• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 58
  • 3
  • 1
  • Tagged with
  • 62
  • 62
  • 40
  • 37
  • 20
  • 17
  • 13
  • 13
  • 11
  • 11
  • 11
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Efeito da triazina nas propriedades mecânicas e formação de biofilme em resina acrílica e reembasadores de prótese / Antimicrobial activity of triazine added to denture materials on saliva-derived microcosms: microbiological efficacy and mechanical properties

Moraes, Aline Pinheiro de 01 April 2011 (has links)
Made available in DSpace on 2014-08-20T14:30:16Z (GMT). No. of bitstreams: 1 Dissertacao_Aline Pinheiro_Moraes.pdf: 846337 bytes, checksum: 66b01044077d89e98213868cd5b7582a (MD5) Previous issue date: 2011-04-01 / Candidiasis is the most common fungal infection in denture wearers. The association between Candida and denture base is directly related to the efficiency of this micro-organism to adhere and colonize these surfaces, which is an essential initial step for the development of denture-related stomatitis. Additionally, the use of denture liners has increased, with these materials more prone to microbial adhesion when compared with acrylic resin due to its higher surface roughness. These materials have demonstrated capacity to interact with oral micro-organisms.This important problem is the reason why several attempts have been made to develop biomaterials containing antifungal. Thus, the aim of this study was to investigate the potential antifungal activity of triazine added to acrylic resin and liners used in prosthodontics using microcosms biofilm model with saliva derived from patients with or without candidiasis, verifying its effectiveness in reducing microbial adherence and consequently reduce the incidence of Candida infections. The mechanical properties of the tested materials after the incorporation of triazine were also evaluated. We considered four commercially available materials (a microwave-cured acrylic resin and two soft denture liners and one hard denture liner) to which were added different concentrations of triazine (0; 2.5; 5.0 and 10%). The results indicated that no difference were found among triazine concentrations in acrylic resin flexural strength (p= 0.059). Triazine addition did not result in surface roughness changes, although all denture liners presented higher surface roughness compared with acrylic resin, while in general, SoftConfort presented the highest roughness (p<0.001). In general, 5 and 10% triazine addition resulted in more soluble materials. All materials presented increased water sorption with the addition of triazine (p<0.05), except for CoeSoft, where no change was observed. Candidiasis patient saliva presented higher counts of total micro-organisms (p= 0.0294) and total streptococci (p = 0.0008). Regarding materials, total streptococci, total micro-organisms and Candida counts were higher in CoeSoft (p<0.0001). Candida species counts was the same for both saliva donors (p>0.05). The addition of triazine did not result in decrease of total micro-organisms, total streptococci or Candida species in all materials tested (p>0.05). In conclusion, the addition of triazine to acrylic resin and denture liners in a complex biofilm model did not modify the development of biofilms in both patients with and without candidiasis / A candidíase é a infecção oral fúngica mais comum em usuários de próteses. A associação entre o microrganismo Candida e as bases das próteses está diretamente relacionada à eficiência deste microrganismo em aderir e colonizar estas superfícies, sendo esta a etapa inicial essencial para o desenvolvimento da estomatite induzida por prótese. Associado a isto, o uso de reembasadores para próteses tem aumentado, sendo estes materiais mais propensos à adesão microbiana quando comparados a resina acrílica devido a sua maior rugosidade de superfície. Além disso, estes materiais tem demonstrado capacidade de interagir com microrganismos bucais. Este importante problema tem levado a tentativa de desenvolvimento de diversos materiais contendo agentes antifúngicos. Assim, o objetivo deste estudo foi investigar o potencial antifúngico da triazina adicionada à resina acrílica e reembasadores utilizados em prótese dentária, através de um modelo de biofilme de microcosmos, com salivas derivadas de pacientes com ou sem candidíase, verificando sua efetividade em reduzir a adesão microbiana e, consequentemente, diminuir a incidência de infecções por Candida. Também avaliaram-se as propriedades mecânicas dos materiais testados após a incorporação da triazina. Foram considerados quatro materiais comercialmente disponíveis (uma resina acrílica ativada por energia de micro-ondas, dois reembasadores resilientes e um reembasador permanente), aos quais foram adicionadas diferentes concentrações de triazina (0; 2,5; 5,0 e 10%). Os resultados indicaram que não houve diferença (p = 0,059) entre as concentrações de triazina para a resina acrílica de micro-ondas no teste de resistência à flexão. Em relação a rugosidade de superfície, embora a adição de triazina não tenha levado ao aumento da rugosidade, os reembasadores apresentaram maior rugosidade que a resina acrílica, com o SoftConfort apresentando, em geral, a maior rugosidade (p<0,001). De maneira geral, quando adicionada triazina a 5,0 e 10%, todos os materiais tornaram-se mais solúveis e apresentaram aumento de sorção de água (p<0,05), a exceção do CoeSoft, que não mostrou diferença com a adição do composto químico. Houve diferença entre salivas, sendo que aquela proveniente de individuo com candidíase apresentou maiores contagens de microrganismos totais (p = 0,0294) e estreptococos totais (p = 0,0008). Em relação aos materiais, a contagem de estreptococos, microrganismos totais e espécies de Candida foi maior no CoeSoft (p<0,0001). Entretanto, a contagem de espécies de Candida foi igual entre os doadores (p>0,05). A adição de triazina não resultou em diminuição de microrganismos totais, estreptococos totais ou espécies de Candida em nenhum dos materiais testados (p>0,05). Como conclusão, a adição de triazina a resina acrílica e reembasadores utilizados para confecção de base e reembasamento de próteses em um modelo complexo de biofilme não modificou o desenvolvimento de biofilmes em ambos os pacientes com ou sem candidíase
42

The Effect of Surface Treatment on The Adhesive Strength of Chairside Hard Liners to Dental Polymers Used for The Conventional, Additive, and Subtractive Fabrication of Complete Dentures.

Aldosari, Abdullah Mohammed January 2022 (has links)
No description available.
43

Análise da alteração dimensional em guias cirúrgicos de resina acrílica após esterilização por meio de plasma de peróxido de hidrogênio / Analysis of dimensional alterations of resin acrylic surgical splints after hydrogen peroxide plasma sterilization

Shigeoka, Anderson Akio 30 September 2009 (has links)
O presente trabalho verificou a alteração dimensional dos guias cirúrgicos confeccionados em resina acrílica para cirurgia ortognática quando submetidos à esterilização por meio de plasma de peróxido de hidrogênio. Foram utilizados 15 corpos de prova confeccionados em resina acrílica quimicamente ativada a partir de moldes metálicos em três espessuras: 1,5 mm, 3,0 mm e 5,0 mm, em um total de 45. A imagem de cada corpo de prova foi digitalizada antes e após o processo de esterilização e processada pelo programa Photoshop® CS2. Foi realizada a vetorização das imagens pelo programa Corel Trace ® 12 para mensuração pelo programa Corel Drawn ® 12. Os resultados foram submetidos ao teste estatístico dos postos sinalizados de Wilcoxon, ao nível de significância de 0,05%. Os resultados obtidos foram que nos corpos de prova de 1,5 mm de espessura não houve diferença estatisticamente significante entre as mensurações realizadas antes e após o processo de esterilização (P>0,05), porem, nas espessuras de 3,0 mm e 5,0 mm houve pelo menos uma das medidas estatisticamente diferentes (p=0,011 e p=0,017, respectivamente). Fato este que nos levou a acreditar que o processo de esterilização não leva a alteração dimensional, porem em volumes maiores provavelmente houve uma contração de polimerização diretamente proporcional. / Dimensional alterations in surgical splints made of acrylic resin used in orthognathic surgery were evaluated after hydrogen peroxide gas plasma sterilization. Fifteen specimens of resin acrylic was made by a metal model master with three different thickness: 1,5 mm, 3,0 mm and 5,0 mm, totally 45 specimens. Specimens digital image was acquired before and after sterilization and process by Photoshop® CD2 software. The images were transformed in vector form by Corel Trace® 12 software. The measures were performed by Corel Draw® 12 software. The results were submitted to Wilcoxon statistic method, 0.05 level of confidence. The results showed no statistical differences in 1.5 mm specimens (p0,307) before and after sterilization process but, in 3.0 and 5.0 mm, there was at least one measure statistically different (p=0,011 and p=0,017, respectively). It was possible to conclude that the sterilization process did not lead to dimensional alteration but, in higher thickness probably had happen a proportional polymerization contraction.
44

Avaliação da cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável sob a ação de soluções higienizadoras / Color, corrosion and surface roughness evaluation of titanium c.p., alloys and heat-polymerized acrylic resin under the action of daily hygiene solutions

Davi, Letícia Resende 03 May 2010 (has links)
A higienização das próteses parciais ou totais removíveis é fundamental para a durabilidade do tratamento e prevenção de patologias orais. O objetivo deste estudo foi avaliar o efeito de agentes higienizadores de prótese na cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável, simulando um período de 180 dias de higienização. Espécimes em formato de discos (12 mm x 3 mm) foram confeccionados em: titânio comercialmente puro (Tritan - Ti c.p.), liga de níquel-cromo-molibdênio-titânio (Vi-Star), liga de níquel-cromo (Fit Cast-SB Plus) e liga de níquel-cromo-berílio (Fit Cast-V). Cada disco fundido foi incluído em mufla previamente preparada por matrizes retangulares de teflon (38 mm x 18 mm x 4 mm), incorporando-se o disco metálico à resina acrílica termopolimerizável. Os corpos-de-prova (n=5) foram imersos em soluções dos agentes higienizadores: hipoclorito de sódio a 0,05%, Periogard, Cepacol, pastilha Corega Tabs, pastilha Medical Interporous e pastilha Polident 3 Minute. Como controle, foi utilizada a água deionizada. Foram realizados ensaios de estabilidade de cor por meio de espectrocolorímetro (Color-guide 45/0), resistência à corrosão por meio da análise visual da presença de manchas no metal e análise da alteração de massa (balança eletrônica analítica), e rugosidade superficial por meio de rugosímetro (Surftest SJ-201P). Além disso, foi realizada análise quantitativa de liberação de íons metálicos por meio de espectrometria de massa com plasma indutivamente acoplado (ICP-MS - ELAN DRC II). Os resultados de estabilidade de cor, alteração de massa e rugosidade foram submetidos à ANOVA e teste de Tukey (p< 0,05). Quanto à estabilidade de cor da resina acrílica termopolimerizável (E), houve diferença estatisticamente significante entre o titânio c.p. e as ligas. A resina associada ao Ti c.p. apresentou menor alteração de cor, enquanto que a resina associada à Fit Cast-SB Plus apresentou a maior alteração de cor (1,33 ± 1,11 e 5,06 ± 1,96, respectivamente). Com relação à presença de manchas no metal, o hipoclorito de sódio causou manchamento nos espécimes das ligas Vi-Star e Fit Cast-V. Quando avaliada a alteração de massa (g), o Cepacol e a pastilha Corega Tabs propiciaram maior perda de massa. Entre os metais, a amostra do Ti c.p. apresentou maior perda de massa. Quanto à rugosidade (Ra, µm) da resina, o Cepacol causou maior rugosidade, enquanto que a pastilha Corega Tabs e o Periogard propiciaram maior lisura no corpo-de-prova. A resina associada ao Ti c.p. e ao Fit Cast-SB Plus apresentaram maior rugosidade. Quanto à rugosidade do metal, os produtos de imersão não influenciaram nos resultados, mas a liga Fit Cast-SB Plus apresentou maior rugosidade após a imersão. A liberação de íons mais expressiva foi constatada nas ligas Vi-Star e Fit Cast-V após a imersão na pastilha Medical Interporous. Pode-se concluir que as ligas Vi-Star e Fit Cast-V podem ser consideradas seguras para a confecção de aparelhos protéticos removíveis, mas com a condição de não utilizar o hipoclorito de sódio a 0,05% ou a pastilha Medical Interporous para a higienização, pois causaram corrosão e maior liberação de íons, respectivamente. / The hygiene care of the removable partial and complete dentures is required for the longevity of the treatment and prevention of oral diseases. The aim of this study was to evaluate the effect of denture cleansers on color, corrosion and surface roughness of the commercially pure titanium, metal alloys and heat-polymerized acrylic resin, simulating a period of 180 days of hygiene. Disk-shaped specimens (12 mm x 3 mm) had been fabricated with commercially pure titanium (Tritan - Ti c.p.), nickel-chromium-molybdenum-titanium alloy (Vi-Star), nickel-chromium alloy (Fit Cast-SB Plus) and nickel-chromium-beryllium alloy (Fit Cast-V). Each cast disc was invested in the flasks previously prepared by Teflon rectangular matrices (38 mm x 18 mm x 4 mm), incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n= 5) had been immersed in the solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous and Polident 3 Minute. As a control, it was used deionized water. It was accomplished assays of color stability by means of a colorimeter (Color-guide 45/0), corrosion resistance by means of visual analysis of tarnishes on the metal and mass alteration analysis (analytical electronic balance), and surface roughness by means of a surface analyzer (Surftest SJ-201P). Besides, the quantitative analysis of metal ions release was accomplished by means of inductively coupled plasma mass spectrometry (ICP-MS - ELAN DRC II). Color stability, mass alteration and roughness results were submitted to ANOVA and Tukey test (p<0.05). Considering the color stability of the heat-polymerized acrylic resin (E), there were statistically significant difference between the titanium c.p. and the alloys. The resin associated with the Ti c.p. showed lesser color alteration, whereas the resin associated with Fit Cast-SB Plus showed the higher color alteration (1,33 ± 1,11 e 5,06 ± 1,96, respectively). In relation to the presence of tarnishes on the metals, the sodium hypochlorite caused tarnishes on specimens of the Vi-Star and Fit Cast-V alloys. When evaluated the mass alteration (g), Cepacol and Corega Tabs propitiated higher weight loss. Between the metals, the Ti c.p. samples showed greater weight loss. Considering the resin roughness (Ra, µm), Cepacol caused higher roughness, whereas Corega Tabs and Periogard propitiated greater smoothness on the specimens. The resin associated with the Ti c.p. and Fit Cast-SB Plus showed higher roughness. Considering the metal roughness, the immersion products did not influence on the results, but the Fit Cast-SB Plus showed greater roughness after immersion. The ionic release most significant was with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. It could be concluded that the Vi-Star and Fit Cast-V alloys can be considered safe for removable prosthesis finish, but with the condition of do not use sodium hypochlorite 0.05% or Medical Interporous tablet for hygiene, because they caused corrosion and greater ionic release, respectively.
45

Efeito da adição de fibras de vidro particuladas nas propriedades mecânicas de resinas acrílicas utilizadas para a confecção de placas oclusais / Effect of addition of the particulate glass fibers in mechanical properties of acrylic resins used for the making occlusal splints

Soares, Rodrigo Gonçalves 06 July 2010 (has links)
Placas oclusais são dispositivos intraorais utilizados no manejo de pacientes que apresentam desordens do sono, migrânia do tipo tensional e outros. No entanto são os cirurgiões dentistas que predominantemente utilizam as placas oclusais como tratamento do equilíbrio das arcadas dentárias nas disfunções temporomandibulares, prevenção de desgaste dental em pacientes com hábitos parafuncionais e na prevenção de traumas em atletas. Vários métodos têm sido empregados para reforçar resinas acrílicas, como reforço metálico e atualmente a incorporação de diferentes tipos de fibras tais como: carbono, polietileno e vidro. Contudo a adição de fibras de vidro com partículas menores em algumas propriedades mecânicas ainda permanecem desconhecidas. Objetivo: O objetivo desse estudo foi avaliar algumas propriedades mecânicas como a rugosidade de superfície, microdureza, módulo de elasticidade e resistência flexural em resinas acrílicas após a incorporação de fibras de vidro particuladas pré silanizadas. Material e método: Para avaliação das propriedades foram confeccionados vinte e quatro corpos de prova (65 x 10 x 3 mm) de cada marca comercial de resina acrílica, utilizadas para confecção de placas oclusais, Vipi Flash (autopolimerizável), Vipi Wave (termopolimerizável por calor de microondas), Vipi Crill, Lucitone e QC-20 (termopolimerizáveis por calor de banho de água), sendo doze corpos-de-prova controles, e doze experimentais, com adição de 10% em peso de fibras de vidro particuladas (Reforplás S/A, São Paulo, SP, Brasil). Após a realização do acabamento superficial dos corpos de prova com lixas de carborundum e feltros era realizada a avaliação da rugosidade superficial em rugosímetro (Mitutoyo®) com três leituras ao longo dos corpos-de-prova, a microdureza Vickers era analisada em um microdurômetro (Micro Hardness Tester, Shimadzu, Japan) com cinco mensurações em cada corpo-de-prova, e para avaliar os ensaios de resistência flexural e módulo de elasticidade os corpos-de-prova foram avaliados por meio uma máquina de ensaios universal (Emic DL 2000®, Emic, São José dos Pinhais, PR, Brasil), com velocidade de 5mm/min. Os dados foram analisados estatisticamente, usando testes paramétricos e não paramétricos, de acordo com a distribuição da amostra. Resultados: As médias e desvios padrões do teste de rugosidade superficial em Ra foram Vipi Flash sem fibra (0,10 ± 0,03); Vipi Flash com fibra (0,12 ± 0,01); Vipi Wave sem fibra (0,16 ± 0,02); Vipi Wave com fibra (0,13 ± 0,02); Vipi Cril sem fibra (0,12 ± 0,03); Vipi Crill com fibra (0,15 ± 0,03); Lucitone sem fibra (0,10 ± 0,02); Lucitone com fibra (0,09 ± 0,04); QC-20 sem fibra (0,11 ± 0,02) e QC-20 com fibra (0,18 ± 0,03). As médias e desvios-padrão ao teste de microdureza Knoop com relação às marcas comerciais foram: Vipi Flash sem fibra (15,35 ± 0,3); Vipi Flash com fibra (15,51 ± 0,4); Vipi Wave sem fibra (16,60 ± 0,8); Vipi Wave com fibra (17,25 ± 0,9); Vipi Cril sem fibra (17,78 ± 2,27); Vipi Crill com fibra (18,02 ± 1,0); Lucitone sem fibra (15,72 ± 0,3); Lucitone com fibra (16,69 ± 0,6); QC-20 sem fibra (15,91 ± 0,4) e QC-20 com fibra (15,63 ± 0,2). As médias e desvios-padrão ao teste de módulo de elasticidade foram: Vipi Flash sem fibra (2952,76 ± 292,12); Vipi Flash com fibra (3373,49 ± 403,76); Vipi Wave sem fibra (2511,69 ± 304,09); Vipi Wave com fibra (3225,01 ± 248,66); Vipi Cril sem fibra (2745,61± 288,86); Vipi Crill com fibra (3671,67 ± 329,91); Lucitone sem fibra (1904,53 ± 149,05); Lucitone com fibra (3056,87 ± 126,11); QC-20 sem fibra (1913,86 ± 147,80) e QC-20 com fibra (2858,32 ± 185,26). As médias e desvios-padrão ao teste de resistência flexural foram Vipi Flash sem fibra (81,62 ± 4,82); Vipi Flash com fibra (83,98 ± 4,98); Vipi Wave sem fibra (83,52 ± 8,79); Vipi Wave com fibra (88,98± 8,47); Vipi Cril sem fibra (64,17± 5,46); Vipi Crill com fibra (93,37 ± 9,97); Lucitone sem fibra (74,71± 9,43); Lucitone com fibra (87,29 ± 4,73); QC-20 sem fibra (75,80 ± 8,82) e QC-20 com fibra (81,67± 12,97). Conclusão: Conclui-se que a incorporação de fibras provocou alterações em praticamente todas as propriedades analisadas, sendo, portanto facilmente utilizável como um reforço adicional às resinas acrílicas. Com relação à dureza superficial as resinas acrílicas termopolimerizável por banho de água e termopolimerizável por calor de microondas apresentaram maiores valores quando comparados com a resina acrílica autopolimerizável. Além disso, a adição de fibras de vidro particuladas aumentou os valores de rugosidade de algumas resinas acrílicas Vipi Crill, Vipi Flash e Vipi Wave e se manteve constante nas resinas Lucitone e QC-20. A adição de fibra de vidro não aumentou significantemente a microdureza Knoop nos grupos em estudo. Com relação à resistência flexural as fibras de vidro particuladas aumentaram significantemente todos os valores, assim como o módulo de elasticidade das resinas acrílicas reforçadas pela adição de fibras de vidro. / Intraoral Occlusal splints are devices used in the management of patients with sleep disorders, migraine type tension and others. But dentists who are predominantly using the plates as a treatment of occlusal balance of the dental arches in temporomandibular disorders, prevention of tooth wear in patients with habits and prevention of injuries in athletes. Several methods have been used to strengthen acrylic resins, such as metal reinforcement and are currently incorporating different types of fibers such as carbon, polyethylene and glass. However the addition of glass fibers with smaller particles on mechanical properties are still unknown. Objective: The objective of this study was to evaluate some mechanical properties such as surface roughness, hardness, elastic modulus and flexural strength in acrylic resins after the incorporation of glass fiber particulate pre silanized. Methods: To evaluate the properties were made twenty-four specimens (65 x 10 x 3 mm) of each brand of acrylic resin, used for fabrication of occlusal splints, Vipi Flash (self-curing), Vipi Wave (by thermo microwave heat), Vipi CRILL, Lucitone and QC-20 (thermo heat water bath), with twelve specimes controls, and twelve experimental, with the addition of 10 wt% glass fiber particulate (Reforplás S / A, São Paulo, Brazil). After completion of the roughness of the specimens with grit carborundum and felt it was evaluated the surface roughness on roughness tester (Mitutoyo ®) with three readings over the specimes, the microhardness was examined with a hardness ( Micro Hardness Tester, Shimadzu, Japan) with five measurements in each specime, and evaluate the tests for flexural strength and modulus of elasticity of the specimes was evaluated using a universal testing machine (Emic DL 2000 ®, Emic, São José dos Pinhais, PR, Brazil), with speed 5mm/min. The data were statistically analyzed using parametric and nonparametric tests, according to the sample distribution. Results: The mean and standard deviation of the test surface roughness were Vipi Flash without fiber (0.10 ± 0.03); Flash Vipi with fiber (0.12 ± 0.01); Vipi Wave without fiber (0, 16 ± 0.02); Vipi Wave with fiber (0.13 ± 0.02); Vipi Cril without fiber (0.12 ± 0.03); Vipi CRILL with fiber (0.15 ± 0.03); Lucitone without fiber (0.10 ± 0.02); Lucitone with fiber (0.09 ± 0.04), QC-20 fiber without (0.11 ± 0.02) and QC-20 with fiber (0.18 ± 0.03). Means and standard deviations for Knoop microhardness test with respect to trademarks were Vipi Flash without fiber (15.35 ± 0.3); Flash Vipi with fiber (15.51 ± 0.4); Vipi Wave without fiber (16.60 ± 0.8); Vipi Wave with fiber (17.25 ± 0.9); Vipi Cril without fiber (17.78 ± 2.27); Vipi CRILL with fiber (18.02 ± 1.0 ); Lucitone without fiber (15.72 ± 0.3); Lucitone with fiber (16.69 ± 0.6), QC-20 without fiber (15.91 ± 0.4) and QC-20 with fiber (15 , 63 ± 0.2). Means and standard deviations to test elastic modulus were Vipi Flash without fiber (2952.76 ± 292.12); Flash Vipi with fiber (3373.49 ± 403.76); Vipi Wave without fiber (2511.69 ± 304.09); Vipi Wave with fiber (3225.01 ± 248.66); Vipi Cril without fiber (2745.61 ± 288.86); Vipi CRILL with fiber (3671.67 ± 329.91); Lucitone without fiber (1904.53 ± 149.05); Lucitone with fiber (3056.87 ± 126.11), QC-20 without fiber (1913.86 ± 147.80) and QC-20 with fiber (2858.32 ± 185 26). Means and standard deviations for flexural strength were Vipi Flash without fiber (81.62 ± 4.82); Flash Vipi with fiber (83.98 ± 4.98); Vipi Wave without fiber (83.52 ± 8 , 79); Vipi Wave with fiber (88.98 ± 8.47); Vipi Cril without fiber (64.17 ± 5.46); Vipi CRILL with fiber (93.37 ± 9.97); Lucitone without fiber ( 74.71 ± 9.43); Lucitone with fiber (87.29 ± 4.73), QC-20 without fiber (75.80 ± 8.82) and QC-20 with fiber (81.67 ± 12.97). Conclusion: the conclusion is that the incorporation of fibers resulted in changes in almost all properties examined, and thus easily used as an additional reinforcement for acrylic resins. With respect to the surface roughness of acrylic resins by thermo water bath and microwave thermo heat showed higher values when compared with acrylic resin. Moreover, the addition of glass fiber particulate increased the roughness values of some acrylic resins Vipi CRILL, Vipi Flash and Vipi Wave and remained constant in the resins Lucitone and QC-20. The addition of glass fiber does not increase significantly the microhardness in the groups. With respect to flexural strength glass fiber particulate significantly increased all values, as well as the modulus of acrylic resin reinforced by the addition of glass fibers.
46

Uso da palha de carna?ba em revestimento de dutos

Fernandes, J?ssica Emanuela de Ara?jo 28 February 2011 (has links)
Made available in DSpace on 2014-12-17T15:41:55Z (GMT). No. of bitstreams: 1 JessicaEAF_DISSERT.pdf: 2802549 bytes, checksum: f4835fb277277d60879f0b91ee07c465 (MD5) Previous issue date: 2011-02-28 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / In this work, the plant species Copernicia prunifera (Miller) H. E. Moore (carnauba), naturally occurring which prevails in the northeast region of Brazil was the subject of studies aiming its use as external coating of pipelines used in petroleum industry. The part of the plant worked were the leaves, also called straw, which were coated with resinous material. For this purpose, it was necessary to evaluate the effectiveness of the use of acrylic resins in the straw carnauba coating. The properties of the untreated carnauba straw and chemically treated with sodium hydroxide, hexane and carbon tetrachloride were investigated by ATRFTIR, SEM and thermal analysis. The first two techniques showed that treatment with solvents has caused major changes in the straw surface, while the thermal analysis indicated that the sodium hydroxide caused variations in thermal stability of straw constituents. Water absorption measurements showed that treatments have accelerated the absorption process and the reduction of contact angle values for treated samples with solvents indicated higher hidrophilicity of straw. The tensile tests showed lower values of elastic modulus and tensile strength for treated samples. Furthermore, coatings using pure commercial resins A and B as well as the formulations with clay were applied in straw and they were examined once again through thermal analysis, water absorption measurements, contact angle and mechanical tests. To analyze the effect of heat ageing, samples were subjected to tensile tests again in order to assess its resistance. The results showed that the resins/clay formulations increased thermal stability of straw, they promoted a good impermeabilization and caused significant decrease in the values of elastic modulus and tensile strength. Evaluating the ageing effect on the mechanical properties, it has been showed good recovery to the coated straw with the formulations A 60 and A 80% in modulus and tensile strength values and elongation at break values have remained very close. It is thus concluded that the carnauba straw can be used as a coating of pipelines with significant cost savings, since there is no need for pretreatment for its use and shows itself as a viable biotechnology alternative, contributing to the quality of coatings material and environment preservation. / Neste trabalho, a esp?cie vegetal Copernicia prunifera (Miller) H. E. Moore (carna?ba), de ocorr?ncia natural predominante da regi?o Nordeste do Brasil, foi alvo de estudos objetivando sua utiliza??o como revestimento externo de dutos da ind?stria do petr?leo. A parte da planta trabalhada foram as folhas, tamb?m chamadas de palhas, que receberam um revestimento resinoso. Para tanto, foi necess?rio avaliar a efic?cia do uso de resinas acr?licas no revestimento da palha de carna?ba. As propriedades da palha n?o-tratada e tratada quimicamente com hidr?xido de s?dio, hexano e tetracloreto de carbono foram investigadas por FTIR-ATR, MEV e TG. As duas primeiras t?cnicas mostraram que os tratamentos com os solventes provocaram maiores modifica??es na superf?cie da palha, enquanto o estudo termogravim?trico indicou que o hidr?xido de s?dio causou varia??es na estabilidade t?rmica dos constituintes da palha. Medidas de absor??o de ?gua mostraram que os tratamentos aceleraram o processo de absor??o e a redu??o dos valores de ?ngulo de contato para as amostras tratadas com os solventes indicou aumento da hidrofilicidade das palhas. Os ensaios mec?nicos apresentaram menores valores de m?dulo el?stico e tens?o de ruptura para as amostras tratadas. Al?m disso, revestimentos com resinas comerciais puras A e B assim como composi??es com argila foram aplicados nas palhas e estas foram analisadas novamente atrav?s da termogravimetria, medidas de absor??o de ?gua, ?ngulo de contato e resist?ncia mec?nica. Para analisar o efeito do envelhecimento t?rmico realizado, as amostras foram submetidas mais uma vez aos ensaios mec?nicos, a fim de avaliar sua resist?ncia. Os resultados mostraram que as formula??es resinas/argila aumentaram a estabilidade t?rmica da palha, promoveram uma boa impermeabiliza??o e causaram significativa redu??o nos valores de m?dulo el?stico e tens?o de ruptura. Ao avaliar o efeito do envelhecimento nas propriedades mec?nicas, percebeu-se boa recupera??o nos valores de m?dulo e tens?o para a palha revestida com as formula??es A 60 e A 80%. J? os resultados de deforma??o mostraram que os valores permaneceram bem pr?ximos. Dessa forma, conclui-se que a palha de carna?ba pode vir a ser utilizada como revestimento de dutos com significante redu??o de custos, j? que n?o h? a necessidade de tratamento pr?vio para seu uso e mostra-se como uma alternativa biotecnol?gica vi?vel, contribuindo com a qualidade de material de revestimentos e a preserva??o do meio ambiente.
47

Caracterização e propriedades das resinas acrílicas de uso odontológico : um enfoque voltado para a biossegurança

Fortes, Carmen Beatriz Borges January 2007 (has links)
O Brasil, à semelhança de outros países, está envelhecendo rapidamente. Os indivíduos com mais de 60 anos compõem hoje o segmento que mais cresce em termos proporcionais, mostrando um incremento da ordem de 500%, em 40 anos. A estimativa para o ano de 2020 é de que o Brasil tenha em torno de 32 milhões de indivíduos idosos, e desta população, uma parcela significativa será parcial ou totalmente desdentada, necessitando de aparelhos protéticos. Apesar da Odontologia apresentar avanços científicos notáveis na reabilitação da saúde bucal, muitos ainda usarão estes aparelhos. Sabe-se que o uso contínuo de próteses pode propiciar o desenvolvimento da estomatite protética, cuja etiologia é multifatorial, destacando-se principalmente a má higiene bucal e da prótese, e geralmente associada à presença de Candida albicans. Desta forma, há necessidade de se propor um método de desinfecção, que se mostre eficaz, que seja seguro quanto à toxicidade, que represente baixo risco ocupacional, que seja de fácil manuseio e que não interfira nas propriedades dos materiais utilizados na confecção destes aparelhos. Portanto, a proposição deste trabalho foi avaliar a influência de dois métodos de desinfecção, nas propriedades das resinas acrílicas empregadas na confecção das próteses.As propriedades avaliadas foram: resistência e módulo de flexão, resistência ao impacto Izod, microdureza Knoop, rugosidade, massa específica e grau de inchamento, grau de conversão do monômero, temperatura de transição vítrea, sorção e solubilidade. Os corpos de prova foram confeccionados de acordo com os requisitos de cada ensaio, tanto para os grupos controle (sem tratamento), quanto para os tratados (submetidos a um dos processos de desinfecção). Os tratamentos de desinfecção consistiram de: a) irradiação com energia de microondas na potência de 840 W, durante 1 minuto; b) imersão em ácido peracético durante 5 minutos. A eficácia da desinfecção foi avaliada através de ensaios microbiológicos que consistiram em verificar o crescimento no meio de cultura e na superfície do corpo de prova de Candida albicans, após a desinfecção dos corpos de prova, previamente contaminados com uma cepa conhecida do fungo (ATCC 10231). Como as resinas acrílicas são materiais muito utilizados em todas as áreas de atuação da Odontologia, o conhecimento das suas propriedades é de interesse do cirurgião-dentista. As resinas acrílicas tipo 1 (de termopolimerização), tipo 2 (quimicamente ativada) e tipo 5 (ativada por microondas) foram avaliadas neste trabalho. Os resultados mostraram que as resinas acrílicas tipo 1 e tipo 5 apresentam valores semelhantes em todas as propriedades analisadas. A resina acrílica tipo 2 apresentou valores inferiores àqueles encontrados nas tipo 1 e 5. O ciclo de polimerização com melhores resultados foi aquele proposto pelo respectivo fabricante daresina acrílica. A presença de fibras de nylon e de corante não influenciou as propriedades da resina acrílica tipo 5. Das técnicas de desinfecção, a imersão em ácido peracético apresentou os melhores resultados para todas as propriedades avaliadas ao longo do tempo de 20 meses. Por outro lado a irradiação de microondas, a longo prazo, apresentou os piores resultados para todas as propriedades avaliadas. Ambas as técnicas de desinfecção foram eficazes do ponto de vista microbiológico. Mas, para o uso prolongado, a técnica de desinfecção com ácido peracético pode ser recomendada com toda a segurança, no que diz respeito às propriedades avaliadas neste trabalho. / Brazil, similar to other countries, is aging quickly. The individuals with more than 60 years old compose today the segment that more grows in proportional terms, showing an increment of about 500% in 40 years. The estimate for 2020 is that Brazil has around 32 million elderly and a significant parcel of them will be partial or totally toothless, needing prosthetic equipments. In spite of notable scientific advance in the rehabilitation of the oral health, many people still will use these equipments. The continuous use of the prosthesis can propitiate the development of denture stomatitis, whose etiology is multifactorial, being generally, associated to the presence of fungus Candida albicans. Bad oral hygiene and prosthesis is still distinguished as factor of risk. Therefore, it very necessary for the elderly a efficient, safe and easy handling method of disinfection with low occupational risk and that doesn’t intervene with the properties of the materials used in the confection of these prosthetic equipments. The aim of this work is to evaluate the influence of two disinfection methods on the properties of acrylic resin used in the confection of dental prosthesis. Samples had been confectioned in accordance with the requirements of each test for the control groups (without treatment), as for the treated (submitted to one of the disinfection process). The evaluated properties had been resistance and module of flexure, Izod impact, Knoop microhardness, rugosity, specific mass and degree of swelling, degree of conversion of monomer, glass transition temperature, sorption and solubility. The treatments of disinfection had consisted of: a) irradiation with energy of microwaves, in the power of 840 W, during 1 min, or b) immersion in peracetic acid during 5 min. The effectiveness of the disinfection was evaluated by means of microbiological tests, in which was verified the occurrence of growth of Candida albicans through of culture and sample surface. For that, the samples were previously contaminated with one type of fungus (known as ATCC 10231) and, after, submitted to one of the two considered processes of disinfection. The work was studied the behavior of three commercial acrylic resins of dental use: acrylic resins of thermal polymerization, self-polymerization and polymerization for energy of microwaves (type 1, 2 and 5 respectively) from two different suppliers The results had shown that the acrylic resins of type 1 and type 5 presented similar values in all the analyzed properties. The acrylic resins of type 2 had also similar values in all the properties, but statistically lower than ones of type 1 and 5. The best polymerization cycle, which did not modify the resin properties, was that one considered by the respective manufacturer of the acrylic resin. The nylon fiber presence and colouring did not influence the properties of the acrylic resin of type 5. The first irradiation with microwaves significantlyincreased the evaluated properties and the first immersion in peracetic acid did not modify these properties, in comparison to the control groups. After 20 months, the immersion in peracetic acid did not modify the properties of the material, while the microwave irradiation showed alterations in some properties. Both disinfection techniques had been efficient of the microbiological point of view. On the basis of these results, can be concluded that the microwave irradiation after the polymerization of the material (first cycle), can be recommended, since it increased all the values of the evaluated properties, specially to the conversion degree monomer/polymer. Nevertheless, for prolonged use, the disinfection by means of the immersion in peracetic acid must be recommended, it is efficient for elimination of fungal microorganism and security, characterized for the maintenance of the properties of the acrylic resin evaluated in this work.
48

Avaliação da resistência flexional, do módulo de elasticidade e do tipo de fratura de uma resina acrílica para restaurações provisórias - efeito de diversos reforços\"

Bastos, Luiz Gustavo Cavalcanti 30 April 2003 (has links)
A importância das restaurações provisórias no tratamento reabilitador oral é inquestionável. Os materiais utilizados para a execução destas restaurações, entretanto, são críticos com relação à resistência e longevidade, principalmente, quando estas são executadas em tratamentos prolongados e/ou em espaços desdentados extensos. A proposta deste trabalho foi determinar o efeito de diversos reforços sobre a resistência flexional, o módulo de elasticidade e o tipo de fratura apresentados por espécimes confeccionados em uma resina poli(metilmetacrilato) (PMMA), quando submetidos a um teste de carga de três pontos. Sete tipos de reforços constituíram os grupos experimentais com dez espécimes cada: um fio de aço com 0,7 mm de diâmetro; um fio de amarrilho trançado; uma fibra de vidro trançada Interlig® (Angelus®); uma fibra de vidro entrelaçada Splint-It!® (Jeneric-ron®); uma fibra de vidro unidirecional Fibrante® (Angelus®); uma fibra de poli(etileno) Connect® (Kerr®) e uma fibra cerâmica flexível GlasSpan® (GlasSpan®). O grupo controle, também com dez amostras, foi composto de espécimes não reforçados. A confecção dos espécimes, o ensaio mecânico e cálculo da resistência flexional e do módulo de elasticidade foram realizados seguindo norma ISO 10477 – modificada. A análise dos resultados (ANOVA, p < 0,05), para ambas as propriedades, mostrou haver diferença estatística entre os grupos. O teste de Tukey encontrou que os grupos reforçados com fio de aço com 0,7 mm; fibra Interlig® e fibra Connect® aumentaram significantemente a resistência flexional, e que os grupos reforçados com fio de aço com 0,7 mm; fibra Interlig®; fibra Splint-It!®; fibra Connect® e fibra GlasSpan®, aumentaram o módulo de elasticidade, em relação ao grupo controle. A análise das fraturas concorreu com a elaboração de um novo sistema de classificação dividindo-as em quatro tipos: Ausente, Parcial, Total Não Separada e Total Separada. As fraturas dos espécimes reforçados foram consideradas mais favoráveis ocorrendo, predominantemente, os tipos Ausente e Parcial. / Provisional restorations are essential components of oral rehabilitation treatment. The strength and durability features are, however, critical whe n long-term treatment is needed. The aim of this work was to measure the flexural strength, the elastic modulus and the type of fracture of poly (methyl methacrylate) (PMMA) resin specimens when submitted to a three-point-bend test. Seven types of reinforcements constituted the experimental groups with ten specimens each: a 0.7 mm of diameter wire; an orthodontic braided wire; a braided fiberglass Interlig® (Angelus®); an woven fiberglass Splint-It!® (Jeneric-Pentron®); a roving fiberglass Fibrante® (Angelus®); a braided poly(ethylene) fiber Connect® (Kerr®) and a flexible ceramic fiber GlasSpan® (GlasSpan®). The control group, also with ten samples, included not reinforced specimens. All specimens were made and test according to modified ISO specification No. 10477. The analysis of the results (ANOVA, p < 0.05), for both properties, showed significant differences between groups. Tukey\'s test detected higher figures for groups reinforced with wire of 0.7 mm of diameter wire; Interlig® and Connect® when flexural strength was concerned. Groups reinforced with a wire 0.7 mm of diameter; Interlig®; Splint-It!®; Connect® and GlasSpan®, increased the elastic modulus, when compared to the control group. The fractures analysis contributed with the elaboration of new index system dividing them in four types: Absent, Partial, Total Not Separated and Total Separated. It was observed that the reinforced specimens fractures were more favorable, occurring, predominantly, in the Absent and Partial types.
49

Avaliação da cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável sob a ação de soluções higienizadoras / Color, corrosion and surface roughness evaluation of titanium c.p., alloys and heat-polymerized acrylic resin under the action of daily hygiene solutions

Letícia Resende Davi 03 May 2010 (has links)
A higienização das próteses parciais ou totais removíveis é fundamental para a durabilidade do tratamento e prevenção de patologias orais. O objetivo deste estudo foi avaliar o efeito de agentes higienizadores de prótese na cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável, simulando um período de 180 dias de higienização. Espécimes em formato de discos (12 mm x 3 mm) foram confeccionados em: titânio comercialmente puro (Tritan - Ti c.p.), liga de níquel-cromo-molibdênio-titânio (Vi-Star), liga de níquel-cromo (Fit Cast-SB Plus) e liga de níquel-cromo-berílio (Fit Cast-V). Cada disco fundido foi incluído em mufla previamente preparada por matrizes retangulares de teflon (38 mm x 18 mm x 4 mm), incorporando-se o disco metálico à resina acrílica termopolimerizável. Os corpos-de-prova (n=5) foram imersos em soluções dos agentes higienizadores: hipoclorito de sódio a 0,05%, Periogard, Cepacol, pastilha Corega Tabs, pastilha Medical Interporous e pastilha Polident 3 Minute. Como controle, foi utilizada a água deionizada. Foram realizados ensaios de estabilidade de cor por meio de espectrocolorímetro (Color-guide 45/0), resistência à corrosão por meio da análise visual da presença de manchas no metal e análise da alteração de massa (balança eletrônica analítica), e rugosidade superficial por meio de rugosímetro (Surftest SJ-201P). Além disso, foi realizada análise quantitativa de liberação de íons metálicos por meio de espectrometria de massa com plasma indutivamente acoplado (ICP-MS - ELAN DRC II). Os resultados de estabilidade de cor, alteração de massa e rugosidade foram submetidos à ANOVA e teste de Tukey (p< 0,05). Quanto à estabilidade de cor da resina acrílica termopolimerizável (E), houve diferença estatisticamente significante entre o titânio c.p. e as ligas. A resina associada ao Ti c.p. apresentou menor alteração de cor, enquanto que a resina associada à Fit Cast-SB Plus apresentou a maior alteração de cor (1,33 ± 1,11 e 5,06 ± 1,96, respectivamente). Com relação à presença de manchas no metal, o hipoclorito de sódio causou manchamento nos espécimes das ligas Vi-Star e Fit Cast-V. Quando avaliada a alteração de massa (g), o Cepacol e a pastilha Corega Tabs propiciaram maior perda de massa. Entre os metais, a amostra do Ti c.p. apresentou maior perda de massa. Quanto à rugosidade (Ra, µm) da resina, o Cepacol causou maior rugosidade, enquanto que a pastilha Corega Tabs e o Periogard propiciaram maior lisura no corpo-de-prova. A resina associada ao Ti c.p. e ao Fit Cast-SB Plus apresentaram maior rugosidade. Quanto à rugosidade do metal, os produtos de imersão não influenciaram nos resultados, mas a liga Fit Cast-SB Plus apresentou maior rugosidade após a imersão. A liberação de íons mais expressiva foi constatada nas ligas Vi-Star e Fit Cast-V após a imersão na pastilha Medical Interporous. Pode-se concluir que as ligas Vi-Star e Fit Cast-V podem ser consideradas seguras para a confecção de aparelhos protéticos removíveis, mas com a condição de não utilizar o hipoclorito de sódio a 0,05% ou a pastilha Medical Interporous para a higienização, pois causaram corrosão e maior liberação de íons, respectivamente. / The hygiene care of the removable partial and complete dentures is required for the longevity of the treatment and prevention of oral diseases. The aim of this study was to evaluate the effect of denture cleansers on color, corrosion and surface roughness of the commercially pure titanium, metal alloys and heat-polymerized acrylic resin, simulating a period of 180 days of hygiene. Disk-shaped specimens (12 mm x 3 mm) had been fabricated with commercially pure titanium (Tritan - Ti c.p.), nickel-chromium-molybdenum-titanium alloy (Vi-Star), nickel-chromium alloy (Fit Cast-SB Plus) and nickel-chromium-beryllium alloy (Fit Cast-V). Each cast disc was invested in the flasks previously prepared by Teflon rectangular matrices (38 mm x 18 mm x 4 mm), incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n= 5) had been immersed in the solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous and Polident 3 Minute. As a control, it was used deionized water. It was accomplished assays of color stability by means of a colorimeter (Color-guide 45/0), corrosion resistance by means of visual analysis of tarnishes on the metal and mass alteration analysis (analytical electronic balance), and surface roughness by means of a surface analyzer (Surftest SJ-201P). Besides, the quantitative analysis of metal ions release was accomplished by means of inductively coupled plasma mass spectrometry (ICP-MS - ELAN DRC II). Color stability, mass alteration and roughness results were submitted to ANOVA and Tukey test (p<0.05). Considering the color stability of the heat-polymerized acrylic resin (E), there were statistically significant difference between the titanium c.p. and the alloys. The resin associated with the Ti c.p. showed lesser color alteration, whereas the resin associated with Fit Cast-SB Plus showed the higher color alteration (1,33 ± 1,11 e 5,06 ± 1,96, respectively). In relation to the presence of tarnishes on the metals, the sodium hypochlorite caused tarnishes on specimens of the Vi-Star and Fit Cast-V alloys. When evaluated the mass alteration (g), Cepacol and Corega Tabs propitiated higher weight loss. Between the metals, the Ti c.p. samples showed greater weight loss. Considering the resin roughness (Ra, µm), Cepacol caused higher roughness, whereas Corega Tabs and Periogard propitiated greater smoothness on the specimens. The resin associated with the Ti c.p. and Fit Cast-SB Plus showed higher roughness. Considering the metal roughness, the immersion products did not influence on the results, but the Fit Cast-SB Plus showed greater roughness after immersion. The ionic release most significant was with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. It could be concluded that the Vi-Star and Fit Cast-V alloys can be considered safe for removable prosthesis finish, but with the condition of do not use sodium hypochlorite 0.05% or Medical Interporous tablet for hygiene, because they caused corrosion and greater ionic release, respectively.
50

Caracterização e propriedades das resinas acrílicas de uso odontológico : um enfoque voltado para a biossegurança

Fortes, Carmen Beatriz Borges January 2007 (has links)
O Brasil, à semelhança de outros países, está envelhecendo rapidamente. Os indivíduos com mais de 60 anos compõem hoje o segmento que mais cresce em termos proporcionais, mostrando um incremento da ordem de 500%, em 40 anos. A estimativa para o ano de 2020 é de que o Brasil tenha em torno de 32 milhões de indivíduos idosos, e desta população, uma parcela significativa será parcial ou totalmente desdentada, necessitando de aparelhos protéticos. Apesar da Odontologia apresentar avanços científicos notáveis na reabilitação da saúde bucal, muitos ainda usarão estes aparelhos. Sabe-se que o uso contínuo de próteses pode propiciar o desenvolvimento da estomatite protética, cuja etiologia é multifatorial, destacando-se principalmente a má higiene bucal e da prótese, e geralmente associada à presença de Candida albicans. Desta forma, há necessidade de se propor um método de desinfecção, que se mostre eficaz, que seja seguro quanto à toxicidade, que represente baixo risco ocupacional, que seja de fácil manuseio e que não interfira nas propriedades dos materiais utilizados na confecção destes aparelhos. Portanto, a proposição deste trabalho foi avaliar a influência de dois métodos de desinfecção, nas propriedades das resinas acrílicas empregadas na confecção das próteses.As propriedades avaliadas foram: resistência e módulo de flexão, resistência ao impacto Izod, microdureza Knoop, rugosidade, massa específica e grau de inchamento, grau de conversão do monômero, temperatura de transição vítrea, sorção e solubilidade. Os corpos de prova foram confeccionados de acordo com os requisitos de cada ensaio, tanto para os grupos controle (sem tratamento), quanto para os tratados (submetidos a um dos processos de desinfecção). Os tratamentos de desinfecção consistiram de: a) irradiação com energia de microondas na potência de 840 W, durante 1 minuto; b) imersão em ácido peracético durante 5 minutos. A eficácia da desinfecção foi avaliada através de ensaios microbiológicos que consistiram em verificar o crescimento no meio de cultura e na superfície do corpo de prova de Candida albicans, após a desinfecção dos corpos de prova, previamente contaminados com uma cepa conhecida do fungo (ATCC 10231). Como as resinas acrílicas são materiais muito utilizados em todas as áreas de atuação da Odontologia, o conhecimento das suas propriedades é de interesse do cirurgião-dentista. As resinas acrílicas tipo 1 (de termopolimerização), tipo 2 (quimicamente ativada) e tipo 5 (ativada por microondas) foram avaliadas neste trabalho. Os resultados mostraram que as resinas acrílicas tipo 1 e tipo 5 apresentam valores semelhantes em todas as propriedades analisadas. A resina acrílica tipo 2 apresentou valores inferiores àqueles encontrados nas tipo 1 e 5. O ciclo de polimerização com melhores resultados foi aquele proposto pelo respectivo fabricante daresina acrílica. A presença de fibras de nylon e de corante não influenciou as propriedades da resina acrílica tipo 5. Das técnicas de desinfecção, a imersão em ácido peracético apresentou os melhores resultados para todas as propriedades avaliadas ao longo do tempo de 20 meses. Por outro lado a irradiação de microondas, a longo prazo, apresentou os piores resultados para todas as propriedades avaliadas. Ambas as técnicas de desinfecção foram eficazes do ponto de vista microbiológico. Mas, para o uso prolongado, a técnica de desinfecção com ácido peracético pode ser recomendada com toda a segurança, no que diz respeito às propriedades avaliadas neste trabalho. / Brazil, similar to other countries, is aging quickly. The individuals with more than 60 years old compose today the segment that more grows in proportional terms, showing an increment of about 500% in 40 years. The estimate for 2020 is that Brazil has around 32 million elderly and a significant parcel of them will be partial or totally toothless, needing prosthetic equipments. In spite of notable scientific advance in the rehabilitation of the oral health, many people still will use these equipments. The continuous use of the prosthesis can propitiate the development of denture stomatitis, whose etiology is multifactorial, being generally, associated to the presence of fungus Candida albicans. Bad oral hygiene and prosthesis is still distinguished as factor of risk. Therefore, it very necessary for the elderly a efficient, safe and easy handling method of disinfection with low occupational risk and that doesn’t intervene with the properties of the materials used in the confection of these prosthetic equipments. The aim of this work is to evaluate the influence of two disinfection methods on the properties of acrylic resin used in the confection of dental prosthesis. Samples had been confectioned in accordance with the requirements of each test for the control groups (without treatment), as for the treated (submitted to one of the disinfection process). The evaluated properties had been resistance and module of flexure, Izod impact, Knoop microhardness, rugosity, specific mass and degree of swelling, degree of conversion of monomer, glass transition temperature, sorption and solubility. The treatments of disinfection had consisted of: a) irradiation with energy of microwaves, in the power of 840 W, during 1 min, or b) immersion in peracetic acid during 5 min. The effectiveness of the disinfection was evaluated by means of microbiological tests, in which was verified the occurrence of growth of Candida albicans through of culture and sample surface. For that, the samples were previously contaminated with one type of fungus (known as ATCC 10231) and, after, submitted to one of the two considered processes of disinfection. The work was studied the behavior of three commercial acrylic resins of dental use: acrylic resins of thermal polymerization, self-polymerization and polymerization for energy of microwaves (type 1, 2 and 5 respectively) from two different suppliers The results had shown that the acrylic resins of type 1 and type 5 presented similar values in all the analyzed properties. The acrylic resins of type 2 had also similar values in all the properties, but statistically lower than ones of type 1 and 5. The best polymerization cycle, which did not modify the resin properties, was that one considered by the respective manufacturer of the acrylic resin. The nylon fiber presence and colouring did not influence the properties of the acrylic resin of type 5. The first irradiation with microwaves significantlyincreased the evaluated properties and the first immersion in peracetic acid did not modify these properties, in comparison to the control groups. After 20 months, the immersion in peracetic acid did not modify the properties of the material, while the microwave irradiation showed alterations in some properties. Both disinfection techniques had been efficient of the microbiological point of view. On the basis of these results, can be concluded that the microwave irradiation after the polymerization of the material (first cycle), can be recommended, since it increased all the values of the evaluated properties, specially to the conversion degree monomer/polymer. Nevertheless, for prolonged use, the disinfection by means of the immersion in peracetic acid must be recommended, it is efficient for elimination of fungal microorganism and security, characterized for the maintenance of the properties of the acrylic resin evaluated in this work.

Page generated in 0.0597 seconds