• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação dos níveis de umidificação e aquecimento durante ventilação artificial com a estação de trabalho de anestesia Primus da Dräger com baixo fluxo de gases frescos e permutador de calor e umidade /

Castro Júnior, Jair de. January 2009 (has links)
Orientador: Jose Reinaldo Cerqueira Braz / Banca: Regina Helena Garcia Martins / Banca: Flora Margarida Barra Bisinotto / Banca: Luiz Vicente Garcia / Banca: Artur Udelsmann / Resumo: Durante anestesia geral com intubação traqueal para manutenção das vias aéreas, a umidificação e o aquecimento artificial dos gases inalados são essenciais para a prevenção de alterações na mucosa traqueobrônquica e diminuição do risco de hipotermia não intencional durante a cirurgia. A estação de trabalho de anestesia Primus (Dräger, Lübeck, Alemanha) tem placa de metal aquecida, situada na parte expiratória do circuito, para a prevenção da condensação de água no sistema respiratório. Esta placa aquecida também pode ajudar na manutenção da temperatura do gás no circuito respiratório em valores adequados. O presente estudo teve como objetivo a determinação da temperatura esofágica e da temperatura e umidade dos gases anestésicos no circuito respiratório do aparelho Primus da Dräger usando baixo fluxo de gases frescos (FGF) associado ou não ao uso do permutador de calor e umidade (PCU). Participaram do estudo trinta pacientes adultas com estado físico ASA I e II submetidas a cirurgias ginecológicas eletivas. As pacientes foram distribuídas aleatoriamente em dois grupos sob ventilação com baixo FGF de 1 L.min-1 com ou sem PCU durante anestesia geral com sistema circular respiratório com absorvedor de CO2. Todas as pacientes receberam aquecimento ativo da superfície cutânea por meio de manta térmica colocada sobre os membros inferiores. A temperatura e umidades relativa e absoluta dos Introdução e Literatura 6 gases e a temperatura esofágica foram medidas aos 15 minutos (tempo controle) após instalação do sistema de ventilação nas pacientes e, então, a cada 30 minutos até 120 minutos após o tempo controle. A temperatura e a umidade relativa e absoluta dos gases inalados no grupo com baixo FGF ao PCU apresentaram valores mais elevados comparados aos do grupo com baixo FGF sem PCU (p < 0,05). Não houve redução na temperatura... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In general anesthesia with endotracheal intubation, maintenance of airway humidity and temperature is important to prevent damage to the tracheobronchial mucosa and to risk the drop in body temperature during surgery. The anesthesia Primus's work station (Dräger, Lübeck, Germany) has a built-in hot plate coupled to heat expired gases to prevent water condensation in the breathing system, but this heating plate also may help maintaining gas temperature in the respiratory system at adequate levels. In the present study, we measured the inspired gas temperature and humidity of the anesthetic circuit in the Dräger Primus machine using low fresh gas flow with or without a heat and moisture exchanger (HME). Thirty adult ASA I and II women patients scheduled to gynaecologic surgeries were randomly assigned into two groups to received low fresh gas flow of 1 L.min-1 with or without HME in the circle anesthesia system. All patients received active skin-surface warming with a specific blanket from a warming device. Relative humidity, absolute humidity, and temperature of inspired gases and esophageal temperature were measured at 15 min and then every 30 min up to 120 min after the installation of the respiratory system. There was a significantly higher relative humidity, absolute humidity and temperatures of the inspired gases in the HME group compared to without HME group (p < 0.05). The esophageal temperature did not decrease in Introdução e Literatura 8 the group HME (p > 0.05), but decreased significantly intraoperatively in without HME group (p < 0.05). Low-flow with the breathing system of the Dräger Primus anesthesia workstation have inherent humidifying properties sufficient to reduce the risk of respiratory tract dehydration only after 90 minutes of anaesthesia. The addition of HME improves the inspiratory absolute humidity, relative humidity and temperature of the anesthetic... (Complete abstract click electronic access below) / Doutor
2

Análise numérica de condensadores do tipo arame-sobre-tubo usados em refrigeradores domésticos /

Lima, Rafael Sene de. January 2008 (has links)
Orientador: André Luiz Seixlack / Banca: Emanuel Rocha Woiski / Banca: José Roberto Simões Moreira / Resumo: Neste trabalho apresenta-se um modelo numérico para a simulação do escoamento transiente de fluidos refrigerantes ao longo de condensadores do tipo arame-sobre-tubo, comumente usados em refrigeradores domésticos que empregam o ciclo de compressão de vapor. A análise envolve o escoamento do fluido refrigerante no interior do tubo e a transferência de calor por convecção natural e radiação entre a superfície externa do tubo, as aletas em forma de arames cilíndricos e o ar externo. No interior do tubo o escoamento é considerado unidimensional e dividido em uma região monofásica de vapor superaquecido, uma região bifásica líquido-vapor e outra em que o refrigerante encontra-se no estado de líquido subresfriado. A queda de pressão no interior do tubo é também considerada. Na região bifásica o escoamento é considerado homogêneo, ou seja, são consideradas condições de equilíbrio térmico e hidrodinâmico entre as fases. Inicialmente, condições de regime permanente serão assumidas e posteriormente será analisada a resposta dinâmica do condensador às variações das condições de operação do sistema. A simulação do escoamento ao longo do condensador é obtida a partir da solução numérica das equações de conservação da massa, da quantidade de movimento e de conservação de energia. Para a parede do condensador, a equação de conservação de energia é resolvida para determinar a sua distribuição de temperatura. O método de Volumes Finitos é usado na discretização das equações governantes. O modelo permite a determinação, nos regimes permanente e transiente, das distribuições de pressão, título, temperatura do refrigerante e temperatura do tubo ao longo do condensador, em função da geometria do condensador e das condições de operação. O modelo proposto é analisado e os resultados obtidos são discutidos e comparados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work presents a numerical model to simulate the unsteady refrigerant fluid flow along wire-on-tube condensers, commonly used in vapor compression cycle based domestic refrigerators. The model considers the refrigerant flow inside the tube and the heat transfer from the outer surfaces of the wires and tubes to the surrounding air by free convection and radiation. The refrigerant flow along the condenser is divided into a vapor superheated singlephase region, a two-phase liquid-vapor flow region and a subcooled liquid region. The refrigerant pressure drop is taking into account. The homogeneous model is employed for the two-phase flow region, i.e. the hydrodynamic and thermal equilibrium between the phases are considered. Initially the steady state condition is considered and later condenser unsteady behavior is analyzed. The mass conservation, momentum and energy conservation equations for the refrigerant flow are solved in order to evaluate the distributions of mass flux, pressure and temperature of the refrigerant fluid, respectively. Also, the energy conservation equation for the tube wall is solved to determine the wall temperature distribution. The system of differential equations is solved using the Finite Volume method. The model is analyzed and the obtained results are compared with data available in the open literature. / Mestre

Page generated in 0.0408 seconds