Efeitos dos filtros trocadores de calor e umidade sobre a mecânica respiratória / Effects of the heat and moiusture exchangers filters on respiratory mechanics

Gazola, Nayala Lirio Gomes 08 September 2008 (has links)
Made available in DSpace on 2016-12-06T17:07:18Z (GMT). No. of bitstreams: 1 Nayala.pdf: 583495 bytes, checksum: 3ae0b4b9f1adb9bc0b811436630f6b50 (MD5) Previous issue date: 2008-09-08 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Filters HME are devices that combine properties of humidification properties with retention through bacterial membranes, thus protecting mechanically ventilated patients. The objective was to examine, in an experimental model, the effects of different brands of filters HME, at different times of use, on the breathing of patients with mechanical ventilatory support artificial. This research characterized as being of an experimental nature. The sample was composed of thirty HMEs filters of three different brands that were used over 48 hours for patients admitted to the Intensive Care Unit - ICU at University Hospital, Federal University of Santa Catarina HU / UFSC. The instruments for data collection were: filters HMEs, analyzer flow and pressure, mechanical ventilator and simulated lung. The variables studied consisted of compliance and resistance to the airflow and these were analyzed at times 0, 24 and 48 hours for each brand of filter HME. The result is that both returned for compliance as the resistance to the flow of air there was no statistically significant difference between the brands in time for use 24 hours (p = 0489) and 48 hours (p = 0374), and that only in 0 hours of use time there was a statistically significant difference (p = 0027) between the brands studied. The results also showed that within the same brand there was no statistically significant difference in compliance and resistance to the airflow over time of use. It was the use of filters HMEs not interfere in compliance and resistance to the airflow of mechanically ventilated patients. / Os filtros HME são dispositivos que combinam propriedades de umidificação com propriedades de retenção bacterianas através de membranas que, desta forma, protegem pacientes mecanicamente ventilados. Objetivou-se analisar, em um modelo experimental, os efeitos de diferentes marcas de filtros HME, em diferentes tempos de uso, sobre a mecânica respiratória de pacientes com suporte ventilatório artificial. Esta pesquisa caracterizou-se como sendo de natureza experimental. A amostra foi composta de 30 filtros HMEs de três diferentes marcas que foram utilizados ao longo de 48 horas por pacientes internados na Unidade de Terapia Intensiva - UTI do Hospital Universitário da Universidade Federal de Santa Catarina HU/UFSC. Os instrumentos para a coleta de dados foram: filtros HMEs, analisador de fluxo e pressão, ventilador mecânico e simulador de pulmão. As variáveis estudadas consistiram na complacência e na resistência ao fluxo de ar e estas foram analisadas nos momentos 0, 24 e 48 horas para cada marca de filtro HME. Como resultado obteve-se que tanto para a complacência quanto para a resistência ao fluxo de ar não houve diferença estatisticamente significativa entre as marcas no tempo de uso 24 horas (p= 0,489) e 48 horas (p=0,374), sendo que apenas no momento 0 hora de utilização houve uma diferença estatisticamente significativa (p=0,027) entre as marcas estudadas. Os resultados também demonstraram que dentro da mesma marca não observou-se diferença estatisticamente significativa na complacência e na resistência ao fluxo de ar com o tempo de uso. Concluiu-se a utilização dos filtros HMEs não interferem na complacência e na resistência ao fluxo de ar de pacientes mecanicamente ventilados.

Page generated in 0.1122 seconds