• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Využití aditivní technologie pro návrh a výrobu prototypu oční protézy / Use of additive technology for the design and production of eye prosthesis prototype

Vocílka, Ondřej January 2019 (has links)
This diploma thesis has an aim to fabricate a prototype of esthetical prosthesis using solely Rapid Prototyping aditive technology and to explore the possibility of using commercially available biocompatible materials. In the theoretical part, a description of types of ocular prosthesis types with the focus being on esthetic ocular prosthesis. is given. The practical part of the work offers a comprehensive view on the whole process of the prototype fabrication. It provides a description of creating the 3D model by scanning, geometrical adjustments of the model, textures mapping, print optimization and the printing itself. The closing part of the thesis consists of a discussing focused on an evaluation of the fabricated prototype followed by technical-economical assesment, a proposal of next steps, and a proposal of current usage of the created method.
2

Avaliação da liberação de monômero residual, absorção de água e porosidade superficial em resinas acrílicas para prótese ocular / Evaluation of residual monomer, water sorption and porosity by acrylic resins used to eye prostheses

Oliveira, Rodrigo Elias de 07 March 2008 (has links)
A necessidade do aprimoramento das técnicas de confecção de próteses oculares que permitam satisfazer, com rapidez e excelência, a demanda de atendimento de pacientes portadores de perdas do bulbo ocular, levou ao desenvolvimento deste estudo comparativo no qual se avalia a porosidade superficial, absorção de água e liberação de monômero residual de resinas acrílicas. Foram estabelecidos quatro grupos de estudo, sendo cada grupo composto por 15 corpos de prova: Grupo 1 - resina acrílica termo polimerizável convencional / ciclo térmico convencional; Grupo 2 - resina acrílica termo polimerizável em microondas / ciclo microondas; Grupo 3 - resina acrílica termo polimerizável convencional / ciclo microondas; Grupo 4 - resina acrílica auto polimerizável com cadeia cruzada / auto polimerização. A avaliação da quantidade de monômero residual liberado foi realizada por meio de espectrofotometria, durante o período de 11 dias. A determinação da absorção de água baseou-se na diferença do peso apresentado pelos corpos de prova nas condições experimentais seco e após submersão em água deionizada por um período de 7 dias. A determinação da porosidade superficial foi calculada sob a forma de porcentagem por área de superfície analisada, empregando-se lupa estereoscópica para captação da imagem a ser processada pelo software ImageLab 2000®. Submetendo-se os dados à análise estatística ANOVA/TUKEY (p<=0,05) observou-se que a liberação de monômero residual foi significantemente maior no primeiro dia para o Grupo 1, semelhante durante todo o período para o Grupo 2, menor a partir do dia 8 para o Grupo 3 e decrescente até o dia 8 para o Grupo 4. A liberação de monômero residual foi semelhante para os Grupos 1 e 3, menor para o Grupo 2 e maior para o Grupo 4. A absorção de água foi semelhante para os quatro grupos de estudo. A maior porosidade ocorreu no Grupo 2, sendo os Grupos 1 e 3 semelhantes entre si. Concluiu-se que os ciclos térmicos de polimerização em água e em microondas não interferiram na liberação de monômero residual da resina acrílica termo polimerizável convencional. A liberação de monômero residual variou em função do tipo de resina acrílica. O tipo de resina acrílica e o ciclo de polimerização a que foram submetidas não interferiram na absorção de água. Os ciclos térmicos de polimerização em água e em microondas não interferiram na porosidade apresentada pela resina acrílica termo polimerizável convencional. A porosidade superficial variou em função do tipo de resina acrílica avaliada. / This comparative evaluation of porosity, water sorption and residual monomer presented by acrylic resins was conducted, looking for excellence and rapidity in the confection of eye prostheses. Four groups, comprising of 15 specimens each, were established and submitted to polymerization cycles: Group 1 - conventional heat polymerizing acrylic resin / conventional heat-polymerization cycle; Group 2 - microwave acrylic resin / microwave cycle; Group 3 - conventional heat polymerizing acrylic resin / microwave cycle; Group 4 - cross-linked auto-polymerizing acrylic resin / auto-polymerizing process. Residual monomer liberation was determined by spectrophotometry during 11 days period. Water sorption was calculated by weighting dried specimens and weighting after 7 days of submersion in deionized water. Superficial porosity was determined by percentage of area, in images processed by the software ImageLab 2000®. Subjecting data to ANOVA/TUKEY test (p<=0,05) it was observed that residual monomer liberation was higher in the first day for Group 1, similar during all the period for Group 2, lower after day 8 for Group 3 and decreasing until day 8 for Group 4. Residual monomer liberation was similar to Groups 1 and 3, lower for Group 2 and higher for Group 4. Water sorption was similar to all groups. Group 2 displayed more superficial porosity, and Group 1 and 3 were similar regarding this test. In conclusion, conventional polymerization and microwave processes did not interfere in residual monomer liberation of conventional acrylic resin. The residual monomer liberation varied according the type of acrylic resin. Microwave cycle provided similar or smaller residual monomer liberation. The type of acrylic resin and the polymerization cycle utilized did not modify water sorption. The conventional heat polymerizing cycle and microwave cycle did not interfere in superficial porosity of conventional heat polymerizing acrylic resin. The superficial porosity varied according to the acrylic resin.
3

Avaliação da liberação de monômero residual, absorção de água e porosidade superficial em resinas acrílicas para prótese ocular / Evaluation of residual monomer, water sorption and porosity by acrylic resins used to eye prostheses

Rodrigo Elias de Oliveira 07 March 2008 (has links)
A necessidade do aprimoramento das técnicas de confecção de próteses oculares que permitam satisfazer, com rapidez e excelência, a demanda de atendimento de pacientes portadores de perdas do bulbo ocular, levou ao desenvolvimento deste estudo comparativo no qual se avalia a porosidade superficial, absorção de água e liberação de monômero residual de resinas acrílicas. Foram estabelecidos quatro grupos de estudo, sendo cada grupo composto por 15 corpos de prova: Grupo 1 - resina acrílica termo polimerizável convencional / ciclo térmico convencional; Grupo 2 - resina acrílica termo polimerizável em microondas / ciclo microondas; Grupo 3 - resina acrílica termo polimerizável convencional / ciclo microondas; Grupo 4 - resina acrílica auto polimerizável com cadeia cruzada / auto polimerização. A avaliação da quantidade de monômero residual liberado foi realizada por meio de espectrofotometria, durante o período de 11 dias. A determinação da absorção de água baseou-se na diferença do peso apresentado pelos corpos de prova nas condições experimentais seco e após submersão em água deionizada por um período de 7 dias. A determinação da porosidade superficial foi calculada sob a forma de porcentagem por área de superfície analisada, empregando-se lupa estereoscópica para captação da imagem a ser processada pelo software ImageLab 2000®. Submetendo-se os dados à análise estatística ANOVA/TUKEY (p<=0,05) observou-se que a liberação de monômero residual foi significantemente maior no primeiro dia para o Grupo 1, semelhante durante todo o período para o Grupo 2, menor a partir do dia 8 para o Grupo 3 e decrescente até o dia 8 para o Grupo 4. A liberação de monômero residual foi semelhante para os Grupos 1 e 3, menor para o Grupo 2 e maior para o Grupo 4. A absorção de água foi semelhante para os quatro grupos de estudo. A maior porosidade ocorreu no Grupo 2, sendo os Grupos 1 e 3 semelhantes entre si. Concluiu-se que os ciclos térmicos de polimerização em água e em microondas não interferiram na liberação de monômero residual da resina acrílica termo polimerizável convencional. A liberação de monômero residual variou em função do tipo de resina acrílica. O tipo de resina acrílica e o ciclo de polimerização a que foram submetidas não interferiram na absorção de água. Os ciclos térmicos de polimerização em água e em microondas não interferiram na porosidade apresentada pela resina acrílica termo polimerizável convencional. A porosidade superficial variou em função do tipo de resina acrílica avaliada. / This comparative evaluation of porosity, water sorption and residual monomer presented by acrylic resins was conducted, looking for excellence and rapidity in the confection of eye prostheses. Four groups, comprising of 15 specimens each, were established and submitted to polymerization cycles: Group 1 - conventional heat polymerizing acrylic resin / conventional heat-polymerization cycle; Group 2 - microwave acrylic resin / microwave cycle; Group 3 - conventional heat polymerizing acrylic resin / microwave cycle; Group 4 - cross-linked auto-polymerizing acrylic resin / auto-polymerizing process. Residual monomer liberation was determined by spectrophotometry during 11 days period. Water sorption was calculated by weighting dried specimens and weighting after 7 days of submersion in deionized water. Superficial porosity was determined by percentage of area, in images processed by the software ImageLab 2000®. Subjecting data to ANOVA/TUKEY test (p<=0,05) it was observed that residual monomer liberation was higher in the first day for Group 1, similar during all the period for Group 2, lower after day 8 for Group 3 and decreasing until day 8 for Group 4. Residual monomer liberation was similar to Groups 1 and 3, lower for Group 2 and higher for Group 4. Water sorption was similar to all groups. Group 2 displayed more superficial porosity, and Group 1 and 3 were similar regarding this test. In conclusion, conventional polymerization and microwave processes did not interfere in residual monomer liberation of conventional acrylic resin. The residual monomer liberation varied according the type of acrylic resin. Microwave cycle provided similar or smaller residual monomer liberation. The type of acrylic resin and the polymerization cycle utilized did not modify water sorption. The conventional heat polymerizing cycle and microwave cycle did not interfere in superficial porosity of conventional heat polymerizing acrylic resin. The superficial porosity varied according to the acrylic resin.

Page generated in 0.0937 seconds