• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 1
  • Tagged with
  • 24
  • 24
  • 15
  • 12
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Proposta de um sistema de captação de águas pluviais para redução de custo com abastecimento: caso IFAM-CMC

Barreto, Renato Costa Mena 30 December 2013 (has links)
Made available in DSpace on 2015-04-23T12:43:16Z (GMT). No. of bitstreams: 1 Renato Costa Mena Barreto.pdf: 3450302 bytes, checksum: e99f2daba600a6692855f43be888a898 (MD5) Previous issue date: 2013-12-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The capture of rainwater can be a quick way to obtain large volumes of water, and of reasonable quality, coupled with the possibility of using the roof of the building, the channeling of water abstracted to a reservoir for later use. Propose a system for rainwater harvesting in order to reduce supply costs with the Federal Institute Amazonas - Manaus Campus Center IFAM - CMC. Introducing calculations with the method Rippl: Analytical and Chart for sizing reservoirs. The use of a confidence interval of 95 % for each month of the years 1961 to 2012 provided by the Institute of Meteorology INMET also capture points considering the entire roof area of the institution the minimum, average and maximum values of potential funding storm water prove the feasibility of implementing a system of rainwater_harvesting. . / A captação da água de chuva pode ser uma maneira rápida de se obter grandes volumes de água, e de razoável qualidade, somado com a possibilidade de aproveitamento do telhado da edificação, a canalização da água captada até um reservatório, para posterior utilização. Propor um sistema de captação de águas pluviais como forma de diminuir custos com abastecimento no Instituto Federal Amazonas - Campus Manaus Centro - IFAM-CMC. Apresentando cálculos com o método de Rippl: Analítico e Gráfico para dimensionamento de reservatórios. A utilização de um intervalo de confiança de 95% para todos os meses dos anos do período de 1961 a 2012 fornecidos pelo Instituto de Meteorologia INMET também os pontos de captação considerando toda a área de telhado da Instituição. Os valores mínimos, médios e máximos de potenciais de captações de águas pluviais comprovam a viabilidade da implantação de um sistema de captação de águas pluviais.
2

Qualidade da água no sistema de captação e na estação de tratamento de água Fonte Luminosa, Araraquara (SP) / Water quality at the Fonte Luminosa water treatment plant, Araraquara (SP)

Takenaka, Renata Akemi 24 October 2002 (has links)
O presente trabalho teve como objetivo analisar a qualidade da água das represas de captação do Ribeirão das Anhumas e do Ribeirão das Cruzes, bem como da água tratada da estação de tratamento Fonte Luminosa, no município de Araraquara (SP). Para tanto, foram realizadas análises das características físicas, químicas e biológicas da água, estudo de comunidade fitoplanctônica, e testes de toxidade aguda e crônica com o microcrustáceo Ceriodaphnia silvestrii (Cladocera, Crustacea). O período de estudo foi de dezembro de 2000 a novembro de 2001. Na água da represa da Ribeirão das Anhumas, a concentração de oxigênio dissolvido foi, em geral, inferior ao limite estabelecido pela legislação para águas naturais. Tanto na água da represa do Ribeirão das Cruzes como em Anhumas, alguns metais apresentaram concentrações superiores ao limite estabelecido pela legislação para águas naturais. Na água tratada, alguns metais também apresentaram concentrações superiores ao limite estabelecido pela legislação para água potável. As águas das represas de captação não causaram toxicidade aguda nem crônica ao organismo-teste. A água da entrada (após aplicação de cal) da estação de tratamento causou efeitos crônicos principalmente sobre a fecundidade do organismo-teste. A água tratada causou toxicidade aguda e crônica ao organismo-teste. As diatomáceas (Bacillariophyceae) foram dominantes na represa do Ribeirão das Cruzes e, principalmente, em Anhumas. As algas Chlorophyceae foram as mais abundantes na água tratada em ambos os períodos estudados. / The present work analysed the water quality of the reservoirs Ribeirão das Cruzes and Ribeirão das Anhumas, used to store and supply water for the Fonte Luminosa water treatment plant, in Araraquara, SP. For that, physical, chemical and biological analyses of water were performed, as well as a study of phytoplankton community. The work also included acute and chronic toxicity testing of the water before and after treatment with the microcrustacean Ceriodaphnia silvestrii (Cladocera, Crustacea) as a test organism. The period of study was between December/2000 to November/2001. Dissolved oxygen was below the established limit by legislation for natural waters at the Ribeirão das Anhumas reservoir. Some metals in the Ribeirão das Anhumas and Ribeirão das Cruzes reservoirs were over the established limit by legislation for natural waters. Some metaIs in treated water were also over legislation for potable water. Reservoir waters did not cause neither acute nor chronic toxicity on test organism. Water with lime, from water treatment plant, caused chronic effects on the reproduction of the test organism. Treated water cause acute and chronic toxicity on test organism, with harmful effects on survival and reproduction. Diatoms (Bacillariophyceae) dominated in the phytoplankton of Ribeirão das Cruzes and Ribeirão das Anhumas reservoirs. Chlorophyceae were the most abundant algae in treated water.
3

Qualidade da água no sistema de captação e na estação de tratamento de água Fonte Luminosa, Araraquara (SP) / Water quality at the Fonte Luminosa water treatment plant, Araraquara (SP)

Renata Akemi Takenaka 24 October 2002 (has links)
O presente trabalho teve como objetivo analisar a qualidade da água das represas de captação do Ribeirão das Anhumas e do Ribeirão das Cruzes, bem como da água tratada da estação de tratamento Fonte Luminosa, no município de Araraquara (SP). Para tanto, foram realizadas análises das características físicas, químicas e biológicas da água, estudo de comunidade fitoplanctônica, e testes de toxidade aguda e crônica com o microcrustáceo Ceriodaphnia silvestrii (Cladocera, Crustacea). O período de estudo foi de dezembro de 2000 a novembro de 2001. Na água da represa da Ribeirão das Anhumas, a concentração de oxigênio dissolvido foi, em geral, inferior ao limite estabelecido pela legislação para águas naturais. Tanto na água da represa do Ribeirão das Cruzes como em Anhumas, alguns metais apresentaram concentrações superiores ao limite estabelecido pela legislação para águas naturais. Na água tratada, alguns metais também apresentaram concentrações superiores ao limite estabelecido pela legislação para água potável. As águas das represas de captação não causaram toxicidade aguda nem crônica ao organismo-teste. A água da entrada (após aplicação de cal) da estação de tratamento causou efeitos crônicos principalmente sobre a fecundidade do organismo-teste. A água tratada causou toxicidade aguda e crônica ao organismo-teste. As diatomáceas (Bacillariophyceae) foram dominantes na represa do Ribeirão das Cruzes e, principalmente, em Anhumas. As algas Chlorophyceae foram as mais abundantes na água tratada em ambos os períodos estudados. / The present work analysed the water quality of the reservoirs Ribeirão das Cruzes and Ribeirão das Anhumas, used to store and supply water for the Fonte Luminosa water treatment plant, in Araraquara, SP. For that, physical, chemical and biological analyses of water were performed, as well as a study of phytoplankton community. The work also included acute and chronic toxicity testing of the water before and after treatment with the microcrustacean Ceriodaphnia silvestrii (Cladocera, Crustacea) as a test organism. The period of study was between December/2000 to November/2001. Dissolved oxygen was below the established limit by legislation for natural waters at the Ribeirão das Anhumas reservoir. Some metals in the Ribeirão das Anhumas and Ribeirão das Cruzes reservoirs were over the established limit by legislation for natural waters. Some metaIs in treated water were also over legislation for potable water. Reservoir waters did not cause neither acute nor chronic toxicity on test organism. Water with lime, from water treatment plant, caused chronic effects on the reproduction of the test organism. Treated water cause acute and chronic toxicity on test organism, with harmful effects on survival and reproduction. Diatoms (Bacillariophyceae) dominated in the phytoplankton of Ribeirão das Cruzes and Ribeirão das Anhumas reservoirs. Chlorophyceae were the most abundant algae in treated water.
4

Aplicação da análise de perigos e pontos críticos de controle no tratamento de água para consumo humano / Application of hazard analysis and critical control points to drinking water treatment

Oliveira, Daniel Cobucci de 22 March 2010 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2015-11-03T13:50:36Z No. of bitstreams: 1 texto completo.pdf: 5799471 bytes, checksum: 2011bc9ea678e0f76c7163f828014e87 (MD5) / Made available in DSpace on 2015-11-03T13:50:36Z (GMT). No. of bitstreams: 1 texto completo.pdf: 5799471 bytes, checksum: 2011bc9ea678e0f76c7163f828014e87 (MD5) Previous issue date: 2010-03-22 / Este trabalho visa discutir a aplicação da metodologia de Análise de Perigos e Pontos Críticos de Controle em estações de tratamento de água para consumo humano, por meio de estudos de caso em estações de tratamento de água para consumo humano que operam com ciclo completo, quais sejam: ETA UFV - responsável pelo abastecimento de água do 'campus' da Universidade Federal de Viçosa e ETA SAAE I e II, responsáveis pelo abastecimento de água da área urbana do município de Viçosa - MG. A dissertação foi desenvolvida seguindo, basicamente, a sequência de passos para implantação do sistema APPCC, ou seja: (i) etapas preliminares; (ii) identificação de perigos; (iii) identificação de pontos críticos de controle; (iv) estabelecimento de limites críticos; (v) definição do monitoramento dos PCC; (vi) estabelecimento das medidas corretivas. Vale ressaltar que o presente trabalho restringe-se à avaliação de perigos microbiológicos. Como resultado foram identificados como perigos microbiológicos as bactérias, os vírus e os protozoários, que são os principais perigos presentes nos mananciais e estações de tratamento de água. Sendo que neste trabalho foram monitorados e detectados nos pontos de captação dos mananciais que abastecem os sistemas em estudo a presença de Giardia spp., Cryptosporidium spp., coliformes totais e Escherichia coli. Para identificação dos pontos críticos de controle foi aplicada a árvore de decisão proposta por Vieira 2005. Considerando os resultados obtidos e as diferenças entre o trabalho de Viera e este viu-se a necessidade de proposição de adaptações a arvore de decisão. Neste sentido foram incorporados os conceitos de pontos de atenção e pontos de controle, além dos tradicionais pontos críticos de controle. Com as adaptações na árvore de decisão foram identificados como: (i) PCC para o perigo protozoários as etapas de coagulação, floculação, decantação e filtração, demonstrando que as estações em estudo necessitam de adequações; (ii) PCC para o perigo bactérias/vírus a etapa de desinfecção, sendo as etapas que antecedem a desinfecção consideradas pontos de controle. Os limites críticos foram estabelecidos com base no padrão de potabilidade vigente. Foram estabelecidos também limites operacionais através da avaliação de desempenho das estações e banco de dados do monitoramento de rotina das mesmas. / The dissertation was developed by basically following the implementation steps of the HACCP system: (i) preliminary stages; (ii) hazard identification; (iii) identification of critical control points (CCP); (iv) establishment of critical limits; (v) establishment of critical control point monitoring; (vi) establishment of corrective measures. The scope of the present study is restricted to microbiological hazards. The microbiological hazards were identified as being bacteria, viruses, and protozoa, Which are the main hazards found in water sources and water treatment plants. The presence of Giardia spp., Cryptosporidium spp., total coliform and Escherichia coli were detected and monitored at the sources that feed the systems under investigation. In order to identify the critical control points, the decision tree proposed by Vieira 2005 was applied. Considering the results obtained and the differences between this study and Vieiraºs, adaptations to the decision tree were found necessary. As a result, in addition to the traditional critical control points, the concepts of attention points and control points were incorporated. With the adaptations to the decision tree, the following points were identified: (i) CCP for protozoa hazard were the coagulation, flocculation, decantation, and filtration stages; (ii) CCP for bacterial/viral hazards was the disinfection stage, While the stages preceding disinfection were considered as control points. The critical limits were established based on the current potability standards. Operational limits were also established through performance evaluations of the plants and the routine monitoring databases of these plants.
5

Biological treatment of pulp and paper mill effluents with aerobic granular sludge / Tratamento biológico de efluentes de fábrica de polpa celulósica e papel com lodo aeróbio granular

Morais, Ismarley Lage Horta 15 December 2016 (has links)
Submitted by Cleber Casali (clebercasali@ufv.br) on 2017-01-23T18:48:59Z No. of bitstreams: 1 texto completo.pdf: 971488 bytes, checksum: 19e0c0d9a60547273b821e1120b83e1b (MD5) / Made available in DSpace on 2017-01-23T18:48:59Z (GMT). No. of bitstreams: 1 texto completo.pdf: 971488 bytes, checksum: 19e0c0d9a60547273b821e1120b83e1b (MD5) Previous issue date: 2016-12-15 / O tratamento de águas residuárias com lodo aeróbio granular apresenta muitas vantagens em comparação ao processo convencional de lodos ativados com lodo floculento. Os grânulos são agregados microbianos densos e compactos que possibilitam uma maior retenção de biomassa no reator biológico e uma elevada capacidade de sedimentação, favorecendo a remoção biológica de matéria orgânica, nutrientes, compostos tóxicos e clarificação final do efluente devido à estrutura e propriedade de sedimentação do lodo. Estes benefícios resultaram em um aumento do interesse de implantação do processo de tratamento com lodo aeróbio granular e a busca de maiores informações à respeito da formação, estabilidade e a influência dos parâmetros operacionais sobre a granulação. Assim, este trabalho apresenta uma revisão bibliográfica com a compilação das informações recentes sobre o lodo aeróbio granular incluindo a possibilidade de utilização dos grânulos aeróbios em biorreatores a membrana, em elevadas temperaturas e as aplicações em plantas de tratamento de larga escala. Foi realizada, ainda, a avaliação da adição de 100 mg.L-1 e 200mg.L-1 de cálcio na estabilidade, resistência mecânica e diâmetro dos grânulos formados em reatores em batelada sequencial alimentados com efluente de uma fábrica de polpa celulósica kraft. Os reatores apresentaram eficiências similares de remoção de matéria orgânica e o diâmetro médio dos grânulos foi de cerca de 11 mm em todos os reatores, embora os grânulos formados no reator que recebeu 100 mg.L-1 de Ca2+ apresentou velocidade de sedimentação 36% superior aos demais e maior resistência mecânica. A melhoria da granulação pode ser obtida ainda pela seleção de microrganismos que contribuem para a formação dos agregados. A produção de substâncias poliméricas extracelulares (SPE) pelas bactérias é um dos fatores que influencia a agregação celular, uma vez que as SPE agem como agente cimentante e atuam na adesão entre as células. A produção de SPE de dezenove isolados microbianos, obtidos de grânulos aeróbios formados no tratamento de efluente de fábrica de papel reciclado foi avaliada e seis isolados dos gêneros Staphylococcus, Agrobacterium, Enterobacter e Rhodococcus melhoraram a granulação biológica. A ausência destes isolados nos testes de co-agregação reduziu a relação entre proteínas e polissacarídeos (relação PN/PS) e diminuiu a formação de agregados. / Aerobic granular sludge wastewater treatment has many advantages over the conventional activated sludge process. The granules are dense and compact microbial aggregates that allow a higher biomass retention in the biological reactor and a high settling velocity, favoring the biological removal of organic matter, nutrients, toxic substances and improves wastewater clarification. Due to the sludge structure and settleability, these benefits have attracted considerable interest in the implementation of the aerobic granular sludge process and givenrise to the need for better understanding of the formation, stability and influence of the operational parameters on the granulation. Thus, this work was divided into three chapters. Chapter 1 presents a review of recent developments on aerobic granular sludge including the possibility of using aerobic granules in membrane bioreactors, at high temperatures and for a full-scale implementation. The addition of divalent cations in the reactors can enhance granulation and granule stability. In Chapter 2, the effect of the addition of 100 mg.L-1 and 200 mg.L- of calcium in the stability, mechanical strength and diameter of the granules formed in sequential batch reactors (SBR) fed with pulp mill effluent was evaluated. The reactors showed similar organic matter removal efficiencies and granule size was approximately 11 mm in all SBR, although the granules formed in the reactor with addition of 100 mg.L- of Ca2+ had a settling velocity 36% higher and greater mechanical resistance than the others. Granulation can also be enhanced by the selection of microorganisms that contribute to the aggregates formation. Bacterial extracellular polymeric substances (EPS) production is one factor that contributes to cell aggregation, since EPS acts as an intercellular cement that may reinforce cohesion inside the bacterial clusters. In Chapter 3, EPS production of nineteen microbial isolates obtained from aerobic granules formed in the recycled paper wastewater treatment was evaluated and six isolates of the genera Staphylococcus, Agrobacterium, Enterobacter and Rhodococcus contributed to biological granulation. The absence of these isolates in the co-aggregation tests reduced the protein-polysaccharide ratio (PN / PS ratio) and reduced the aggregates formation.
6

Determinação dos parâmetros do modelo pressão x vazamento para sub-setores da rede de distribuição de água de São Carlos - SP / Determination of the parameters of the pressure x leakage model for sub-sectors of São Carlos city

Caliman, Rodrigo de Oliveira 02 August 2002 (has links)
As redes de distribuição constituem importantes infra-estruturas por serem responsáveis pelo abastecimento de água à população. Dessa maneira, tanto o projeto, como a operação e a manutenção dessas infra-estruturas devem ser eficientes, visando manter a sustentabilidade do recurso natural distribuído através das mesmas. Devido à idade das redes, pressões excessivas nos condutos e outros fatores, as perdas por vazamento representam, nos dias de hoje, grande parte de toda água bombeada e tratada quimicamente para o consumo populacional. Com o objetivo de minimizar essas perdas, este trabalho visa a determinação dos parâmetros do modelo hidráulico para sub-setores da cidade de São Carlos, onde as perdas por vazamentos mostram-se expressivas. Os referidos parâmetros foram determinados através do modelo inverso de minimização dos desvios entre dados de campo observados e valores simulados por modelo hidráulico, usando algoritmos genéticos (AGs). O estudo constitui parte integrante do projeto intitulado \"controle operacional em subsistema urbano de distribuição de água\", apoiado pelo FINEP, em andamento. / The water supply networks are very important structures for human consumption. This way, the project as well as the operation and maintenance of such systems must be efficient, focusing on keeping the sustainability of this natural resource. Due to the age of the networks, excessive pressure inside the pipes and other factors, leakage nowadays represents a considerable loss of the total pumped and chemically treated water which is to be supplied to the population. Trying to minimize theses losses, this study sets out to determine the parameters for the pressure x leakage model, applying it to sub-sectors of São Carlos city network, SP, where leakage represents a considerable amount. The referred parameters determination is realized through the inverse minimization model of differences between data observed in field and those simulated values by a hydraulic model, using genetic algorithms (GAs).
7

Tratamento de esgoto urbano em reatores UASB com uso de microrganismos eficientes / Urban sewage treatment in UASB reactors with the use of effective microorganisms

França, Bruna Thomazinho 11 December 2018 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2019-02-25T11:12:15Z No. of bitstreams: 1 texto completo.pdf: 2065992 bytes, checksum: fc539640a5507d3ec970b1c692461946 (MD5) / Made available in DSpace on 2019-02-25T11:12:15Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2065992 bytes, checksum: fc539640a5507d3ec970b1c692461946 (MD5) Previous issue date: 2018-12-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Microrganismos Eficientes constituem uma comunidade de indivíduos aeróbios e anaeróbios que desempenham funções benéficas ao meio ambiente e são capazes de se desenvolver em diversos ecossistemas. Neste trabalho, a técnica de Microrganismos Eficientes (EM Technology®) foi aplicada com o objetivo de verificar se esses organismos são capazes de conferir melhorias no tratamento de esgoto urbano. O aparato experimental foi constituído de dois reatores UASB de bancada e somente um foi inoculado com Microrganismos Eficientes. Os reatores operaram durante 90 dias com tempos de detenção hidráulica de 12, 9 e 6 horas e foram avaliadas as eficiências de remoção de matéria orgânica e nutriente, bem como o processo de granulação anaeróbia. A eficiência dos processos foi analisada em termos de remoção de DQO, DBO 5 e nitrogênio amoniacal enquanto que o processo de granulação foi examinado por meio de testes de resistência ao cisalhamento do grânulo e quantificação de EPS (substâncias poliméricas extracelulares). Análises de diversidade microbiana dos domínios Bacteria e Archaea foram realizadas com o intuito de avaliar se o inóculo provocou alterações nas comunidades dos reatores em termos de diversidade de espécies dentro do período operacional proposto. Os resultados apontam que o inóculo de Microrganismos Eficientes não foi capaz de provocar diferença (a 5% de significância) na eficiência de remoção de compostos orgânicos e nutrientes do sistema. Os testes de resistência ao cisalhamento dos grânulos e de quantificação de EPS apontam que a presença dos Microrganismos Eficientes gerou grânulos mais resistentes e com melhores propriedades de agregação. O inóculo de Microrganismos Eficientes apresentou elevada abundância e baixa diversidade de espécies se comparado às amostras de lodo analisadas. As espécies com maior abundância no inóculo não foram capazes de sobreviver dentro do reator no período proposto. A elevada abundância de Archaeas metanogênicas acetoclásticas nos dois reatores, indicou que esses organismos contribuíram para processo de granulação dos reatores e conseguiram completar o seu ciclo de reações, gerando um efluente tratado com baixa carga orgânica. / Effective Microorganisms are a community of aerobic and anaerobic individuous which performed beneficial functions for the environment and are capable of developing in various ecosystems. In this work, the Effective Microorganisms technique (EM Technology®) was applied in order to verify whether these organisms, widely used in agriculture, are capable of enhancing domestic wastewater treatment. Two UASB bench reactors were built and one was inoculated with Effective Microorganisms to evaluate the performance of the inoculum. The UASB reactors were operated at hydraulic retention times of 12, 9 and 6 hours for thirty days each (90 days total) during which treatment efficiency and anaerobic granulation were compared. Treatment efficiency was analyzed in terms of COD, BOD 5 and ammonium removals while granulation was examined by measuring granule shear strength and extracellular polymeric substances (EPS) contents. In order to evaluate the difference in microbial communities caused by the inoculum during the operational period, analyses of microbial richness and abundance of the domains Bacteria and Archaea were performed. Results showed that the inoculum of Effective Microorganisms did not affect (5% significance level) organic matter and nutrient removals. Granules shear strengh tests and EPS contents indicated that inoculation with Effective Microorganisms resulted in more resistent granules, with better agregation properties. The Effective Microorganisms inoculum presented a higher species abundance, but lower diversity when compared to sludge samples analysed. Moreover, the more abundant species in the inoculum were not capable of developing in the reactor during the operational period. The high abundance of acetotrophic metanogen Archaeas in both reactors, considering the total number of reads, indicated that these organisms contributed to the granulation process in the reators and were able to complete their reaction cycle, generating treated wastewater with low organic load.
8

Avaliação da formação de trialometanos considerando o uso de cloro e permanganato de potássio como pré-oxidantes em águas de abastecimento / Evaluation of Formation of Trihalomethanes considering the Use of Chlorine and potassium permanganate as pre-oxidants in drinking water supplies

Agrizzi, Alexandre Demo 25 February 2011 (has links)
Made available in DSpace on 2016-12-23T14:04:32Z (GMT). No. of bitstreams: 1 Alexandre Demo Agrizzi.pdf: 7003943 bytes, checksum: 32fa12e406ceb8e9b8ef241ea1ee79ed (MD5) Previous issue date: 2011-02-25 / O cloro tem sido utilizado como principal pré-oxidante da matéria orgânica, inativando microrganismos patogênicos que vivem em águas naturais há mais de cem anos. A matéria orgânica encontrada em mananciais superficiais contém substâncias húmicas que podem reagir com o cloro, gerando compostos orgânicos halogenados potencialmente cancerígenos, destacando-se os trialometanos. Os principais trialometanos que se formam são o clorofórmio, o bromodiclorometano, o dibromoclorometano e o bromofórmio, e, a soma das concentrações destes quatro subprodutos é denominada trialometanos totais. Nas estações de tratamento de água (ETAs), a etapa de pré-oxidação com o cloro contribui significativamente para a formação desses compostos. A presente pesquisa teve como objetivo avaliar a formação de trialometanos após o tratamento convencional de água a partir da simulação de quatro rotas distintas em ensaios de bancada (jarteste), além de amostras retiradas diretamente das ETAs envolvidas no estudo. Os trialometanos foram quantificados por cromatografia gasosa com detector de captura de elétrons. Foram coletadas amostras de água bruta de dois mananciais do estado do Espírito Santo (Rio Jucu e Rio Sahy), com cor, absorvância em 254 nm e turbidez diferentes. Foram testados dois oxidantes nas análises: o cloro (na forma de hipoclorito de cálcio) e o permanganato de potássio. Os resultados obtidos mostraram que a formação de trialometanos foi menor quando as amostras de água foram tratadas com permanganato de potássio na etapa de pré-oxidação, quando comparadas com as amostras tratadas com cloro. Resultado semelhante ocorreu no potencial de formação de trialometanos de 24 horas. Em relação ao potencial de formação de sete dias, ambos mananciais mostraram ser capazes de formar compostos precursores dos trialometanos. Concentrações de trialometanos acima do limite permitido pela Portaria do Ministério da Saúde nº 518 (2004) foram detectadas somente nas amostras de água tratada do Rio Sahy / Chlorine has been used as the main pre-oxidation of organic matter, inactivating pathogenic microorganisms that live in fresh water for over one hundred years. The organic matter found in surface waters containing humic substances that can react with chlorine, generating potentially carcinogenic halogenated organic compounds, especially trihalomethanes. The main trihalomethanes that are formed are chloroform, bromodichloromethane, bromoform and the dibromochloromethane, and the sum of the concentrations of these four products is called total trihalomethanes. In water treatment plants (WTP), the stage of pre-oxidation with chlorine significantly contributes to the formation of these compounds. This research aimed to evaluate the formation of trihalomethanes after conventional treatment of water from the simulation of four different routes in bench tests (Jar-test), and specimens removed from the water treatment plants in the study. The trihalomethanes were quantified by gas chromatography with electron capture detector. Samples were collected from raw water from two springs of the state of Espirito Santo (Jucu and Sahy River), with different color, absorbance at 254 nm and turbidity. Two Oxidants were tested in analyses: chlorine (as calcium hypochlorite) and potassium permanganate. The results showed that the formation of trihalomethanes was lower when the water samples were treated with potassium permanganate in the pre-oxidation, when compared with samples treated with chlorine. A similar result occurred in the potential for trihalomethane formation for 24 hours. In relation to the potencial formation of seven days, both springs were shown to be capable of forming compounds precursors of trihalomethanes. Concentrations of trihalomethanes above the limit allowed by the Ordinance of Ministry of Health number 518 were only detected in samples of treated water from the Sahy River
9

Determinação dos parâmetros do modelo pressão x vazamento para sub-setores da rede de distribuição de água de São Carlos - SP / Determination of the parameters of the pressure x leakage model for sub-sectors of São Carlos city

Rodrigo de Oliveira Caliman 02 August 2002 (has links)
As redes de distribuição constituem importantes infra-estruturas por serem responsáveis pelo abastecimento de água à população. Dessa maneira, tanto o projeto, como a operação e a manutenção dessas infra-estruturas devem ser eficientes, visando manter a sustentabilidade do recurso natural distribuído através das mesmas. Devido à idade das redes, pressões excessivas nos condutos e outros fatores, as perdas por vazamento representam, nos dias de hoje, grande parte de toda água bombeada e tratada quimicamente para o consumo populacional. Com o objetivo de minimizar essas perdas, este trabalho visa a determinação dos parâmetros do modelo hidráulico para sub-setores da cidade de São Carlos, onde as perdas por vazamentos mostram-se expressivas. Os referidos parâmetros foram determinados através do modelo inverso de minimização dos desvios entre dados de campo observados e valores simulados por modelo hidráulico, usando algoritmos genéticos (AGs). O estudo constitui parte integrante do projeto intitulado \"controle operacional em subsistema urbano de distribuição de água\", apoiado pelo FINEP, em andamento. / The water supply networks are very important structures for human consumption. This way, the project as well as the operation and maintenance of such systems must be efficient, focusing on keeping the sustainability of this natural resource. Due to the age of the networks, excessive pressure inside the pipes and other factors, leakage nowadays represents a considerable loss of the total pumped and chemically treated water which is to be supplied to the population. Trying to minimize theses losses, this study sets out to determine the parameters for the pressure x leakage model, applying it to sub-sectors of São Carlos city network, SP, where leakage represents a considerable amount. The referred parameters determination is realized through the inverse minimization model of differences between data observed in field and those simulated values by a hydraulic model, using genetic algorithms (GAs).
10

Remoção de compostos biologicamente ativos em sistemas convencionais de tratamento de esgotos domésticos / Removal of biologically active compounds in conventional domestic wastewater treatment plants

Magalhães, Déborah Neide de 26 February 2016 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2017-06-06T13:30:10Z No. of bitstreams: 1 texto completo.pdf: 3420825 bytes, checksum: 01efcef37a91ed531386161c4808b5d1 (MD5) / Made available in DSpace on 2017-06-06T13:30:10Z (GMT). No. of bitstreams: 1 texto completo.pdf: 3420825 bytes, checksum: 01efcef37a91ed531386161c4808b5d1 (MD5) Previous issue date: 2016-02-26 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Os esgotos domésticos são misturas complexas que, mesmo após passar pelo tratamento biológico, ainda podem apresentar toxicidade e microcontaminantes em concentrações capazes de trazer prejuízos ao ambiente, sobretudo em locais onde não há legislação específica para esse caráter. A presente pesquisa teve por objetivos traçar um panorama dos estudos sobre toxicidade e microcontaminantes em esgotos sanitários realizados no Brasil e fazer um estudo em escala real, da remoção de compostos biologicamente ativos em três sistemas convencionais de tratamento de esgotos sanitários comumente empregados no país. O levantamento bibliográfico demonstrou que a remoção de toxicidade e microcontaminantes nas diversas tecnologias avaliadas é dependente de parâmetros estruturais e operacionais, sendo possível alcançar índices satisfatórios de remoção com a adequação desses parâmetros, com os lodos ativados apresentando os melhores resultados. Foi possível observar que a produção de dados no país ainda é bastante incipiente em muitas regiões, com as pesquisas estando mais concentradas nas regiões sudeste e sul. A avaliação de parâmetros físicos e químicos de três sistemas com diferentes tecnologias de tratamento: lodos ativados, UASB/filtro biológico percolador (FBP), tanque séptico/filtro anaeróbio) demonstrou que o tratamento aeróbio foi mais eficiente na remoção de matéria orgânica e nutrientes em relação aos outros dois sistemas, com eficiências de remoção de DQO acima de 90%, e até 70% nos outros dois. Quanto às toxicidades aguda e crônica aos organismos Daphnia similis e Ceriodaphnia dubia, os três sistemas foram capazes de reduzir ou remover os efeitos tóxicos, com o sistema de lodos ativados removendo de 87 a 100%. Nos sistemas anaeróbios, a toxicidade não foi completamente removida e efluente do sistema constituído de UASB/FBP foi o que apresentou potencial para causar toxicidade no corpo receptor. As amostras ainda foram submetidas a um protocolo de avaliação e identificação da toxicidade que revelou que os agentes tóxicos presentes são eliminados em pH ácido, com tratamentos adicionais que envolvam a volatilização ou oxidação. Com relação aos microcontaminantes, as amostras dos três sistemas foram submetidas ao ensaio YES (Yeast Estrogen Screen) para avaliação de atividade estrogênica e à análise cromatográfica por CG/EM para a identificação de compostos estrogênicos. Os resultados do ensaio YES revelaram que o sistema de lodos ativados foi o que apresentou melhor eficiência na remoção da estrogenicidade, com carga média afluente de 9,2 mg equivalentes de 17-β estradiol (EQ-E2)/dia, e efluente de 0,3 mg EQ-E2/dia. O sistema composto por UASB / FBP apresentou remoção mínima (1,8 e 1,5 ng EQ-E2/L, para entrada e saída, respectivamente) e o de tanque séptico/filtro anaeróbio registrou acréscimo da atividade estrogênica de 1,6 ng EQ-E2/L na entrada para 2,3 ng EQ-E2/L na saída, no período amostrado. Os resultados qualitativos das análises cromatográficas revelaram a detecção esporádica dos hormônios naturais estrona, 17-β estradiol e estradiol e o sintético 17-β-etinilestradiol nos três sistemas. Os alquilfenóis 4-octil e 4-nonilfenol foram raramente detectados, enquanto o bisfenol A foi o analito mais frequentemente detectado nas amostras. Foram detectados hormônios em amostras de sedimento do ponto de lançamento dos efluentes dos sistemas anaeróbios, os quais não estavam presentes nas amostras de sedimento a montante do lançamento, sugerindo a contribuição dos efluentes tratados nesses sistemas para a contaminação do sedimento. / Domestic wastewaters are complex mixtures that can still present toxicity and microcontaminants at concentrations capable of causing environmental harm even after biological treatment, especially where no specific discharge limits for such characteristics exists. The objectives of this research were to present a panorama of Brazilian studies on domestic wastewater toxicity and microcontaminant removal and to monitor removal of toxicity in three full-scale wastewater treatment plants that operate different, commonly used biological processes, over the course of a year. The literature review on Brazilian research demonstrated that toxicity and microcontaminant removal by the various technologies evaluated depends on system design and operational parameters and that satisfactory removal efficiencies can be achieved by properly adjusting these parameters, with the activated sludge process presenting the best results. It was also observed that research in this field is still quite incipient in many regions of Brazil, with most studies concentrated in the southern and southeastern states. Evaluation of physical and chemical parameters in the three full- scale systems - activated sludge (AS), UASB reactor-trickling filter (UASB/TF) and septic tank-anaerobic filter (ST/AF) – showed that the fully aerobic AS process was more efficient than the others in removing organic matter and nutrients, with COD removal over 90% for the AS system and up to 70% in the other two. All three systems were able to reduce or remove acute toxicity to Daphnia similis and chronic toxicity to Ceriodaphnia dubia, with 87-100% removal in the AS plant. Toxicity was not completely removed in the ST/AF and UASB/TF systems and the treated wastewater at the outlet of the latter presented potential to cause toxicity in the receiving water. Phase I toxicity identification evaluations were carried out on all toxic system inlet and outlet samples and it was found that toxicity was most consistently reduced or eliminated after aeration at acid pH, suggesting oxidation and, or volatilization of acidic substances as probable toxicity removal mechanisms, supporting the higher removal efficiency observed in the AS system. Samples from the three systems were analyzed using the yeast estrogen screen (YES) assay to evaluate estrogenic activity and by gas chromatography-mass spectrometry for detection of eight estrogenic compounds. YES test results revealed that the AS system presented the highest estrogenicity removal efficiencies, with average inlet and loads of 9.2 and 0.3 mg 17- β estradiol equivalents (E2 eq.)/d. The UASB/TF system presented minimal estrogenicity removal (average concentrations of 1.8 and 1.5 ng E2 eq./L for inlet and outlet samples, respectively), while the ST/AF system increased estrogenic activity, with average concentrations of 1.6 and 2,3 ng E2 eq./L for inlet and outlet samples, respectively, during the monitoring period. The natural hormones estrone, 17-β- estradiol, estriol and the synthetic 17-β-ethinylestradiol were sporadically detected in the three systems, while 4-octylphenol and 4-nonylphenol were rarely detected. Bisphenol A was the most frequently detected of the compounds evaluated. Hormones were detected in sediment samples downstream, but not upstream of the UASB/TF and ST/AF discharge pipes, suggesting that the treated wastewaters contributed to sediment contamination.

Page generated in 0.5001 seconds