Spelling suggestions: "subject:"fading flexural""
1 |
Estudo da fadiga flexural de porcelana feldspática: efeito da ciclagem mecânica e limite de resistência pelo método de escadaSchalch, Max von [UNESP] 08 March 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0
Previous issue date: 2006-03-08Bitstream added on 2014-06-13T19:05:03Z : No. of bitstreams: 1
schalch_m_dr_arafo.pdf: 538787 bytes, checksum: 4ca8b6178fc03b9c476272eb4ecb7907 (MD5) / O objetivo deste estudo foi avaliar a fadiga flexural da porcelana feldspática Duceragold (Degudent, processada por sinterização), utilizando a ciclagem mecânica e o método de escada. Foram confeccionados setenta corpos-de-prova, em forma de barra (25mm de comprimento, 5mm de largura, 2mm de espessura - ISO 6872, 1997). Os resultados mostraram resistência à flexão de 93,19MPa e limite de resistência à fadiga de 29,65MPa (redução da resistência de 68,19%). Não houve diferença estatística para a resistência à flexão após ciclagem mecânica entre G1 (87,53MPa), G2 (95,32MPa) e G3 (97,30MPa). Nestas três situações, a ciclagem mecânica empregada não foi capaz de reduzir a resistência à flexão da porcelana feldspática. Embora não tenha havido redução de resistência nos grupos ciclados mecanicamente, a avaliação fractográfica evidenciou a presença de estrias, sinais característicos de fadiga. / The aim of this study was to evaluate the flexural fatigue of a feldsphatic dental porcelain Duceragold (Degudent, convencional fusing), using cyclic loading and staircase method. Seventy specimens were made (25mm length; 5mm width; 2mm thick - ISO 6872). The flexural strength without prior cyclic loading was 93,19MPa and the limit fatigue was 29,65MPa (68,19% reduced strength). Analysis of the flexural strength with prior cyclic loading indicated no significant differences among G1 (87,53MPa), G2 (95,32MPa) and G3 (97,30MPa). On these groups, the cyclic loading did not reduce the flexural strength of a feldsphatic porcelain. Despite no reduce on strength was observed for cyclic loading groups, the fractography showed fatigue signals (striations).
|
2 |
\"Resistência à fadiga cíclica flexural de instrumentos rotatórios de Ni-Ti em razão do uso e do torque\" / Flexural cyclic fatigue resistance of NiTi rotatory instruments due to number of users and torque.Kawakami, Dirce Akemi Sacaguti 14 March 2007 (has links)
O objetivo do presente estudo foi avaliar a resistência à fadiga cíclica flexural de instrumentos rotatórios de níquel-titânio de número 25, conicidade 0,04 e 25 mm de comprimento (K3, SybronEndo), submetidos a variados torques de acionamento e repetidos ciclos de usos em canais simulados, valendo-se de dispositivo apropriado para ensaios dinâmicos. Procurou-se determinar se, além do fator de variação número de uso, há influência relacionada com o torque e, ainda, a possibilidade de interação entre número de uso e torque. Valendo-se motor elétrico acionado à velocidade de 300 rpm foram instrumentados 320 canais simulados, utilizado-se 80 instrumentos divididos em 4 grupos com 20 espécimes cada, de acordo com os torques (0,5 Ncm, 1,0 Ncm, 2,0 Ncm e 6,0 Ncm) a que seriam submetidos. Cada grupo foi subdividido em 4 subgrupos com 5 espécimes, de acordo com o número de usos (1, 3, 5 e 7 ciclos de usos). Todos os instrumentos foram submetidos a ensaio de fadiga cíclica flexural que foi realizado num dispositivo que permitia ao instrumento girar livremente, reproduzindo a instrumentação rotatória num canal curvo (40º e raio de curvatura de 5 mm), simulando o movimento de pecking, onde o instrumento deslizava pelo sulco criado no anel de aço temperado. Foi utilizada peça de mão com contra-ângulo redutor de 16:1, acionado por motor elétrico na velocidade de 300 rpm e torque idêntico ao empregado durante a fase de preparo dos canais simulados. A fratura do instrumento era facilmente detectada pelo sensor, e neste momento o contador e o temporizador paravam imediatamente. Os dados registrados no contador e no temporizador foram tranformados em segundos. Para a avaliação estatística empregou-se ANOVA e o teste t de Student (p<0,01). No que diz respeito ao fator de variação número de uso, não houve diferença estatística significante, enquanto as comparações feitas com o torque de 6,0 Ncm apresentaram valores de t calculado altamente significativo, com p < 0,01. Também não ocorreu interação significante entre os fatores de variação número de usos e torque. Baseado nos resultados deste estudo pode-se concluir que o torque afetou a resistência à fadiga cíclica flexural dos instrumentos rotatórios de NiTi, sendo menor naqueles submetidos à torque elevado, enquanto o número de usos em até 7 vezes não afetou . / The aim of the present study was to evaluate the flexural cyclic fatigue resistance of nickel-titanium rotary instruments, number 25, taper 0,04, and length of 25mm (K3, SybronEndo), when submitted to several torque values and number of uses in simulated canal blocks, by using devices appropriated for dynamic tests. It was tried to detect whether, in addition to the factor number of uses, there would be an influence related to torque, or even the possibility of an interaction between number of uses and torque. The data was collected from 320 simulated canals that were prepared, driven by an electrical motor at 300 rpm, using 80 instruments divided in 4 groups of 20 sample each, based on torque values (0,5 Ncm, 1,0 Ncm, 2,0 Ncm e 6,0 Ncm). Each group was randomly divided in 4 subgroups of 5 samples each, according to the number of uses (1, 3, 5 and 7 cycles). All files were submitted to flexural cyclic fatigue test realized in a device that allows the instrument to freely rotate, reproducing the movement of an instrument rotating in a curved canal (40º angle and 5 mm of radius), simulating the pecking movement, where the instrument slide over the groove created in the hardened steel. An electric motor hand-piece was used with a contra-angle 16:1 reduction set at 300 rpm and torque value identical to that used during preparation of simulated canals. The fracture of the instrument was easily detected at moment which the counter and the timer were immediately stopped. Data collected by the counter and the timer were converted in seconds and analysed by ANOVA and t Student test (p<0.01). In regards to the number of uses factor, there was not a statistically significant difference, while comparisons made with torque value set at 6,0 Ncm showed t values significantly high, with p<0.01. It was not seen any interaction between both variables, number of uses and torque. Based on the results of this investigation, it can be concluded that torque affected the resistance to flexural cyclic fatigue of nickel-titanium rotary instruments, being low on those tested at high torque value; while the factor number of uses up to 7 times did not affect the results.
|
3 |
\"Resistência à fadiga cíclica flexural de instrumentos rotatórios de Ni-Ti em razão do uso e do torque\" / Flexural cyclic fatigue resistance of NiTi rotatory instruments due to number of users and torque.Dirce Akemi Sacaguti Kawakami 14 March 2007 (has links)
O objetivo do presente estudo foi avaliar a resistência à fadiga cíclica flexural de instrumentos rotatórios de níquel-titânio de número 25, conicidade 0,04 e 25 mm de comprimento (K3, SybronEndo), submetidos a variados torques de acionamento e repetidos ciclos de usos em canais simulados, valendo-se de dispositivo apropriado para ensaios dinâmicos. Procurou-se determinar se, além do fator de variação número de uso, há influência relacionada com o torque e, ainda, a possibilidade de interação entre número de uso e torque. Valendo-se motor elétrico acionado à velocidade de 300 rpm foram instrumentados 320 canais simulados, utilizado-se 80 instrumentos divididos em 4 grupos com 20 espécimes cada, de acordo com os torques (0,5 Ncm, 1,0 Ncm, 2,0 Ncm e 6,0 Ncm) a que seriam submetidos. Cada grupo foi subdividido em 4 subgrupos com 5 espécimes, de acordo com o número de usos (1, 3, 5 e 7 ciclos de usos). Todos os instrumentos foram submetidos a ensaio de fadiga cíclica flexural que foi realizado num dispositivo que permitia ao instrumento girar livremente, reproduzindo a instrumentação rotatória num canal curvo (40º e raio de curvatura de 5 mm), simulando o movimento de pecking, onde o instrumento deslizava pelo sulco criado no anel de aço temperado. Foi utilizada peça de mão com contra-ângulo redutor de 16:1, acionado por motor elétrico na velocidade de 300 rpm e torque idêntico ao empregado durante a fase de preparo dos canais simulados. A fratura do instrumento era facilmente detectada pelo sensor, e neste momento o contador e o temporizador paravam imediatamente. Os dados registrados no contador e no temporizador foram tranformados em segundos. Para a avaliação estatística empregou-se ANOVA e o teste t de Student (p<0,01). No que diz respeito ao fator de variação número de uso, não houve diferença estatística significante, enquanto as comparações feitas com o torque de 6,0 Ncm apresentaram valores de t calculado altamente significativo, com p < 0,01. Também não ocorreu interação significante entre os fatores de variação número de usos e torque. Baseado nos resultados deste estudo pode-se concluir que o torque afetou a resistência à fadiga cíclica flexural dos instrumentos rotatórios de NiTi, sendo menor naqueles submetidos à torque elevado, enquanto o número de usos em até 7 vezes não afetou . / The aim of the present study was to evaluate the flexural cyclic fatigue resistance of nickel-titanium rotary instruments, number 25, taper 0,04, and length of 25mm (K3, SybronEndo), when submitted to several torque values and number of uses in simulated canal blocks, by using devices appropriated for dynamic tests. It was tried to detect whether, in addition to the factor number of uses, there would be an influence related to torque, or even the possibility of an interaction between number of uses and torque. The data was collected from 320 simulated canals that were prepared, driven by an electrical motor at 300 rpm, using 80 instruments divided in 4 groups of 20 sample each, based on torque values (0,5 Ncm, 1,0 Ncm, 2,0 Ncm e 6,0 Ncm). Each group was randomly divided in 4 subgroups of 5 samples each, according to the number of uses (1, 3, 5 and 7 cycles). All files were submitted to flexural cyclic fatigue test realized in a device that allows the instrument to freely rotate, reproducing the movement of an instrument rotating in a curved canal (40º angle and 5 mm of radius), simulating the pecking movement, where the instrument slide over the groove created in the hardened steel. An electric motor hand-piece was used with a contra-angle 16:1 reduction set at 300 rpm and torque value identical to that used during preparation of simulated canals. The fracture of the instrument was easily detected at moment which the counter and the timer were immediately stopped. Data collected by the counter and the timer were converted in seconds and analysed by ANOVA and t Student test (p<0.01). In regards to the number of uses factor, there was not a statistically significant difference, while comparisons made with torque value set at 6,0 Ncm showed t values significantly high, with p<0.01. It was not seen any interaction between both variables, number of uses and torque. Based on the results of this investigation, it can be concluded that torque affected the resistance to flexural cyclic fatigue of nickel-titanium rotary instruments, being low on those tested at high torque value; while the factor number of uses up to 7 times did not affect the results.
|
Page generated in 0.0477 seconds