• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 3
  • Tagged with
  • 20
  • 20
  • 20
  • 12
  • 12
  • 12
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Conventional, microfilled and hybrid composite resins laboratory and clinical evaluations /

Dijken, Jan W. V. van. January 1987 (has links)
Thesis (doctoral)--Umeå Universitet, 1987. / Added t.p. with thesis statement inserted. Includes bibliographical references.
2

Conventional, microfilled and hybrid composite resins laboratory and clinical evaluations /

Dijken, Jan W. V. van. January 1987 (has links)
Thesis (doctoral)--Umeå Universitet, 1987. / Added t.p. with thesis statement inserted. Includes bibliographical references.
3

Avaliação da resistencia à microtração de cimentos resinosos autoadesivo e convencional

DA-RÉ, Eduardo Luiz 12 April 2016 (has links)
Objetivo: avaliar a resistência de união de dois cimentos resinosos, convencional e autoadesivo de acordo com os protocolos operacionais requeridos para esses cimentos, quando da cimentação de restaurações cerâmicas e ceroméricas, trazendo elementos para propiciar melhor compreensão da interação adesiva em procedimentos de cimentação com as referidas categorias de cimentos resinosos. Material e método: neste trabalho 20 dentes humanos cedidos pelo banco de dentes da UNIFAL foram preparados e, após serem divididos em dois grupos, neles foram cimentados cilindros de cerâmica ou de cerômero utilizando-se dois tipos de cimento resinoso (autoadesivo e convencional). Os dentes preparados foram cortados verticalmente nos sentidos vestibular-lingual e mesio-distal, obtendo-se “palitos” de cerca de 8 mm de altura e de base quadrangular que foram submetidos a teste de tração, avaliando-se a força necessária para a fratura. Os valores obtidos foram submetidos a análise estatística empregando-se o teste de análise de variância (ANOVA) e o teste de Tukey. Resultados: as forças mínima e máxima necessárias ao rompimento do cimento convencional são superiores às mesmas requeridas para o rompimento da união promovida pelo cimento autoadesivo, bem como as medianas e as médias aritméticas, independente do material restaurador empregado. O teste de Tukey demonstrou que as diferenças entre os cimentos empregados são estatisticamente significantes, independente do material restaurador. Conclusão: a diferença dos valores de resistência à tração entre os materiais de cimentação testados foi estatisticamente significante; o material utilizado para a confecção dos corpos de prova não influenciou nos valores de resistência a tração, não existindo diferenças significantes estatisticamente. / Purpose: the aim of this study was to evaluate the microtensile bond strength of two resin-based cements, conventional and self-adhesive, according to required operating protocols, when luting ceramic and indirect composite restorations. Materials and methods: 20 human molars donated by UNIFAL teeth bank were prepared and, after being divided into two groups, ceramic or composite cylinders were luted to them with two resin-based cements (conventional and self-adhesive). Prepared teeth were sectioned vertically in both buccal-lingual and mesio-distal directions, to obtain 8 mm high, square-shaped “sticks” that were subject to microtensile bond strength test, the necessary force to tracture them was evaluated. Results were subject to two-way ANOVA and Tuckey test. Results: minimum and maximum forces to disrupt conventional cement were greater than the ones required for self-adhesive cement, as well as mean bond strength, regardless the restorative material. Tukey test showed that diferences were statistically significant, regardless the restorative material. Conclusion: the difference between microtensile bond strength values of resin cements tested was statistically significant; the restorative materials did not influence microtensile bond strength values, with no statistically significant differences.
4

Basic properties of dental composites and their impact on clinical performance

Lambrechts, Paul. January 1983 (has links)
Thesis (doctoral)--Katholieke Universiteit Leuven, 1983.
5

Avaliação da rugosidade superficial e resistência à flexão de três tipos de resina composta indireta após variação de tratamento da superfície

CARNEIRO, Maria Cleide Mendes 30 May 2006 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-02-13T15:08:38Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoRugosidadeSuperficial.pdf: 498534 bytes, checksum: ca17177837e2bcac498d1c87fd045bb1 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-04-28T15:30:26Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoRugosidadeSuperficial.pdf: 498534 bytes, checksum: ca17177837e2bcac498d1c87fd045bb1 (MD5) / Made available in DSpace on 2014-04-28T15:30:26Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoRugosidadeSuperficial.pdf: 498534 bytes, checksum: ca17177837e2bcac498d1c87fd045bb1 (MD5) Previous issue date: 2006 / Neste estudo avaliou-se a rugosidade superficial em corpos-de-prova confeccionados com três tipos de resinas indicadas para confecção de restaurações indiretas, SR Adoro (Ivoclar-Vivadent) (GA), Signum Matrix (Heraeus-Kulzer) (GSM) e Signum<sup>+</sup> (Heraeus-Kulzer) (GSP), assim como a resistência à flexão após serem utilizados diferentes tratamentos de superfície com o propósito de se verificar a influência dos mesmos na resistência mecânica dos materiais. Obteve-se 120 corpos-de-prova de cada tipo de resina de acordo com as recomendações dos fabricantes, os quais foram divididos e tratados com: A- Jateamento com óxido de alumínio a 50μm por 6 s a 60-80 libras (Grupo Controle); B- Jateamento e silanização com Monobond (Ivoclar Vivadent) e Excite DSC (Ivoclar Vivadent); C- Jateamento e condicionamento com ácido ortofosfórico a 37% por 3 minutos e D- Jateamento, condicionamento e silanização. Após a execução do tratamento superficial, analisou-se os corpos-de-prova em rugosímetro Mytutoyo no parâmetro Ra e teste de flexão por compressão em três pontos em máquina de ensaio universal Kratos. Submeteu-se os dados observados à análise estatística, tendo como nível de significância 5% para a construção dos resultados. Os resultados mostraram um comportamento bastante coerente com o que é visto na literatura com relação à composição das resinas estudadas, os quais apresentaram inicialmente lisura de superfície similar (p>0.05). Com a aplicação dos tratamentos de superfície, houve um comportamento bastante diversificado entre os materiais. Os grupos que receberam a aplicação de silano e adesivo apresentaram superfícies mais lisas e maiores valores de resistência flexural em todas as resinas. No entanto não houve correlação dos valores de rugosidade com a resistência flexural, a qual demonstrou ser maior nas resinas SR Adoro e Signum Matrix, sendo que nesta última, apenas após a silanização é que se observou melhoria deste aspecto flexural. / The purpose of this study was to assess the roughness and flexural strength in indirect composites with different surface treatments. One hundred twenty specimens were made from each resin: SR Adoro (Ivoclar- Vivadent) (GA), Signum Matrix (Heraeus Kulzer) (GSM) and Signum<sup>+</sup> (Heraeus Kulzer) (GSP), according their manufacturer’s recommendations. The surface treatments applied was: Asandblasting with alumina oxide 50μm for 6 s at 60-80 pounds (Control Group); Bsandblasting and silanization with Monobond (Ivoclar Vivadent) plus Excite DSC (Ivoclar Vivadent); C- sandblasting plus etching with ortophosphoric acid at 37% for 3 minutes and D- sandblasting plus etching plus silanization. After this, they were carried out on roughness analysis on Mitutoyo appliance on Ra parameter and tree-point flexural test on Kratos universal machine. The results were analyzed by ANOVA (Tukey), Kruskal-Wallis (Dunn). Besides T- couple test to compare the initial and final roughness, Linear Correlation Test of Pearson for verify the correlation between roughness and flexural strength with 5% for significance. Both of materials showed the same initial roughness (p>0.05), but with the surface treatments, there was a great behavior variation with them, but with silanization could be take the smoothest surface among the groups. In spite of this, there wasn’t correlation between roughness and flexural strength in none of the groups. The flexural strength was greater in SR Adoro and Signum Matrix, but the later showed better flexural strength only after silanization.
6

Análise por microscopia eletrônica de varredura da “Smear layer” produzida em preparos com pontas diamantadas e pontas CVD

MOREIRA JUNIOR, Mário Tavares January 2008 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-02-14T14:37:56Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AnaliseMicroscopiaEletronica.pdf: 1319761 bytes, checksum: e7fba383968661705872281d67dc32f5 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-04-30T13:12:34Z (GMT) No. of bitstreams: 2 Dissertacao_AnaliseMicroscopiaEletronica.pdf: 1319761 bytes, checksum: e7fba383968661705872281d67dc32f5 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2014-04-30T13:12:34Z (GMT). No. of bitstreams: 2 Dissertacao_AnaliseMicroscopiaEletronica.pdf: 1319761 bytes, checksum: e7fba383968661705872281d67dc32f5 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2008 / Neste trabalho, foi realizada análise comparativa dentinária após preparos com pontas diamantadas em alta rotação e pontas diamantadas CVD em ultrasom, associados ao condicionamento ácido em concentrações diferentes, para avaliar a quantidade de smear layer produzida e a obstrução de túbulos dentinários .Foram utilizados 30 incisivos bovinos, distribuídos em 3 grupos de 10 amostras, sendo avaliados os preparos entre si, os preparos associados ao condicionamento ácido dentinário em gel a 37%, e os preparos associados a condicionamento ácido dentinário em gel a 15%. As amostras foram analisadas através de microscopia eletrônica de varredura. Foi verificada diferença estatística entre os sistemas, sugerindo que, comparativamente, as pontas CVD em ultrssom proporcionaram formação de menor quantidade de smear layer nos três grupos, e maior quantidade de túbulos dentinários desobstruídos entre preparos e condicionamento dentinário. / In this work, was ready dental comparative analysis after preparation using diamond points in high rotation and diamond points cvd in ultra-sound. Was utilized 30 bovin teeth, distributed in 3 groups of 10 sample each, have been one group analysed just the comparative between dental preparations. Other group of sample was analysed in relationship to preparation with two sistems both employing acid etching in dentin with phosphoric acid gel at 37%, and a third group employing acid etching in dentin with phosphsoric acid gel at 15% . The samples was analysed by scanning transmission electron microscopy, for to verification smear layer quantitative formed and obstructed dentin tubules. Was verifyed esthatistics differences between the two sistems, suggesting the cvd points in ultr-som offer lower smear layer quantitative present in the three groups, and higher quantitative of desobstructed dentin tubules, in comparative between dentin etching and dental preparations.
7

Estudo clínico randomizado da eficiência de cimentos de ionômero de vidro no controle da hipersensibilidade dentinária / Randomized clinical trial of dentin desensitizing agents in the control of dentin hypersensitivity

Madruga, Marina de Matos 23 April 2014 (has links)
Submitted by Fabiano Malheiro (fabianomalheiro22@hotmail.com) on 2017-06-07T17:48:34Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Estudo clínico randomizado da eficiência de cimentos de ionômero de vidro no controle da hipersensibilidade dentinária.pdf: 1005124 bytes, checksum: 267a83e1e44844abaa1b52b31935bb52 (MD5) / Made available in DSpace on 2017-06-07T17:48:34Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Estudo clínico randomizado da eficiência de cimentos de ionômero de vidro no controle da hipersensibilidade dentinária.pdf: 1005124 bytes, checksum: 267a83e1e44844abaa1b52b31935bb52 (MD5) Previous issue date: 2014-04-23 / Sem bolsa / A hipersensibilidade dentinária é caracterizada como uma reação dolorosa da dentina exposta a estímulos não-nocivos de natureza química, térmica, tátil ou osmótica. Entre os tratamentos, o cimento de ionômero de vidro atua na redução da dor através da obliteração dos túbulos dentinários. O objetivo desse estudo clínico randomizado, duplo-cego e de boca-dividida foi avaliar a eficiência no controle da hipersensibilidade de um cimento de ionômero de vidro modificado por resina, Clinpro XT® (3M Espe, Minnesota, EUA), e um ionômero de vidro convencional, Vidrion R® (SS White, Gloucester, Reino Unido). Como critérios de inclusão, os pacientes deveriam ter pelo menos 2 dentes em diferentes hemi-arcos apresentando o problema. Vinte pacientes, perfazendo 152 dentes com hipersensibilidade, foram aleatoriamente divididos em dois grupos de intervenção. Em um hemi-arco foi aplicado o Clinpro XT, e no outro o tratamento convencional com Vidrion R. Previamente ao tratamento (baseline), a sensibilidade dolorosa foi avaliada por teste tátil e evaporativo utilizando a Escala Visual Analógica (EVA). Após a aplicação, avaliações periódicas foram feitas nos seguintes intervalos: 5 minutos; 7, 14, 21, 30, 90 e 180 dias. A análise estatística foi feita utilizando os métodos não-paramétricos de Kruskal-Wallis, Friedman para comparações entre tempos para cada material e Mann-Whitney para comparação entre os materiais utilizados (a=5%). Para ambos os testes tátil e evaporativo houve diminuição significativa da dor imediatamente após aplicação dos produtos (5 min). Após a aplicação dos materiais os valores das medianas foram estatisticamente inferiores aos valores do baseline durante os 6 meses de acompanhamento (p<0.05). Contudo, em 180 dias de acompanhamento nenhuma diferença estatística significante foi observada entre os dois tipos de iônomeros frente aos estímulos testados. Ambos os materiais, Clinpro XT e Vidrion R, demonstraram efeitos significativos na redução da hipersensibilidade nos 6 meses de avaliação clínica. / Dentin hypersensitivity is characterized as a painful reaction of exposed dentine to chemical, thermal, tactile or osmotic non-harmful stimulus. Among treatments, the glass ionomer cement acts in reducing pain through the obliteration of dentinal tubules. The aim of this randomized, double-blind and split-mouth clinical trial was to evaluate and compare the desensitizing efficacy of a resin modified glass ionomer cement, Clinpro XT® (3M Espe, Minnesota, USA), and a conventional glass ionomer cement, Vidrion R® (SS White, Gloucester, UK), at 6-months follow-up. Subjects should have at least two teeth in different hemiarchs with dentin hypersensitivity. Twenty patients with 152 hypersensitive teeth were randomly divided into two intervention groups. One group received the Clinpro XT and the other conventional glass ionomer cement Vidrion R. Prior to the desensitizing treatment, painful symptoms were assessed by tactile and air blast tests using the Visual Analogue Scale (VAS). Re-evaluations of the treatments occurred after 5 minutes; 7, 15, 21, 30, 90 and 180 days. The statistical analysis was performed using the Kruskal-Wallis, Friedman and Mann-Whitney analysis (a=5%). In both tests (tactile and air blast) there was significant reduction of painful symptoms immediately after application of materials (5 min). The median values of VAS score were statistically lower than baseline values during the 6-month follow-up (p<0,05). Besides, no significant differences were observed between the two types of glass ionomer cements evaluated with tactile and air blast test in all evaluation periods. Clinpro XT and Vidrion R demonstrated significant effects in reducing dentin hypersensitivity at 6- months follow-up.
8

Obtenção de nanocompósitos de resinas acrílicas dentárias com partículas de alumina dopada com manganês / Obtaining nanocomposite dental acrylic resins with particles of alumina doped with manganese

Cruzeiro, Mario Thadeo Rodrigues 23 September 2014 (has links)
Submitted by Fabiano Malheiro (fabianomalheiro22@hotmail.com) on 2017-06-09T15:18:33Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Obtenção de nanocompósitos de resinas acrílicas dentárias com partículas de alumina dopada com manganês.pdf: 828927 bytes, checksum: 042b9bc4f5329424faab8121e985d13a (MD5) / Made available in DSpace on 2017-06-09T15:18:33Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Obtenção de nanocompósitos de resinas acrílicas dentárias com partículas de alumina dopada com manganês.pdf: 828927 bytes, checksum: 042b9bc4f5329424faab8121e985d13a (MD5) Previous issue date: 2014-09-23 / Sem bolsa / Pigmentos de Al2O3:Mn foram utilizados de forma inovadora no presente trabalho para melhorar as características estéticas de resinas acrílicas para base de prótese. O objetivo deste estudo foi investigar a síntese e o efeito da pigmentação de nanopartículas de Al2O3:Mn na estabilidade de cor de resinas acrílicas. As resinas acrílicas comerciais Clássico Jet X15 rosa e Clássico Jet X15 incolor foram avaliadas. Nanopós de Al2O3:Mn foram preparados pelo método de precursores poliméricos, para estudar a relação entre a transição de fase. A morfologia dos pigmentos foi analisada por meio de um microscópio eletrônico de varredura (MEV) e a energia dispersiva por técnicas de espectroscopia de raios-X (EDX). Espécimes em forma de prisma (65mm × 10mm × 2,5mm) de resina acrílica incolor cor rosa e de resina acrílica incolor modificada com 1% e 2% de pigmento sintetizado à base de Al1,96Mn0,04O3 foram fabricados. A cor dos espécimes foi medida com um espectrofotômetro e avaliadas dentro do sistema CIE L*a*b*. A resistência à flexão e o módulo de elasticidade dos materiais foram avaliados em ensaio de flexão por três pontos. Os pigmentos obtidos apresentaram colorações diferenciadas em relação à antes e após a aplicação, devido à interação das partículas do pigmento com o material da resina. Notou-se que pigmentos de nanopartículas contendo manganês apresentaram coloração rosa mais compatível com resinas coloridas comerciais. Os conteúdos de cátions cromóforos (responsáveis pela coloração) do Al2O3, de acordo com a metodologia proposta neste trabalho, são mínimos e puderam ser controlados. Por meio de ensaios de flexão, notou-se um efeito positivo em relação ao aumento da resistência mecânica, em função da adição do pigmento sintetizado. Conclui-se que os pigmentos sintetizados têm duas vantagens em relação às resinas acrílicas coloridas comerciais: a possibilidade de controle efetivo de cor e o aumento de resistência mecânica. / Al2O3:Mn pigments were used in an innovative way in this work to improve the aesthetic characteristics of acrylic resin for denture base. The aim of this study was to investigate the synthesis and the effect of pigmentation of nanoparticles of Al2O3:Mn on the color stability of acrylic resins. Commercial acrylic resins Classic Jet X15 pink and colorless Classic Jet X15 were evaluated. Nanopowders of Al2O3:Mn were prepared through the polymeric precursors method, in order to study the relationship between phase transition. The morphology of the pigments was analyzed by a scanning electron microscope (SEM) and x-ray energy dispersive spectroscopy (EDX). Prism-shaped specimens (65mm × 10mm × 2.5mm) of pink-colored acrylic resin and of colorless acrylic resin with 1% or 2% of the synthesized Al1.96Mn0.04O3 pigment were prepared. The color of the specimens was measured with a spectrophotometer and evaluated in the CIE L*a*b* system. The flexural strength and elastic modulus of the materials were measured on three-point bending mode. The pigments obtained showed different color compared to before the application, due to the interaction of the pigment particles with the resin material. It was noted that pigments containing manganese nanoparticles exhibit a pink coloration which is more compatible to commercial resins. The content of Al2O3 chromophore cations (responsible for the color), according to the methodology proposed in this work, is minimal and could be controlled. By using the flexural test a positive effect was noticed as regards the increase in mechanical strength as a function of pigment addition. In conclusion, the synthesized pigments have two advantages in comparion with the commercial colored acrylic resins: the possibility of effective color control and the increase in mechanical strength.
9

Avaliação laboratorial de materiais e técnicas utilizados em ortodontia / Laboratory evaluation of materials and techniques used in orthodontics

Oliveira, Adauê Siegert de 23 October 2015 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-12T13:15:01Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Avaliação laboratorial de materiais e técnicas utilizados em Ortodontia.pdf: 23257773 bytes, checksum: 8ebe2d1533573ee98e16abdd1d133f28 (MD5) / Made available in DSpace on 2017-06-12T13:15:01Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Avaliação laboratorial de materiais e técnicas utilizados em Ortodontia.pdf: 23257773 bytes, checksum: 8ebe2d1533573ee98e16abdd1d133f28 (MD5) Previous issue date: 2015-10-23 / Sem bolsa / A evolução dos materiais ortodônticos facilitou a prática clínica, difundiu a especialidade e popularizou os tratamentos. Propiciar tratamentos mais rápidos, sem prejuízo estético, confortáveis ao paciente e minimizando efeitos colaterais são os maiores objetivos das pesquisas nessa especialidade. Diversos fatores clínicos motivam, constantemente, novos estudos para desenvolvimento e evolução dos materiais associados à técnica. A exigência estética direciona o aprimoramento dos braquetes cerâmicos bem como das ligaduras elásticas transparentes. Por outro lado, a forte associação em Ortodontia e Odontopediatria exige que procedimentos ortodônticos em crianças sejam rápidos e eficientes devido ao tempo clínico reduzido. Assim, este estudo buscou contribuir para a evolução desses materiais por meio de estudos in vitro. Os objetivos foram: avaliar in vitro o efeito do tipo de dentifrício utilizado (regular ou clareador) na estabilidade de cor de ligaduras elásticas translúcidas, onde a variável-resposta foi alteração cromática (?E) de acordo com os parâmetros CIEL*a*b* e foi aferida através de espectrofotômetro; analisar as implicações na adesão de braquetes ao esmalte relacionadas a alterações de posicionamento dos braquetes e remoção do excesso de cimento durante a colagem, para isto, foi analisada a resistência de união (MPa) de braquetes metálicos unidos ao esmalte bovino utilizando diferentes protocolos de colagem, tendo como variável-resposta secundária o modo de falha da união; avaliar o efeito da utilização de duas fontes de luz simultâneas durante a fotoativação do cimento ortodôntico na resistência de união de braquetes ao esmalte e avaliar a adição de sal de iodônio a compósitos adesivos fotoativados para reduzir o tempo de fotoativação necessário para colagem de braquetes ortodônticos ao esmalte dentário. / The evolution of orthodontic materials facilitated clinical practice, spread the specialty and popularized treatments. Providing treatments faster, without prejudice aesthetic, comfortable for the patient and minimizing side effects are the major objectives of research in this specialty. Several clinical factors motivate constantly new studies for development and evolution of materials associated with the technique. The aesthetic requirement directs the improvement of ceramic brackets and the transparent elastic bandages. On the other hand, the strong association in Orthodontics and Pediatric Dentistry requires orthodontic procedures in children are fast and efficient due to reduced clinical time. The objectives are to evaluate in vitro effect of the type of toothpaste used (regular or bleaching) on color stability of elastic bandages translucent, where the response variable is color change (?E) according to the parameters CIEL * a * b * and will be measured by a spectrophotometer; analyze the implications for the accession of brackets to enamel related to changes in positioning of the brackets and removing excess cement during bonding, for this, we will analyze the bond strength (MPa) of metal brackets attached to bovine enamel using protocols collage. With the response variable secondary mode joint failure; assess the effect of using two sources of simultaneous light for the photoactivation of orthodontic cement in bracket bond strength to enamel and evaluate the addition of iodonium salt to photoactivated adhesive composite to reduce the time of curing required for bonding of orthodontic brackets to tooth enamel.
10

Influência do uso de laser na estimulação do reparo ósseo alveolar:revisão sistemática / Influence of laser on alveolar bone repair:systematic review

Lemes, Carmen Helena Jacques 29 January 2015 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-13T11:33:09Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência do uso de laser na estimulação do reparo ósseo alveolar revisão.pdf: 490703 bytes, checksum: 50c4dc0f46059e1631790ce337bd958c (MD5) / Made available in DSpace on 2017-06-13T11:33:09Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência do uso de laser na estimulação do reparo ósseo alveolar revisão.pdf: 490703 bytes, checksum: 50c4dc0f46059e1631790ce337bd958c (MD5) Previous issue date: 2015-01-29 / Sem bolsa / Na literatura odontológica, o uso da laserterapia é rica em informações sobre sua ação nos tecidos moles, nos implantes dentários, em cavidades ou injúrias ósseas, exceto no reparo ósseo alveolar. O presente estudo teve como objetivo avaliar, por meio de revisão sistemática da literatura, se há evidência que suporte o uso do laser na estimulação do reparo ósseo alveolar após exodontia. A metodologia foi realizada de acordo com as diretrizes de PRISMA. Foram realizadas pesquisas bibliográficas estruturadas nas bases de dados IBECS/Bireme, ISI Web of Science, LILACS/Bireme, MEDLINE/PubMed, SciELO, Scopus e The Cochrane Library utilizando, a partir de descritores relacionados ao assunto. Os critérios de elegibilidade incluíam: estudos clínicos ou em modelo animal que comparassem o reparo e/ou cicatrização óssea alveolar após exodontia com e sem o uso de laser, tendo como desfecho análises quantitativas ou qualitativas do reparo ósseo alveolar. Foram selecionados apenas estudos publicados em inglês, espanhol e português e publicados de 1995 a 2014. A última busca foi realizada em dezembro de 2014, na qual foram encontrados 3235 registros (551 duplicatas), sendo triados 2684 artigos por título e/ou resumo. Cinco artigos foram selecionados para leitura do texto completo, sendo quatro incluídos na revisão. Os dados foram extraídos e categorizados de acordo com o tipo de dente extraído, tipo de laser utilizado, potência (mW), comprimento de onda (nm), dose de energia aplicada (J/cm2), tempo, distância e protocolo de aplicação, além do período pós-operatório de observação. Embora poucos estudos tenham sido incluídos nesta revisão sistemática, sendo todos os estudos realizados em modelos animais, a literatura sugere que a laserterapia pode apresentar efeito positivo na aceleração do reparo ósseo alveolar pós-exodontia. Entretanto estudos clínicos são necessários para avaliar de forma mais clara os benefícios da laserterapia no pós-cirúrgico, especialmente no que concerne o tipo de laser a ser utilizado, sua potência e comprimento de onda, além da dose de energia e modo de aplicação. / In dental literature the use of laser therapy is rich in information about the laser action in soft tissues, dental implants, bone cavities or injuries, except in the alveolar bone repair. The aim of the present study was to gather evidence, by means of a systematic review of the literature, to support or not the use of laser in the stimulation of alveolar bone repair after dental extraction. The methods were carried out according to the PRISMA guidelines. Bibliographic structured searches were carried out in databases: IBECS/Bireme, ISI Web of Science, LILACS/Bireme, MEDLINE/PubMed, SciELO, Scopus and The Cochrane Library using descriptors related to the topic. The eligibility criteria included: clinical studies or studies using animal model to compare the alveolar bone healing repair after dental extraction with and without the use of laser, with quantitative or qualitative analysis of alveolar bone repair as outcome. Only studies published in English, Spanish and Portuguese and published from 1995 to 2014 were selected. The last search was conducted in December 2014, in which 3235 records were found (551 duplicates), and 2684 were screened by titles and/or abstracts. Five articles were selected for full-text reading, and four were included in the review. Data were extracted and categorized according to the type of tooth extracted, type of laser used, power (mW), wavelength (nm), energy dose applied (J/cm2), time, distance, and application protocol, a postoperative period of observation. Although few studies have been included in this review, all of them using animal models, the literature suggests that the laser therapy might have a positive effect on acceleration of alveolar bone repair after tooth extraction. However, clinical studies are needed to assess more clearly the benefits of laser therapy after dental surgery, particularly regarding the type of laser, power, wavelength, energy dose and method of application.

Page generated in 0.028 seconds