• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 58
  • 3
  • 1
  • Tagged with
  • 62
  • 62
  • 40
  • 37
  • 20
  • 17
  • 13
  • 13
  • 11
  • 11
  • 11
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

\"Avaliação dos efeitos da alteração dimensional de resinas para base de próteses totais submetidas a diferentes técnicas de processamento avaliados ao nível condilar\" / Evaluation of the dimensional changes of acrylic resin for complete denture submitted to different types of processing evaluated to the level of the condyle

Yamaguchi, Flavio Jun 18 September 2006 (has links)
O objetivo deste trabalho foi avaliar as alterações dimensionais de resinas acrílicas submetidas a diferentes tipos de processamento avaliados ao nível condilar. As condições experimentais foram introduzidas em três etapas. Na etapa A, as resinas acrílicas (Clássico, Ondacryl, Acron MC, Lucitone e QC-20) foram incluídas em muflas contendo muralha de gesso, prensadas na fase plástica e submetidas a cinco ciclos de acrilização. Na etapa B, as resinas acrílicas utilizadas foram a QC-20 e a Lucitone, utilizando três tipos de muralha (gesso, silicone (ZETALABOR) e filme de silicone (VIPISIL)), e duas fases de reação química da resina acrílica na prensagem (fluida e plástica). Na etapa C, foi utilizada a resina Acron MC com dois ciclos de polimerização (90W por treze minutos e 500W por três minutos) variando-se, ainda, o tipo de muralha como na etapa B. Para o estudo, foram confeccionadas 5 próteses totais para cada grupo. Ao final, obtiveram-se 23 grupos totalizando 115 próteses totais superiores. Mediu-se a variação posicional do ramo superior do articulador TT antes e após os processamentos, tendo por base a orientação oclusal da máxima intercuspidação. Tal variação foi registrada através de gesso tipo IV vertido em espaço ao redor das esferas condilares, previamente providos por meio de espaçadores utilizados antes do processamento. Foram medidas três distâncias em cada esfera condilar (superoinferior, anteroposterior e mediolateral) resultando em 690 medidas que variaram de 0 a 3 mm, com média de 0,79 mm e desvio padrão de 0,59 mm. Ocorreu alteração em 687 medidas, sendo que houve diferença entre os grupos, estatisticamente significante, principalmente para a distância anteroposterior do lado esquerdo, na variável resina. Conclui-se que, as alterações dimensionais de resinas alteraram as posições das esferas condilares. / The objective of this study is to evaluate the dimensional acrylic resin alterations submitted to different types of processing evaluated to the level of the condyle. The experimental conditions were introduced in three stages. In stage A , the acrylic resins (Classic, Ondacryl, Acron MC, Lucitone and QC-20) were enclosed in flasks contend plaster wall, pressed in the plastic phase and submitted to five cycles of acrylization. In stage B, the QC-20 and the Lucitone were used with three types of wall (plaster, silicone (ZETALABOR) and silicone film (VIPISIL)), and with two phases of chemical reaction of the acrylic resin (fluid and plastic). In stage C, the resin Acron MC with two cycles of polymerization was used (90W for thirteen minutes and 500W for three minutes) by changing the type of wall as in stage B. For the study, 5 complete dentures for each group were made. At the end of the experiment, 23 groups were obtained, totalizing 115 superior complete dentures. Positional variation of the upper member of the articulator T.T.was measured before and after the processing, based on the maximum intercuspidation orientation. Such variation was registered by using plaster type IV shed in the space around of the condyle spheres, previously provided by means of spacers used before the processing. Three distances in each condyle sphere were measured (superoinferior, anteroposterior and mediolateral) resulting in 690 measures that varied from 0 to 3 mm, with average of 0,79 mm and shunting line standard of 0,59 mm. An alteration in 687 measures occurred and there was difference between the groups statistically significant, mainly for the anteroposterior distance on the left side. The conclusion was that the dimensional resin alterations modified the positions of the condyle spheres
2

Estudo da transmissão e distribuição de tensões aplicadas à resina acrílica convencional e acrescida de fibras através do método fotoelástico / Study of tension transmission and distribution applied upon acrylic conventional resin and strengthened by fibers through photoelastic method

Oliveira, Andréa Gomes de 08 August 2007 (has links)
A resina acrílica encontra-se entre os materiais mais utilizados na odontologia. Apesar de suas qualidades, o polimetilmetacrilato ainda mostra-se um material com resistência comprometida. Para tanto, diversos reforços têm sido propostos na literatura e entre eles encontram-se as fibras de vidro e aramida. Apesar de acrescerem na resistência da matriz acrílica pouco se sabe sobre como os esforços aplicados sobre a resina reforçada por fibras são transmitidos e distribuídos às áreas de sustentação, o que motivou a realização deste estudo. Foram confeccionados dez corpos-de-prova em resina acrílica termopolimerizável divididos em cinco grupos segundo o reforço utilizado: fibras de vidro filamentares tratadas por imersão no monômero acrílico (Grupo F), fibras de vidro em malha submetidas ao mesmo tratamento (Grupo M), fibras de vidro trançadas com aramida e tratadas por imersão na mistura monômero/polímero (Grupo H) e fibras de vidro trançadas com aramida e tratadas por silanização (Grupo HS). Como grupo controle (C) foram utilizadas amostras de resina acrílica termicamente ativada sem a associação de fibras de reforço. Após a adaptação dos corpos-de-prova à matriz fotoelástica os mesmos foram submetidos a ensaio de flexão através da Máquina Universal de Ensaios (EMIC-modelo DL 2000, S. J. dos Pinhais, PR, Brasil) acoplada ao Polariscópio Circular (Desenvolvido na Faculdade de Engenharia Mecânica - UFU, Uberlândia, MG, Brasil). Os resultados mostraram valores para a Energia de Distorção, em Kgf/mm2, de 223,124 para o grupo F; de 218,710 para o grupo H; 217,692 para o grupo M; 215,810 para o grupo HS e de 210,122 para o grupo C. Também foi observado que a energia de distorção apresentou distribuição homogeneamente crescente em todos os grupos estudados. Concluímos que a associação de fibras à resina acrílica gerou aumento da energia acumulada na área de sustentação protética sendo que os maiores valores foram observados para o grupo de fibras de vidro filamentares. Observamos também que a silanização da fibra híbrida contribuiu para uma menor transmissão de tensão à matriz fotoelástica. / Acrylic resin is found among the most used materials in dentistry. Despite its qualities, the polymetilmetacrylate yet shows itself as a material with questionable resistance. Therefore, lots of reinforcements have been proposed in literature and among them we find glass fibers and aramid. Although they add to the resistance of the acrylic matrix, little is known about how the efforts applied upon the resin strengthened by the fibers are transmitted and distributed over the sustaining areas, which motivated the course of this study. Ten specimens made of termcured acrylic resin were created and divided into five groups according to the reinforcement used: roving glass fibers treated by immersion in the acrylic monomer (Group F), mesh glass fibers given the same treatment above (Group M), glass fibers braided with aramid and treated by immersion in the blending momer/polimer (Group H) and glass fibers braided with aramid and treated by signalization (Group HS). As control group (C) were used samples of acrylic resin termically activated without the addition of fibers. After adapting the specimens to the photoelastic matrix, the former were submitted to flexural tests through the Universal Machine of Rehearsal (EMIC-model DL 2000, S. J. Dos Pinhais, PR, Brazil) joint to the Circular Polariscope ( developed in the Mechanical Engineering College ? UFU, Uberlândia, MG, Brazil. The results show values to the Distortion Energy, in Kgf /mm2, of 223,124 for group F; 218,710 for group H; 217,692 for group M; 215,810 for group HS and 210,122 for group C. It was also observed that the distortion energy presented homogeneous growing distribution in al the groups studied. We conclude that the association of fibers to the acrylic resin generated an increase of the energy accumulated in the area of prosthetic support, thus the highest values were observed in the group with roving glass fibers. We noticed that the silanization of the hibrid fiber contributed to a smaller tension transmission to the photoelastic matrix.
3

Analysis of microbial contamination of device acrylic manufactured in dental laboratories / AnÃlise da contaminaÃÃo microbiana de dispositivos acrÃlicos confeccionados em laboratÃrios de prÃtese dentÃria

Guilherme de Alencar TemÃteo 27 February 2014 (has links)
Universidade Federal do Cearà / A possÃvel presenÃa de microorganismos potencialmente patogÃnicos em prÃteses dentÃrias recÃm-chegadas dos laboratÃrios protÃticos deve ser considerada. Este estudo avaliou o nÃvel de contaminaÃÃo bacteriana e fÃngica de espÃcimes de resina acrÃlica confeccionados em 14 laboratÃrios de prÃtese dentÃria, inscritos no Conselho Regional de Odontologia do CearÃ, na cidade de Fortaleza. Cada laboratÃrio foi solicitado a confeccionar 10 espÃcimes de resina acrÃlica, a partir de modelos padronizados de silicona de adiÃÃo estÃreis, desconhecendo os objetivos da pesquisa. Os espÃcimes recebidos dos laboratÃrios foram colocados em tubos individuais contendo BHI caldo e incubados a 37ÂC por 48 horas e, em seguida, removidos, lavados, colocados em soluÃÃo salina estÃril e agitados para desprendimento microbiano. A suspensÃo obtida foi diluÃda em 1:100, 1:1000 e semeada em placas com Ãgar Sangue, Sabouraud Dextrose Ãgar e HICrome UTI ÃgarÂ, para incubaÃÃo por 48 horas a 37ÂC. Foi obtido o nÃmero de unidades formadoras de colÃnias (UFC) bacterianas e fÃngicas viÃveis, alÃm da identificaÃÃo e quantificaÃÃo de algumas espÃcies de bactÃrias, comparando-se os laboratÃrios por meio dos testes de Kruskall-Wallis e Dunn (&#945;=0.05). Houve contaminaÃÃo advinda de todos os laboratÃrios analizados, com uma contagem de UFC mÃdia de 101438 de bactÃrias e 71047 de fungos. Pseudomonas spp foi o microorganismo a mais prevalente identificado (p<0,05). Foi concluido que existe risco de contaminaÃÃo por bactÃrias potencialmente patogÃnicas e fungos em dispositivos protÃticos recÃm chegados dos laboratÃrios. / The possible presence of potentially pathogenic microorganisms in denture newly arrived from prosthetic laboratories should be considered. This study evaluated the level of bacterial and fungal contamination of specimens of acrylic resin made in 14 dental laboratories registered with the Regional Council of Dentistry of CearÃ, Fortaleza. Each laboratory was asked to fabricate 10 specimens of acrylic resin, from standard models of sterile silicone addition, unaware of the research objectives. Specimens received from laboratories were placed in individual tubes containing BHI broth, incubated at 37ÂC for 48 hours and then removed, washed and placed in sterile saline and stirred for microbial detachment. The suspension obtained was diluted (1:100, 1:1000) and plated on blood agar plates, and Sabouraud Dextrose Agar and Agar HiCrome ICU by incubation for 48 hours at 37ÂC. The number of colony forming units (CFU) bacterial and fungal viable was obtained, besides the identification and quantification of some species of bacteria, comparing the laboratory by means of the Kruskal-Wallis and Dunn (&#945; = 0.05) tests. There was contamination originating from all laboratories analyzed, with a mean CFU counts of 101438 bacteria and 71047 fungi. Pseudomonas spp was the most prevalent microorganism identified (p < 0.05). It was concluded that there is a risk of contamination with potentially pathogenic bacteria and fungi in prosthetic devices newly arrived from dental laboratories.
4

Estudo da transmissão e distribuição de tensões aplicadas à resina acrílica convencional e acrescida de fibras através do método fotoelástico / Study of tension transmission and distribution applied upon acrylic conventional resin and strengthened by fibers through photoelastic method

Andréa Gomes de Oliveira 08 August 2007 (has links)
A resina acrílica encontra-se entre os materiais mais utilizados na odontologia. Apesar de suas qualidades, o polimetilmetacrilato ainda mostra-se um material com resistência comprometida. Para tanto, diversos reforços têm sido propostos na literatura e entre eles encontram-se as fibras de vidro e aramida. Apesar de acrescerem na resistência da matriz acrílica pouco se sabe sobre como os esforços aplicados sobre a resina reforçada por fibras são transmitidos e distribuídos às áreas de sustentação, o que motivou a realização deste estudo. Foram confeccionados dez corpos-de-prova em resina acrílica termopolimerizável divididos em cinco grupos segundo o reforço utilizado: fibras de vidro filamentares tratadas por imersão no monômero acrílico (Grupo F), fibras de vidro em malha submetidas ao mesmo tratamento (Grupo M), fibras de vidro trançadas com aramida e tratadas por imersão na mistura monômero/polímero (Grupo H) e fibras de vidro trançadas com aramida e tratadas por silanização (Grupo HS). Como grupo controle (C) foram utilizadas amostras de resina acrílica termicamente ativada sem a associação de fibras de reforço. Após a adaptação dos corpos-de-prova à matriz fotoelástica os mesmos foram submetidos a ensaio de flexão através da Máquina Universal de Ensaios (EMIC-modelo DL 2000, S. J. dos Pinhais, PR, Brasil) acoplada ao Polariscópio Circular (Desenvolvido na Faculdade de Engenharia Mecânica - UFU, Uberlândia, MG, Brasil). Os resultados mostraram valores para a Energia de Distorção, em Kgf/mm2, de 223,124 para o grupo F; de 218,710 para o grupo H; 217,692 para o grupo M; 215,810 para o grupo HS e de 210,122 para o grupo C. Também foi observado que a energia de distorção apresentou distribuição homogeneamente crescente em todos os grupos estudados. Concluímos que a associação de fibras à resina acrílica gerou aumento da energia acumulada na área de sustentação protética sendo que os maiores valores foram observados para o grupo de fibras de vidro filamentares. Observamos também que a silanização da fibra híbrida contribuiu para uma menor transmissão de tensão à matriz fotoelástica. / Acrylic resin is found among the most used materials in dentistry. Despite its qualities, the polymetilmetacrylate yet shows itself as a material with questionable resistance. Therefore, lots of reinforcements have been proposed in literature and among them we find glass fibers and aramid. Although they add to the resistance of the acrylic matrix, little is known about how the efforts applied upon the resin strengthened by the fibers are transmitted and distributed over the sustaining areas, which motivated the course of this study. Ten specimens made of termcured acrylic resin were created and divided into five groups according to the reinforcement used: roving glass fibers treated by immersion in the acrylic monomer (Group F), mesh glass fibers given the same treatment above (Group M), glass fibers braided with aramid and treated by immersion in the blending momer/polimer (Group H) and glass fibers braided with aramid and treated by signalization (Group HS). As control group (C) were used samples of acrylic resin termically activated without the addition of fibers. After adapting the specimens to the photoelastic matrix, the former were submitted to flexural tests through the Universal Machine of Rehearsal (EMIC-model DL 2000, S. J. Dos Pinhais, PR, Brazil) joint to the Circular Polariscope ( developed in the Mechanical Engineering College ? UFU, Uberlândia, MG, Brazil. The results show values to the Distortion Energy, in Kgf /mm2, of 223,124 for group F; 218,710 for group H; 217,692 for group M; 215,810 for group HS and 210,122 for group C. It was also observed that the distortion energy presented homogeneous growing distribution in al the groups studied. We conclude that the association of fibers to the acrylic resin generated an increase of the energy accumulated in the area of prosthetic support, thus the highest values were observed in the group with roving glass fibers. We noticed that the silanization of the hibrid fiber contributed to a smaller tension transmission to the photoelastic matrix.
5

Biocompatibilidade de resinas acrílicas para base e reembasamento de próteses após períodos de imersão em soluções desinfetantes: análise do metabolismo celular / Biocompatibility of denture base and reline acrylic resins after immersion in disinfectant solutions periods: cellular metabolism analysis

Masetti, Paula [UNESP] 05 April 2016 (has links)
Submitted by PAULA MASETTI null (paulamasetti@foar.unesp.br) on 2016-05-19T20:53:43Z No. of bitstreams: 1 Tese Corrigida Paula.pdf: 1034060 bytes, checksum: f68e39b40f15f384b00f2c850a864a26 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-05-23T18:59:36Z (GMT) No. of bitstreams: 1 masetti_p_me_arafo.pdf: 1034060 bytes, checksum: f68e39b40f15f384b00f2c850a864a26 (MD5) / Made available in DSpace on 2016-05-23T18:59:36Z (GMT). No. of bitstreams: 1 masetti_p_me_arafo.pdf: 1034060 bytes, checksum: f68e39b40f15f384b00f2c850a864a26 (MD5) Previous issue date: 2016-04-05 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o efeito cumulativo das soluções desinfetantes na citotoxicidade de resinas acrílicas para base (Vipi Wave) e reembasamento (Tokuyama Rebase II) de próteses. Corpos de prova com 14 mm de diâmetro e 1,2 mm de espessura foram distribuídos em grupos (n=3) de acordo com o tipo de solução: água destilada, digluconato de clorexidina a 2%, perborato de sódio a 3,8%, hipoclorito de sódio a 0,5% e vinagre de maçã, e de acordo com o tempo de imersão: 0, 1, 3 e 6 meses. Os corpos de prova, tanto de base quanto de reembasamento, ficaram 8 horas imersos nas soluções e 16 horas em água destilada, simulando desinfecção noturna das próteses. As soluções foram trocadas diariamente. Após os diferentes períodos de imersão, as amostras foram colocadas em meio de cultura por 24 horas para obtenção de extratos para análise da citotoxicidade sobre queratinócitos humanos (HaCaT: 0341). O metabolismo celular foi avaliado pelo teste Alamar Blue ®. Empregou-se análise de variância (ANOVA) e teste de Tukey, com significância de 5%. Os resultados demonstraram que o tipo de resina não teve influência sobre o metabolismo celular. Além disso, a imersão das amostras de resina acrílica para base e reembasamento de próteses em água destilada, perborato de sódio a 3,8% e hipoclorito de sódio a 0,5% não influenciou o metabolismo celular dos queratinócitos, independentemente do tempo de imersão. Os extratos obtidos a partir da imersão das amostras em digluconato de clorexidina a 2% ou em vinagre de maçã durante 3 e 6 meses foram considerados intensamente citotóxicos. Pôde-se concluir que o digluconato de clorexidina a 2% e o vinagre de maça aumentaram citotoxicidade de resinas acrílicas para base e reembasamento de próteses. / The objective of this study was to evaluate the cumulative effect of disinfectant solutions in cytotoxicity base acrylic resins (Vipi Wave) and reline (Tokuyama Rebase II) of dentures. Samples of 14 mm diameter and 1.2 mm thick were distributed in groups (n = 3) according to the type of disinfectant solution: distilled water, 2% chlorhexidine digluconate, 3.8 % sodium perborate, 0.5% sodium hypochlorite and apple vinegar and in accordance with the immersion time: 0, 1, 3 and 6 months. The samples of both base and of reline, eight hours were immersed in solutions and 16 hours in distilled water, simulating night disinfection of prostheses. The solutions were changed daily. After different periods of immersion, the samples were placed in culture medium for 24 hours to obtain extracts for analysis of cytotoxicity on human keratinocyte (HaCaT: 0341). The cellular metabolism was assessed by Alamar Blue ® test. It used analysis of variance (ANOVA) and Tukey test, with 5% significance. The results demonstrated that the resin type had no influence on cellular metabolism. Furthermore, the immersion of the samples in acrylic resin base and reline dentures in distilled water, 3.8% sodium perborate and 0.5% sodium hypochlorite did not influence the cellular metabolism of keratinocytes, regardless of the time of immersion. The extracts obtained from immersing the samples 2% chlorhexidine digluconate or apple vinegar for 3 and 6 months were considered strongly cytotoxic. It was concluded that chlorhexidine digluconate 2% and apple vinegar increased cytotoxicity of denture base and reline acrylic resins.
6

Influência de imersões em vinagre sobre a rugosidade e a dureza de uma resina acrílica de termoativação / Influence of vinegar immersions at surface roughness and microhardness of one thermo cured acrylic resin

Jiménez Pereira, Cláudia January 2014 (has links)
Diversas substâncias químicas têm sido utilizadas no processo de desinfecção e higiene de dispositivos de resina acrílica, no entanto, muitas destas substâncias são utilizadas de forma empírica. Sendo assim, o objetivo do presente estudo foi avaliar a influência da imersão em vinagre, hipoclorito de sódio e peróxido de hidrogênio na rugosidade e na dureza de uma resina acrílica de termoativação Meliodent® Heat Cure (Heraeus Kultzer, Alemanha). Foram confeccionados 130 corpos de prova de resina acrílica e estes foram aleatoriamente divididos em 13 grupos (n=10). O grupo controle permaneceu a seco, sem imersão. Os grupos teste foram submetidos à imersão em vinagre, hipoclorito de sódio 1%, peróxido de hidrogênio 10V e água destilada por diferentes tempos (30h, 150h ou 300h). As soluções foram protegidas da luz e trocadas a cada período de 24 horas. Após o período de imersão foram avaliadas a microdureza Knoop e a rugosidade Ra da resina acrílica. A microdureza Knoop dos corpos foi obtida com o microdurômetro automático HMV-2 (Shimadzu, Japão) sendo utilizada a medida de cinco mensurações em cada corpo de prova com uma carga de 25g por 10 segundos. A rugosidade Ra foi determinada pela media de cinco leituras realizadas em cada corpo de prova, utilizando-se um Rugosímetro SJ-201 (Mitutoyo, Japão). Os resultados mostraram que houve diferença estatisticamente significativa na microdureza da resina acrílica de termopolimerização após a imersão durante 30h, 150h e 300 h em vinagre, hipoclorito de sódio 1%, peróxido de hidrogênio 10V e água destilada, quando comparado com o grupo controle, que permaneceu a seco. Os resultados da rugosidade não mostraram diferença estatisticamente significativa após a imersão durante 30h, 150h e 300h em vinagre e água destilada quando comparados com o grupo controle, sem imersão. Com base no desenho experimental e nos resultados do presente estudo é possível concluir que o vinagre pode se tornar uma opção para desinfecção caseira de dispositivos de resina acrílica. / Several substances have been used for the disinfection and hygiene of acrylic resin devices, however, many of these substances are used empirically. Thus, the aim of this study was to evaluate the influence of immersion in vinegar, sodium hypochlorite and hydrogen peroxide on the surface roughness and hardness of thermo-cured acrylic resin Meliodent® Heat Cure (Heraeus Kultzer, Germany). 130 specimens of acrylic resin were produced and randomly divided into 13 groups (n = 10). The control group remained dry without immersion. The test groups were immersed in vinegar, 1% sodium hypochlorite, hydrogen peroxide 10V and distilled water during different times (30h, 150h and 300h). The solutions were protected from light and changed every 24 hours. After the immersion period, Knoop hardness and surface roughness of the acrylic resin were evaluated. The Knoop hardness of the specimens were obtained through an automatic microhardness tester HMV-2 (Shimadzu, Japan) with five measurements on each specimen with a load of 25g for 10 seconds. The roughness was determined by five readings on each specimen using a Surface Roughness Tester SJ-201 (Mitutoyo, Japan). The results showed a statistically significant difference in microhardness after immersion for 30h, 150h and 300h in vinegar, 1% sodium hypochlorite, hydrogen peroxide and distilled water 10V, compared with the control group. The results of roughness showed no statistically significant difference after immersion for 30h, 150h and 300h in vinegar and distilled water when compared with the control group. Based on the experimental design and results of this study it can be concluded that vinegar can eventually become an option for homemade disinfecting apparatus of acrylic resin.
7

Síntese, caracterização e atividade antimicrobiana de nanofibras de polietilmetacrilato / nistatina produzidas por eletrofiação / Synthesis, characterization and antimicrobial properties of nanofiber polymethylmethacrylate / nystatin produced by electrospinning

Santos, Jessica Dias [UNESP] 19 January 2017 (has links)
Submitted by JÉSSICA DIAS SANTOS (jediassantos@gmail.com) on 2017-01-30T14:38:16Z No. of bitstreams: 1 disseta-jessica.pdf: 3763757 bytes, checksum: 397b3e007401ec2c427cd05e78053ab7 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-02-02T19:38:09Z (GMT) No. of bitstreams: 1 santos_jd_me_sjc.pdf: 3763757 bytes, checksum: 397b3e007401ec2c427cd05e78053ab7 (MD5) / Made available in DSpace on 2017-02-02T19:38:09Z (GMT). No. of bitstreams: 1 santos_jd_me_sjc.pdf: 3763757 bytes, checksum: 397b3e007401ec2c427cd05e78053ab7 (MD5) Previous issue date: 2017-01-19 / O objetivo desse estudo foi sintetizar mantas não tecidas de nanofibras (NFs) de Polietilmetacrilato (PEMA) com adição de nistatina (NYS) e avaliar a atividade antimicrobiana nas resinas reembasadoras rígidas e macias. Realizou- se o teste microbiológico da CIM de NYS para a inativação da C. albicans. NFs foram sintetizadas pela técnica da eletrofiação, utilizando-se solução de PEMA puro e NYS e PEMA. Para a síntese das NFs de PEMA, foi produzida uma solução de PEMA dissolvido em Dimetilformamida (DMF) e 1,1,2,2 Tetracloroetano (TCE), logo após foram adicionadas duas concentrações de NYS (10 e 20 mg/ml) obtidas do teste CIM. As amostras foram analisadas em Microscopia Eletrônica de Varredura (MEV), Análise de molhabilidade, Análise de Difratometria de Raios-X (DRX) e Espectroscopia de Infravermelho por Transformada de Fourier (FTIR). Após a análise em MEV foi realizada a média dos diâmetros das fibras com Software ImageJ. As atividades antimicrobianas foram avaliadas por meio do teste de difusão em ágar. As NFs de PEMA apresentaram diâmetro menor, o padrão NF/PEMA apresentou 0,42µm enquanto que a NF/20 1,14 µm e a NF/10 foi de 0,87 µm. As fibras foram consideradas hidrofóbicas por meio da análise de molhabilidade. O DRX e o FTIR comprovaram a presença de PEMA e sugeriram a presença de NYS. O teste de difusão em ágar demonstrou que as fibras não conseguiram inibir a proliferação de C. albicans. / The objective of the study was to synthesize nanofibers (NFs) of Polyethylmethacrylate (PEMA) with addition of Nystatin (NYS) and to evaluate an antimicrobial activity in rigid and soft resins. Microbiological testing of NYS MIC for inactivation of C. albicans was performed. NFs were synthesized using the electrochemical technique using pure PEMA and NYS and PEMA solutions. For a synthesis of PEMA NFs, a solution of PEMA dissolved in Dimethylformamide (DMF) and 1,1,2,2 Tetrachloroethane (TCE) was produced, following doses of NYS concentrations (10 and 20 mg / ml) obtained from the CIM. As samples were analyzed in Scanning Electron Microscopy (SEM), Goniometer, X-ray Diffraction Analysis (XRD) and Fourier Transform Infrared Spectroscopy (FTIR). After an SEM analysis, a mean of the fiber diameters was performed with ImageJ Software. The antimicrobial activities were evaluated by means of the agar diffusion test. As the PEMA NFs presented smaller diameter, the NF / PEMA standard showed 0.42 μm whereas NF / 20 1.14 μm and the NF / 10 was 0.87μm. The fibers were considered hydrophobic by means of the wettability analysis. The DRX and the FTIR proved a presence of PEMA and suggested a presence of NYS. The diffusion test on agar demonstrated that as fibers failed to inhibit a proliferation of C. albicans.
8

Biocompatibilidade de resinas acrílicas para base e reembasamento de próteses após períodos de imersão em soluções desinfetantes : análise do metabolismo celular /

Masetti, Paula. January 2016 (has links)
Orientador: Janaina Habib Jorge / Banca: Ana Carolina Pero Vizoto / Banca: Claudia Helena Lovato da Silva / Resumo: O objetivo deste estudo foi avaliar o efeito cumulativo das soluções desinfetantes na citotoxicidade de resinas acrílicas para base (Vipi Wave) e reembasamento (Tokuyama Rebase II) de próteses. Corpos de prova com 14 mm de diâmetro e 1,2 mm de espessura foram distribuídos em grupos (n=3) de acordo com o tipo de solução: água destilada, digluconato de clorexidina a 2%, perborato de sódio a 3,8%, hipoclorito de sódio a 0,5% e vinagre de maçã, e de acordo com o tempo de imersão: 0, 1, 3 e 6 meses. Os corpos de prova, tanto de base quanto de reembasamento, ficaram 8 horas imersos nas soluções e 16 horas em água destilada, simulando desinfecção noturna das próteses. As soluções foram trocadas diariamente. Após os diferentes períodos de imersão, as amostras foram colocadas em meio de cultura por 24 horas para obtenção de extratos para análise da citotoxicidade sobre queratinócitos humanos (HaCaT: 0341). O metabolismo celular foi avaliado pelo teste Alamar Blue ®. Empregou-se análise de variância (ANOVA) e teste de Tukey, com significância de 5%. Os resultados demonstraram que o tipo de resina não teve influência sobre o metabolismo celular. Além disso, a imersão das amostras de resina acrílica para base e reembasamento de próteses em água destilada, perborato de sódio a 3,8% e hipoclorito de sódio a 0,5% não influenciou o metabolismo celular dos queratinócitos, independentemente do tempo de imersão. Os extratos obtidos a partir da imersão das amostras em digluconato de clorexidina ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to evaluate the cumulative effect of disinfectant solutions in cytotoxicity base acrylic resins (Vipi Wave) and reline (Tokuyama Rebase II) of dentures. Samples of 14 mm diameter and 1.2 mm thick were distributed in groups (n = 3) according to the type of disinfectant solution: distilled water, 2% chlorhexidine digluconate, 3.8 % sodium perborate, 0.5% sodium hypochlorite and apple vinegar and in accordance with the immersion time: 0, 1, 3 and 6 months. The samples of both base and of reline, eight hours were immersed in solutions and 16 hours in distilled water, simulating night disinfection of prostheses. The solutions were changed daily. After different periods of immersion, the samples were placed in culture medium for 24 hours to obtain extracts for analysis of cytotoxicity on human keratinocyte (HaCaT: 0341). The cellular metabolism was assessed by Alamar Blue ® test. It used analysis of variance (ANOVA) and Tukey test, with 5% significance. The results demonstrated that the resin type had no influence on cellular metabolism. Furthermore, the immersion of the samples in acrylic resin base and reline dentures in distilled water, 3.8% sodium perborate and 0.5% sodium hypochlorite did not influence the cellular metabolism of keratinocytes, regardless of the time of immersion. The extracts obtained from immersing the samples 2% chlorhexidine digluconate or apple vinegar for 3 and 6 months were considered strongly cytotoxic. It was concluded t... (Complete abstract click electronic access below) / Mestre
9

Influência de imersões em vinagre sobre a rugosidade e a dureza de uma resina acrílica de termoativação / Influence of vinegar immersions at surface roughness and microhardness of one thermo cured acrylic resin

Jiménez Pereira, Cláudia January 2014 (has links)
Diversas substâncias químicas têm sido utilizadas no processo de desinfecção e higiene de dispositivos de resina acrílica, no entanto, muitas destas substâncias são utilizadas de forma empírica. Sendo assim, o objetivo do presente estudo foi avaliar a influência da imersão em vinagre, hipoclorito de sódio e peróxido de hidrogênio na rugosidade e na dureza de uma resina acrílica de termoativação Meliodent® Heat Cure (Heraeus Kultzer, Alemanha). Foram confeccionados 130 corpos de prova de resina acrílica e estes foram aleatoriamente divididos em 13 grupos (n=10). O grupo controle permaneceu a seco, sem imersão. Os grupos teste foram submetidos à imersão em vinagre, hipoclorito de sódio 1%, peróxido de hidrogênio 10V e água destilada por diferentes tempos (30h, 150h ou 300h). As soluções foram protegidas da luz e trocadas a cada período de 24 horas. Após o período de imersão foram avaliadas a microdureza Knoop e a rugosidade Ra da resina acrílica. A microdureza Knoop dos corpos foi obtida com o microdurômetro automático HMV-2 (Shimadzu, Japão) sendo utilizada a medida de cinco mensurações em cada corpo de prova com uma carga de 25g por 10 segundos. A rugosidade Ra foi determinada pela media de cinco leituras realizadas em cada corpo de prova, utilizando-se um Rugosímetro SJ-201 (Mitutoyo, Japão). Os resultados mostraram que houve diferença estatisticamente significativa na microdureza da resina acrílica de termopolimerização após a imersão durante 30h, 150h e 300 h em vinagre, hipoclorito de sódio 1%, peróxido de hidrogênio 10V e água destilada, quando comparado com o grupo controle, que permaneceu a seco. Os resultados da rugosidade não mostraram diferença estatisticamente significativa após a imersão durante 30h, 150h e 300h em vinagre e água destilada quando comparados com o grupo controle, sem imersão. Com base no desenho experimental e nos resultados do presente estudo é possível concluir que o vinagre pode se tornar uma opção para desinfecção caseira de dispositivos de resina acrílica. / Several substances have been used for the disinfection and hygiene of acrylic resin devices, however, many of these substances are used empirically. Thus, the aim of this study was to evaluate the influence of immersion in vinegar, sodium hypochlorite and hydrogen peroxide on the surface roughness and hardness of thermo-cured acrylic resin Meliodent® Heat Cure (Heraeus Kultzer, Germany). 130 specimens of acrylic resin were produced and randomly divided into 13 groups (n = 10). The control group remained dry without immersion. The test groups were immersed in vinegar, 1% sodium hypochlorite, hydrogen peroxide 10V and distilled water during different times (30h, 150h and 300h). The solutions were protected from light and changed every 24 hours. After the immersion period, Knoop hardness and surface roughness of the acrylic resin were evaluated. The Knoop hardness of the specimens were obtained through an automatic microhardness tester HMV-2 (Shimadzu, Japan) with five measurements on each specimen with a load of 25g for 10 seconds. The roughness was determined by five readings on each specimen using a Surface Roughness Tester SJ-201 (Mitutoyo, Japan). The results showed a statistically significant difference in microhardness after immersion for 30h, 150h and 300h in vinegar, 1% sodium hypochlorite, hydrogen peroxide and distilled water 10V, compared with the control group. The results of roughness showed no statistically significant difference after immersion for 30h, 150h and 300h in vinegar and distilled water when compared with the control group. Based on the experimental design and results of this study it can be concluded that vinegar can eventually become an option for homemade disinfecting apparatus of acrylic resin.
10

Influência de imersões em vinagre sobre a rugosidade e a dureza de uma resina acrílica de termoativação / Influence of vinegar immersions at surface roughness and microhardness of one thermo cured acrylic resin

Jiménez Pereira, Cláudia January 2014 (has links)
Diversas substâncias químicas têm sido utilizadas no processo de desinfecção e higiene de dispositivos de resina acrílica, no entanto, muitas destas substâncias são utilizadas de forma empírica. Sendo assim, o objetivo do presente estudo foi avaliar a influência da imersão em vinagre, hipoclorito de sódio e peróxido de hidrogênio na rugosidade e na dureza de uma resina acrílica de termoativação Meliodent® Heat Cure (Heraeus Kultzer, Alemanha). Foram confeccionados 130 corpos de prova de resina acrílica e estes foram aleatoriamente divididos em 13 grupos (n=10). O grupo controle permaneceu a seco, sem imersão. Os grupos teste foram submetidos à imersão em vinagre, hipoclorito de sódio 1%, peróxido de hidrogênio 10V e água destilada por diferentes tempos (30h, 150h ou 300h). As soluções foram protegidas da luz e trocadas a cada período de 24 horas. Após o período de imersão foram avaliadas a microdureza Knoop e a rugosidade Ra da resina acrílica. A microdureza Knoop dos corpos foi obtida com o microdurômetro automático HMV-2 (Shimadzu, Japão) sendo utilizada a medida de cinco mensurações em cada corpo de prova com uma carga de 25g por 10 segundos. A rugosidade Ra foi determinada pela media de cinco leituras realizadas em cada corpo de prova, utilizando-se um Rugosímetro SJ-201 (Mitutoyo, Japão). Os resultados mostraram que houve diferença estatisticamente significativa na microdureza da resina acrílica de termopolimerização após a imersão durante 30h, 150h e 300 h em vinagre, hipoclorito de sódio 1%, peróxido de hidrogênio 10V e água destilada, quando comparado com o grupo controle, que permaneceu a seco. Os resultados da rugosidade não mostraram diferença estatisticamente significativa após a imersão durante 30h, 150h e 300h em vinagre e água destilada quando comparados com o grupo controle, sem imersão. Com base no desenho experimental e nos resultados do presente estudo é possível concluir que o vinagre pode se tornar uma opção para desinfecção caseira de dispositivos de resina acrílica. / Several substances have been used for the disinfection and hygiene of acrylic resin devices, however, many of these substances are used empirically. Thus, the aim of this study was to evaluate the influence of immersion in vinegar, sodium hypochlorite and hydrogen peroxide on the surface roughness and hardness of thermo-cured acrylic resin Meliodent® Heat Cure (Heraeus Kultzer, Germany). 130 specimens of acrylic resin were produced and randomly divided into 13 groups (n = 10). The control group remained dry without immersion. The test groups were immersed in vinegar, 1% sodium hypochlorite, hydrogen peroxide 10V and distilled water during different times (30h, 150h and 300h). The solutions were protected from light and changed every 24 hours. After the immersion period, Knoop hardness and surface roughness of the acrylic resin were evaluated. The Knoop hardness of the specimens were obtained through an automatic microhardness tester HMV-2 (Shimadzu, Japan) with five measurements on each specimen with a load of 25g for 10 seconds. The roughness was determined by five readings on each specimen using a Surface Roughness Tester SJ-201 (Mitutoyo, Japan). The results showed a statistically significant difference in microhardness after immersion for 30h, 150h and 300h in vinegar, 1% sodium hypochlorite, hydrogen peroxide and distilled water 10V, compared with the control group. The results of roughness showed no statistically significant difference after immersion for 30h, 150h and 300h in vinegar and distilled water when compared with the control group. Based on the experimental design and results of this study it can be concluded that vinegar can eventually become an option for homemade disinfecting apparatus of acrylic resin.

Page generated in 0.0525 seconds