• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Uso de sensor efeito Hall para medição da vazão de fluidos no processo de produção de palatabilizantes a base de proteína animal em escala piloto / Using Hall-effect sensor for measuring the fluid flow in the production process palatability animal protein based on a pilot scale

Horigoshi, Francis Massashi 06 September 2016 (has links)
Os medidores de vazão contribuem de forma significante para a otimização industrial onde o deslocamento contínuo de massa é parte integrante do sistema produtivo, sendo, portanto, cruciais para a indústria permitindo assim padronizar produtos e automatizar ações reduzindo a força de trabalho humana e minimizando erros. Este é o caso da produção de palatabilizantes, substâncias produzidas a partir da hidrólise enzimática da proteína animal para conferir aroma e sabor aos alimentos, onde existe um deslocamento continuo de massa com dosagem de fluidos acionadas em várias etapas do processo. Podem-se destacar duas etapas principais: a etapa onde ocorre a dosagem de soluções alcalinas para a hidrólise enzimática e a etapa onde ocorre a acidificação para garantir a segurança microbiológica do produto. No trabalho em questão foi desenvolvido e analisado um medidor de vazão de turbina por sensoriamento via efeito Hall, para determinar a vazão volumétrica de fludos no processo produtivo de palatabilizantes. O sistema utilizado na avaliação do medidor de vazão foi desenvolvido em escala piloto. A calibração do medidor permitiu-se calcular o fator K (coeficiente do medidor) tanto para água, onde o coeficiente foi de 5,5, quanto para palatabilizantes, onde o coeficiente calculado foi de 7. A partir dos dados obtidos pelo medidor de vazão pode-se observar um alto nível de correlação dos dados. O medidor de vazão apresentou-se eficaz para os fluidos testados (água e palatabilizante); e, com uma precisão de ± 2%, mostra-se uma alternativa viável para o processo de produção de palatabilizantes. / Flowmeters contribute significantly to the industrial optimization where mass continuous displacement is an integral part of the production system, is therefore crucial for the industry allowing standardize products and automate actions reducing human labor and minimizing errors. This is the case of the production of flavors, substances produced from the enzymatic hydrolysis of animal protein to impart flavor and aroma to food, where there is a continuous mass displacement with fluids dosage triggered in several process steps. They can point out two main steps: a step where dosing occurs alkaline solutions for enzymatic hydrolysis and acidification stage which takes place to ensure the microbiological safety of the product. At work in question was developed and analyzed a turbine flowmeter for sensing via Hall effect to determine the volumetric flow fludos in the production of palatability process. The system used to assess the flow meter was developed on a pilot scale. The meter calibration allowed to calculate the K factor (the ratio meter) for both water where the ratio was 5.5, and for palatability, where the coefficient was calculated 7. From the data obtained by the flowmeter one can observe a high degree of correlation of the data. The flowmeter is made effective for the tested fluids (water and palatability); and with an accuracy of ± 2%, there is shown a viable alternative for the production of flavors process.
2

Uso de sensor efeito Hall para medição da vazão de fluidos no processo de produção de palatabilizantes a base de proteína animal em escala piloto / Using Hall-effect sensor for measuring the fluid flow in the production process palatability animal protein based on a pilot scale

Francis Massashi Horigoshi 06 September 2016 (has links)
Os medidores de vazão contribuem de forma significante para a otimização industrial onde o deslocamento contínuo de massa é parte integrante do sistema produtivo, sendo, portanto, cruciais para a indústria permitindo assim padronizar produtos e automatizar ações reduzindo a força de trabalho humana e minimizando erros. Este é o caso da produção de palatabilizantes, substâncias produzidas a partir da hidrólise enzimática da proteína animal para conferir aroma e sabor aos alimentos, onde existe um deslocamento continuo de massa com dosagem de fluidos acionadas em várias etapas do processo. Podem-se destacar duas etapas principais: a etapa onde ocorre a dosagem de soluções alcalinas para a hidrólise enzimática e a etapa onde ocorre a acidificação para garantir a segurança microbiológica do produto. No trabalho em questão foi desenvolvido e analisado um medidor de vazão de turbina por sensoriamento via efeito Hall, para determinar a vazão volumétrica de fludos no processo produtivo de palatabilizantes. O sistema utilizado na avaliação do medidor de vazão foi desenvolvido em escala piloto. A calibração do medidor permitiu-se calcular o fator K (coeficiente do medidor) tanto para água, onde o coeficiente foi de 5,5, quanto para palatabilizantes, onde o coeficiente calculado foi de 7. A partir dos dados obtidos pelo medidor de vazão pode-se observar um alto nível de correlação dos dados. O medidor de vazão apresentou-se eficaz para os fluidos testados (água e palatabilizante); e, com uma precisão de ± 2%, mostra-se uma alternativa viável para o processo de produção de palatabilizantes. / Flowmeters contribute significantly to the industrial optimization where mass continuous displacement is an integral part of the production system, is therefore crucial for the industry allowing standardize products and automate actions reducing human labor and minimizing errors. This is the case of the production of flavors, substances produced from the enzymatic hydrolysis of animal protein to impart flavor and aroma to food, where there is a continuous mass displacement with fluids dosage triggered in several process steps. They can point out two main steps: a step where dosing occurs alkaline solutions for enzymatic hydrolysis and acidification stage which takes place to ensure the microbiological safety of the product. At work in question was developed and analyzed a turbine flowmeter for sensing via Hall effect to determine the volumetric flow fludos in the production of palatability process. The system used to assess the flow meter was developed on a pilot scale. The meter calibration allowed to calculate the K factor (the ratio meter) for both water where the ratio was 5.5, and for palatability, where the coefficient was calculated 7. From the data obtained by the flowmeter one can observe a high degree of correlation of the data. The flowmeter is made effective for the tested fluids (water and palatability); and with an accuracy of ± 2%, there is shown a viable alternative for the production of flavors process.
3

“PRECISÃO E ACURÁCIA PLANIMÉTRICA DO RECEPTOR GPS GSTAR GS-87: APLICABILIDADE EM TECNOLOGIA DE INFORMAÇÃO EMBARCADA PARA SISTEMAS AGRÍCOLAS”

Cerutti, Idomar Augusto 23 July 2012 (has links)
Made available in DSpace on 2017-07-21T14:19:34Z (GMT). No. of bitstreams: 1 Idomar Cerutti.pdf: 3056980 bytes, checksum: 1f558a41e8107db9e91550dc01470a55 (MD5) Previous issue date: 2012-07-23 / The use of geo-referenced information in precision farming has increased greatly in the last decade. Furthermore, the decrease in the cost of GPS reception equipment has made possible their use by people who did not previously have access to this technology. This research aims to evaluate the precision and accuracy of the GPS receptor model Gstar GS-87, to understand its applicability for information systems embedded in agricultural systems. This research is part of the Agrobot project, which is being developed at the Laboratory of Automation and Control, State University of Ponta Grossa. An embedded computer Friendly ARM, model Mini6410 was used, with operating system Linux version 2.6.38. Static absolute surveys were conducted at three geodesic marks: Castro (96005), UEPG Campus (91643) and Pilar UFPR 1000.Several kinematic surveys were also carried out to compare the GPS coordinates collected by GPS receptor Gstar GS-87, with data collected by Geodetic GPS receptor Leica GX-1230. The static surveys from this research show that the GS-87 demonstrated a dimensional accuracy of +/- 8.19 m, with standard deviation of 11.43 m, and bi-dimensional accuracy +/- 13.78 m with a standard deviation of 14.26 m. In relation to kinematic surveying the receiver had an accuracy of +/- 3.70 m with a standard deviation of 1.88 m. A time difference of 15 sec between the data collected for both receptors was observed. Also was observed that the GPS receptor Gstar GS-87 recorded changes of coordinates properly when it was on the move with a speed equal to or greater than 9 km/h. It can be argued that the GPS receiver Gstar GS-87 can be used in an embedded information system, where the need for precision and accuracy are consistent with the data presented in this study. / O uso de informações georreferenciadas na agricultura de precisão tem crescido muito na última década. Além disso, o decréscimo do custo dos equipamentos de recepção GPS tem tornado possível o seu uso por produtores agrícolas que estavam distantes de tal tecnologia. Esta pesquisa objetiva avaliar a precisão e acurácia de receptor GPS modelo Gstar GS-87, para compreender sua aplicabilidade em sistemas de informação embarcado com sistema agrícolas. A pesquisa é parte do projeto Agrobot, que está sendo desenvolvido no Laboratório de Automação e Controle da Universidade Estadual de Ponta Grossa. Foi utilizado computador embarcado Friendly ARM modelo Mini6410, com sistema operacional Linux versão 2.6.38. Foram realizados três levantamentos absolutos estáticos nos marcos geodésicos Castro (96005), UEPG Campus (91643) e UFPR Pilar 1000, bem como diversos levantamentos absolutos cinemáticos para comparar as coordenadas coletadas pelo receptor GPS Gstar GS-87, com os dados coletados pelo receptor GPS geodésico Leica GX-1230. Como resultado da pesquisa, em levantamentos absolutos estáticos, pode-se afirmar que o receptor apresenta acurácia idimensional de +/-8,19 m, com desvio padrão de 11,43 m e precisão bidimensional +/- 13,78 m com desvio padrão de 14,26 m. Em levantamentos absolutos cinemáticos o receptor tem uma precisão de +/- 3,70 m, com desvio padrão de 1,88 m. Também se observou uma diferença de tempo de 15 seg entre os dados coletados por ambos os receptores. Ainda foi observado que o receptor GPS Gstar GS-87 registrava adequadamente alterações de coordenadas quando estava em deslocamento com velocidade igual ou superior a 9 km/h. É possível afirmar que o receptor GPS Gstar GS-87 pode ser utilizado em sistemas de informação embarcado, onde a necessidade de precisão e acurácia sejam compatíveis com os dados apresentados nesta pesquisa.

Page generated in 0.0685 seconds