• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Development of a 3D time reversal cavity for pulsed cavitational ultrasound : application to non-invasive cardiac therapy. / Développement d'une cavité à retournement temporal 3D pour la creation de pulse ultrasonores très intenses : application à la thérapie cardiaque non-invasive

Robin, Justine 01 December 2017 (has links)
L'objectif de cette thèse était d'explorer de nouvelles applications cardiaques pour l'histotripsie et de développer les outils permettant leur mise en place non-invasive. La thérapie ultrasonore cardiaque est en effet encore assez peu développée aujourd’hui, à cause de la difficulté à traiter un organe en mouvement permanent, et très bien protégé derrière la cage thoracique.Nous avons d'abord montré in vivo, sur un modèle ovin, que l’on pouvait sectionner les cordages mitraux de manière non-invasive ainsi que traiter la sténose aortique calcifiée. Engendrer de la cavitation sur les feuillets valvulaires permet effectivement d’agir à distance sur les calcifications, et de globalement assouplir la valve.Simultanément, nous avons développé un dispositif pour la thérapie cardiaque non invasive, fondé sur le concept de cavité à retournement temporel. Ce dispositif permet l'émission d'impulsions ultrasonores de haute intensité dans un très grand volume d’intérêt. L’on peut ainsi déplacer le point de thérapie en 3 dimensions de manière entièrement électronique, et sans déplacer mécaniquement l’appareil. Après optimisation, ce dispositif a permis de créer des lésions mécaniques bien contrôlées dans une région d'intérêt de 2 000 cm3.Pour faire face au défi que représente la cage thoracique, nous avons développé une méthode de focalisation adaptative et l'avons mise en œuvre dans un prototype 2D du dispositif. Avec cette méthode, nous pouvons non seulement construire un front d'onde ultrasonore adaptatif qui se propage de manière préférentielle à travers les espaces intercostaux, mais grâce aux propriétés des cavités à retournement temporel, nous pouvons également augmenter la pression focale obtenue sur la cible de thérapie.Enfin, pour approfondir ce travail sur la focalisation adaptative, et nous avons considéré le cas de l'imagerie transcrânienne. Pour cette application, nous avons choisi d’utiliser la focalisation par retournement temporel dans le bruit de speckle, pour corriger les aberrations induites par le crâne. En simulations numériques, nous avons pu calculer les modulations de phase et d'amplitude induites par les os et améliorer le contraste et la résolution d'une image B-mode. / The objective of this thesis was to explore new applications for cardiac histotripsy, and to develop the tools making it possible non-invasively. Cardiac ultrasound therapy indeed still remains limited due to the tremendous challenge of treating a constantly and rapidly moving organ, well protected behind the ribcage.We first showed in vivo, on a large animal model, that histotripsy could be used non-invasively to cut mitral chordae, and to treat calcified aortic stenosis in a beating heart. Cavitation on the valve leaflets can indeed locally and remotely act on the calcifications, and globally soften the valve. Simultaneously, we developed a therapeutic device allowing completely non-invasive cardiac shock-wave therapy based on the time reversal cavity concept. In particular, this device allows the emission of high intensity ultrasound pulses, and provides 3D electronical steering of the therapy focal spot in a large volume. After a thorough optimisation process, this device was capable of creating well controlled mechanical lesions over a 2 000 cm3 region of interest. To tackle the challenge of ultrasound propagation through the rib cage, we developed an adaptive focusing method (DORT method through a time reversal cavity), and implemented it in a 2D prototype of the device. With this method, we not only could build an adaptive ultrasonic wavefront propagating preferentially through the intercostal spaces, but due to time reversal cavities properties, we could also increase the peak pressure obtained on target.Finally, we pushed our work on adaptive focusing further, and considered the case of transcranial imaging. For this application, we chose to use the time reversal of speckle noise technique, to correct the aberrations induced by the skull. In numerical simulations, we were able to derive the phase and amplitude modulations induced by the bones, and could improve the contrast and resolution of a B-mode image.
2

Focalisation d'ultrasons par retournement temporel et filtre inverse, application à l'échographie transcrânienne

Vignon, Francois 30 September 2005 (has links) (PDF)
Les échographies de cerveau chez l'adulte sont aujourd'hui de pauvre qualité à cause de l'os du crâne qui absorbe et défocalise fortement les ultrasons. Il est possible de focaliser des ultrasons à travers le crâne en émettant un front d'onde déformé qui, après passage de l'os du crâne, reforme un front d'ondes focalisant. Le calcul des déformations à appliquer au front d'ondes émis se fait par retournement temporel ou par filtre inverse, deux techniques basées sur la mesure et le traitement de fonctions de Green entre les transducteurs de la barrette d'imagerie et les points focaux désirés. Il est nécessaire de disposer des transducteurs ultrasonores au cœur du milieu à imager pour mesurer ces fonctions de Green, ce qui interdit l'application directe de ces techniques pour l'imagerie médicale. Nous montrons ici comment modifier ces techniques de focalisation pour les rendre non intrusives : filtre inverse et retournement temporel non intrusifs améliorent la qualité d'échographies transcrâniennes. La problématique de la thèse : « comment focaliser de manière adaptative à travers un milieu aberrateur sans placer de transducteurs ultrasonores dans le milieu à imager ? », nous a conduit à nous demander « comment avoir accès aux déformations de l'onde transmise à partir de l'analyse de signaux réfléchis par l'aberrateur (mesurables de manière non intrusive)? » Nous avons mis en évidence le lien qui existe entre filtre inverse et cavité à retournement temporel, via les équations de Stokes. D'autre part, nous avons posé les bases d'une manière de rendre le filtre inverse minimalement intrusif, ouvrant des perspectives intéressantes dans le domaine des télécommunications.

Page generated in 0.2838 seconds