• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento e validação de metodologia analítica para a determinação de fármacos em amostras de água, superficial e tratada, utilizando a cromatografia líquida de ultra performance acoplada à espectrometria de massas Tandem (UPLC-MS/MS) / Development and validation of analytical methodology for determination of pharmaceutical compounds in surface and surface treated water samples by ultra performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS)

Rodrigues, Valéria Chiérice 19 December 2011 (has links)
O relevante conceito de sustentabilidade dos dias atuais leva a população a pensar no tratamento dos recursos naturais e principalmente na qualidade e escassez da água. A grave problemática quanto à gestão dos resíduos urbanos no país, desde sua produção, coleta e disposição final são os desafios colocado aos municípios e a sociedade em geral. O uso cada vez mais abundante dos medicamentos farmacêuticos gera uma demanda de resíduos que acabam atingindo os leitos dos rios. Com avanço das tecnologias é possível monitorar e conhecer os resíduos que afetam indiretamente e diretamente as águas das bacias hidrográficas. O objetivo deste trabalho foi desenvolver e validar uma metodologia analítica para a determinação dos resíduos de fármacos (ácido acetil salicílico, diclorofenaco de sódio, paracetamol, ibuprofeno e fenoprofeno) em águas utilizando a cromatografia líquida de ultra performance acoplada à espectrometria de massas tipo tandem (UPLC-MS/MS). Foram utilizadas duas fases moveis distintas. Para os fármacos paracetamol e diclofenaco foi utilizado como fase móvel água: metanol (1:1; V/V) com adição de ácido fórmico e a ionização de eletrospray em modo positivo; para os fármacos acetil salicílico, ibuprofeno e fenoprofeno foi utilizado água: metanol (1:1; v/v) com adição de acetato de amônio e a ionização de eletrospray em modo negativo. O desempenho do método foi avaliado quanto aos seguintes parâmetros: especificidade e seletividade, faixa de trabalho, linearidade; limite de detecção e limite de quantificação, exatidão, robustez e incerteza de medição. Os resultados obtidos comprovaram a adequabilidade do método ao propósito supracitado. Os valores obtidos para o limite de decisão (ccα) e capabilidade de detecção (ccβ) foram: paracetamol 0,21 e 0,34 μg L -1; diclofenaco 2,42 e 3,24 μg L -1 ; AAS 1,56 e 2,45 μg L -1; ibuprofeno 2,34 e 3,21 μg L -1 e fenoprofeno 1,89 e 2,33 μg L-1, respectivamente. A metodologia foi aplicada na caracterização de amostras de água superficial (bruta) e tratada proveniente de áreas de captação e de tratamento de água da bacia hidrográfica do Paraíba do Sul. Foram realizadas duas coletas distintas, setembro/ 2010 e novembro/ 2010, nos municípios de Guararema, São José dos Campos, Taubaté e Pindamonhangaba. Em 31,2 % das amostras, Cinco amostras de água bruta das 16 amostras analisadas, foram encontrados resíduos de paracetamol. Os resultados obtidos apresentaram-se em uma faixa de concentração de 0,10 a 0,50 μg L -1. / The relevant concept of sustainability of the present day leads people to think about the treatment of natural resources and particularly in the quanlity and scarcity of water. The serious problems regarding the management of municipal waste in the country, from production, collection and disposal are the challenges facing municipalities and society in general. The increasing use of pharmaceutical drugs most abundant generates a demand for waste that eventually reach the river beds. With advancement of technologies and know you can monitor the waste that directly and indirectly affect the waters of river basins. The objective of this study was to develop and validade analytical methods for residues of drugs (aspirin, sodium diclofenac, paracetamol, ibuprofen and fenoprofen) in water using ultra performance liquida chromatography coupled to tandem mass spectrometry (UPLC-MS/MS). We used two different mobile phases. For the drugs paracetamol and diclofenac was used as mobile phase water:methanol (1:1, v/v) with addition of formic acid in positive electrospray ionization mode. For drugs acetyl salicylic acid, ibuprofen and fenoprofen was used mobile phase water:methanol (1:1, v/v) with addition of ammonium acetate and negative electrospray ionization mode. The performance of the method was evaluated on the following parameters: specificity and selectivity, working range, lineariry, limit of detection and limit of quantification, accuracy, ruggedness and uncertainty measurement. The result obtained proved the suitability of the method for fit purpose. The values obtained for the decision limit (ccα) and detection capability (ccβ) were 0.21 and 0.34 μg L-1, diclofenac 2.42 and 3.24 μgL-1, ASA 1.56 and 2.45 μgL-1, respectively. The methodology was applied in the characterization of samples of surface water (raw) and treated from catchment areas and water treatment basin of Paraíba do sul were two distinct collections, September/2011 and November 2010 in the municipalities of Guararema, São José dos Campos, Taubaté and Pindamonhangaba. In 32,2% of all samples, five samples of 16 raw water samples, residues were found for paracetamol. The results were presented in a concentration range from 0.10 to 0.50 μg L-1.
2

Desenvolvimento e validação de metodologia analítica para a determinação de fármacos em amostras de água, superficial e tratada, utilizando a cromatografia líquida de ultra performance acoplada à espectrometria de massas Tandem (UPLC-MS/MS) / Development and validation of analytical methodology for determination of pharmaceutical compounds in surface and surface treated water samples by ultra performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS)

Valéria Chiérice Rodrigues 19 December 2011 (has links)
O relevante conceito de sustentabilidade dos dias atuais leva a população a pensar no tratamento dos recursos naturais e principalmente na qualidade e escassez da água. A grave problemática quanto à gestão dos resíduos urbanos no país, desde sua produção, coleta e disposição final são os desafios colocado aos municípios e a sociedade em geral. O uso cada vez mais abundante dos medicamentos farmacêuticos gera uma demanda de resíduos que acabam atingindo os leitos dos rios. Com avanço das tecnologias é possível monitorar e conhecer os resíduos que afetam indiretamente e diretamente as águas das bacias hidrográficas. O objetivo deste trabalho foi desenvolver e validar uma metodologia analítica para a determinação dos resíduos de fármacos (ácido acetil salicílico, diclorofenaco de sódio, paracetamol, ibuprofeno e fenoprofeno) em águas utilizando a cromatografia líquida de ultra performance acoplada à espectrometria de massas tipo tandem (UPLC-MS/MS). Foram utilizadas duas fases moveis distintas. Para os fármacos paracetamol e diclofenaco foi utilizado como fase móvel água: metanol (1:1; V/V) com adição de ácido fórmico e a ionização de eletrospray em modo positivo; para os fármacos acetil salicílico, ibuprofeno e fenoprofeno foi utilizado água: metanol (1:1; v/v) com adição de acetato de amônio e a ionização de eletrospray em modo negativo. O desempenho do método foi avaliado quanto aos seguintes parâmetros: especificidade e seletividade, faixa de trabalho, linearidade; limite de detecção e limite de quantificação, exatidão, robustez e incerteza de medição. Os resultados obtidos comprovaram a adequabilidade do método ao propósito supracitado. Os valores obtidos para o limite de decisão (ccα) e capabilidade de detecção (ccβ) foram: paracetamol 0,21 e 0,34 μg L -1; diclofenaco 2,42 e 3,24 μg L -1 ; AAS 1,56 e 2,45 μg L -1; ibuprofeno 2,34 e 3,21 μg L -1 e fenoprofeno 1,89 e 2,33 μg L-1, respectivamente. A metodologia foi aplicada na caracterização de amostras de água superficial (bruta) e tratada proveniente de áreas de captação e de tratamento de água da bacia hidrográfica do Paraíba do Sul. Foram realizadas duas coletas distintas, setembro/ 2010 e novembro/ 2010, nos municípios de Guararema, São José dos Campos, Taubaté e Pindamonhangaba. Em 31,2 % das amostras, Cinco amostras de água bruta das 16 amostras analisadas, foram encontrados resíduos de paracetamol. Os resultados obtidos apresentaram-se em uma faixa de concentração de 0,10 a 0,50 μg L -1. / The relevant concept of sustainability of the present day leads people to think about the treatment of natural resources and particularly in the quanlity and scarcity of water. The serious problems regarding the management of municipal waste in the country, from production, collection and disposal are the challenges facing municipalities and society in general. The increasing use of pharmaceutical drugs most abundant generates a demand for waste that eventually reach the river beds. With advancement of technologies and know you can monitor the waste that directly and indirectly affect the waters of river basins. The objective of this study was to develop and validade analytical methods for residues of drugs (aspirin, sodium diclofenac, paracetamol, ibuprofen and fenoprofen) in water using ultra performance liquida chromatography coupled to tandem mass spectrometry (UPLC-MS/MS). We used two different mobile phases. For the drugs paracetamol and diclofenac was used as mobile phase water:methanol (1:1, v/v) with addition of formic acid in positive electrospray ionization mode. For drugs acetyl salicylic acid, ibuprofen and fenoprofen was used mobile phase water:methanol (1:1, v/v) with addition of ammonium acetate and negative electrospray ionization mode. The performance of the method was evaluated on the following parameters: specificity and selectivity, working range, lineariry, limit of detection and limit of quantification, accuracy, ruggedness and uncertainty measurement. The result obtained proved the suitability of the method for fit purpose. The values obtained for the decision limit (ccα) and detection capability (ccβ) were 0.21 and 0.34 μg L-1, diclofenac 2.42 and 3.24 μgL-1, ASA 1.56 and 2.45 μgL-1, respectively. The methodology was applied in the characterization of samples of surface water (raw) and treated from catchment areas and water treatment basin of Paraíba do sul were two distinct collections, September/2011 and November 2010 in the municipalities of Guararema, São José dos Campos, Taubaté and Pindamonhangaba. In 32,2% of all samples, five samples of 16 raw water samples, residues were found for paracetamol. The results were presented in a concentration range from 0.10 to 0.50 μg L-1.
3

Avaliação da presença de fármacos, por LC-MS/MS, em águas superficiais pré e pós-tratamento convencional por ensaio Jar-test e caracterização do risco humano / Evaluation of the presence of drugs by LC-MS/MS in surface water before and after conventional treatment by jar-test test and the characterization of human risk

Pais, Mariana Castello Novo 03 June 2013 (has links)
O aumento crescente da população brasileira em combinação com o uso abusivo de medicamentos no mercado nacional, aliados à falta de saneamento básico e de políticas públicas para o correto gerenciamento de alguns tipos de resíduos têm resultado na presença de compostos farmacêuticos em ambientes aquáticos. Estudos indicam que várias dessas substâncias parecem ser persistentes no ambiente e algumas vezes, resistem até mesmo às estações de tratamento de água, fazendo-se presentes na água tratada, que chega à população. O presente trabalho visou analisar quantitativamente a presença dos anti-inflamatórios e do analgésico mais comumente consumido no Brasil: diclofenaco, cetoprofeno, naproxeno, indometacina, ibuprofeno e o paracetamol em águas superficiais, por LC-MS/MS com extração em fase sólida, antes e depois do tratamento convencional, em escala laboratorial pelo ensaio de Jar-Test, bem como caracterizar o risco humano pela presença destes compostos na água após o tratamento. Os métodos utilizados na quantificação destes fármacos apresentaram bons resultados: a análise cromatográfica obteve coeficientes de correlação entre 0,9952-0,9991, com limites de quantificação de 0,5ng/mL- 50ng/mL e desvios padrões entre (0,08-2,08); na recuperação do método de extração em fase sólida o diclofenaco, o cetoprofeno, o naproxeno e a indometacina apresentaram cerca de 100% de recuperação, o ibuprofeno apresentou apenas 48%(±9,37) de recuperação e o paracetamol aproximadamente 19,84% (±2,52); no ensaio de jar-test, observou-se que apenas o cetoprofeno e o ibuprofeno não foram removidos completamente no tratamento utilizado (remoção de 0-15% do cetoprofeno e de 0-35% do ibuprofeno). Amostras ambientais foram coletadas e tratadas pelo ensaio de Jar-Test, e os valores obtidos para o cetoprofeno e ibuprofeno após o tratamento foram de 18,67-19,65ng/L e 147ng/L, respectivamente. Através de cálculos, com a dose de referência de cada um dos compostos e considerando as características desta exposição, foi possível concluir que nestas concentrações o cetoprofeno e o ibuprofeno não causam risco à saúde humana. / The increasing population growth in combination with the misuse of drugs in the domestic market, coupled with the lack of sanitation and public policies for proper management of some types of waste have resulted in the presence of pharmaceutical compounds in aquatic environments. Studies indicate that several of these substances appear to be persistent in the environment and sometimes even resistant to water treatment plants, being present in the treated water which reaches the population. This study aimed to analyze quantitatively the presence of anti-inflammatory and analgesic most commonly consumed in Brazil: diclofenac, ketoprofen, naproxen, indomethacin, ibuprofen and paracetamol in surface waters by LC-MS/MS with solid phase extraction prior and after conventional treatment in a laboratory scale by using Jar-test assay, and to determine the human risk posed by the presence of these compounds in the water after treatment. The methods used to quantify these drugs showed good results: a chromatographic analysis obtained correlation coefficients between 0.9952 to 0.9991, with limits of quantification of 0.5 ng/mL- 50ng/mL and standard deviations between (0.08 - 2.08); recovery method of solid phase extraction to diclofenac, ketoprofen, naproxen and indomethacin showed about 100% recovery, ibuprofen showed only 48% (± 9.37) and paracetamol approximately 19 84% (± 2.52) recovery; in the jar-test, it was observed that only ketoprofen and ibuprofen were not completely removed (removal: 0-15% of ketoprofen and 0-35% of ibuprofen). Environmental samples were collected and handled by jar-test test, and the values obtained for ketoprofen and ibuprofen after treatment were 18.67 to 19.65 ng / L and 147ng / L, respectively. By calculation with a reference dose of each compound and considering the characteristics of this display, it was concluded that these concentrations of ketoprofen and ibuprofen do not cause risk to human health.
4

Avaliação da presença de fármacos, por LC-MS/MS, em águas superficiais pré e pós-tratamento convencional por ensaio Jar-test e caracterização do risco humano / Evaluation of the presence of drugs by LC-MS/MS in surface water before and after conventional treatment by jar-test test and the characterization of human risk

Mariana Castello Novo Pais 03 June 2013 (has links)
O aumento crescente da população brasileira em combinação com o uso abusivo de medicamentos no mercado nacional, aliados à falta de saneamento básico e de políticas públicas para o correto gerenciamento de alguns tipos de resíduos têm resultado na presença de compostos farmacêuticos em ambientes aquáticos. Estudos indicam que várias dessas substâncias parecem ser persistentes no ambiente e algumas vezes, resistem até mesmo às estações de tratamento de água, fazendo-se presentes na água tratada, que chega à população. O presente trabalho visou analisar quantitativamente a presença dos anti-inflamatórios e do analgésico mais comumente consumido no Brasil: diclofenaco, cetoprofeno, naproxeno, indometacina, ibuprofeno e o paracetamol em águas superficiais, por LC-MS/MS com extração em fase sólida, antes e depois do tratamento convencional, em escala laboratorial pelo ensaio de Jar-Test, bem como caracterizar o risco humano pela presença destes compostos na água após o tratamento. Os métodos utilizados na quantificação destes fármacos apresentaram bons resultados: a análise cromatográfica obteve coeficientes de correlação entre 0,9952-0,9991, com limites de quantificação de 0,5ng/mL- 50ng/mL e desvios padrões entre (0,08-2,08); na recuperação do método de extração em fase sólida o diclofenaco, o cetoprofeno, o naproxeno e a indometacina apresentaram cerca de 100% de recuperação, o ibuprofeno apresentou apenas 48%(±9,37) de recuperação e o paracetamol aproximadamente 19,84% (±2,52); no ensaio de jar-test, observou-se que apenas o cetoprofeno e o ibuprofeno não foram removidos completamente no tratamento utilizado (remoção de 0-15% do cetoprofeno e de 0-35% do ibuprofeno). Amostras ambientais foram coletadas e tratadas pelo ensaio de Jar-Test, e os valores obtidos para o cetoprofeno e ibuprofeno após o tratamento foram de 18,67-19,65ng/L e 147ng/L, respectivamente. Através de cálculos, com a dose de referência de cada um dos compostos e considerando as características desta exposição, foi possível concluir que nestas concentrações o cetoprofeno e o ibuprofeno não causam risco à saúde humana. / The increasing population growth in combination with the misuse of drugs in the domestic market, coupled with the lack of sanitation and public policies for proper management of some types of waste have resulted in the presence of pharmaceutical compounds in aquatic environments. Studies indicate that several of these substances appear to be persistent in the environment and sometimes even resistant to water treatment plants, being present in the treated water which reaches the population. This study aimed to analyze quantitatively the presence of anti-inflammatory and analgesic most commonly consumed in Brazil: diclofenac, ketoprofen, naproxen, indomethacin, ibuprofen and paracetamol in surface waters by LC-MS/MS with solid phase extraction prior and after conventional treatment in a laboratory scale by using Jar-test assay, and to determine the human risk posed by the presence of these compounds in the water after treatment. The methods used to quantify these drugs showed good results: a chromatographic analysis obtained correlation coefficients between 0.9952 to 0.9991, with limits of quantification of 0.5 ng/mL- 50ng/mL and standard deviations between (0.08 - 2.08); recovery method of solid phase extraction to diclofenac, ketoprofen, naproxen and indomethacin showed about 100% recovery, ibuprofen showed only 48% (± 9.37) and paracetamol approximately 19 84% (± 2.52) recovery; in the jar-test, it was observed that only ketoprofen and ibuprofen were not completely removed (removal: 0-15% of ketoprofen and 0-35% of ibuprofen). Environmental samples were collected and handled by jar-test test, and the values obtained for ketoprofen and ibuprofen after treatment were 18.67 to 19.65 ng / L and 147ng / L, respectively. By calculation with a reference dose of each compound and considering the characteristics of this display, it was concluded that these concentrations of ketoprofen and ibuprofen do not cause risk to human health.

Page generated in 0.1381 seconds