Spelling suggestions: "subject:"desistência flexural"" "subject:"esistência flexural""
1 |
"Estudo das resinas acrílicas para bases de próteses totais com relação à resistência flexural, e à quantidade de monômero residual superficial" / Study of acrylic resin for complete denture considering flexural strength and quantity of superficial residual mono merPaes Junior, Tarcisio José de Arruda 16 June 2005 (has links)
O objetivo deste trabalho foi o de avaliar a resistência à flexão e a quantidade de monômero residual superficial em resinas acrílicas para bases de próteses totais. Para tanto foram confeccionados corpos-de-prova nas dimensões de 2.5mm x 10mm x 65mm, utilizados em ambas as análises. Padronizou-se o processo de inclusão no qual foram empregadas muflas plásticas reforçadas por fibras de vidro. Sete grupos foram constituídos, de acordo com o tipo de processamento empregado na polimerização das resinas: Ac (Acron-MC) e Vw (Vipi-Wave) de ativação por energia de microondas; Lt (Lucitone 550 grupo controle) e Vc (Vipi-Cril), resinas de ativação térmica convencional em banho de água aquecida no ciclo longo; Qc (QC-20), uma resina de ativação térmica em ciclo rápido e, dois grupos cuja resina era a mesma de ativação química (Vipi-Flash), processada em duas condições à temperatura ambiente (Vf1) e, por aquecimento adicional em banho de água (Vf2). Os resultados mostraram diferenças estatisticamente significantes, onde o grupo Ac obteve as maiores médias para resistência flexural e os menores níveis de monômero liberado em relação às demais resinas. Os grupos Qc e Vf1 evidenciaram os piores resultados para ambos os testes, e a princípio, pareceu haver uma relação de causa e efeito entre, os elevados níveis de monômero residual encontrado nestes grupos, e a baixa resistência flexural observada. Verificou-se ainda que a imersão em água aquecida por 30min, da resina de ativação química, propiciou um ganho em qualidade do material para as características avaliadas. / The purpose of this work was the evaluation of flexural strength and quantity of superficial residual monomer in acrylic resin for complete denture. To perform both analyses it was developed specimens with a dimension of 2.5mm x 10mm x 65mm. The inclusion process was standardized by the use of plastic flasks reinforced with fiberglass. Seven groups were constituted in accordance with the type of resin polymerization process: Ac (Acron-MC) and Vw (Vipi-Wave) activated by microwave energy; Lt (Lucitone 550 control group) and Vc (Vipi-Cril), conventional water bath curing cycles of heat activated acrylic resin; Qc (QC-20), fast cycle thermal activation; and two groups of self cured resin (Vipi-Flash), processed in two distinguished conditions: ambient temperature (Vf1) and additional heating in water bath (Vf2). The results have shown statistical significant differences. The Ac group had the highest mean to flexural resistance and the least level of released monomer in comparison with others resins. The Qc and Vf1 groups had the worst results for both tests. The initial conclusions showed a cause-effect relation between higher levels of residual monomer and lower flexural strength to this group. Additionally, it was verified that the immersion for 30 minutes of self cured resin in heated water gave an improvement of material quality to evaluated characteristics.
|
2 |
Avaliação da resistência flexural de fibras de vidro e cerâmicas odontológicas utilizadas como subestrutura de próteses parciais fixasSilva, Adriana de Oliveira 27 July 2004 (has links)
Made available in DSpace on 2017-07-24T19:22:27Z (GMT). No. of bitstreams: 1
Adriana de Oliveira Silva.pdf: 854698 bytes, checksum: 0fe1099b901133907165a1d0a216a8e3 (MD5)
Previous issue date: 2004-07-27 / The aim of this study was to evaluate the flexural strength of two fibers glass and two
ceramics systems used like substructure of prosthesis fixed partial using a three point
bending test. Four groups, with ten specimens and dimensions of 25+ 2mm X 2+
0,1mm X 2+ 0,1mm (ISO 10477) to fibers glass and 25+ 5 mm X 4+ 0,25 mm X 1,2+
0,2 mm (ISO 6872) to ceramics were prepared according to the manufacturer’s
instructions, where: GI-Vectris Pontic® (Ivoclar/Vivadent), GII-Fibrex Medial® (Angelus
Soluções Odontológicas), GIII- IPS Empress ®2(Ivoclar/Vivadent) e GIV- VITA In-
Ceram® Zircônia. The specimens were dry stored, in plastic recipient, without light on
room temperature and submitted on three point test at universal machine Instron®
Corp. 2KN(crosshead speed of 0,75mm/min) and the results of the mean values of
flexural strength were 516,04 + 58,44 MPa to GI , 505,23 + 85,57 MPa to GII,
182,73+ 50,33 MPa to the GIII and 442,37 + 99,89 MPa to GIV. The predominance
of failure was incomplete fracture to fibers glass and complete fracture to ceramics.
The results were submitted on statistical analysis, Anova (p<0,05) and there were
observed differences statistically insignificant among the fibers’ group (p=0.7460)
and differences statistically significant among the ceramics’ group. Concluded that
fibers tested presented similar performance of flexural strength and the result
suggested the possibility of fibers glass be used like alternative of alloy in good
indication of clinical situation of prosthesis fixed partial. The ceramics presented not
similar performance of flexural strength being VITA In-Ceram® Zircônia system able
to support more load when compared with IPS Empress® 2 Ivoclar/Vivadent system. / O objetivo deste estudo foi avaliar a resistência flexural de dois sistemas de fibras de
vidro unidirecionais e duas cerâmicas utilizadas como subestrutura de próteses
parciais fixas, através do teste de três pontos. Quatro grupos, com 10 corpos-deprova
cada, e dimensões de 25+2mm X 2+0,1mm X 2+0,1mm (ISO 10477) para as
fibras de vidro e 25+ 5 mm X 4+ 0,25 mm X 1,2+ 0,2 mm (ISO 6872) para as
cerâmicas, foram obtidos seguindo as orientações dos fabricantes, sendo: GIVectris
Pontic® (Ivoclar/Vivadent), GII- Fibrex Medial® (Angelus Soluções
Odontológicas), GIII- IPS Empress ®2(Ivoclar/Vivadent) e GIV- VITA In-Ceram®
Zircônia. Os corpos-de-prova foram armazenados, secos, à temperatura ambiente,
em recipientes plásticos, sem interferência de luz e submetidos ao teste de três
pontos em uma máquina de ensaio Instron® Corp. 2KN (velocidade de 0,75mm/min)
obtendo-se valores médios de resistência à flexão de 516,04 + 58,44 MPa para GI,
505,23 + 85,57 MPa para GII, 182,73+ 50,33MPa para o GIII e 442,37 + 99,89 MPa
para o GIV. O padrão de falha observado foi de fratura incompleta para as fibras de
vidro e fratura completa para as cerâmicas. Os valores médios de resistência foram
submetidos à análise estatística, teste Anova (p<0,05) e verificou-se a inexistência
de diferenças estatísticas significantes entre os grupos de fibras de vidro (p=0.7460)
e a existência de diferenças estatísticas significantes entre os grupos de cerâmicas.
Concluiu-se que as fibras de vidro utilizadas no experimento apresentaram
desempenhos de resistência flexural semelhantes e os resultados sugeriram a
possibilidade da utilização das fibras de vidro como alternativa às ligas metálicas em
situações clínicas bem indicadas de próteses parciais fixas. As cerâmicas
apresentaram diferentes desempenhos de resistência flexural, sendo o sistema VITA
In-Ceram® Zircônia capaz de resistir a maior carga aplicada comparada ao sistema
IPS Empress® 2 Ivoclar/Vivadent.
|
3 |
Influência da composição monomérica e da presença de sal difenil-iodônio nas propriedades mecânicas de resinas experimentais reforçadas com fibras de vidro / Influence of monomeric composition and presence of diphenyl-iodonium salt in the mechanical properties of experimental resines with glass fibersCarvalho, Pedro Ivo de 31 March 2017 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2017-05-03T15:20:09Z
No. of bitstreams: 2
Dissertação - Pedro Ivo de Carvalho - 2017.pdf: 4004894 bytes, checksum: 33f2a48487a0eb9767e85161eae677b4 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-05-03T15:20:21Z (GMT) No. of bitstreams: 2
Dissertação - Pedro Ivo de Carvalho - 2017.pdf: 4004894 bytes, checksum: 33f2a48487a0eb9767e85161eae677b4 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-05-03T15:20:22Z (GMT). No. of bitstreams: 2
Dissertação - Pedro Ivo de Carvalho - 2017.pdf: 4004894 bytes, checksum: 33f2a48487a0eb9767e85161eae677b4 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2017-03-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Several researches aim to discover a best development of new glass-fiber-reinforced
composite resins for the manufacture of intraradicular posts with better mechanical properties
has been the aim of several researches lately. The reinforcement of composite resin with glass
fibers can improve the mechanical properties, such as flexural strength, fracture resistance and
compressive strength. Considering that the resin matrix monomers, the photoinitiator system
and the interaction with the glass fibers interfere in the homogenization of the composite and
in the degree of polymer conversion, the present work had as Objective: To evaluate the
influence of different proportions of the monomers Bis-EMA / Bis-GMA / TEGDMA and
photoactivator systems based on DFI and camphorquinone on the mechanical properties of a
experimental fiberglass reinforced composite resin. Methodology: Ten groups were created
(n = 10) using an experimental resin based on methacrylate, having as study factors: 1.
Different matrices according to the proportions of monomers Bis-GMA (BG), TEGDMA (TE)
and Bis-EMA (BE): And 2. The photoinitiator system: without DFI (SD) salt or DFI (CD) salt.
The samples were prepared for the flexural strength (RF) and diametral tensile strength (RTD)
tests. Statistical analysis showed that for RF (Mpa) there was significance in the interaction
between the factors under study (p = 0.047). The highest result occurred for Group 10
(267.815 ± 45.05) c, followed by Group 9 (242.440 ± 44.83) bc; Group 8 (241.05 ± 44.83) b
Group 3 (236.152 ± 26.42) abc. The lowest result occurred in Group 9 (192.450 ± 12.60) a,
followed by Group 7 (202.35 ± 28.36) ab; Group 6 (207,240 ± 30,07) ab; Group 2 (209.530 ±
23.16) ab; Group 5 (216,760 ± 30,14); And Gruop 1 (218,880 ± 41,49). For RTD only the
presence of DFI salt showed statistical significance (p = 0.001). The addition of the DFI salt
in the composite significantly increased results for flexural strength and diametral tensile
strength, while the increase of Bis-EMA was significant for better flexural strength results. / A busca pelo desenvolvimento de novos compósitos reforçados com fibra de vidro
para a confecção de pinos intrarradiculares com melhores propriedades mecânicas tem sido a
base de várias pesquisas atuais. O incremento fibras de vidro silanizadas nas resinas promove
melhora nos valores de resistência à flexão, resistência à fratura e resistência compressiva.
Tendo em vista que os monômeros da matriz resinosa, o sistema fotoiniciador e a interação
com as fibras de vidro interferem na qualidade do compósito e no grau de conversão
polimérica, o presente trabalho teve como objetivo avaliar as propriedades mecânicas de um
compósito experimental reforçado por fibra de vidro composto por 30% de matriz orgânica,
47,5% de partícula de carga e 22,5% de vibras de vidro curta(3mm), variando proporções de
monômeros Bis-EMA, Bis-GMA e TEGDMA e o efeito do sal de difenil-iodônio (DFI) em um
sistema fotoiniciador à base de canforoquinona. Dez grupos foram criados (n=10) utilizando
uma resina experimental a base de metacrilato, tendo como fatores em estudo: 1. Diferentes
matrizes de acordo com as proporções dos monômeros Bis-GMA, TEGDMA e Bis-EMA e 2.
O sistema fotoiniciador: sem sal DFI (SD) ou com sal DFI (CD). As amostras foram
preparadas para os testes resistência flexural (RF) e resistência à tração diametral (RTD).
Análise estatística mostrou que para RF (Mpa) houve significância na interação entre os
fatores em estudo (p=0,047). Os melhores resultados foram encontrados para os grupos: Grupo
10 (267,815±45,05)c, seguido por Grupo 9 (242,440±44,83)bc. Para RTD somente a presença
do sal DFI demonstrou significância estatística (p=0,001). Em MPa foram observados os
maiores resultados: Grupo 10, (35,36±2,61b); Grupo 8, (35,07±6,89b). A adição do sal DFI no
compósito aumentou significativamente resultados para resistência flexural e resistência à
tração diametral, enquanto que a presença de Bis-EMA foi significante para melhores
resultados somente em resistência flexural.
|
4 |
"Estudo das resinas acrílicas para bases de próteses totais com relação à resistência flexural, e à quantidade de monômero residual superficial" / Study of acrylic resin for complete denture considering flexural strength and quantity of superficial residual mono merTarcisio José de Arruda Paes Junior 16 June 2005 (has links)
O objetivo deste trabalho foi o de avaliar a resistência à flexão e a quantidade de monômero residual superficial em resinas acrílicas para bases de próteses totais. Para tanto foram confeccionados corpos-de-prova nas dimensões de 2.5mm x 10mm x 65mm, utilizados em ambas as análises. Padronizou-se o processo de inclusão no qual foram empregadas muflas plásticas reforçadas por fibras de vidro. Sete grupos foram constituídos, de acordo com o tipo de processamento empregado na polimerização das resinas: Ac (Acron-MC) e Vw (Vipi-Wave) de ativação por energia de microondas; Lt (Lucitone 550 grupo controle) e Vc (Vipi-Cril), resinas de ativação térmica convencional em banho de água aquecida no ciclo longo; Qc (QC-20), uma resina de ativação térmica em ciclo rápido e, dois grupos cuja resina era a mesma de ativação química (Vipi-Flash), processada em duas condições à temperatura ambiente (Vf1) e, por aquecimento adicional em banho de água (Vf2). Os resultados mostraram diferenças estatisticamente significantes, onde o grupo Ac obteve as maiores médias para resistência flexural e os menores níveis de monômero liberado em relação às demais resinas. Os grupos Qc e Vf1 evidenciaram os piores resultados para ambos os testes, e a princípio, pareceu haver uma relação de causa e efeito entre, os elevados níveis de monômero residual encontrado nestes grupos, e a baixa resistência flexural observada. Verificou-se ainda que a imersão em água aquecida por 30min, da resina de ativação química, propiciou um ganho em qualidade do material para as características avaliadas. / The purpose of this work was the evaluation of flexural strength and quantity of superficial residual monomer in acrylic resin for complete denture. To perform both analyses it was developed specimens with a dimension of 2.5mm x 10mm x 65mm. The inclusion process was standardized by the use of plastic flasks reinforced with fiberglass. Seven groups were constituted in accordance with the type of resin polymerization process: Ac (Acron-MC) and Vw (Vipi-Wave) activated by microwave energy; Lt (Lucitone 550 control group) and Vc (Vipi-Cril), conventional water bath curing cycles of heat activated acrylic resin; Qc (QC-20), fast cycle thermal activation; and two groups of self cured resin (Vipi-Flash), processed in two distinguished conditions: ambient temperature (Vf1) and additional heating in water bath (Vf2). The results have shown statistical significant differences. The Ac group had the highest mean to flexural resistance and the least level of released monomer in comparison with others resins. The Qc and Vf1 groups had the worst results for both tests. The initial conclusions showed a cause-effect relation between higher levels of residual monomer and lower flexural strength to this group. Additionally, it was verified that the immersion for 30 minutes of self cured resin in heated water gave an improvement of material quality to evaluated characteristics.
|
5 |
Sorção, solubilidade e resistência flexural biaxial de uma resina composta em função do tipo de fonte de luz e técnicas de polimerização / Sorption, solubility and biaxial flexural strength of a composite resin according to the type of light source and curing techniquesCarvalho, Andreia Assis 18 February 2010 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2014-08-12T13:22:56Z
No. of bitstreams: 1
dissertacao andreia assis carvalho.pdf: 1800077 bytes, checksum: 9621151283f1dec9c48115c5ac9df906 (MD5) / Made available in DSpace on 2014-08-12T13:22:56Z (GMT). No. of bitstreams: 1
dissertacao andreia assis carvalho.pdf: 1800077 bytes, checksum: 9621151283f1dec9c48115c5ac9df906 (MD5)
Previous issue date: 2010-02-18 / The use of composite resin (CR) in dental restorations is a common practice, however, in the oral environment, these polymers are subject to hygroscopic and hydrolytic effects, and strength of occlusion and mastication. This study aimed to evaluate in vitro the influence of different light sources, energy densities and polymerization techniques on sorption, solubility and biaxial flexural strength (RFB) of an RC. 240 specimens were fabricated (2mm x 8 MMO) RC (Esthet-X), shade A2. Two groups were obtained, depending on the instrument used: halogen lamp and light emitting diodes (LED) and subdivided according to the energy density (16 J/cm2 and 20 J/cm2), polymerization (conventional pulse I stopped and interrupted pulse II) and type of permeant (water and ethanol 75%). The methodology for the development of sorption and solubility test was based on ISO 4049:2000. Then the specimens were tested for RFB (ASTM F 394-78). We used ANOVA and Tukey test for parametric data and Kruskal-Wallis and Mann-Whitney test for data nãoparamétricos (? = 0.05). It was observed that in general there was no statistically significant differences when comparing the sources of light and the polymerization techniques (p> 0.05). Energy density of 16 J/cm2 and pulse interrupted technique II was possible to observe that the LED generated higher values of sorption and solubility of the halogen light and, in the conventional technique, lower RFB (p> 0.05 ). The ethanol produced higher values of sorption and solubility, and lower RFB compared with water. In general, light sources, energy densities and polymerization techniques did not influence the values of sorption, solubility and RFB / O uso de resina composta (RC) em restaurações odontológicas são uma prática frequente, entretanto, no meio bucal, esses polímeros estão sujeitos a efeitos higroscópicos e hidrolíticos, além de forçaa da oclusão e mastigação. Este trabalho teve como objetivo avaliar, in vitro, a influência de diferentes fontes de luz, densidades de energia e técnicas de polimerização na sorção, solubilidade e resistência flexural biaxial (RFB) de uma RC. Foram confeccionados 240 espécimes (2mm x 8 mmØ) de RC (Esthet-X), cor A2. Dois grupos foram obtidos, em função do aparelho utilizado: lâmpada halógena e luz emitida por diodo (LED); e subdivididos de acordo com a densidade de energia (16 J/cm2 e 20 J/cm2), técnica de polimerização (convencional, pulso interrompido I e pulso interrompido II) e tipo de permeante (água deionizada e etanol 75%). A metodologia utilizada para o desenvolvimento do teste de sorção e solubilidade foi baseada na ISO 4049:2000. Em seguida, os espécimes foram testados quanto à RFB (ASTM F 394-78). Foram utilizados os testes ANOVA e Tukey para os dados paramâtricos e os testes Kruskal-Wallis e Mann-Whitney para os dados não paramétricos ( =0,05). Foi observado que, em geral, não houve diferenças estatisticamente significantes quando comparados as fontes de luz e as técnicas de polimerização (p>0,05). Na densidade de energia de 16 J/cm2 e na técnica por pulso interrompido II foi possível observar que o LED gerou maiores valores de sorção e solubilidade do que a lâmpada halógena e, na técnica convencional, menores valores de RFB (p>0,05). O etanol gerou maiores valores de sorção e solubilidade, e menores de RFB quando comparado com a água. Em geral, as fontes de luz, densidades de energia e técnicas de polimerização não influenciaram nos valores de
soção, solubilidade e RFB
|
6 |
Efeito da adição de fibras de vidro particuladas nas propriedades mecânicas de resinas acrílicas utilizadas para a confecção de placas oclusais / Effect of addition of the particulate glass fibers in mechanical properties of acrylic resins used for the making occlusal splintsSoares, Rodrigo Gonçalves 06 July 2010 (has links)
Placas oclusais são dispositivos intraorais utilizados no manejo de pacientes que apresentam desordens do sono, migrânia do tipo tensional e outros. No entanto são os cirurgiões dentistas que predominantemente utilizam as placas oclusais como tratamento do equilíbrio das arcadas dentárias nas disfunções temporomandibulares, prevenção de desgaste dental em pacientes com hábitos parafuncionais e na prevenção de traumas em atletas. Vários métodos têm sido empregados para reforçar resinas acrílicas, como reforço metálico e atualmente a incorporação de diferentes tipos de fibras tais como: carbono, polietileno e vidro. Contudo a adição de fibras de vidro com partículas menores em algumas propriedades mecânicas ainda permanecem desconhecidas. Objetivo: O objetivo desse estudo foi avaliar algumas propriedades mecânicas como a rugosidade de superfície, microdureza, módulo de elasticidade e resistência flexural em resinas acrílicas após a incorporação de fibras de vidro particuladas pré silanizadas. Material e método: Para avaliação das propriedades foram confeccionados vinte e quatro corpos de prova (65 x 10 x 3 mm) de cada marca comercial de resina acrílica, utilizadas para confecção de placas oclusais, Vipi Flash (autopolimerizável), Vipi Wave (termopolimerizável por calor de microondas), Vipi Crill, Lucitone e QC-20 (termopolimerizáveis por calor de banho de água), sendo doze corpos-de-prova controles, e doze experimentais, com adição de 10% em peso de fibras de vidro particuladas (Reforplás S/A, São Paulo, SP, Brasil). Após a realização do acabamento superficial dos corpos de prova com lixas de carborundum e feltros era realizada a avaliação da rugosidade superficial em rugosímetro (Mitutoyo®) com três leituras ao longo dos corpos-de-prova, a microdureza Vickers era analisada em um microdurômetro (Micro Hardness Tester, Shimadzu, Japan) com cinco mensurações em cada corpo-de-prova, e para avaliar os ensaios de resistência flexural e módulo de elasticidade os corpos-de-prova foram avaliados por meio uma máquina de ensaios universal (Emic DL 2000®, Emic, São José dos Pinhais, PR, Brasil), com velocidade de 5mm/min. Os dados foram analisados estatisticamente, usando testes paramétricos e não paramétricos, de acordo com a distribuição da amostra. Resultados: As médias e desvios padrões do teste de rugosidade superficial em Ra foram Vipi Flash sem fibra (0,10 ± 0,03); Vipi Flash com fibra (0,12 ± 0,01); Vipi Wave sem fibra (0,16 ± 0,02); Vipi Wave com fibra (0,13 ± 0,02); Vipi Cril sem fibra (0,12 ± 0,03); Vipi Crill com fibra (0,15 ± 0,03); Lucitone sem fibra (0,10 ± 0,02); Lucitone com fibra (0,09 ± 0,04); QC-20 sem fibra (0,11 ± 0,02) e QC-20 com fibra (0,18 ± 0,03). As médias e desvios-padrão ao teste de microdureza Knoop com relação às marcas comerciais foram: Vipi Flash sem fibra (15,35 ± 0,3); Vipi Flash com fibra (15,51 ± 0,4); Vipi Wave sem fibra (16,60 ± 0,8); Vipi Wave com fibra (17,25 ± 0,9); Vipi Cril sem fibra (17,78 ± 2,27); Vipi Crill com fibra (18,02 ± 1,0); Lucitone sem fibra (15,72 ± 0,3); Lucitone com fibra (16,69 ± 0,6); QC-20 sem fibra (15,91 ± 0,4) e QC-20 com fibra (15,63 ± 0,2). As médias e desvios-padrão ao teste de módulo de elasticidade foram: Vipi Flash sem fibra (2952,76 ± 292,12); Vipi Flash com fibra (3373,49 ± 403,76); Vipi Wave sem fibra (2511,69 ± 304,09); Vipi Wave com fibra (3225,01 ± 248,66); Vipi Cril sem fibra (2745,61± 288,86); Vipi Crill com fibra (3671,67 ± 329,91); Lucitone sem fibra (1904,53 ± 149,05); Lucitone com fibra (3056,87 ± 126,11); QC-20 sem fibra (1913,86 ± 147,80) e QC-20 com fibra (2858,32 ± 185,26). As médias e desvios-padrão ao teste de resistência flexural foram Vipi Flash sem fibra (81,62 ± 4,82); Vipi Flash com fibra (83,98 ± 4,98); Vipi Wave sem fibra (83,52 ± 8,79); Vipi Wave com fibra (88,98± 8,47); Vipi Cril sem fibra (64,17± 5,46); Vipi Crill com fibra (93,37 ± 9,97); Lucitone sem fibra (74,71± 9,43); Lucitone com fibra (87,29 ± 4,73); QC-20 sem fibra (75,80 ± 8,82) e QC-20 com fibra (81,67± 12,97). Conclusão: Conclui-se que a incorporação de fibras provocou alterações em praticamente todas as propriedades analisadas, sendo, portanto facilmente utilizável como um reforço adicional às resinas acrílicas. Com relação à dureza superficial as resinas acrílicas termopolimerizável por banho de água e termopolimerizável por calor de microondas apresentaram maiores valores quando comparados com a resina acrílica autopolimerizável. Além disso, a adição de fibras de vidro particuladas aumentou os valores de rugosidade de algumas resinas acrílicas Vipi Crill, Vipi Flash e Vipi Wave e se manteve constante nas resinas Lucitone e QC-20. A adição de fibra de vidro não aumentou significantemente a microdureza Knoop nos grupos em estudo. Com relação à resistência flexural as fibras de vidro particuladas aumentaram significantemente todos os valores, assim como o módulo de elasticidade das resinas acrílicas reforçadas pela adição de fibras de vidro. / Intraoral Occlusal splints are devices used in the management of patients with sleep disorders, migraine type tension and others. But dentists who are predominantly using the plates as a treatment of occlusal balance of the dental arches in temporomandibular disorders, prevention of tooth wear in patients with habits and prevention of injuries in athletes. Several methods have been used to strengthen acrylic resins, such as metal reinforcement and are currently incorporating different types of fibers such as carbon, polyethylene and glass. However the addition of glass fibers with smaller particles on mechanical properties are still unknown. Objective: The objective of this study was to evaluate some mechanical properties such as surface roughness, hardness, elastic modulus and flexural strength in acrylic resins after the incorporation of glass fiber particulate pre silanized. Methods: To evaluate the properties were made twenty-four specimens (65 x 10 x 3 mm) of each brand of acrylic resin, used for fabrication of occlusal splints, Vipi Flash (self-curing), Vipi Wave (by thermo microwave heat), Vipi CRILL, Lucitone and QC-20 (thermo heat water bath), with twelve specimes controls, and twelve experimental, with the addition of 10 wt% glass fiber particulate (Reforplás S / A, São Paulo, Brazil). After completion of the roughness of the specimens with grit carborundum and felt it was evaluated the surface roughness on roughness tester (Mitutoyo ®) with three readings over the specimes, the microhardness was examined with a hardness ( Micro Hardness Tester, Shimadzu, Japan) with five measurements in each specime, and evaluate the tests for flexural strength and modulus of elasticity of the specimes was evaluated using a universal testing machine (Emic DL 2000 ®, Emic, São José dos Pinhais, PR, Brazil), with speed 5mm/min. The data were statistically analyzed using parametric and nonparametric tests, according to the sample distribution. Results: The mean and standard deviation of the test surface roughness were Vipi Flash without fiber (0.10 ± 0.03); Flash Vipi with fiber (0.12 ± 0.01); Vipi Wave without fiber (0, 16 ± 0.02); Vipi Wave with fiber (0.13 ± 0.02); Vipi Cril without fiber (0.12 ± 0.03); Vipi CRILL with fiber (0.15 ± 0.03); Lucitone without fiber (0.10 ± 0.02); Lucitone with fiber (0.09 ± 0.04), QC-20 fiber without (0.11 ± 0.02) and QC-20 with fiber (0.18 ± 0.03). Means and standard deviations for Knoop microhardness test with respect to trademarks were Vipi Flash without fiber (15.35 ± 0.3); Flash Vipi with fiber (15.51 ± 0.4); Vipi Wave without fiber (16.60 ± 0.8); Vipi Wave with fiber (17.25 ± 0.9); Vipi Cril without fiber (17.78 ± 2.27); Vipi CRILL with fiber (18.02 ± 1.0 ); Lucitone without fiber (15.72 ± 0.3); Lucitone with fiber (16.69 ± 0.6), QC-20 without fiber (15.91 ± 0.4) and QC-20 with fiber (15 , 63 ± 0.2). Means and standard deviations to test elastic modulus were Vipi Flash without fiber (2952.76 ± 292.12); Flash Vipi with fiber (3373.49 ± 403.76); Vipi Wave without fiber (2511.69 ± 304.09); Vipi Wave with fiber (3225.01 ± 248.66); Vipi Cril without fiber (2745.61 ± 288.86); Vipi CRILL with fiber (3671.67 ± 329.91); Lucitone without fiber (1904.53 ± 149.05); Lucitone with fiber (3056.87 ± 126.11), QC-20 without fiber (1913.86 ± 147.80) and QC-20 with fiber (2858.32 ± 185 26). Means and standard deviations for flexural strength were Vipi Flash without fiber (81.62 ± 4.82); Flash Vipi with fiber (83.98 ± 4.98); Vipi Wave without fiber (83.52 ± 8 , 79); Vipi Wave with fiber (88.98 ± 8.47); Vipi Cril without fiber (64.17 ± 5.46); Vipi CRILL with fiber (93.37 ± 9.97); Lucitone without fiber ( 74.71 ± 9.43); Lucitone with fiber (87.29 ± 4.73), QC-20 without fiber (75.80 ± 8.82) and QC-20 with fiber (81.67 ± 12.97). Conclusion: the conclusion is that the incorporation of fibers resulted in changes in almost all properties examined, and thus easily used as an additional reinforcement for acrylic resins. With respect to the surface roughness of acrylic resins by thermo water bath and microwave thermo heat showed higher values when compared with acrylic resin. Moreover, the addition of glass fiber particulate increased the roughness values of some acrylic resins Vipi CRILL, Vipi Flash and Vipi Wave and remained constant in the resins Lucitone and QC-20. The addition of glass fiber does not increase significantly the microhardness in the groups. With respect to flexural strength glass fiber particulate significantly increased all values, as well as the modulus of acrylic resin reinforced by the addition of glass fibers.
|
7 |
Polimerização com laser de argônio: influência na tensão de contração, microdureza, resistência flexural e módulo de elasticidade de uma resina composta / Polymerization with the argon laser: Influence on shrinkage stress microhardness, percentage of maximum hardness, flexural strength and flexural modulus of a composite resinDelfino, Carina Sinclér 19 September 2008 (has links)
O objetivo desse estudo foi verificar a influência da fotoativação com laser de argônio na tensão de contração (TC), microdureza (M), porcentagem de dureza máxima (PDM), resistência flexural (RF) e módulo de elasticidade (ME) de uma resina composta híbrida. A fotoativação foi realizada com laser de argônio 200mW por 10 segundos (L1), 200mW por 20 segundos (L2), 250mW por 10 segundos (L3) e 250mW por 20 segundos (L4). Como controle foi utilizada a luz hálógena por 20 segundos (H). A TC foi monitorada por 5 minutos em corpos-de-prova com 5mm de diâmetro e 1mm de altura. A M e a PDM foram obtidas em corpos-de-prova com 2mm de espessura após 7 dias a 37°C. Para obtenção da RF e do ME foram confeccionados corpos-de-prova nas dimensões 10 X 2 X 1mm (comprimento, largura e espessura), testados após 24h a 37°C. Os dados obtidos foram analisados por ANOVA/Teste de Tukey (p<0,05). Os valores de TC (MPa) foram estatisticamente mais baixos para o grupo L3 (1,3)c, seguido pelos grupos L1(2,7)b, L4 (3,4)a,b, L2 (3,7)a e H (4,5)a. Para os valores de M não houve diferença estatisticamente significante quando o mesmo tempo de fotoativação foi utilizado, sendo L1= 70,1a, L2= 78,1b, L3= 69,9a, L4= 78,1b e H= 79,9b. Todos os grupos apresentaram uma PDM de no mínimo 80%. Apenas o grupo L1 apresentou diferença estatisticamente significante na RF (MPa) e no ME (GPa), 86,2 e 5,4 respectivamente, sendo inferior. Dentro dos grupos estudados, o L3 apresentou propriedades mecânicas adequadas e mínima tensão de contração, além de possibilitar redução do tempo clínico para fotoativação de restaurações com a resina testada em 50%. / The objective of this study was to verify the influence of photoactivation with the argon ion laser on shrinkage stress (SS), followed by evaluation of Vickers microhardness (VM), percentage of maximum hardness (PMH), flexural strength (FS) and flexural modulus (FM) of a composite resin. Methods: The light curing units used were argon ion laser and halogen light. The groups were: L1- laser at 200mW for 10 seconds; L2- laser at 200mW for 20 seconds; L3- laser at 250mW for 10 seconds; L4- laser at 250mW for 20 seconds; and H- halogen light at 275mW for 20 seconds. The SS was monitored for 5 minutes in samples 5-mm in diameter by 1-mm in height. The VM and PHM were obtained in samples with a thickness of 2-mm after 7 days at 37°C. To FS and FM the samples were prepared using a stainless steel mold 10 x 2 x 1mm (length, width and height) and measured after 24h storage at 37°C. Data were analyzed by ANOVA/Tukey`s test (p<0.05). Results: The values of SS (MPa) were statistically lower for the group L3(1.3)c, followed by groups L1(2.7)b, L4 (3.4)a,b, L2(3.7)a and H(4.5)a. To the values of VM there was no difference when the same time of photo activation was used, being L1= 70.1a, L2=78.1b, L3= 69.9a, L4= 78.1b and H= 79.9b. All groups showed a PMH of at least 80%. Only the group L1 showed difference in FS (MPa) and FM (GPa), 86.2 and 5.4 respectively, being lower. Conclusion: within the studied groups, the L3 group presented adequate mechanical properties and minimum SS, reducing the clinical working time for photo activation of restorations with the tested resin in 50%.
|
8 |
Influência de substâncias irrigadoras endodônticas nas propriedades mecânicas da dentina radicularQueiroz, Ellyne Cavalcanti 13 March 2007 (has links)
The aim of this study was to evaluate the influence of different
endodontic irrigants on the cohesive and flexural strength of the root dentin.
One hundred of bovine incisor roots were selected, instrumented and randomly
divided into 10 experimental groups (n = 10), according to the irrigation solution
used: Control - physiological solution; N1 - sodium hypochlorite 1.0%; N5 -
sodium hypochlorite 5.25%; N1EDTA - sodium hypochlorite 1.0% associate to
EDTA 17%; N5EDTA - sodium hypochlorite 5.25% associate to EDTA 17%;
Sclx chlorhexidine gluconate solution 2.0%; Gclx - chlorhexidine gluconate gel
2.0%; SclxEDTA - chlorhexidine gluconate solution 2.0% associate to EDTA
17%; GclxEDTA - chlorhexidine gluconate gel 2.0% associate to EDTA 17%
and EDTA - EDTA 17%. The roots were axially sectioned in two halves. Half of
them were used for the microtensile cohesive strength test: six 1.0mm thick
slices were trimmed to produce hourglass shaped samples with a test area of
1mm2. The other halves were used in a 3-point bend flexural strength by means
of dentine bars with 1X1X12 mm. Each sample remained two hours in contact
with the irrigant solutions, except for EDTA, which remained for five minutes.
After irrigants treatment, samples were rinsed with distilled water, and tested.
Specific devices for each test were used, in a universal testing machine with a
load cell of 20Kgf, and a crosshead speed of 0.5 mm/minute. Date were
recorded and statistically analyzed with one-way ANOVA and Tukey test.
Significant reduction in the ultimate cohesive strength and flexural strength was
verified only for the groups that used sodium hypochlorite irrespective of the
concentration and additional solution, differing significant from the group control.
The use of chlorhexidine and EDTA separately did not cause alteration in the
mechanical properties of root dentine. / O objetivo desse estudo foi avaliar a influência de diferentes
irrigantes endodônticos na resistência coesiva e flexural da dentina radicular.
Cem raízes de incisivos bovinos foram selecionadas, instrumentadas e
divididas aleatoriamente em 10 grupos experimentais (n= 10), de acordo com a
substância irrigadora utilizada: Controle - solução fisiológica; N1 - hipoclorito de
sódio a 1,0%; N5 - hipoclorito de sódio a 5,25% ; N1EDTA - hipoclorito de sódio
a 1,0% associado à EDTA a 17%; N5EDTA - hipoclorito de sódio a 5,25%
associado à EDTA a 17%; Sclx - solução de gluconato de clorexidina a 2,0%;
Gclx - gel de gluconato clorexidina a 2,0%; SclxEDTA - solução de gluconato
clorexidina 2,0% associado à EDTA a 17%; GclxEDTA - gel de gluconato
clorexidina a 2,0% associado à EDTA a 17% e EDTA - EDTA a 17%. As raízes
foram axialmente seccionadas em duas metades. Uma metade foi utilizada
para ensaio de microtração, da qual foram obtidas seis fatias de 1,0mm de
espessura que receberam constrições na face externa, determinando área de
teste de 1mm2. A outra metade foi utilizada no ensaio de flexão de 3-pontos, da
qual foi extraída uma barra de dentina com dimensões de 1X1X12 mm. Cada
amostra permaneceu duas horas em contato com a substância irrigante
endodôntica com exceção do EDTA, que atuou por cinco minutos. Após o
tratamento com os irrigantes, procedeu-se a lavagem com água destilada, e em
seguida executados os ensaios mecânicos. Foram utilizados dispositivos
específicos para cada ensaio, acoplados à máquina de ensaio mecânico,
utilizando célula de carga de 20Kgf, com velocidade de 0,5 mm/minuto até a
fratura da amostra. Os dados obtidos foram submetidos à análise de variância
e teste Tukey. Verificou-se redução significativa na resistência máxima coesiva
e flexural apenas para os grupos que empregaram o hipoclorito de sódio
independe da concentração e associação com outra substância, diferindo
estatisticamente do grupo controle. O uso de clorexidina e EDTA isoladamente
não alterou as propriedades mecânicas da dentina radicular. / Mestre em Odontologia
|
9 |
Efeito da adição de fibras de vidro particuladas nas propriedades mecânicas de resinas acrílicas utilizadas para a confecção de placas oclusais / Effect of addition of the particulate glass fibers in mechanical properties of acrylic resins used for the making occlusal splintsRodrigo Gonçalves Soares 06 July 2010 (has links)
Placas oclusais são dispositivos intraorais utilizados no manejo de pacientes que apresentam desordens do sono, migrânia do tipo tensional e outros. No entanto são os cirurgiões dentistas que predominantemente utilizam as placas oclusais como tratamento do equilíbrio das arcadas dentárias nas disfunções temporomandibulares, prevenção de desgaste dental em pacientes com hábitos parafuncionais e na prevenção de traumas em atletas. Vários métodos têm sido empregados para reforçar resinas acrílicas, como reforço metálico e atualmente a incorporação de diferentes tipos de fibras tais como: carbono, polietileno e vidro. Contudo a adição de fibras de vidro com partículas menores em algumas propriedades mecânicas ainda permanecem desconhecidas. Objetivo: O objetivo desse estudo foi avaliar algumas propriedades mecânicas como a rugosidade de superfície, microdureza, módulo de elasticidade e resistência flexural em resinas acrílicas após a incorporação de fibras de vidro particuladas pré silanizadas. Material e método: Para avaliação das propriedades foram confeccionados vinte e quatro corpos de prova (65 x 10 x 3 mm) de cada marca comercial de resina acrílica, utilizadas para confecção de placas oclusais, Vipi Flash (autopolimerizável), Vipi Wave (termopolimerizável por calor de microondas), Vipi Crill, Lucitone e QC-20 (termopolimerizáveis por calor de banho de água), sendo doze corpos-de-prova controles, e doze experimentais, com adição de 10% em peso de fibras de vidro particuladas (Reforplás S/A, São Paulo, SP, Brasil). Após a realização do acabamento superficial dos corpos de prova com lixas de carborundum e feltros era realizada a avaliação da rugosidade superficial em rugosímetro (Mitutoyo®) com três leituras ao longo dos corpos-de-prova, a microdureza Vickers era analisada em um microdurômetro (Micro Hardness Tester, Shimadzu, Japan) com cinco mensurações em cada corpo-de-prova, e para avaliar os ensaios de resistência flexural e módulo de elasticidade os corpos-de-prova foram avaliados por meio uma máquina de ensaios universal (Emic DL 2000®, Emic, São José dos Pinhais, PR, Brasil), com velocidade de 5mm/min. Os dados foram analisados estatisticamente, usando testes paramétricos e não paramétricos, de acordo com a distribuição da amostra. Resultados: As médias e desvios padrões do teste de rugosidade superficial em Ra foram Vipi Flash sem fibra (0,10 ± 0,03); Vipi Flash com fibra (0,12 ± 0,01); Vipi Wave sem fibra (0,16 ± 0,02); Vipi Wave com fibra (0,13 ± 0,02); Vipi Cril sem fibra (0,12 ± 0,03); Vipi Crill com fibra (0,15 ± 0,03); Lucitone sem fibra (0,10 ± 0,02); Lucitone com fibra (0,09 ± 0,04); QC-20 sem fibra (0,11 ± 0,02) e QC-20 com fibra (0,18 ± 0,03). As médias e desvios-padrão ao teste de microdureza Knoop com relação às marcas comerciais foram: Vipi Flash sem fibra (15,35 ± 0,3); Vipi Flash com fibra (15,51 ± 0,4); Vipi Wave sem fibra (16,60 ± 0,8); Vipi Wave com fibra (17,25 ± 0,9); Vipi Cril sem fibra (17,78 ± 2,27); Vipi Crill com fibra (18,02 ± 1,0); Lucitone sem fibra (15,72 ± 0,3); Lucitone com fibra (16,69 ± 0,6); QC-20 sem fibra (15,91 ± 0,4) e QC-20 com fibra (15,63 ± 0,2). As médias e desvios-padrão ao teste de módulo de elasticidade foram: Vipi Flash sem fibra (2952,76 ± 292,12); Vipi Flash com fibra (3373,49 ± 403,76); Vipi Wave sem fibra (2511,69 ± 304,09); Vipi Wave com fibra (3225,01 ± 248,66); Vipi Cril sem fibra (2745,61± 288,86); Vipi Crill com fibra (3671,67 ± 329,91); Lucitone sem fibra (1904,53 ± 149,05); Lucitone com fibra (3056,87 ± 126,11); QC-20 sem fibra (1913,86 ± 147,80) e QC-20 com fibra (2858,32 ± 185,26). As médias e desvios-padrão ao teste de resistência flexural foram Vipi Flash sem fibra (81,62 ± 4,82); Vipi Flash com fibra (83,98 ± 4,98); Vipi Wave sem fibra (83,52 ± 8,79); Vipi Wave com fibra (88,98± 8,47); Vipi Cril sem fibra (64,17± 5,46); Vipi Crill com fibra (93,37 ± 9,97); Lucitone sem fibra (74,71± 9,43); Lucitone com fibra (87,29 ± 4,73); QC-20 sem fibra (75,80 ± 8,82) e QC-20 com fibra (81,67± 12,97). Conclusão: Conclui-se que a incorporação de fibras provocou alterações em praticamente todas as propriedades analisadas, sendo, portanto facilmente utilizável como um reforço adicional às resinas acrílicas. Com relação à dureza superficial as resinas acrílicas termopolimerizável por banho de água e termopolimerizável por calor de microondas apresentaram maiores valores quando comparados com a resina acrílica autopolimerizável. Além disso, a adição de fibras de vidro particuladas aumentou os valores de rugosidade de algumas resinas acrílicas Vipi Crill, Vipi Flash e Vipi Wave e se manteve constante nas resinas Lucitone e QC-20. A adição de fibra de vidro não aumentou significantemente a microdureza Knoop nos grupos em estudo. Com relação à resistência flexural as fibras de vidro particuladas aumentaram significantemente todos os valores, assim como o módulo de elasticidade das resinas acrílicas reforçadas pela adição de fibras de vidro. / Intraoral Occlusal splints are devices used in the management of patients with sleep disorders, migraine type tension and others. But dentists who are predominantly using the plates as a treatment of occlusal balance of the dental arches in temporomandibular disorders, prevention of tooth wear in patients with habits and prevention of injuries in athletes. Several methods have been used to strengthen acrylic resins, such as metal reinforcement and are currently incorporating different types of fibers such as carbon, polyethylene and glass. However the addition of glass fibers with smaller particles on mechanical properties are still unknown. Objective: The objective of this study was to evaluate some mechanical properties such as surface roughness, hardness, elastic modulus and flexural strength in acrylic resins after the incorporation of glass fiber particulate pre silanized. Methods: To evaluate the properties were made twenty-four specimens (65 x 10 x 3 mm) of each brand of acrylic resin, used for fabrication of occlusal splints, Vipi Flash (self-curing), Vipi Wave (by thermo microwave heat), Vipi CRILL, Lucitone and QC-20 (thermo heat water bath), with twelve specimes controls, and twelve experimental, with the addition of 10 wt% glass fiber particulate (Reforplás S / A, São Paulo, Brazil). After completion of the roughness of the specimens with grit carborundum and felt it was evaluated the surface roughness on roughness tester (Mitutoyo ®) with three readings over the specimes, the microhardness was examined with a hardness ( Micro Hardness Tester, Shimadzu, Japan) with five measurements in each specime, and evaluate the tests for flexural strength and modulus of elasticity of the specimes was evaluated using a universal testing machine (Emic DL 2000 ®, Emic, São José dos Pinhais, PR, Brazil), with speed 5mm/min. The data were statistically analyzed using parametric and nonparametric tests, according to the sample distribution. Results: The mean and standard deviation of the test surface roughness were Vipi Flash without fiber (0.10 ± 0.03); Flash Vipi with fiber (0.12 ± 0.01); Vipi Wave without fiber (0, 16 ± 0.02); Vipi Wave with fiber (0.13 ± 0.02); Vipi Cril without fiber (0.12 ± 0.03); Vipi CRILL with fiber (0.15 ± 0.03); Lucitone without fiber (0.10 ± 0.02); Lucitone with fiber (0.09 ± 0.04), QC-20 fiber without (0.11 ± 0.02) and QC-20 with fiber (0.18 ± 0.03). Means and standard deviations for Knoop microhardness test with respect to trademarks were Vipi Flash without fiber (15.35 ± 0.3); Flash Vipi with fiber (15.51 ± 0.4); Vipi Wave without fiber (16.60 ± 0.8); Vipi Wave with fiber (17.25 ± 0.9); Vipi Cril without fiber (17.78 ± 2.27); Vipi CRILL with fiber (18.02 ± 1.0 ); Lucitone without fiber (15.72 ± 0.3); Lucitone with fiber (16.69 ± 0.6), QC-20 without fiber (15.91 ± 0.4) and QC-20 with fiber (15 , 63 ± 0.2). Means and standard deviations to test elastic modulus were Vipi Flash without fiber (2952.76 ± 292.12); Flash Vipi with fiber (3373.49 ± 403.76); Vipi Wave without fiber (2511.69 ± 304.09); Vipi Wave with fiber (3225.01 ± 248.66); Vipi Cril without fiber (2745.61 ± 288.86); Vipi CRILL with fiber (3671.67 ± 329.91); Lucitone without fiber (1904.53 ± 149.05); Lucitone with fiber (3056.87 ± 126.11), QC-20 without fiber (1913.86 ± 147.80) and QC-20 with fiber (2858.32 ± 185 26). Means and standard deviations for flexural strength were Vipi Flash without fiber (81.62 ± 4.82); Flash Vipi with fiber (83.98 ± 4.98); Vipi Wave without fiber (83.52 ± 8 , 79); Vipi Wave with fiber (88.98 ± 8.47); Vipi Cril without fiber (64.17 ± 5.46); Vipi CRILL with fiber (93.37 ± 9.97); Lucitone without fiber ( 74.71 ± 9.43); Lucitone with fiber (87.29 ± 4.73), QC-20 without fiber (75.80 ± 8.82) and QC-20 with fiber (81.67 ± 12.97). Conclusion: the conclusion is that the incorporation of fibers resulted in changes in almost all properties examined, and thus easily used as an additional reinforcement for acrylic resins. With respect to the surface roughness of acrylic resins by thermo water bath and microwave thermo heat showed higher values when compared with acrylic resin. Moreover, the addition of glass fiber particulate increased the roughness values of some acrylic resins Vipi CRILL, Vipi Flash and Vipi Wave and remained constant in the resins Lucitone and QC-20. The addition of glass fiber does not increase significantly the microhardness in the groups. With respect to flexural strength glass fiber particulate significantly increased all values, as well as the modulus of acrylic resin reinforced by the addition of glass fibers.
|
10 |
EFEITO DE TRATAMENTOS TÉRMICOS NA RESISTÊNCIA FLEXURAL DE UMA VITROCERÂMICA REFORÇADA POR LEUCITA / EFFECT OF HEAT TREATMENTS ON FLEXURAL STRENGHT OF A LEUCITE REINFORCED GLASS CERAMICAurelio, Iana Lamadrid 06 June 2014 (has links)
Fundação de Amparo a Pesquisa no Estado do Rio Grande do Sul / The aim of this study was to investigate the effect of heat treatments on the flexural
strength, surface roughness and crystalline structure of a leucite reinforced glass
ceramic (IPS Empress CAD, Ivoclar Vivadent, Liechtenstein). A hundred fifty (150)
discs were machined by CEREC inLab MC XL (Sirona, Alemanha) and distributed
into five groups, n=30: C (control, no heat treatment), A-575 (annealed at 575°C
during 15 min, followed by slow cooling and furnace opening at 200°C), A-790
(annealed at 790°C during 15 min, followed by slow cooling and furnace opening at
200°C), G (glazed at 790°C during 1,5 min, followed by fast cooling - immediate
furnace opening) and GM (modified glaze, at 790°C during 1,5 min, followed by slow
cooling and furnace opening at 200°C). Biaxial flexural strength was determined by
the piston-on-three ball test (ISO 6872/2008). Weibull modulus (m) and characteristic
strength (σ0) were calculated from the results. The surface roughness (Ra and Rz)
was measured before and after the treatments. One specimen from each group was
used for X-ray diffraction. A-790 produced the highest values of fracture strength
(211.7 MPa). The values of σ0 obtained for the other tested regimens (A-575: 167.9
MPa, GM: 157.7 MPa and G: 153.7 MPa) were lower than those from the control
group (187.7 MPa). The value of m was statistically similar between the groups. All
heat treatments were able to reduce the mean roughness (Ra) of the specimens. The
mean amplitude (Rz), showed a significant reduction only for the groups submitted to
the annealing treatments (A-575 e A-790). The X-ray diffraction analysis revealed no
changes in the crystalline phase (tetragonal leucite) of the material after the different
heat treatments. Variations in the size of the leucite crystallites after thermal cycles
were not significant. Thus, high values of fracture strength and decreased surface
roughness for a leucite reinforced glass ceramic are achieved by annealing above
the glass transition (Tg=625 ± 20ºC) after machining. This regimen (A-790) was
capable to produce favorable structural reorganization of the material, without
modifying its original crystalline structure. Annealing bellow the glass transition (A-
575) and thermal cycle for glazing (G and GM) significantly reduced the strength of
the material. / A proposição deste estudo foi investigar o efeito de tratamentos térmicos na
resistência flexural biaxial, na rugosidade superficial e na estrutura cristalina de uma
vitrocerâmica reforçada por leucita (IPS Empress CAD, Ivoclar Vivadent,
Liechtenstein). Para tanto, 150 discos foram obtidos por usinagem em equipamento
CEREC inLab MC XL (Sirona, Alemanha) e distribuídos em cinco grupos, de n=30: C
(controle, sem tratamento térmico), A-575 (annealing à 575°C por 15 min, seguido
de resfriamento lento com abertura do forno em 200°C), A-790 (annealing à 790°C
por 15 min, seguido de resfriamento lento com abertura do forno em 200°C), G
(glazeamento à 790°C por 1,5 min, seguido de resfriamento rápido com abertura
imediata do forno) e GM (glazeamento modificado à 790°C por 1,5 min, seguido de
resfriamento lento com abertura do forno em 200°C). A resistência flexural dos
discos foi determinada pelo teste piston-on-three ball, conforme normas da ISO
6872/2008 e os dados submetidos à análise de Weibull para cálculo do módulo de
Weibull (m) e da resistência característica (σ0). A rugosidade superficial (Ra e Rz)
antes e após os tratamentos foi mensurada. Um espécime de cada grupo foi
utilizado para difração de raios-X. O regime A-790 produziu os maiores valores de
resistência à fratura (211,7 MPa). Os valores de σ0 promovidos pelos demais ciclos
testados (A-575: 167,9 MPa, GM: 157,7 MPa e G: 153,7 MPa) foram inferiores aos
do grupo controle (187,7 MPa). O valor de m não diferiu significativamente entre os
grupos. Todos os tratamentos térmicos foram capazes de reduzir a rugosidade
média (Ra) dos espécimes. Já os valores de amplitude média do perfil (Rz),
apresentaram redução significativa apenas para os grupos submetidos à annealing
(A-575 e A-790). A análise de difração de raios-x revelou não ter havido mudanças
de fase cristalina (leucita tetragonal) do material após os tratamentos térmicos. As
alterações no tamanho dos cristalitos de leucita após a realização dos ciclos
térmicos não foram expressivas. Sendo assim, maiores valores de resistência à
fratura e diminuição da rugosidade superficial para uma vitrocerâmica reforçada por
leucita puderam ser conseguidos através de annealing acima da transição vítrea
(Tg=625 ± 20ºC) após a usinagem. Tal regime (A-790) foi capaz de produzir
reorganização estrutural favorável do material, sem contudo modificar sua estrutura
cristalina original. Annealing abaixo da transição vítrea (A-575) e regimes de
glazeamento (G e GM) reduziram significativamente a resistência do material.
|
Page generated in 0.0648 seconds