrante e filmes para o registro da imagem. Além disto, o sistema digital propiciou uma maior praticidade referente à aquisição e a análise dos dados e uma melhor visualização das imagens radiográficas. / In the present paper a new radiography technique, the \"Neutron Induced Electron Radiography - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole #8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 ?m in 24 ?m of aluminum at a resolution of 32 ?m. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization.
13

Radiografia com elétrons induzida por nêutrons / NEUTRON INDUCED ELETRON RADIGRAPHY

Marcos Leandro Garcia Andrade 25 February 2008 (has links)
No presente trabalho foi desenvolvida uma nova técnica radiográfica que utiliza feixes de elétrons de baixa energia como radiação penetrante para inspecionar amostras finas com espessuras da ordem de micra. Esta técnica é denominada, radiografia com elétrons induzida por nêutrons e os feixes são obtidos mediante a irradiação de uma tela de gadolínio com nêutrons térmicos. Foram determinadas as condições ótimas para a obtenção de radiografias no filme convencional para raios - X, Kodak Industrex AA, utilizando um sistema digital para análise do grau de enegrecimento dos filmes. Todas as irradiações foram realizadas em um equipamento radiográfico instalado no canal de irradiação 08 do reator nuclear de pesquisas IEA-R1 do IPEN-CNEN/SP. O tempo de irradiação necessário para se obter a radiografia com o melhor contraste foi de 100 segundos e nesta condição foi possível discernir 1 ?m em 24 ?m de alumínio com uma resolução máxima de 32 ?m. As imagens radiográficas obtidas no IPENCNEN/ SP por esta técnica apresentam visualmente uma qualidade superior quando comparadas as obtidas pelas outras técnicas radiográficas usuais que utilizam elétrons como radiação penetrante e filmes para o registro da imagem. Além disto, o sistema digital propiciou uma maior praticidade referente à aquisição e a análise dos dados e uma melhor visualização das imagens radiográficas. / In the present paper a new radiography technique, the \"Neutron Induced Electron Radiography - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole #8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 ?m in 24 ?m of aluminum at a resolution of 32 ?m. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization.

Page generated in 0.0877 seconds