• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Usos e qualidade da ?gua em regi?o semi-?rida do nordeste brasileiro: percep??o ambiental de professores e alunos

Petrovich, Ana Carla Iorio 24 April 2009 (has links)
Made available in DSpace on 2014-12-17T15:54:55Z (GMT). No. of bitstreams: 1 AnaCLP_DISSERT_pagina 1_a_8.pdf: 8605712 bytes, checksum: a23b0324901ca6ee088750e19d1a57c3 (MD5) Previous issue date: 2009-04-24 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / Density and biomass of bacterioplankton in parts of the Marechal Dutra reservoir were studied in periods of dry and rainy season. The averages of the total bacterial densities oscillated in the order of 107 organisms/ mL of sample. The cocci cells were numerically predominant, influencing considerably the total abundance of the bacterioplankton. The total bacterial biomass, was considered raised and varied from 2.431,82 to 2.739,01 ?gC.L-1, in function of the high values of biovolume of the filaments forms, and showed no marked spacial fluctuation. These high values of density and biomass alert for the necessity of a frequent monitoring of aquatic ecosystems of semi-arid region, where the quality of the water is affected by the occurrence of extensive dry periods, influencing considerably the quality of life of its population / Foram estudadas a densidade e a biomassa do bacteriopl?ncton nos per?odos seco e chuvoso em dois pontos do A?ude Marechal Dutra. As m?dias das densidades bacterianas totais oscilaram na ordem de 107 organismos por mL de amostra. As c?lulas em forma de cocos foram numericamente predominantes, influenciando consideravelmente a abund?ncia total do bacteriopl?ncton. A biomassa bacteriana total foi considerada elevada, variando de 2.431,82 a 2.739,01 ?gC.L-1 , em fun??o dos altos valores de biovolume dos filamentos. N?o foram encontradas varia??es espaciais nem sazonais marcantes. Os altos valores de densidade e biomassa encontrados alertam para a necessidade de um freq?ente monitoramento dos ecossistemas aqu?ticos de regi?o semi-?rida onde a qualidade da ?gua ? afetada pela ocorr?ncia de extensos per?odos de estiagem que influenciam a qualidade de vida de sua popula??o
2

Comportamento de filtros rápidos de camada profunda no tratamento de águas de abastecimento mediante o emprego de polímeros como auxiliares de filtração. / Behavior of deep bed rapid filters treating public water supplies through the use of polymers as filter aids.

Abreu, Sergio Brasil 26 June 2009 (has links)
O projeto consistiu em avaliar o emprego de polímeros catiônicos e aniônicos de diferentes pesos moleculares como auxiliares de filtração no tratamento de águas de abastecimento proveniente de mananciais com alto grau de eutrofização com vistas a possibilitar a otimização da remoção de material particulado e minimização da evolução da perda de carga. O aparato experimental é composto, principalmente, por 4 filtros em escala piloto de alta taxa do tipo camada profunda e fluxo descendente por gravidade operados em paralelo. Os filtros possuem 5 m de altura e diâmetro interno de 150 mm. O procedimento experimental foi dividido em três etapas, execução de ensaios de fluidificação e expansão do leito dos filtros e utilização de polímeros catiônicos e de polímero aniônico como auxiliares de filtração. A primeira etapa teve como objetivo definir parâmetros de dimensionamento do sistema de lavagem em contra-corrente com ar e água e nas duas etapas seguintes foram realizados os ensaios de filtração a uma taxa de 500 m³/m²/dia, com a utilização dos polímeros com três dosagens diferentes. Os polímeros utilizados foram CA-2577, CA-2581, CD-2592 e N1986. Estes possuem estrutura e pesos moleculares variáveis, de forma que o trabalho tivesse uma maior amplitude. Os valores médios de turbidez, para a primeira etapa dos ensaios de filtração, foram de 2,36 ± 0,28 UNT e 1,12 ± 0,21 UNT para água bruta e decantada, respectivamente, 0,26 ± 0,07 UNT para o filtro F1 com antracito, 0,25 ± 0,08 UNT para o filtro F3 com antracito e adição de polímero, 0,29 ± 0,08 UNT para o filtro F2 com areia e 0,26 ± 0,08 UNT para o filtro F4 com areia e adição de polímero. Para a segunda etapa dos ensaios de filtração os valores médios de turbidez foram de 2,03 ± 0,36 UNT para água bruta, 0,80 ± 0,21 UNT para água decantada, 0,09 ± 0,03 UNT para o filtro F1, sem adição de polímero, e 0,15 ± 0,04, 0,16 ± 0,03 e 0,10 ± 0,04 UNT para os filtros F2, F3 e F4, respectivamente, todos com adição de polímero. Os resultados experimentais possibilitaram concluir que a adoção do antracito como material filtrante do tipo camada única e profunda apresenta a vantagem de permitir uma menor velocidade ascensional de água de lavagem para uma determinada expansão quando comparado a um filtro de areia de idêntica granulometria. A aplicação dos polímeros catiônicos e do polímero aniônico como auxiliares de filtração não proporcionou para nenhuma dosagem utilizada melhora significativa no comportamento dos filtros. Uma eventual melhora ou piora foi insignificante e estava ligada à qualidade da água decantada. No que diz respeito à perda de carga, os filtros com antracito tiveram carreiras de filtração mais longas quando comparados com os de areia, independente da utilização dos polímeros. / The project was to evaluate the use of anionic and cationic polymers of different molecular weights as filter aids to treat drinking water treatment of surface water sources with high degree of eutrophication, particularly with regard to particulate matter removal optimization and head loss rate minimization. The experimental apparatus was composed of four pilot scale, deep bed, down flow rapid gravity filters, operated in parallel. The filter columns were 5 m high, had inner diameter of 150 mm. The experimental procedure was divided in three stages, conduction of media fluidization and media expansion tests and cationic and anionic polymers application as filter aid. The first stage aims was to define design parameters for the filter backwashing system with water and air and in the two next phases the tests were conducted at a filtration rate of 500 m³/m²/day, with the use of polymers with three different dosages. The polymers tested were CA- 2577, CA-2581, CD-2592 and N1986. They have different structure and molecular weights, thus making wider the array of possibilities tested. The average values of turbidity, for the first stage of testing filtration, were 2.36 ± 0.28 and 1.12 ± 0.21 NTU for raw and settled water, respectively, 0.26 ± 0.07 NTU to the filter F1 with anthracite, 0.25 ± 0.08 NTU for the filter F3 with anthracite and addition of polymer, 0.29 ± 0.08 NTU for the filter F2 with sand and 0.26 ± 0.08 NTU for the filter F4 with sand and the addition of polymer. For the second stage of testing of the filter values of turbidity were 2.03 ± 0.36 NTU for raw water, 0.80 ± 0.21 NTU for settled water, 0.09 ± 0.03 for the filter F1, without the addition of polymer, and 0.15 ± 0.04, 0.16 ± 0.03 and 0.10 ± 0.04 NTU for filters F2, F3 and F4, respectively, all with the addition of polymer. The experimental results led us to conclusion that the adoption of anthracite as single media in deep bed filtration presents the advantage of a lower ascent backwash water velocity for any given bed expansion as compared to deep bed filtration through sand with the same granulometric characteristic. Application of cationic and anionic polymers as filter aids did not lead to any significant improvement in the behavior of pilot scale filters, regardless of applied polymer dosage. Any eventual improvement or worsening was not significant and was closely related to the settled water quality. Regarding the head loss, the filters with anthracite had longer filtration careers when compared to sand, regardless the use of polymers.
3

Comportamento de filtros rápidos de camada profunda no tratamento de águas de abastecimento mediante o emprego de polímeros como auxiliares de filtração. / Behavior of deep bed rapid filters treating public water supplies through the use of polymers as filter aids.

Sergio Brasil Abreu 26 June 2009 (has links)
O projeto consistiu em avaliar o emprego de polímeros catiônicos e aniônicos de diferentes pesos moleculares como auxiliares de filtração no tratamento de águas de abastecimento proveniente de mananciais com alto grau de eutrofização com vistas a possibilitar a otimização da remoção de material particulado e minimização da evolução da perda de carga. O aparato experimental é composto, principalmente, por 4 filtros em escala piloto de alta taxa do tipo camada profunda e fluxo descendente por gravidade operados em paralelo. Os filtros possuem 5 m de altura e diâmetro interno de 150 mm. O procedimento experimental foi dividido em três etapas, execução de ensaios de fluidificação e expansão do leito dos filtros e utilização de polímeros catiônicos e de polímero aniônico como auxiliares de filtração. A primeira etapa teve como objetivo definir parâmetros de dimensionamento do sistema de lavagem em contra-corrente com ar e água e nas duas etapas seguintes foram realizados os ensaios de filtração a uma taxa de 500 m³/m²/dia, com a utilização dos polímeros com três dosagens diferentes. Os polímeros utilizados foram CA-2577, CA-2581, CD-2592 e N1986. Estes possuem estrutura e pesos moleculares variáveis, de forma que o trabalho tivesse uma maior amplitude. Os valores médios de turbidez, para a primeira etapa dos ensaios de filtração, foram de 2,36 ± 0,28 UNT e 1,12 ± 0,21 UNT para água bruta e decantada, respectivamente, 0,26 ± 0,07 UNT para o filtro F1 com antracito, 0,25 ± 0,08 UNT para o filtro F3 com antracito e adição de polímero, 0,29 ± 0,08 UNT para o filtro F2 com areia e 0,26 ± 0,08 UNT para o filtro F4 com areia e adição de polímero. Para a segunda etapa dos ensaios de filtração os valores médios de turbidez foram de 2,03 ± 0,36 UNT para água bruta, 0,80 ± 0,21 UNT para água decantada, 0,09 ± 0,03 UNT para o filtro F1, sem adição de polímero, e 0,15 ± 0,04, 0,16 ± 0,03 e 0,10 ± 0,04 UNT para os filtros F2, F3 e F4, respectivamente, todos com adição de polímero. Os resultados experimentais possibilitaram concluir que a adoção do antracito como material filtrante do tipo camada única e profunda apresenta a vantagem de permitir uma menor velocidade ascensional de água de lavagem para uma determinada expansão quando comparado a um filtro de areia de idêntica granulometria. A aplicação dos polímeros catiônicos e do polímero aniônico como auxiliares de filtração não proporcionou para nenhuma dosagem utilizada melhora significativa no comportamento dos filtros. Uma eventual melhora ou piora foi insignificante e estava ligada à qualidade da água decantada. No que diz respeito à perda de carga, os filtros com antracito tiveram carreiras de filtração mais longas quando comparados com os de areia, independente da utilização dos polímeros. / The project was to evaluate the use of anionic and cationic polymers of different molecular weights as filter aids to treat drinking water treatment of surface water sources with high degree of eutrophication, particularly with regard to particulate matter removal optimization and head loss rate minimization. The experimental apparatus was composed of four pilot scale, deep bed, down flow rapid gravity filters, operated in parallel. The filter columns were 5 m high, had inner diameter of 150 mm. The experimental procedure was divided in three stages, conduction of media fluidization and media expansion tests and cationic and anionic polymers application as filter aid. The first stage aims was to define design parameters for the filter backwashing system with water and air and in the two next phases the tests were conducted at a filtration rate of 500 m³/m²/day, with the use of polymers with three different dosages. The polymers tested were CA- 2577, CA-2581, CD-2592 and N1986. They have different structure and molecular weights, thus making wider the array of possibilities tested. The average values of turbidity, for the first stage of testing filtration, were 2.36 ± 0.28 and 1.12 ± 0.21 NTU for raw and settled water, respectively, 0.26 ± 0.07 NTU to the filter F1 with anthracite, 0.25 ± 0.08 NTU for the filter F3 with anthracite and addition of polymer, 0.29 ± 0.08 NTU for the filter F2 with sand and 0.26 ± 0.08 NTU for the filter F4 with sand and the addition of polymer. For the second stage of testing of the filter values of turbidity were 2.03 ± 0.36 NTU for raw water, 0.80 ± 0.21 NTU for settled water, 0.09 ± 0.03 for the filter F1, without the addition of polymer, and 0.15 ± 0.04, 0.16 ± 0.03 and 0.10 ± 0.04 NTU for filters F2, F3 and F4, respectively, all with the addition of polymer. The experimental results led us to conclusion that the adoption of anthracite as single media in deep bed filtration presents the advantage of a lower ascent backwash water velocity for any given bed expansion as compared to deep bed filtration through sand with the same granulometric characteristic. Application of cationic and anionic polymers as filter aids did not lead to any significant improvement in the behavior of pilot scale filters, regardless of applied polymer dosage. Any eventual improvement or worsening was not significant and was closely related to the settled water quality. Regarding the head loss, the filters with anthracite had longer filtration careers when compared to sand, regardless the use of polymers.

Page generated in 0.059 seconds