• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Morfometria comparativa in vitro do desgaste dentinário do terço cervical de raízes mésio-vestibulares de primeiros molares superiores produzido por instrumentos rotatórios de aço e de níquel-titânio / In vitro morphometric study of cervical third dentin wearing in upper molar mesiobuccal roots after preparation with iron burs and rotary nickel-titanium instruments

Sá, Júnio Pereira de 30 October 2002 (has links)
No preparo dos canais radiculares, eminentemente os curvos, a abordagem cérvico-apical amplamente difundida promovendo a dilatação da região cervical do canal radicular previamente à atuação de instrumentos em sua região apical constitui técnica e inegavelmente uma forma adequada, tanto do ponto de vista mecânico como microbiológico, de interagir com o espaço endodôntico em busca de uma experiência bem sucedida e previsível. De outra forma, os mais recentes instrumentos endodônticos, muito mais flexíveis em decorrência das novas ligas de baixo módulo de elasticidade empregadas em sua fabricação e dotados de novos índices de conicidade, surgem melhorando tais perspectivas. Desde o surgimento da liga de Níquel-Titânio na Endodontia, na década de oitenta, uma gama imensa de instrumentos desta derivados e para serem empregados com dispositivos mecânicos, eletromecânicos ou pneumocânicos, têm reavivado a esperança de se obter um dispositivo ideal que simulando a cinemática manual supere as limitações operacionais decorrentes, principalmente, da configuração anatômica do canal radicular. Assim, neste experimento verificou-se o desempenho de quatro diferentes recursos técnicos no desgaste da região cervical do canal radicular. Constituíram-se quatro amostras, cada qual composta de 10 espécimes (raízes mésio-vestibulares de primeiros molares superiores), para serem preparadas com (i) Brocas Gates-Glidden, (ii) Brocas Largo-Peeso, (iii) ProFile® .04/.06 & Orifice Shapers e (iv) Pow-R Coronal Shapers. Imagens digitais obtidas antes e após o preparo do canal radicular foram analisadas também digitalmente estudo morfométrico computadorizado avaliando-se a variação das áreas das mesmas em função do desgaste promovido pelos referidos instrumentos. Todos os instrumentos produziram desgaste de ambas as paredes, mesial e distal, do canal radicular na região analisada. A análise estatística das variações de área para o fator parede mesial não mostrou diferenças estatisticamente significantes entre os grupos experimentais para =5%. No entanto quando da comparação dos grupos experimentais para o fator parede distal verificou-se diferenças estatisticamente significantes entre os grupos #1 e #3 para =5%. Ainda, para o fator área total (paredes mesial e distal) verificou-se diferenças estatisticamente signifcantes entre os grupos #3 e #4 para =5%. Concluiu-se que todos os instrumentos testados produzem desgaste tanto da parede mesial como da parede distal do canal radicular e, conseqüentemente, da estrutura dentinária global da região cervical do canal radicular. Por outro lado verificou-se uma tendência da Broca Gates-Glidden em promover maior desgaste da parede distal que o Sistema ProFile® .04/.06 & Orifice Shapers e do Sistema Pow-R Coronal Shapers em promover maior desgaste da estrutura toal que o Sistema ProFile® .04/.06 & Orifice Shapers. / Nowadays is common sense among endodontists that in root canal preparation, mainly the curved ones, the crown-down approach enlarging the cervical third prior instrumentation of the apical third regions provides better interaction between the instrument and the canal walls than the conventional methods. Technically it provides an adequate form to achieve the best and predictable results in cleaning and shaping the root canal system. Additionally the most recent nickel-titanium made endodontic instruments more flexible than the stainless steel instruments and the new taper design have been appeared to improve the endodontic panorama. Since the introduction of the nickel-titanium alloy in Endodontics by Walia et al. in 1988 a number of instruments produced by such alloy in conjunction with the engines new generation have brought new perspectives to deal tridimensionally with the still challenger endodontic space. In this study the performance of four different instruments in the root canal cervical third enlargement was evaluated. Four experimental groups comprised by ten upper molars mesiobuccal roots each were prepared by either (i) Gates bur, (ii) Largo bur, (iii) Profile® .04/.06 & Orifice Shapers or (iv) Pow-R Coronal Shapers. Before and after preparation digitally acquired images were evaluated for area changes within both mesial and distal root canal walls. All instruments produced some amount of wear in both walls and the distals have changed more than the mesials in most times probably due an excentric performance of all evaluated instruments. Comparison of root canal walls wearing among the four experimental groups showed no statistically significant differences (=5%) for mesial wall. However, statistically analyze (=5%) showed significant differences between Experimental Group #1 (Gates-Glidden burs) and Experimental Group #3 (Profile® .04/.06 & Orifice Shapers) for distal walls with the first showing greater wearing than the latter. Also, the results showed statistically significant differences between Experimental Group #4 (Pow-R & Coronal Shapers) and Experimental Group #3 (Profile® & Orifice Shapers) for the entire structure i.e. mesial and distal walls with the first showing the greater than the latter wearing . It was concluded that all tested instruments wear so the mesial as the distal root canal walls. Experimental results have showed that in first upper molaras mesiobuccal roots Gates-Glidden bur for distals and Pow-R nickel-titanium instruments for both walls, i.e. the cervical dentin entire structure, are supposed to wear more root canal cervical third dentin than the others instruments which they were compared.
2

Morfometria comparativa in vitro do desgaste dentinário do terço cervical de raízes mésio-vestibulares de primeiros molares superiores produzido por instrumentos rotatórios de aço e de níquel-titânio / In vitro morphometric study of cervical third dentin wearing in upper molar mesiobuccal roots after preparation with iron burs and rotary nickel-titanium instruments

Júnio Pereira de Sá 30 October 2002 (has links)
No preparo dos canais radiculares, eminentemente os curvos, a abordagem cérvico-apical amplamente difundida promovendo a dilatação da região cervical do canal radicular previamente à atuação de instrumentos em sua região apical constitui técnica e inegavelmente uma forma adequada, tanto do ponto de vista mecânico como microbiológico, de interagir com o espaço endodôntico em busca de uma experiência bem sucedida e previsível. De outra forma, os mais recentes instrumentos endodônticos, muito mais flexíveis em decorrência das novas ligas de baixo módulo de elasticidade empregadas em sua fabricação e dotados de novos índices de conicidade, surgem melhorando tais perspectivas. Desde o surgimento da liga de Níquel-Titânio na Endodontia, na década de oitenta, uma gama imensa de instrumentos desta derivados e para serem empregados com dispositivos mecânicos, eletromecânicos ou pneumocânicos, têm reavivado a esperança de se obter um dispositivo ideal que simulando a cinemática manual supere as limitações operacionais decorrentes, principalmente, da configuração anatômica do canal radicular. Assim, neste experimento verificou-se o desempenho de quatro diferentes recursos técnicos no desgaste da região cervical do canal radicular. Constituíram-se quatro amostras, cada qual composta de 10 espécimes (raízes mésio-vestibulares de primeiros molares superiores), para serem preparadas com (i) Brocas Gates-Glidden, (ii) Brocas Largo-Peeso, (iii) ProFile® .04/.06 & Orifice Shapers e (iv) Pow-R Coronal Shapers. Imagens digitais obtidas antes e após o preparo do canal radicular foram analisadas também digitalmente estudo morfométrico computadorizado avaliando-se a variação das áreas das mesmas em função do desgaste promovido pelos referidos instrumentos. Todos os instrumentos produziram desgaste de ambas as paredes, mesial e distal, do canal radicular na região analisada. A análise estatística das variações de área para o fator parede mesial não mostrou diferenças estatisticamente significantes entre os grupos experimentais para =5%. No entanto quando da comparação dos grupos experimentais para o fator parede distal verificou-se diferenças estatisticamente significantes entre os grupos #1 e #3 para =5%. Ainda, para o fator área total (paredes mesial e distal) verificou-se diferenças estatisticamente signifcantes entre os grupos #3 e #4 para =5%. Concluiu-se que todos os instrumentos testados produzem desgaste tanto da parede mesial como da parede distal do canal radicular e, conseqüentemente, da estrutura dentinária global da região cervical do canal radicular. Por outro lado verificou-se uma tendência da Broca Gates-Glidden em promover maior desgaste da parede distal que o Sistema ProFile® .04/.06 & Orifice Shapers e do Sistema Pow-R Coronal Shapers em promover maior desgaste da estrutura toal que o Sistema ProFile® .04/.06 & Orifice Shapers. / Nowadays is common sense among endodontists that in root canal preparation, mainly the curved ones, the crown-down approach enlarging the cervical third prior instrumentation of the apical third regions provides better interaction between the instrument and the canal walls than the conventional methods. Technically it provides an adequate form to achieve the best and predictable results in cleaning and shaping the root canal system. Additionally the most recent nickel-titanium made endodontic instruments more flexible than the stainless steel instruments and the new taper design have been appeared to improve the endodontic panorama. Since the introduction of the nickel-titanium alloy in Endodontics by Walia et al. in 1988 a number of instruments produced by such alloy in conjunction with the engines new generation have brought new perspectives to deal tridimensionally with the still challenger endodontic space. In this study the performance of four different instruments in the root canal cervical third enlargement was evaluated. Four experimental groups comprised by ten upper molars mesiobuccal roots each were prepared by either (i) Gates bur, (ii) Largo bur, (iii) Profile® .04/.06 & Orifice Shapers or (iv) Pow-R Coronal Shapers. Before and after preparation digitally acquired images were evaluated for area changes within both mesial and distal root canal walls. All instruments produced some amount of wear in both walls and the distals have changed more than the mesials in most times probably due an excentric performance of all evaluated instruments. Comparison of root canal walls wearing among the four experimental groups showed no statistically significant differences (=5%) for mesial wall. However, statistically analyze (=5%) showed significant differences between Experimental Group #1 (Gates-Glidden burs) and Experimental Group #3 (Profile® .04/.06 & Orifice Shapers) for distal walls with the first showing greater wearing than the latter. Also, the results showed statistically significant differences between Experimental Group #4 (Pow-R & Coronal Shapers) and Experimental Group #3 (Profile® & Orifice Shapers) for the entire structure i.e. mesial and distal walls with the first showing the greater than the latter wearing . It was concluded that all tested instruments wear so the mesial as the distal root canal walls. Experimental results have showed that in first upper molaras mesiobuccal roots Gates-Glidden bur for distals and Pow-R nickel-titanium instruments for both walls, i.e. the cervical dentin entire structure, are supposed to wear more root canal cervical third dentin than the others instruments which they were compared.
3

\"Resistência à fadiga cíclica flexural de instrumentos rotatórios de Ni-Ti em razão do uso e do torque\" / Flexural cyclic fatigue resistance of NiTi rotatory instruments due to number of users and torque.

Kawakami, Dirce Akemi Sacaguti 14 March 2007 (has links)
O objetivo do presente estudo foi avaliar a resistência à fadiga cíclica flexural de instrumentos rotatórios de níquel-titânio de número 25, conicidade 0,04 e 25 mm de comprimento (K3, SybronEndo), submetidos a variados torques de acionamento e repetidos ciclos de usos em canais simulados, valendo-se de dispositivo apropriado para ensaios dinâmicos. Procurou-se determinar se, além do fator de variação número de uso, há influência relacionada com o torque e, ainda, a possibilidade de interação entre número de uso e torque. Valendo-se motor elétrico acionado à velocidade de 300 rpm foram instrumentados 320 canais simulados, utilizado-se 80 instrumentos divididos em 4 grupos com 20 espécimes cada, de acordo com os torques (0,5 Ncm, 1,0 Ncm, 2,0 Ncm e 6,0 Ncm) a que seriam submetidos. Cada grupo foi subdividido em 4 subgrupos com 5 espécimes, de acordo com o número de usos (1, 3, 5 e 7 ciclos de usos). Todos os instrumentos foram submetidos a ensaio de fadiga cíclica flexural que foi realizado num dispositivo que permitia ao instrumento girar livremente, reproduzindo a instrumentação rotatória num canal curvo (40º e raio de curvatura de 5 mm), simulando o movimento de pecking, onde o instrumento deslizava pelo sulco criado no anel de aço temperado. Foi utilizada peça de mão com contra-ângulo redutor de 16:1, acionado por motor elétrico na velocidade de 300 rpm e torque idêntico ao empregado durante a fase de preparo dos canais simulados. A fratura do instrumento era facilmente detectada pelo sensor, e neste momento o contador e o temporizador paravam imediatamente. Os dados registrados no contador e no temporizador foram tranformados em segundos. Para a avaliação estatística empregou-se ANOVA e o teste t de Student (p<0,01). No que diz respeito ao fator de variação número de uso, não houve diferença estatística significante, enquanto as comparações feitas com o torque de 6,0 Ncm apresentaram valores de t calculado altamente significativo, com p < 0,01. Também não ocorreu interação significante entre os fatores de variação número de usos e torque. Baseado nos resultados deste estudo pode-se concluir que o torque afetou a resistência à fadiga cíclica flexural dos instrumentos rotatórios de NiTi, sendo menor naqueles submetidos à torque elevado, enquanto o número de usos em até 7 vezes não afetou . / The aim of the present study was to evaluate the flexural cyclic fatigue resistance of nickel-titanium rotary instruments, number 25, taper 0,04, and length of 25mm (K3, SybronEndo), when submitted to several torque values and number of uses in simulated canal blocks, by using devices appropriated for dynamic tests. It was tried to detect whether, in addition to the factor number of uses, there would be an influence related to torque, or even the possibility of an interaction between number of uses and torque. The data was collected from 320 simulated canals that were prepared, driven by an electrical motor at 300 rpm, using 80 instruments divided in 4 groups of 20 sample each, based on torque values (0,5 Ncm, 1,0 Ncm, 2,0 Ncm e 6,0 Ncm). Each group was randomly divided in 4 subgroups of 5 samples each, according to the number of uses (1, 3, 5 and 7 cycles). All files were submitted to flexural cyclic fatigue test realized in a device that allows the instrument to freely rotate, reproducing the movement of an instrument rotating in a curved canal (40º angle and 5 mm of radius), simulating the pecking movement, where the instrument slide over the groove created in the hardened steel. An electric motor hand-piece was used with a contra-angle 16:1 reduction set at 300 rpm and torque value identical to that used during preparation of simulated canals. The fracture of the instrument was easily detected at moment which the counter and the timer were immediately stopped. Data collected by the counter and the timer were converted in seconds and analysed by ANOVA and t Student test (p<0.01). In regards to the number of uses factor, there was not a statistically significant difference, while comparisons made with torque value set at 6,0 Ncm showed t values significantly high, with p<0.01. It was not seen any interaction between both variables, number of uses and torque. Based on the results of this investigation, it can be concluded that torque affected the resistance to flexural cyclic fatigue of nickel-titanium rotary instruments, being low on those tested at high torque value; while the factor number of uses up to 7 times did not affect the results.
4

\"Resistência à fadiga cíclica flexural de instrumentos rotatórios de Ni-Ti em razão do uso e do torque\" / Flexural cyclic fatigue resistance of NiTi rotatory instruments due to number of users and torque.

Dirce Akemi Sacaguti Kawakami 14 March 2007 (has links)
O objetivo do presente estudo foi avaliar a resistência à fadiga cíclica flexural de instrumentos rotatórios de níquel-titânio de número 25, conicidade 0,04 e 25 mm de comprimento (K3, SybronEndo), submetidos a variados torques de acionamento e repetidos ciclos de usos em canais simulados, valendo-se de dispositivo apropriado para ensaios dinâmicos. Procurou-se determinar se, além do fator de variação número de uso, há influência relacionada com o torque e, ainda, a possibilidade de interação entre número de uso e torque. Valendo-se motor elétrico acionado à velocidade de 300 rpm foram instrumentados 320 canais simulados, utilizado-se 80 instrumentos divididos em 4 grupos com 20 espécimes cada, de acordo com os torques (0,5 Ncm, 1,0 Ncm, 2,0 Ncm e 6,0 Ncm) a que seriam submetidos. Cada grupo foi subdividido em 4 subgrupos com 5 espécimes, de acordo com o número de usos (1, 3, 5 e 7 ciclos de usos). Todos os instrumentos foram submetidos a ensaio de fadiga cíclica flexural que foi realizado num dispositivo que permitia ao instrumento girar livremente, reproduzindo a instrumentação rotatória num canal curvo (40º e raio de curvatura de 5 mm), simulando o movimento de pecking, onde o instrumento deslizava pelo sulco criado no anel de aço temperado. Foi utilizada peça de mão com contra-ângulo redutor de 16:1, acionado por motor elétrico na velocidade de 300 rpm e torque idêntico ao empregado durante a fase de preparo dos canais simulados. A fratura do instrumento era facilmente detectada pelo sensor, e neste momento o contador e o temporizador paravam imediatamente. Os dados registrados no contador e no temporizador foram tranformados em segundos. Para a avaliação estatística empregou-se ANOVA e o teste t de Student (p<0,01). No que diz respeito ao fator de variação número de uso, não houve diferença estatística significante, enquanto as comparações feitas com o torque de 6,0 Ncm apresentaram valores de t calculado altamente significativo, com p < 0,01. Também não ocorreu interação significante entre os fatores de variação número de usos e torque. Baseado nos resultados deste estudo pode-se concluir que o torque afetou a resistência à fadiga cíclica flexural dos instrumentos rotatórios de NiTi, sendo menor naqueles submetidos à torque elevado, enquanto o número de usos em até 7 vezes não afetou . / The aim of the present study was to evaluate the flexural cyclic fatigue resistance of nickel-titanium rotary instruments, number 25, taper 0,04, and length of 25mm (K3, SybronEndo), when submitted to several torque values and number of uses in simulated canal blocks, by using devices appropriated for dynamic tests. It was tried to detect whether, in addition to the factor number of uses, there would be an influence related to torque, or even the possibility of an interaction between number of uses and torque. The data was collected from 320 simulated canals that were prepared, driven by an electrical motor at 300 rpm, using 80 instruments divided in 4 groups of 20 sample each, based on torque values (0,5 Ncm, 1,0 Ncm, 2,0 Ncm e 6,0 Ncm). Each group was randomly divided in 4 subgroups of 5 samples each, according to the number of uses (1, 3, 5 and 7 cycles). All files were submitted to flexural cyclic fatigue test realized in a device that allows the instrument to freely rotate, reproducing the movement of an instrument rotating in a curved canal (40º angle and 5 mm of radius), simulating the pecking movement, where the instrument slide over the groove created in the hardened steel. An electric motor hand-piece was used with a contra-angle 16:1 reduction set at 300 rpm and torque value identical to that used during preparation of simulated canals. The fracture of the instrument was easily detected at moment which the counter and the timer were immediately stopped. Data collected by the counter and the timer were converted in seconds and analysed by ANOVA and t Student test (p<0.01). In regards to the number of uses factor, there was not a statistically significant difference, while comparisons made with torque value set at 6,0 Ncm showed t values significantly high, with p<0.01. It was not seen any interaction between both variables, number of uses and torque. Based on the results of this investigation, it can be concluded that torque affected the resistance to flexural cyclic fatigue of nickel-titanium rotary instruments, being low on those tested at high torque value; while the factor number of uses up to 7 times did not affect the results.

Page generated in 0.0858 seconds