• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 2
  • Tagged with
  • 7
  • 7
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Izolace nukleových kyselin pro diagnostické účely s využitím polymerních nosičů / Nucleic acids isolation for diagnostic purposes using polymeric carriers

Syslová, Ivona January 2009 (has links)
The isolation of deoxyribonucleic acid (DNA) was studied in the diploma thesis by using three different methods: phenol extraction, salting with sodium chloride and magnetic separation with reversible adsorption of nucleic acids on different magnetic carriers. There were used five different properly functionalized carriers for the isolation of DNA: magnetic silicagel, P(HEMA-co-GMA) ox. I, P(HEMA-co-GMA) ox. II, Dynal DNA Direct and Perovskit 439. The reversible imobilization of DNA on the magnetic carrier was proceeded under the conditions of high concentration of NaCl and poly(ethyleneglycol) (PEG). There was induced the condensation of DNA by 2 M NaCl and PEG with molecular mass 6000 for binding of the DNA to the magnetic carriers and the final concentration of PEG in the separation mixture was 8 and 16 %. The aim was to gain the DNA of quality suitable for polymerase chain reaction (PCR). The DNA was isolated from the bacterial cultures of three probiotic strains, L. amylovorus CCM 4380T, L. zeae CCM 7069 T, L. plantarum CCM 7039T, which were cultivated in MRS medium. The DNA was also isolated from the fermented dairy products: Jihočeský zákys s ovocem jahoda (the fermented dairy product with the probiotic culture of Lactobacillus acidophilus, Bifidobacterium lactis and Streptococcus thermophilus), Revital active (the yogurt with inulin and the probiotic culture of Lactobacillus rhamnosus, Lactobacillus acidophilus and Bifidobacterium sp.) and Actimel višeň (the dairy product with the probiotic culture of Lactobacillus casei). When the PCR with the isolated DNA was passed off, the PCR products were detected by the gel electrophoresis with agarose. The success of the DNA isolation of the probiotic bacteria by phenol extraction, salting with NaCl and by magnetic separation, was verified by the PCR method. The method of magnetic separation using magnetic carriers was also verified for the isolation of DNA of quality suitable for PCR from the probiotic fermented dairy products.
2

Implantable microelectrode biosensors for neurochemical monitoring of brain functioning / Microcapteurs implantables pour le suivi neurochimique de fonctionnement du cerveau

Vasylieva, Natalia 11 September 2012 (has links)
Les microcapteurs implantables sont des outils de choix pour l’étude du système nerveux central. Ils permettent d’analyser en temps réel la composition du milieu interstitiel du cerveau et les variations de concentration de neurotransmetteurs et de substrats métaboliques dans l’espace extracellulaire. La procédure d’immobilisation de l’enzyme sur l’électrode est une étape cruciale déterminant les performances du biocapteur. Nous avons développé une méthode d’immobilisation simple, non-toxique et peu chère en utilisant une molécule de poly(ethyleneglycol) diglycidyl éther (PEGDE) qui répond bien aux critères des applications cliniques. La méthode a été étudiée et optimisée sur trois enzyme: la Glucose oxydase, la D-amino acide oxydase et la Glutamate oxydase. Les capteurs développés se caractérisent par une forte sensibilité et un temps de réponse suffisamment court pour la détection des événements biologiques en temps réel. Les capteurs à base de PEGDE ont démontrés une bonne stabilité dans le temps et leur capacité de suivre en temps réel la variation de concentration de glucose dans le SNC du rat suite à l’injection d’insuline ou de glucose. Nous avons également adapté les méthodes d’immobilisation d’enzyme les plus utilisées dans le domaine des neurosciences: immobilisation par réticulation dans des vapeurs de Glutaraldéhyde ou par PEGDE, piégeage dans une matrice de sol-gel ou de polypyrrole dérivé, ou immobilisation dans une matrice d’hydrogel. Nous avons comparé les biocapteurs ainsi obtenus en termes de sensibilité, de stabilité in vivo, de temps de réponse et aussi de toxicité. Cette étude comparative nous a permis de conclure que le PEGDE représente un procédé d’immobilisation optimal car il ne demande pas de synthèse organique, contrairement à l’hydrogel, il n’est pas toxique contrairement au glutaraldehyde et il assure une immobilisation covalente plus stable que le piégeage dans des sol-gel ou polypyrrole. Cette étude comparative a mis également en évidence l’effet de la procédure de fixation de l’enzyme sur la spécificité du biocapteur. Nous avons montré que l’immobilisation par glutaraldehyde provoque une importante perte de sélectivité de l’enzyme. Quant au PEGDE, son immobilisation est assez douce pour préserver la spécificité naturelle de l’enzyme. Nous avons montré que la procédure d’immobilisation a un impact important sur la quantification des molécules dans les échantillons biologiques et in vivo. La validité des mesures sur nos capteurs a été contrôlée par HPLC ou électrophorèse capillaire. Nous avons également développé des sondes multisensibles en utilisant les techniques de microfabrication sur silicium. Le dispositif comporte une aiguille de 6mm en longueur, 100µm en largeur et 50 µm en épaisseur. Elle porte trois électrodes de taille 40x200µm. Ces dispositifs, optimisés pour réduire les effets d’interférence entre les électrodes, ont été pour le suivi simultané de glucose et lactate dans le SNC de rats anesthésiés. / Identification, monitoring and quantification of biomolecules in the CNS is a field of growing interest for identifying biomarkers of neurological diseases. In this thesis, silicon needle-shaped multi-molecules sensing microprobes were developed. Our microelectrode array design comprises a needle length of 6mm with 100x50 µm2 cross-section bearing three platinum electrodes with a size of 40x200 µm and 200µm spacing between them. We have used these microprobes for simultaneous glucose and lactate monitoring, using the third electrode for control of non-specific current variations. Local microdroplet protein deposition on the electrode surface was achieved using a pneumatic picopump injection system. Enzyme immobilization on the electrode surface is a key step in microelectrode biosensor fabrication. We have developed a simple, low cost, non-toxic enzyme immobilization method employing poly(ethyleneglycol) diglycidyl ether (PEGDE). Successful biosensor fabrication was demonstrated with glucose oxidase, D-amino acid oxidase, and glutamate oxidase. We found that these biosensors exhibited high sensitivity and short response time sufficient for observing biological events in vivo on a second-by-second timescale. PEGDE-based biosensors demonstrated an excellent long-term stability and reliably monitored changes in brain glucose levels induced by sequential administration of insulin and glucose solution. We then carried out a comparative study of five enzyme immobilization procedures commonly used in Neuroscience: covalent immobilization by cross-linking using glutaraldehyde, PEGDE, or a hydrogel matrix and enzyme entrapment in a sol-gel or polypyrrole-derived matrices. Enzymatic microelectrodes prepared using these different procedures were compared in terms of sensitivity, response time, linear range, apparent Michaelis-Menten constant, stability and selectivity. We conclude that PEGDE and sol-gel techniques are potentially promising procedures for in vivo laboratory studies. The comparative study also revealed that glutaraldehyde significantly decreased enzyme selectivity while PEGDE preserved it. The effects that immobilization can have on enzyme substrate specificity, produce dramatic consequences on glutamate detection in complex biological samples and in the CNS. Our biosensor’s results were systematically controlled by HPLC or capillary electrophoresis. The highly selective PEGDE-based biosensors allowed accurate measurements glutamate concentrations in the anesthetized and awaked rats at physiological conditions and under pharmacological and electrical stimulations. The microfabricated multielectrodes based on silicon needles coupled to the simple, non-toxic and mild immobilization method based on PEGDE, open new possibilities for specific neurotransmitter detection in the central nervous system and the study of cell-cell communication in vivo.
3

Atmospheric Pressure Plasma Synthesis of Biocompatible Poly(ethylene glycol)-like Coatings

Nisol, Bernard 26 May 2011 (has links)
The role of a protein-repelling coating is to limit the interaction between a device and its physiological environment. Plasma-polymerized-PEG (pp-PEG) surfaces are of great interest since they are known to avoid protein adsorption. and cell attachment. However, in all the studies previously published in the literature, the PEG coatings have been prepared using low pressure processes. In this thesis, we synthesize biocompatible pp-PEG coatings using atmospheric pressure plasma. Two original methods are developed to obtain these pp-PEG films. 1. Atmospheric pressure plasma liquid deposition (APPLD) consists in the injection of the precursor, tetra(ethylene glycol)dimethylether (tetraglyme), by means of a liquid spray, directly in the post-discharge of an atmospheric argon plasma torch. 2. In atmospheric pressure plasma-enhanced chemical vapor deposition (APPECVD), tetraglyme vapors are brought in the post-discharge trough a heating sprinkler. The chemical composition, as well as the non-fouling properties of the APPLD and APPECVD films, are compared to those of PEG coatings synthesized by conventional low pressure plasma processes. In the first part of the study, the effect of the power on the chemical composition of the films has been investigated by infrared reflection absorption spectroscopy (IRRAS), X-ray photoelectron spectroscopy (XPS) and secondary ions mass spectroscopy (SIMS). The surface analysis reveals that for the APPECVD samples, the fragmentation of the precursor increases as the power of the treatment is increased. In other terms, the lower the plasma power is, the higher the “PEG character” of the resulting films is. Indeed, the C-O component (286.5 eV) of the XPS C 1s peak is decreasing while the hydrocarbon component (285 eV) is increasing as the power of the plasma is increased. The same conclusion can be drawn from the signature ToF-SIMS peaks (m/z = 45 (CH3OCH2+ and +CH2CH2OH), 59 (CH3OCH2CH2+), 103 (CH3(OCH2CH2)2+)) that are decreasing in the case of high power treatments. Accordingly, IRRAS measurements show that the C-O stretching band is decreasing for high power plasma deposition. This is in agreement with the observations made from the analysis of the LP PECVD coatings and from the literature. The films deposited by the APPLD process do not show the same behavior. Indeed, whatever the power injected into the discharge is, we are able to achieve films with a relatively high PEG character (83 %). The second part of this study is dedicated to the evaluation of the non-fouling properties of the coatings by exposing them to proteins (bovine serum albumin and human fibrinogen) and cells (mouse fibroblasts (L929 and MEF)) and controlling the adsorption with XPS (proteins) and SEM (cells). For the APPECVD samples, a low plasma power (30 W) leads to an important reduction of protein adsorption and cell adhesion (over 85%). However, higher-powered treatments tend to reduce the non-fouling ability of the surfaces (around 50% of reduction for a 80 W deposition). The same order of magnitude (over 90% reduction of the adsorption) is obtained for the APPLD surfaces, whatever is the power of the treatment. Those results show an important difference between the two processes in terms of power of the plasma treatment, and a strong relationship between the surface chemistry and the adsorption behavior: the more the PEG character is preserved, the more protein-repellent and cell-repellent is the surface. / Le rôle d’une couche empêchant l’adsorption de protéines est de limiter les interactions entre un implant et le milieu physiologique auquel il est exposé. Les films de poly(éthylène glycol) polymérisés par plasma (pp-PEG) sont d’intérêt majeur car ils sont connus pour empêcher l’adsorption de protéines ainsi que l’attachement cellulaire. Cependant, dans toutes les études publiées précédemment, les couches de type PEG ont été réalisées sous vide. Dans cette thèse de doctorat, nous synthétisons des couches de type pp-PEG biocompatibles par plasmas à pression atmosphérique. A cette fin, deux méthodes originales ont été développées. 1. La première méthode consiste en l’injection du précurseur, le tetra(éthylène glycol) diméthyl éther (tetraglyme), en phase liquide, en nébulisant ce dernier au moyen d’un spray, directement dans la post-décharge d’une torche à plasma atmosphérique fonctionnant à l’argon. En anglais, nous appelons ce procédé « Atmospheric pressure plasma liquid deposition (APPLD) ». 2. Dans la deuxième méthode, appelée en anglais « Atmospheric pressure plasma-enhanced chemical vapor deposition (APPECVD)», le tetraglyme est amené en phase vapeur dans la post-décharge, au moyen d’un diffuseur chauffant. La composition chimique des dépôts de type APPLD et APPECVD, ainsi que leurs propriétés d’anti-adsorption sont évaluées, et comparées aux dépôts pp-PEG obtenus par les méthodes à basse pression conventionnelles. Dans la première partie de cette étude, nous nous focalisons sur la composition chimique des films déposés, et plus particulièrement sur l’influence de la puissance injectée dans le plasma sur cette composition chimique. A cette fin, nous avons fait appel à des techniques d’analyse telles que la spectroscopie de réflexion-absorption infrarouge (IRRAS), la spectroscopie des photoélectrons X (XPS) et la spectrométrie de masse des ions secondaires (SIMS). Il en ressort que les films de type APPECVD perdent progressivement leur « caractère PEG » à mesure que la puissance de la décharge plasma est élevée. Cela serait dû à une plus grande fragmentation du précurseur dans la post-décharge d’un plasma plus énergétique. Cette tendance est cohérente avec ce que nous avons observé pour les dépôts à basse pression ainsi que dans la littérature. Dans le cas des films de type APPLD, un tel comportement n’a pas été mis en évidence : quelle que soit la puissance dissipée dans le plasma, les films présentent un « caractère PEG » relativement élevé. La deuxième partie de cette thèse est dédiée à l’évaluation des propriétés d’anti-adsorption des films synthétisés, en les exposant à des protéines (albumine de sérum bovin et fibrinogène humain) et des cellules (fibroblastes de souris, L929 et MEF). L’adsorption de protéines est contrôlée par XPS tandis que l’attachement cellulaire est contrôlé par imagerie SEM. Pour les échantillons de type APPECVD, un dépôt à faible puissance (30 W) mène à une importante réduction de l’adsorption de protéines et de cellules (> 85%) tandis qu’à de plus hautes puissances (80 W), l’anti-adsorption est sensiblement diminuée (50% de réduction). Dans le cas des dépôts de type APPLD, quelle que soit la puissance du plasma, une forte diminution de l’adsorption de protéines et de cellules est observée (> 90 %). Ces résultats montrent une différence majeure entre les deux procédés quant à l’influence de la puissance du plasma ainsi qu’une forte relation entre la composition chimique de la surface synthétisée et son pouvoir d’anti-adsorption : plus le « caractère PEG » du dépôt est conservé, plus la surface empêchera l’interaction avec les protéines et les cellules.
4

Towards greener stationary phases : thermoresponsive and carbonaceous chromatographic supports

Tan, Irene January 2011 (has links)
Polymers which are sensitive towards external physical, chemical and electrical stimuli are termed as ‘intelligent materials’ and are widely used in medical and engineering applications. Presently, polymers which can undergo a physical change when heat is applied at a certain temperature (cloud point) in water are well-studied for this property in areas of separation chemistry, gene and drug delivery and as surface modifiers. One example of such a polymer is the poly (N-isopropylacrylamide) PNIPAAM, where it is dissolved well in water below 32 oC, while by increasing the temperature further leads to its precipitation. In this work, an alternative polymer poly (2-(2-methoxy ethoxy)ethyl methacrylate-co- oligo(ethylene glycol) methacrylate) (P(MEO2MA-co-OEGMA)) is studied due to its biocompatibility and the ability to vary its cloud points in water. When a layer of temperature responsive polymer was attached to a single continuous porous piece of silica-based material known as a monolith, the thermoresponsive characteristic was transferred to the column surfaces. The hybrid material was demonstrated to act as a simple temperature ‘switch’ in the separation of a mixture of five steroids under water. Different analytes were observed to be separated under varying column temperatures. Furthermore, more complex biochemical compounds such as proteins were also tested for separation. The importance of this work is attributed to separation processes utilizing environmentally friendly conditions, since harsh chemical environments conventionally used to resolve biocompounds could cause their biological activities to be rendered inactive. / Polymere, welche empfindlich gegenüber externen physikalischen, chemischen und elektrischen Einflüssen sind, werden „intelligente Materialien“ genannt. Diese werden weitverbreitet in medizinischen und technischen Anwendungen eingesetzt. Auf diesem Gebiet ausführlich erforschte Materialien sind Polymere, welche durch Hitze bei einer bestimmten Temperatur (Trübungspunkt) eine physikalische Veränderung eingehen können, genannt thermoresponsive Polymere. Eingesetzt werden diese z.B. in chromatographischen Trennverfahren, in Gen- und Wirkstofftransport Vorgängen und zur Oberflächenmodifikation. Ein Beispiel für so ein Polymer ist das poly(N-isopropylacrylamide) PNIPAAM, welches unter 32 °C in Wasser gelöst vorliegt und mit Erhöhung der Temperatur als Niederschlag ausfällt. In dieser Arbeit wurde ein alternatives Polymer, das poly(2-(2-methoxyethoxy)ethylmethacrylate-co-oligo(ethyleneglycol) methacrylate) (P(MEO2MA-co-OEGMA)), untersucht, in Bezug auf Biokompatibilität und der Änderung des Trübungspunktes in Wasser. Wenn eine Schicht eines temperaturempfindlichen Polymers auf einen Monolithen (einteiliger, poröser und auf Silika-basierendes Material) aufgebracht wird, werden die thermoresponsiven Eigenschaften auf die Oberfläche dieses Monolithen übertragen. Der Monolith dient hier als Säule in einer HPLC-Anlage. Es wurde gezeigt, dass das Hybrid-Material als einfacher „Temperaturschalter“ in der Trennung von fünf verschiedenen Steroiden in Wasser agieren kann. Untersucht wurde die Separation verschiedener Analyten mit dem Variieren der Säulentemperatur. Zusätzlich wurden mehr komplexe biochemische Stoffe, wie Proteine, getestet. Die Bedeutung dieser Arbeit ist zurückzuführen auf Separationsprozesse, welche umweltfreundlichen Bedingungen nutzen, da die rauen chemischen Bedingungen in konventionellen Separationsprozessen die biologische Inaktivität der Verbindungen zur Folge haben können. Der zweite Teil der Arbeit beschäftigte sich mit der Entwicklung eines alternativen Trägermaterials als Ersatz zu den Silika-basierende Trennungssäulen. Kohlenstoffmaterialien sind aufgrund ihrer ausgezeichneten mechanischen Härte und chemischen Stabilität eine vielversprechend Alternative. Die Synthese von Kohlenstoffkugeln als Trägermaterial kann als „grüner“ Prozess in meiner Arbeit angesehen werden, da milde Synthesebedingungen in purem Wasser verwendet wurden. Die Leistungsfähigkeit des Materials wurde mit einer Serie von Separationsreaktionen gezeigt.
5

Implantable microelectrode biosensors for neurochemical monitoring of brain functioning

Vasylieva, Natalia 11 September 2012 (has links) (PDF)
Identification, monitoring and quantification of biomolecules in the CNS is a field of growing interest for identifying biomarkers of neurological diseases. In this thesis, silicon needle-shaped multi-molecules sensing microprobes were developed. Our microelectrode array design comprises a needle length of 6mm with 100x50 µm2 cross-section bearing three platinum electrodes with a size of 40x200 µm and 200µm spacing between them. We have used these microprobes for simultaneous glucose and lactate monitoring, using the third electrode for control of non-specific current variations. Local microdroplet protein deposition on the electrode surface was achieved using a pneumatic picopump injection system. Enzyme immobilization on the electrode surface is a key step in microelectrode biosensor fabrication. We have developed a simple, low cost, non-toxic enzyme immobilization method employing poly(ethyleneglycol) diglycidyl ether (PEGDE). Successful biosensor fabrication was demonstrated with glucose oxidase, D-amino acid oxidase, and glutamate oxidase. We found that these biosensors exhibited high sensitivity and short response time sufficient for observing biological events in vivo on a second-by-second timescale. PEGDE-based biosensors demonstrated an excellent long-term stability and reliably monitored changes in brain glucose levels induced by sequential administration of insulin and glucose solution. We then carried out a comparative study of five enzyme immobilization procedures commonly used in Neuroscience: covalent immobilization by cross-linking using glutaraldehyde, PEGDE, or a hydrogel matrix and enzyme entrapment in a sol-gel or polypyrrole-derived matrices. Enzymatic microelectrodes prepared using these different procedures were compared in terms of sensitivity, response time, linear range, apparent Michaelis-Menten constant, stability and selectivity. We conclude that PEGDE and sol-gel techniques are potentially promising procedures for in vivo laboratory studies. The comparative study also revealed that glutaraldehyde significantly decreased enzyme selectivity while PEGDE preserved it. The effects that immobilization can have on enzyme substrate specificity, produce dramatic consequences on glutamate detection in complex biological samples and in the CNS. Our biosensor's results were systematically controlled by HPLC or capillary electrophoresis. The highly selective PEGDE-based biosensors allowed accurate measurements glutamate concentrations in the anesthetized and awaked rats at physiological conditions and under pharmacological and electrical stimulations. The microfabricated multielectrodes based on silicon needles coupled to the simple, non-toxic and mild immobilization method based on PEGDE, open new possibilities for specific neurotransmitter detection in the central nervous system and the study of cell-cell communication in vivo.
6

Izolace DNA s použitím nově syntetizovaných magnetických nosičů / DNA isolation using newly designed magnetic carriers

Machan, Radoslav January 2018 (has links)
Theoretical part of the master thesis was aimed on giving an overview of basic characteristics of magnetic particles, their morphology, basic methods of their synthesis, interaction with DNA and recent applications in biotechnology and biomedicine. The experimental part of thesis was aimed on application of new designed magnetic particles for isolation of both lactobacilli DNA and calf thymus DNA. Two types of magnetic beads were used: hyperbranched poly(glycidyl methacrylate-co-[2-(methacryloyloxy) ethoxy]acetic acid-co-ethylene dimethylacrylate) microbeads covered with amino groups (P(GMA-MOEAA-EDMA)-NH2) and magnetic non-porous poly(2-hydroxyethyl methacrylate) microbeads covered with carboxyl groups (P(HEMA-co-GMA)-COOH). For both types of microbeads two different protocols for preparation of separation mixtures with two different concentrations od poly(ethyleneglycol) 6000 (PEG 6000) as condensation agent were tested. Differences among both types of magnetic microbeads and DNAs used were found. It was shown that both types of microbeads are suitable for DNA isolation in the presence of 8% PEG 6000.
7

Atmospheric pressure plasma synthesis of biocompatible poly(ethylene glycol)-like coatings

Nisol, Bernard 26 May 2011 (has links)
The role of a protein-repelling coating is to limit the interaction between a device and its physiological environment. Plasma-polymerized-PEG (pp-PEG) surfaces are of great interest since they are known to avoid protein adsorption. and cell attachment. However, in all the studies previously published in the literature, the PEG coatings have been prepared using low pressure processes. <p>In this thesis, we synthesize biocompatible pp-PEG coatings using atmospheric pressure plasma. Two original methods are developed to obtain these pp-PEG films. 1. Atmospheric pressure plasma liquid deposition (APPLD) consists in the injection of the precursor, tetra(ethylene glycol)dimethylether (tetraglyme), by means of a liquid spray, directly in the post-discharge of an atmospheric argon plasma torch. 2. In atmospheric pressure plasma-enhanced chemical vapor deposition (APPECVD), tetraglyme vapors are brought in the post-discharge trough a heating sprinkler. The chemical composition, as well as the non-fouling properties of the APPLD and APPECVD films, are compared to those of PEG coatings synthesized by conventional low pressure plasma processes.<p>In the first part of the study, the effect of the power on the chemical composition of the films has been investigated by infrared reflection absorption spectroscopy (IRRAS), X-ray photoelectron spectroscopy (XPS) and secondary ions mass spectroscopy (SIMS). <p>The surface analysis reveals that for the APPECVD samples, the fragmentation of the precursor increases as the power of the treatment is increased. In other terms, the lower the plasma power is, the higher the “PEG character” of the resulting films is. Indeed, the C-O component (286.5 eV) of the XPS C 1s peak is decreasing while the hydrocarbon component (285 eV) is increasing as the power of the plasma is increased. The same conclusion can be drawn from the signature ToF-SIMS peaks (m/z = 45 (CH3&61485;O&61485;CH2+ and +CH2CH2&61485;OH), 59 (CH3&61485;O&61485;CH2&61485;CH2+), 103 (CH3&61485;(O&61485;CH2&61485;CH2)2+)) that are decreasing in the case of high power treatments. Accordingly, IRRAS measurements show that the C-O stretching band is decreasing for high power plasma deposition. This is in agreement with the observations made from the analysis of the LP PECVD coatings and from the literature.<p>The films deposited by the APPLD process do not show the same behavior. Indeed, whatever the power injected into the discharge is, we are able to achieve films with a relatively high PEG character (&61566;83 %).<p>The second part of this study is dedicated to the evaluation of the non-fouling properties of the coatings by exposing them to proteins (bovine serum albumin and human fibrinogen) and cells (mouse fibroblasts (L929 and MEF)) and controlling the adsorption with XPS (proteins) and SEM (cells).<p>For the APPECVD samples, a low plasma power (30 W) leads to an important reduction of protein adsorption and cell adhesion (over 85%). However, higher-powered treatments tend to reduce the non-fouling ability of the surfaces (around 50% of reduction for a 80 W deposition). <p>The same order of magnitude (over 90% reduction of the adsorption) is obtained for the APPLD surfaces, whatever is the power of the treatment. <p>Those results show an important difference between the two processes in terms of power of the plasma treatment, and a strong relationship between the surface chemistry and the adsorption behavior: the more the PEG character is preserved, the more protein-repellent and cell-repellent is the surface. / Le rôle d’une couche empêchant l’adsorption de protéines est de limiter les interactions entre un implant et le milieu physiologique auquel il est exposé. Les films de poly(éthylène glycol) polymérisés par plasma (pp-PEG) sont d’intérêt majeur car ils sont connus pour empêcher l’adsorption de protéines ainsi que l’attachement cellulaire. Cependant, dans toutes les études publiées précédemment, les couches de type PEG ont été réalisées sous vide.<p>Dans cette thèse de doctorat, nous synthétisons des couches de type pp-PEG biocompatibles par plasmas à pression atmosphérique. A cette fin, deux méthodes originales ont été développées. 1. La première méthode consiste en l’injection du précurseur, le tetra(éthylène glycol) diméthyl éther (tetraglyme), en phase liquide, en nébulisant ce dernier au moyen d’un spray, directement dans la post-décharge d’une torche à plasma atmosphérique fonctionnant à l’argon. En anglais, nous appelons ce procédé « Atmospheric pressure plasma liquid deposition (APPLD) ». 2. Dans la deuxième méthode, appelée en anglais « Atmospheric pressure plasma-enhanced chemical vapor deposition (APPECVD)», le tetraglyme est amené en phase vapeur dans la post-décharge, au moyen d’un diffuseur chauffant. La composition chimique des dépôts de type APPLD et APPECVD, ainsi que leurs propriétés d’anti-adsorption sont évaluées, et comparées aux dépôts pp-PEG obtenus par les méthodes à basse pression conventionnelles.<p>Dans la première partie de cette étude, nous nous focalisons sur la composition chimique des films déposés, et plus particulièrement sur l’influence de la puissance injectée dans le plasma sur cette composition chimique. A cette fin, nous avons fait appel à des techniques d’analyse telles que la spectroscopie de réflexion-absorption infrarouge (IRRAS), la spectroscopie des photoélectrons X (XPS) et la spectrométrie de masse des ions secondaires (SIMS). <p>Il en ressort que les films de type APPECVD perdent progressivement leur « caractère PEG » à mesure que la puissance de la décharge plasma est élevée. Cela serait dû à une plus grande fragmentation du précurseur dans la post-décharge d’un plasma plus énergétique. Cette tendance est cohérente avec ce que nous avons observé pour les dépôts à basse pression ainsi que dans la littérature.<p>Dans le cas des films de type APPLD, un tel comportement n’a pas été mis en évidence :quelle que soit la puissance dissipée dans le plasma, les films présentent un « caractère PEG » relativement élevé.<p>La deuxième partie de cette thèse est dédiée à l’évaluation des propriétés d’anti-adsorption des films synthétisés, en les exposant à des protéines (albumine de sérum bovin et fibrinogène humain) et des cellules (fibroblastes de souris, L929 et MEF). L’adsorption de protéines est contrôlée par XPS tandis que l’attachement cellulaire est contrôlé par imagerie SEM.<p>Pour les échantillons de type APPECVD, un dépôt à faible puissance (30 W) mène à une importante réduction de l’adsorption de protéines et de cellules (> 85%) tandis qu’à de plus hautes puissances (80 W), l’anti-adsorption est sensiblement diminuée (50% de réduction). Dans le cas des dépôts de type APPLD, quelle que soit la puissance du plasma, une forte diminution de l’adsorption de protéines et de cellules est observée (> 90 %).<p>Ces résultats montrent une différence majeure entre les deux procédés quant à l’influence de la puissance du plasma ainsi qu’une forte relation entre la composition chimique de la surface synthétisée et son pouvoir d’anti-adsorption :plus le « caractère PEG » du dépôt est conservé, plus la surface empêchera l’interaction avec les protéines et les cellules. <p><p> / Doctorat en Sciences / info:eu-repo/semantics/nonPublished

Page generated in 0.0637 seconds