• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • 1
  • 1
  • Tagged with
  • 22
  • 14
  • 13
  • 11
  • 8
  • 8
  • 8
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Caracterização de juntas soldadas por Arame Tubular com proteção gasosa do aço ferrítico ASTM A335 P91, antes e após situação de duplo reparo. / Characterization of ASTM A335 grade P91 steel joints welded by Flux-Cored Arc Welding (FCAW) with shielding gas, before and after double repair situation.

Diego Teixeira Pedro 22 October 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Pouco se sabe a respeito das consequências da operação de reparo nas propriedades mecânicas e metalúrgicas das juntas do aço ASTM A335 grau P91 soldadas por Arame Tubular. Neste trabalho foi realizado um estudo para analisar e caracterizar juntas de um tubo do aço P91 soldadas pelo processo Arame Tubular com proteção gasosa, antes e após situação de duplo reparo. Foram utilizadas técnicas de microscopia eletrônica de varredura (MEV), análise química semiquantitativa por EDS (Energy Dispersive Spectroscopy), microscopia óptica (MO), além da obtenção de medidas de microdureza Vickers e realização de ensaios de impacto e tração à temperatura ambiente. A macrografia revelou a existência de uma nova zona termicamente afetada formada no centro da junta reparada e a análise micrográfica mostrou que esta zona apresentou uma pequena tendência a formação de grãos menores do que na zona de fusão que sofreu reparo, além disso, a região tinha grãos colunares que não são característicos de uma zona termicamente afetada e quantidade de carbonetos menor comparativamente. Não houve variações significativas nos valores de tração e microdureza. Os ensaios de impacto revelaram baixos valores de energia absorvida na zona de fusão do 2 reparo, no entanto, todas as outras zonas avaliadas das juntas com e sem reparo apresentaram valores dentro das especificações. / Little is known about the consequences of the repair operation on the mechanical and metallurgical properties of ASTM A335 grade P91 steel joints welded by Flux-Cored Arc Welding (FCAW). In this work, a study was made to analyze and characterize joints of P91 steel tube, welded by FCAW with shielding gas, before and after double repair situation. Techniques of scanning electron microscopy (SEM), chemical analysis by semi-quantitative EDS (Energy Dispersive Spectroscopy) and optical microscopy (OM) were used, in addition, Vickers microhardness measurements, impact and tensile tests at room temperature, were carried out. The macrography revealed the existence of a new heat affected zone formed in the center of the repaired joint and the micrographic analysis showed that this zone has a tendency to formation of smaller grains compared to the repaired fusion zone, furthermore, the region has columnar grains which are not characteristics of a heat affected zone and comparatively lesser amounts of carbides. There were no significant variations in the tensile and hardness values. Impact tests showed low values of absorbed energy in the fusion zone of the second repair; however, all other evaluated zones, with and without repair, had values within specifications.
12

Análise da tenacidade de uma junta soldada de um aço resistente à abrasão da série 450 HB

Costa, Vagner Machado January 2014 (has links)
Aços resistentes à abrasão possuem uma dureza elevada, sendo amplamente utilizados em aplicações em que o componente ou estrutura é submetido a situações em que é exigida alta resistência mecânica e resistência ao desgaste. Este tipo de aço pode ser aplicado para fabricação de implementos rodoviários, implementos agrícolas, montagem de altos fornos e na indústria de mineração. O presente trabalho visa analisar a influência da baixa temperatura na tenacidade de uma junta de aço resistente à abrasão da série 450HB soldado através do processo ao arco elétrico com arame tubular (Flux-Cored Arc Welding- FCAW). Para tanto foram realizados ensaios de tenacidade ao impacto (Charpy-V) no metal base, metal de solda e ZAC nas temperaturas de 25ºC, 0ºC, -20ºC, -60ºC, -80ºC e -100ºC com o objetivo de levantar a curva de transição dúctil-frágil para cada uma dessas regiões. Também foram realizados ensaios para medição da tenacidade à fratura pelo parâmetro CTOD (Crack Tip Opening Displacement) nas regiões do metal base, metal de solda e ZAC nas temperaturas 25ºC, 0ºC, -20ºC. Adicionalmente foram realizados perfis de microdureza Vickers, dureza Brinell, análise química do metal de base e do metal de solda, caracterização metalográfica (macrografia e micrografias) e análises fractográficas a fim de complementar o estudo da junta soldada. Os resultados mostram melhor desempenho do metal base em relação ao ensaio de impacto, entretanto, o metal de solda apresentou melhores resultados de tenacidade à fratura. A região da ZAC apresentou o pior desempenho entre as regiões em ambos os ensaios de tenacidade realizados. / Abrasion resistant steels have a high hardness, being widely used in applications where the component or structure is subjected to situations where high strength and wear resistance is required. This type of steel can be applied to the production of road equipment, agricultural implements, mounting blast furnaces and in the mining industry. The present work analyzes the influence of low temperature on the toughness of an abrasion resistant steel joint of 450HB series welded through the FCAW (Flux Cored Arc Welding-FCAW) process. It was performed tests of impact toughness (Charpy-V) in the base metal, weld metal and HAZ in the temperatures of 25ºC, 0ºC, -20ºC, -60ºC, -80ºC e -100ºC with the objective to raise the ductile-fragile transition curve for each one of these regions. Tests for measurement of fracture toughness by CTOD (Crack Tip Opening Displacement) parameter in the regions of the base metal, weld metal and HAZ in the temperatures of 25 º C, 0 º C, -20 º C were also performed. In addition, Vickers microhardness profile, Brinell hardness, chemical analysis of the base metal and weld metal, metallographic characterization (macrograph and micrographs) and fractography analysis were performed to complement the study of the welded joint. The results show better performance of the base metal in relation to the impact test, however, the weld metal showed a better fracture toughness. The region of the HAZ showed the worst performance among regions in both toughness tests performed.
13

Caracterização de juntas soldadas por Arame Tubular com proteção gasosa do aço ferrítico ASTM A335 P91, antes e após situação de duplo reparo. / Characterization of ASTM A335 grade P91 steel joints welded by Flux-Cored Arc Welding (FCAW) with shielding gas, before and after double repair situation.

Diego Teixeira Pedro 22 October 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Pouco se sabe a respeito das consequências da operação de reparo nas propriedades mecânicas e metalúrgicas das juntas do aço ASTM A335 grau P91 soldadas por Arame Tubular. Neste trabalho foi realizado um estudo para analisar e caracterizar juntas de um tubo do aço P91 soldadas pelo processo Arame Tubular com proteção gasosa, antes e após situação de duplo reparo. Foram utilizadas técnicas de microscopia eletrônica de varredura (MEV), análise química semiquantitativa por EDS (Energy Dispersive Spectroscopy), microscopia óptica (MO), além da obtenção de medidas de microdureza Vickers e realização de ensaios de impacto e tração à temperatura ambiente. A macrografia revelou a existência de uma nova zona termicamente afetada formada no centro da junta reparada e a análise micrográfica mostrou que esta zona apresentou uma pequena tendência a formação de grãos menores do que na zona de fusão que sofreu reparo, além disso, a região tinha grãos colunares que não são característicos de uma zona termicamente afetada e quantidade de carbonetos menor comparativamente. Não houve variações significativas nos valores de tração e microdureza. Os ensaios de impacto revelaram baixos valores de energia absorvida na zona de fusão do 2 reparo, no entanto, todas as outras zonas avaliadas das juntas com e sem reparo apresentaram valores dentro das especificações. / Little is known about the consequences of the repair operation on the mechanical and metallurgical properties of ASTM A335 grade P91 steel joints welded by Flux-Cored Arc Welding (FCAW). In this work, a study was made to analyze and characterize joints of P91 steel tube, welded by FCAW with shielding gas, before and after double repair situation. Techniques of scanning electron microscopy (SEM), chemical analysis by semi-quantitative EDS (Energy Dispersive Spectroscopy) and optical microscopy (OM) were used, in addition, Vickers microhardness measurements, impact and tensile tests at room temperature, were carried out. The macrography revealed the existence of a new heat affected zone formed in the center of the repaired joint and the micrographic analysis showed that this zone has a tendency to formation of smaller grains compared to the repaired fusion zone, furthermore, the region has columnar grains which are not characteristics of a heat affected zone and comparatively lesser amounts of carbides. There were no significant variations in the tensile and hardness values. Impact tests showed low values of absorbed energy in the fusion zone of the second repair; however, all other evaluated zones, with and without repair, had values within specifications.
14

Análise da tenacidade de uma junta soldada de um aço resistente à abrasão da série 450 HB

Costa, Vagner Machado January 2014 (has links)
Aços resistentes à abrasão possuem uma dureza elevada, sendo amplamente utilizados em aplicações em que o componente ou estrutura é submetido a situações em que é exigida alta resistência mecânica e resistência ao desgaste. Este tipo de aço pode ser aplicado para fabricação de implementos rodoviários, implementos agrícolas, montagem de altos fornos e na indústria de mineração. O presente trabalho visa analisar a influência da baixa temperatura na tenacidade de uma junta de aço resistente à abrasão da série 450HB soldado através do processo ao arco elétrico com arame tubular (Flux-Cored Arc Welding- FCAW). Para tanto foram realizados ensaios de tenacidade ao impacto (Charpy-V) no metal base, metal de solda e ZAC nas temperaturas de 25ºC, 0ºC, -20ºC, -60ºC, -80ºC e -100ºC com o objetivo de levantar a curva de transição dúctil-frágil para cada uma dessas regiões. Também foram realizados ensaios para medição da tenacidade à fratura pelo parâmetro CTOD (Crack Tip Opening Displacement) nas regiões do metal base, metal de solda e ZAC nas temperaturas 25ºC, 0ºC, -20ºC. Adicionalmente foram realizados perfis de microdureza Vickers, dureza Brinell, análise química do metal de base e do metal de solda, caracterização metalográfica (macrografia e micrografias) e análises fractográficas a fim de complementar o estudo da junta soldada. Os resultados mostram melhor desempenho do metal base em relação ao ensaio de impacto, entretanto, o metal de solda apresentou melhores resultados de tenacidade à fratura. A região da ZAC apresentou o pior desempenho entre as regiões em ambos os ensaios de tenacidade realizados. / Abrasion resistant steels have a high hardness, being widely used in applications where the component or structure is subjected to situations where high strength and wear resistance is required. This type of steel can be applied to the production of road equipment, agricultural implements, mounting blast furnaces and in the mining industry. The present work analyzes the influence of low temperature on the toughness of an abrasion resistant steel joint of 450HB series welded through the FCAW (Flux Cored Arc Welding-FCAW) process. It was performed tests of impact toughness (Charpy-V) in the base metal, weld metal and HAZ in the temperatures of 25ºC, 0ºC, -20ºC, -60ºC, -80ºC e -100ºC with the objective to raise the ductile-fragile transition curve for each one of these regions. Tests for measurement of fracture toughness by CTOD (Crack Tip Opening Displacement) parameter in the regions of the base metal, weld metal and HAZ in the temperatures of 25 º C, 0 º C, -20 º C were also performed. In addition, Vickers microhardness profile, Brinell hardness, chemical analysis of the base metal and weld metal, metallographic characterization (macrograph and micrographs) and fractography analysis were performed to complement the study of the welded joint. The results show better performance of the base metal in relation to the impact test, however, the weld metal showed a better fracture toughness. The region of the HAZ showed the worst performance among regions in both toughness tests performed.
15

Avaliação da tenacidade à fratura da zona afetada pelo calor (ZAC) do aço API 5L X80 soldado pelos processos SMAW e FCAW / Evaluation of fracture toughness of the heat affected zone (HAZ) of API 5L X80 steel welded SMAW and FCAW.

Paulo Eduardo Alves Fernandes 12 December 2011 (has links)
O presente trabalho investiga a soldabilidade dos aços ARBL (Alta Resistência e Baixa Liga) API 5L X80) e a tenacidade da ZAC (Zona Afetada pelo Calor), assim como a sua correlação com o ensaio CTOD (Crack Tip Opening Displacement) nos processos de soldagem Eletrodo Revestido estudado por Silva [2009] e GMAW-STT® (Gas Metal Arc Welding Surface Tension Transfer®) no passe de raiz com FCAW (Flux Core Arc Welding) para os passes de enchimento e acabamento. Foram utilizados corpos de provas SENB em chapa com espessura de 19 mm e chanfro em ½ V, onde ficaria mais fácil a localização do entalhe na região de grãos grosseiros na zona afetada pelo calor (parte reta do chanfro). Ensaio de tração e impacto Charpy entalhe com 1/2 V foram utilizados para determinar as propriedades mecânicas e de impacto do material testado. Foram comparados os processos SMAW (Eletrodo Revestido), muito utilizado para a soldagem de gasodutos e oleodutos, com os processos GMAW-STT® e FCAW, que têm maior produtividade do que o SMAW. A soldabilidade dos aços ARBL está associada às regiões da ZAC (Zona Afetada pelo Calor) que, por sua vez, encontra-se correlacionado com o processo de soldagem, composição química e com os parâmetros de soldagem utilizados durante o processo de solda, sendo que a qualificação dos procedimentos geralmente não exige o ensaio de tenacidade, como o CTOD. / This work studies HSLA steels (High Strength Low Alloy) API 5L X80 weldability, HAZ (Heat Affected Zone) fracture behavior and their relationship with the CTOD test (Crack Tip Opening Displacement) on the welding processes SMAW (Shielded Metal Arc Welding) studied by Silva [2009] and GMAW-STT® (Gas Metal Arc Welding Surface Tension Transfer®) in the root pass with FCAW (Flux Core Arc Welding) others welding passes. There were used 19 mm width SENB plate samples with a half V groove, where would be easier to locate the crack in the HAZ coarse grain region. Conventional tensile and Charpy V-Notch were performed to determinate mechanical and impact properties of the tested materials. SMAW process, widely used for gas and oil pipelines welding, was compared with GMAW and FCAW processes which have a better productivity than the first one. The HSLA steels weldability is related with HAZ region which also depends on welding process, its parameters and material chemical composition. Normally is not necessary to perform toughness test as CTOD test to evaluate the procedures.
16

Análise da tenacidade de uma junta soldada de um aço resistente à abrasão da série 450 HB

Costa, Vagner Machado January 2014 (has links)
Aços resistentes à abrasão possuem uma dureza elevada, sendo amplamente utilizados em aplicações em que o componente ou estrutura é submetido a situações em que é exigida alta resistência mecânica e resistência ao desgaste. Este tipo de aço pode ser aplicado para fabricação de implementos rodoviários, implementos agrícolas, montagem de altos fornos e na indústria de mineração. O presente trabalho visa analisar a influência da baixa temperatura na tenacidade de uma junta de aço resistente à abrasão da série 450HB soldado através do processo ao arco elétrico com arame tubular (Flux-Cored Arc Welding- FCAW). Para tanto foram realizados ensaios de tenacidade ao impacto (Charpy-V) no metal base, metal de solda e ZAC nas temperaturas de 25ºC, 0ºC, -20ºC, -60ºC, -80ºC e -100ºC com o objetivo de levantar a curva de transição dúctil-frágil para cada uma dessas regiões. Também foram realizados ensaios para medição da tenacidade à fratura pelo parâmetro CTOD (Crack Tip Opening Displacement) nas regiões do metal base, metal de solda e ZAC nas temperaturas 25ºC, 0ºC, -20ºC. Adicionalmente foram realizados perfis de microdureza Vickers, dureza Brinell, análise química do metal de base e do metal de solda, caracterização metalográfica (macrografia e micrografias) e análises fractográficas a fim de complementar o estudo da junta soldada. Os resultados mostram melhor desempenho do metal base em relação ao ensaio de impacto, entretanto, o metal de solda apresentou melhores resultados de tenacidade à fratura. A região da ZAC apresentou o pior desempenho entre as regiões em ambos os ensaios de tenacidade realizados. / Abrasion resistant steels have a high hardness, being widely used in applications where the component or structure is subjected to situations where high strength and wear resistance is required. This type of steel can be applied to the production of road equipment, agricultural implements, mounting blast furnaces and in the mining industry. The present work analyzes the influence of low temperature on the toughness of an abrasion resistant steel joint of 450HB series welded through the FCAW (Flux Cored Arc Welding-FCAW) process. It was performed tests of impact toughness (Charpy-V) in the base metal, weld metal and HAZ in the temperatures of 25ºC, 0ºC, -20ºC, -60ºC, -80ºC e -100ºC with the objective to raise the ductile-fragile transition curve for each one of these regions. Tests for measurement of fracture toughness by CTOD (Crack Tip Opening Displacement) parameter in the regions of the base metal, weld metal and HAZ in the temperatures of 25 º C, 0 º C, -20 º C were also performed. In addition, Vickers microhardness profile, Brinell hardness, chemical analysis of the base metal and weld metal, metallographic characterization (macrograph and micrographs) and fractography analysis were performed to complement the study of the welded joint. The results show better performance of the base metal in relation to the impact test, however, the weld metal showed a better fracture toughness. The region of the HAZ showed the worst performance among regions in both toughness tests performed.
17

Estudo da soldabilidade do tubo API 5L X80 utilizando os processos de soldagem eletrodo revestido e MAG com transferência controlada na raiz e enchimento com arame tubular autoprotegido. / Study of weldability of API 5L X80 steel pipe using the welding processes of shielded metal arc welding and GMAW-CT in the root pass and self shielded flux cored in filling and finishing passes.

Jaime Casanova Soeiro Junior 05 April 2013 (has links)
Na indústria de petróleo e gás as tubulações são formas eficientes de transportar esses produtos ou seus derivados das regiões de exploração para as refinarias e em alguns casos até o consumidor. O principal tipo de aço utilizado na fabricação dessas tubulações são os aços ARBL que devido à boa relação entre resistência à tração e tenacidade a baixas temperaturas geram uma boa relação custo/benefício na utilização e na montagem de tubulações. Neste trabalho é apresentado um estudo sobre a soldabilidade do tubo API 5L X80 construído com aço ARBL. Os corpos-de-prova utilizados foram anéis de 508 mm de diâmetro externo com espessura de parede de 19,0 mm. A soldagem foi executada com o processo eletrodo revestida no experimento 1, em um par de anéis, e o outro par de anéis foi soldado, na raiz, com o processo de soldagem MAG-TC e nos passes de enchimento e acabamento foi utilizado o processo arame tubular auto-protegido. Os resultados dos ensaios de resistência à tração, dobramento lateral e de Nick-Break demonstram que ambos os procedimentos de soldagem são qualificados pela norma API 1104. Associando o resultado do ensaio de Charpy V a 0°C e associando-o a quantificação das frações volumétricas de microconstituintes MA e a caracterização microestrutural é possível observar que os valores de energia absorvida na ZAC tem maior relação com o mecanismo de refino de grão, que melhora os valores obtidos, do que com a quantidade de fração volumétrica do microconstituinte MA. / In the oil and gas industries, pipelines are efficient ways of transporting these products, or its derivatives, from exploration regions to refineries and, in some cases, up to the final consumer. The main type of steel used in manufacturing these pipelines are HSLA steels that, due to the good relationship between tensile strength and toughness at low temperatures, create a cost/benefit ratio in the use and installation of these pipelines. This paper presents a study on the weldability of API 5L X80 HSLA pipe steel. The samples used were pipe rings with 508 mm outside diameter and a wall thickness of 19.0 mm. The root welding process was performed using SMAW in Experiment 1 with filing and finishing passes with SMAW. In the second experiment, the root pass were welded with GMAW-CT, and filling and finishing passes with FCAW-SS. Tensile test results, lateral bending tests and \'Nick-Break\' tests showed that both welding procedures were qualified according to API 1104 Standard. Associating these results with Charpy V test at 0°C and with quantification of volume fractions of MA microconstituent is possible to observe that the values of absorbed energy in the HAZ are more closely related to the mechanism of grain refinement, which improves the values obtained with the volume fraction of the amount of microconstituent MA.
18

Estudo da soldabilidade do tubo API 5L X80 utilizando os processos de soldagem: MAG com transferência controlada e eletrodo tubular. / Study of the weldability of API 5L X80 pipe using the gmaw-stt and fcaw welding process.

Rocha, David Bellentani 11 March 2010 (has links)
Os tubos API 5L X80, construídos com aços alta resistência e baixa liga, são especificados para a construção de dutos para transporte de petróleo e derivados sob alta pressão, com conseqüente redução no peso dos tubos. O processo mais empregado para a soldagem circunferencial de tubos em campo no Brasil é o processo com eletrodo revestido, tanto para o passe de raiz quanto para os passes de enchimento. Uma alternativa para o passe de raiz é o processo de soldagem MAG com Transferência Controlada (MAG-TC), enquanto que o enchimento pode ser feito com o processo de soldagem utilizando eletrodo tubular (AT), tanto o auto-protegido (AT-AP) como o com proteção gasosa (AT-PG). Esta combinação de processos (MAG-TC + AT) apresenta-se como um promissor substituto do processo de soldagem com eletrodo revestido, reunindo alta qualidade do metal de solda depositado e alta produtividade. O objetivo deste trabalho é estudar a soldabilidade do tubo API 5L X80 nacional, com 508 mm (20\") de diâmetro e 19 mm (3/4\") de espessura, comparando-se duas combinações de processos de soldagem circunferencial: MAG-TC + AT-PG e MAG-TC + AT-AP. A soldagem foi realizada com o arame ER80S-G no passe de raiz e processo MAG-TC com proteção de CO2. O enchimento foi feito com os arames E101T1-GM-H8 (com proteção gasosa) e E91T8-G (auto-protegido). Foram fixadas as temperaturas de pré-aquecimento (150 °C) e interpasse (250 °C) para ambas combinações de processos de soldagem. As juntas foram caracterizadas utilizando-se: análise química, saturação magnética, metalografia óptica e eletrônica de varredura e ensaios mecânicos: dureza Vickers, tração, dobramento, nick-break e ensaio de impacto a 0°C. Foi seguido como referência os requisitos técnicos básicos para a qualificação de um procedimento de soldagem conforme a norma API 1104. Os resultados mostraram que, segundo os critérios da norma API 1104, apenas uma das combinações de processos foi aprovada, sendo a outra reprovada no ensaio nick-break devido à ocorrência de falta de fusão na raiz de um dos quadrantes. O processo MAG-TC na raiz exige uma habilidade específica do soldador. / API 5L X80 pipes, built with high strength - low alloy steel, are specified for the construction of pipelines to transport oil and oil products under high pressure, with consequent reduction in weight of the tubes. The most often pipeline construction used for welding circumferential pipe field in Brazil is the SMAW process, for root and filling passes. An alternative welding process to the root pass is the GMAW-STT® process, while the filling passes can be welded with FCAW-G (Flux Cored Arc Welding with Gas shielding) and FCAWS (Flux Cored Arc Welding with Self shielding). This combination of processes (GMAW-STT® + FCAW) is presented as a promising substitute for the SMAW process, bringing high-quality weld metal deposited and high productivity. The objective of this work is to study the weldability of the Brazilian API 5L X80 pipe, with 508 mm (20 inches) in diameter and 19 mm (3 / 4 inch) thick, comparing the two combinations of circumferential welding processes: GMAWSTT ® + FCAW-G and GMAW-STT® + FCAW-S. The welding was done with the ER80S-G wire in the root pass and process GMAW-STT® using pure CO2 as shielding gas. The filling passes were made with the wires E101T1-GM-H8 for FCAW-G and E91T8-G for FCAW-S. Preheat and interpass temperatures were kept constant, respectively 150 °C and 250 °C for both welding processes combinations. The joints were characterized using: chemical analysis, magnetic saturation, optical metallography and scanning electron microscopy and mechanical tests such as: Vickers hardness, tensile, bending, nick-break and Charpy V test at 0°C. It was followed API 1104 standard as reference to the basic technical requirements for the qualification of a welding procedures. The results showed that, according to the criteria of the API 1104 standard, only one combination of the two processes was approved. The other combination was reproved in the nick-break test due to lack of fusion occurred in one of the quadrants in the root pass. The GMAW-STT® process at the root pass requires a specific skill of the welder.
19

Análise Comparativa dos Processos de Soldagem GMAW e FCAW com Transferência Metálica por Curto-Circuito na Posição Horizontal / Comparative Analysis of Processes Welding FCAW and GMAW Metal Transfer to Short-Circuit in a Horizontal Position

Souza, Claudio Ivanei de 29 August 2011 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / The process of welding with solid wire (GMAW) and cored wire (FCAW) processes that compete in quality, productivity and operational, need reliable information of its main features and applications for a given welding condition. Thus, the goal is to compare the capability of each process in the horizontal welding carbon steel ABNT 1020, varying the type of shielding gas on the same level of welding current and voltage to maintain a constant deposition rate per unit length. For this study we used the wire E71T-1 and ER 70S-6 under the shielding 100% CO2 gas and Ar +25% CO2 in two bands of four current and voltage ranges. We evaluated the stability of metal transfer mode and short-circuit capacity through income and presence of deposit discontinuity. In general, the process using a tubular wire had a higher deposition rate compared to solid wire, but with lower performance deposit. It was noted that, the same current range and with increasing voltage range, there was a change in transfer characteristics for both processes. With regard to straining of the weld beads, the solid wire bends showed better with lower voltage ranges. Cored wire for the values of runoff was similar, with a condition better than solid wire for higher values of welding voltage (region of predominance of metal transfer carried by the flow without short circuit). The shielding gas 100% CO2, for both processes, which was provided better performance and higher deposit with transfer voltage ranges with a predominance of short-circuit. / Os processos de soldagem com arame maciço (GMAW) e arame tubular (FCAW), processos que competem entre si em termos de qualidade, produtividade e operacionalidade, necessitam de informações seguras de suas principais características e aplicações para uma determinada condição de soldagem. Desta forma, o objetivo deste trabalho é comparar a potencialidade de cada processo na soldagem horizontal de aço carbono ABNT 1020, variando o tipo de gás de proteção sob um mesmo nível de corrente e tensão de soldagem, mantendo constante a taxa de deposição por unidade de comprimento. Para a realização deste estudo foram utilizados os arames E71T-1 e ER 70S-6 sob as proteções gasosas 100%CO2 e Ar+25%CO2 em duas faixas de corrente e quatro faixas de tensão. As características avaliadas foram a regularidade de transferência metálica no modo curto-circuito e a capacidade produtiva através do rendimento de depósito e presença descontinuidades. De maneira geral, o processo utilizando arame tubular apresentou maior taxa de deposição em relação ao arame maciço, porém com menor rendimento de depósito. Também se observou que, na mesma faixa de corrente e com a elevação da faixa de tensão, houve uma mudança nas características de transferências para os dois processos. Em relação ao escorrimento dos cordões de solda, o arame maciço apresentou melhores cordões com menores faixas de tensão. Para o arame tubular os valores dos escorrimentos foram próximos, tendo uma condição melhor que o arame maciço para maiores valores de tensão de soldagem (região de predominância de transferência metálica conduzida pelo fluxo sem curto-circuito). O gás de proteção 100%CO2, para ambos os processos, foi o que proporcionou melhor rendimento de depósito e maiores faixas de tensão com transferência com predominância de curto-circuito. / Mestre em Engenharia Mecânica
20

Welding on UNS S32750 superduplex stainless steel plates employed FCAW process / Soldagem em chapas de aÃos inoxidÃveis superduplex UNS S32750 utilizando o processo arame tubular

AntÃnio Rodolfo Paulino Pessoa 17 April 2015 (has links)
AgÃncia Nacional do PetrÃleo / Superduplex stainless steels (SDSS) may be defined as a family of steels having a two-phase ferritic-austenitic microstructure and the good mechanical properties and high corrosion resistance of this alloy are attributed to this microestrutural balance. These excellent qualities attribute to SDSS great employability in the oil sector, where manufacturing and equipment maintenance are performed by welding, which if not executed properly, can have a negative effect on the metallurgical properties and this problem becomes more critical in multipass welding due to repeated thermal cycles. Among the several welding processes employed in the welding of SDSS, fell to this work was to evaluate the FCAW process in multipass welding joints of SDSS UNS S32750, regarding the selection of appropriate welding parameters and the influence of these parameters on microstructural transformations, mechanical properties and corrosion resistance of welded joints. Then, this work was divided into three steps: Stage 1 was the characterization of the base metal in as-received condition. In Stage 2, weldings were accomplished using a bead on plate (BOP) technique to determine the control factors and their levels to be used in the subsequent stage, in which an experimental design was conducted by Taguchi method with Alloy, Stick out, Shielding gas, welding gun orientation, Arc oscillation, Energy technique and Heat input used as control factors and quality characteristics were evaluated the ratio R/L, bead penetration, ferrite content and inclusions content and microhardness. Finally, in Stage 3 were performed multipass welding in joints and afterwards was executed: A microstructural characterization in three regions of Fusion Zone (Root, Filler and Cap) and Heat Affected Zone by Optical Microscopy (OM) and Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray Spectroscopy (EDS) and were also performed a measurement of the ferrite content; measurement of inclusions content; microhardness tests and Critical Temperature Pitting (CPT) tests according to ASTM G150. The results showed, ferrite contents ranging from 44% and 54.9% and their highest values were observed when employed the alloy 2507, heat input of 1.6 kJ/mm and pulsed current. The lowest inclusions contents were obtained by using of shielding gas with the mixture of 96%Ar + 4%CO2 (Stage 2) and heat input of 1,6kJ/mm (Stage 3). The microhardness values in FZ of joints were not affected significantly by any of the control factors. Already, the results of CPT tests showed that pits nucleated preferentially within α, at α/γ grain boundaries and at interfaces areas between large diameter inclusions and the metallic matrix and propagated predominantly into α phase. The CPT values ranging from 47 ÂC to 78 ÂC, with highest were obtained for the alloy 2507, heat input of 1.6 kJ/mm and continuous current into Root region and for the alloy 2507, heat input of 1.6 kJ/mm and the pulsed current in Filler and Cap regions. From the three regions of FZs, the Root showed the best results with no defects, satisfactory ferrite contents, lowest inclusions contents and highest CPT values. / Os aÃos inoxidÃveis superduplex (AISDs) possuem uma microestrutura bifÃsica constituÃda por ferrita (α) e austenita (γ) e quando devidamente balanceadas conferem ao material, boas propriedades mecÃnicas e elevada resistÃncia à corrosÃo. Qualidades que atribuem aos AISDs grande empregabilidade no setor petrolÃfero, onde a fabricaÃÃo e manutenÃÃo de equipamentos sÃo realizadas por soldagem e se executada inadequadamente, pode afetar negativamente as propriedades destes aÃos, o que se torna mais crÃtico quando hà a imposiÃÃo de inÃmeros ciclos tÃrmicos durante uma soldagem multipasse. Dentre os inÃmeros processos de soldagem utilizados na soldagem dos AISDS, coube a este trabalho avaliar o processo arame tubular na soldagem multipasse em juntas do AISD UNS S32750, levando em consideraÃÃo a seleÃÃo dos parÃmetros de soldagem adequados, bem como a influÃncia destes parÃmetros nas alteraÃÃes microestruturais, microdureza e resistÃncia à corrosÃo das juntas soldadas. Desta forma, dividiu-se este trabalho em trÃs etapas: A Etapa 1 consistiu na caracterizaÃÃo do metal de base na condiÃÃo como recebido. Jà na Etapa 2 foram realizadas soldagens por simples deposiÃÃo para selecionar os fatores de controle e seus nÃveis a serem utilizados na etapa posterior, e o planejamento experimental foi realizado pelo mÃtodo Taguchi com a Liga, GÃs, DBCP, TÃcnica da Tocha, Tecimento, TÃcnica de Energia e Energia foram utilizados como fatores de controle e como variÃveis de resposta escolheu-se a razÃo R/L, a penetraÃÃo, a fraÃÃo de ferrita, a fraÃÃo das inclusÃes e a microdureza. E por fim, na Etapa 3 foram realizadas soldagens multipasse em juntas e posteriormente efetuou-se: uma caracterizaÃÃo microestrutural em trÃs regiÃes da Zona Fundida (Raiz, Enchimento e Acabamento) e Zona Afetada pelo Calor atravÃs de Microscopia Ãtica (MO) e Microscopia EletrÃnica de Varredura (MEV) e Espectroscopia de Energia Dispersiva de Raios X (EDS); quantificaÃÃo da fraÃÃo de ferrita; quantificaÃÃo da fraÃÃo das inclusÃes; ensaios de microdureza e uma avaliaÃÃo da resistÃncia à corrosÃo por pites atravÃs dos ensaios de temperatura crÃtica de pite (CPT) seguindo a norma ASTM G150. Como resultados, obteve-se fraÃÃes de ferrita entre 44% e 54,9% com seus maiores valores observados quando utilizou-se a liga 2507, a energia de 1,6 kJ/mm e a corrente contÃnua pulsada. As menores fraÃÃes das inclusÃes foram obtidas pela utilizaÃÃo do gÃs de proteÃÃo com 96%Ar + 4%CO2 (Etapa 2) e da energia de 1,6kJ/mm (Etapa 3). As microdurezas na ZF das juntas nÃo apresentaram diferenÃas significativas. Jà os ensaios de CPT revelaram que os pites nuclearam preferencialmente no interior da α, nos contornos α/γ e nas interfaces entre inclusÃes de grande diÃmetro e a matriz metÃlica, propagando-se exclusivamente atravÃs da α. Os valores de CPT apresentaram uma faixa de 47ÂC à 78ÂC, com os maiores valores obtidos para a liga 2507, a energia de 1,6 kJ/mm e a corrente contÃnua constante na regiÃo da Raiz e nas regiÃes do Enchimento e Acabamento ao utilizar-se a liga 2507, a energia de 1,6 kJ/mm e a corrente contÃnua pulsada. Dentre as trÃs regiÃes das ZFs, a Raiz apresentou os melhores resultados com ausÃncia de defeitos, fraÃÃes de ferrita satisfatÃrias, menores fraÃÃes das inclusÃes e maiores valores de CPT.

Page generated in 0.0571 seconds