• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo de radiomarcação com gálio-68 do inibidor de PSMA baseado em ureia - avaliação comparativa de método automatizado e não automatizado / Study radiolabeling of urea-based PSMA inibitor with 68-gallium comparative evaluation of authomated and not authomated methods

Alcarde, Lais Fernanda 05 April 2016 (has links)
Os métodos para o diagnóstico clínico de câncer de próstata incluem o toque retal e a dosagem do antígeno prostático específico (PSA). Entretanto, o nível de PSA encontra-se elevado em cerca de 20 a 30% dos casos relacionados a patologias benignas, o que resulta em falsos positivos e leva os pacientes a realização de biópsias desnecessárias. O antígeno de membrana prostático específico (PSMA), ao contrário, é sobre expresso no câncer de próstata e encontrado em baixos níveis em órgãos saudáveis. Em razão disso, estimulou-se o desenvolvimento de pequenas moléculas inibidoras do receptor de PSMA, que carreguem agentes de imagem ao tumor e que não sejam prejudicadas pela microvasculatura deste. Estudos recentes sugerem que o quelante HBED-CC contribui intrinsicamente para a ligação do peptídeo inibidor de PSMA baseado em ureia (Glu-ureia-Lys) ao grupo farmacofórico. Este trabalho descreve os estudos de otimização das condições de radiomarcação do PSMA-HBED-CC com 68Ga, utilizando sistema automatizado (módulo de síntese) e método não automatizado, buscando estabelecer uma condição adequada de preparação deste novo radiofármaco, com ênfase no rendimento da marcação e na pureza radioquímica do produto. Também objetivou avaliar a estabilidade do peptídeo radiomarcado em condições de transporte e estudar a distribuição biológica do radiofármaco em camundongos sadios. O estudo dos parâmetros de radiomarcação possibilitou definir um método não automatizado que resultou em alta pureza radioquímica (> 95%), sem a necessidade de purificação do radiomarcado. Já o método de marcação automatizado foi adaptado para utilizar módulo de síntese e software já disponíveis no IPEN, e também resultou em rendimento de síntese elevado (≥ 90%) e superior aos descritos em literatura, com a vantagem associada de maior controle do processo produtivo em atendimento aos requisitos de Boas Práticas de Fabricação. O estudo dos parâmetros de radiomarcação permitiu a obtenção do PSMA-HBED-CC-68Ga com atividade específica superior à utilizada em estudos clínicos publicados (≥ 140,0 GBq/μmol), com estabilidade suficientemente longa, que permitirá o transporte às clínicas para aplicação na obtenção de imagens diagnósticas. Os perfis de biodistribuição e farmacocinético do peptídeo radiomarcado foram compatíveis com os encontrados na literatura. Conclui-se que o PSMA-HBED-CC-68Ga, é uma importante ferramenta de diagnóstico do câncer de próstata por imagem PET, pode ser produzido tanto por método automatizado ou não automatizado, com alta pureza radioquímica, alto rendimento de síntese e estabilidade do radiofármaco. / The methods for clinical diagnosis of prostate cancer include rectal examination and the dosage of the prostatic specific antigen (PSA). However, the PSA level is elevated in about 20 to 30% of cases related to benign pathologies, resulting in false positives and leading patients to unnecessary biopsies. The prostate specific membrane antigen (PSMA), in contrast, is over expressed in prostate cancer and founded at low levels in healthy organs. As a result, it stimulated the development of small molecule inhibitors of PSMA, which carry imaging agents to the tumor and are not affected by their microvasculature. Recent studies suggest that the HBED-CC chelator intrinsically contributes to the binding of the PSMA inhibitor peptide based on urea (Glu-urea-Lys) to the pharmacophore group. This work describes the optimization of radiolabeling conditions of PSMA-HBED-CC with 68Ga, using automated system (synthesis module) and no automated method, seeking to establish an appropriate condition to prepare this new radiopharmaceutical, with emphasis on the labeling yield and radiochemical purity of the product. It also aimed to evaluate the stability of the radiolabeled peptide in transport conditions and study the biological distribution of the radiopharmaceutical in healthy mice. The study of radiolabeling parameters enabled to define a non-automated method which resulted in high radiochemical purity (> 95 %) without the need for purification of the labeled peptide. The automated method has been adapted, using a module of synthesis and software already available at IPEN, and also resulted in high synthetic yield (≥ 90%) specially when compared with those described in the literature, with the associated benefit of greater control of the production process in compliance with Good Manufacturing Practices. The study of radiolabeling parameters afforded the PSMA-HBED-CC-68Ga with higher specific activity than observed in published clinical studies (≥ 140,0 GBq/μmol), with a sufficiently long stability, which will enable transport to clinics for use in diagnostic imaging. Biodistribution and pharmacokinetic profiles of the radiolabeled peptide were consistent with those founded in the literature. We concluded that PSMA-HBED-CC-68Ga, important diagnostic tool for prostate cancer imaging with PET, can be produced by either automated or not automated method with high radiochemical purity, high synthetic yield and stability of the radiopharmaceutical.
2

Estudo da marcação com Indio-111 e Gálio-68 de derivados da bombesina e avaliação das propriedades biológicas para aplicação em SPECT e PET / Study of labelling of bombesin derivatives with 111-indium and 68-galium and evaluation of biological properties for application in SPECT and PET

Oliveira, Ricardo de Souza 10 December 2014 (has links)
Receptores para o peptídeo liberador de gastrina (GRPr) são super expressos em vários tipos de células cancerígenas, incluindo câncer de mama e próstata. A Bombesina é um análogo do peptídeo GRP de mamíferos que se liga com alta especificidade e afinidade aos receptores do peptídeo liberador de gastrina (GRPr). Significantes pesquisas têm sido realizadas para desenvolver e radiomarcar um análogo da bombesina para diagnóstico de tumores de próstata e mama, utilizando-se técnicas de SPECT e PET, com radionuclídeos como 111In e 68Ga. O objetivo deste trabalho foi estudar a marcação com 111In de uma série inédita de peptídeos derivados de bombesina e determinar o potencial de aplicação no diagnóstico de tumores de próstata em modelos animais. Vários estudos foram realizados para padronizar o procedimento de marcação, variando-se temperatura, tempo de marcação, massa do peptídeo e atividade do radionuclídeo. Os resultados demonstraram que os análogos da bombesina estudados podem ser marcados com índio-111 com alto rendimento de marcação e alta atividade específica. Os estudos de biodistribuição em animais normais demonstraram que o derivado de BBN com espaçador aminoacídico Gly5 apresentou captação pancreática e intestinal expressiva, sugerindo ser o melhor derivado. Dois derivados DOTA- conjugados, com espaçador Gly5 foram radiomarcados com gálio-68 e investigados em modelo animal com tumor de próstata humano, indicando o potencial para aplicação do peptídeo radiomarcado no diagnóstico por PET. / Gastrin releasing peptide receptors (GRPRs) are over expressed in various types of cancer cells including prostate and breast cancer. Bombesin is an analogue of the mammalian GRP that binds with high specificity and affinity to GRPRs. Significant research efforts have been devoted to the design and radiolabel bombesin peptides for the diagnostic of prostatic and breast cancer using SPECT e PET, with radionuclides like 111In e 68Ga. The objective of this work was to study the labeling with 111In of a new bombesin series and evaluate the potential for diagnostic application using animal model. Several studies were evaluated to optimize the labelling conditions of BBN derivatives with 111In using different temperature, time, mass of peptide and radionuclide activity. High radiochemical purity and high specific activity were obtained for all the peptides labeled with 111-indium. Biodistribution studies in normal mices showed that the BBN derivative with Gly5 as aminoacidic spacer presented high uptake on pancreas and intestines that suggests that is the best peptide. Two DOTA-derivatives with Gly5 as spacer were radiolabelled with 68-gallium and evaluated in tumor model animals of human prostatic cancer and showed high potential for clinical application in diagnostic procedures with PET.
3

Estudo da marcação com Indio-111 e Gálio-68 de derivados da bombesina e avaliação das propriedades biológicas para aplicação em SPECT e PET / Study of labelling of bombesin derivatives with 111-indium and 68-galium and evaluation of biological properties for application in SPECT and PET

Ricardo de Souza Oliveira 10 December 2014 (has links)
Receptores para o peptídeo liberador de gastrina (GRPr) são super expressos em vários tipos de células cancerígenas, incluindo câncer de mama e próstata. A Bombesina é um análogo do peptídeo GRP de mamíferos que se liga com alta especificidade e afinidade aos receptores do peptídeo liberador de gastrina (GRPr). Significantes pesquisas têm sido realizadas para desenvolver e radiomarcar um análogo da bombesina para diagnóstico de tumores de próstata e mama, utilizando-se técnicas de SPECT e PET, com radionuclídeos como 111In e 68Ga. O objetivo deste trabalho foi estudar a marcação com 111In de uma série inédita de peptídeos derivados de bombesina e determinar o potencial de aplicação no diagnóstico de tumores de próstata em modelos animais. Vários estudos foram realizados para padronizar o procedimento de marcação, variando-se temperatura, tempo de marcação, massa do peptídeo e atividade do radionuclídeo. Os resultados demonstraram que os análogos da bombesina estudados podem ser marcados com índio-111 com alto rendimento de marcação e alta atividade específica. Os estudos de biodistribuição em animais normais demonstraram que o derivado de BBN com espaçador aminoacídico Gly5 apresentou captação pancreática e intestinal expressiva, sugerindo ser o melhor derivado. Dois derivados DOTA- conjugados, com espaçador Gly5 foram radiomarcados com gálio-68 e investigados em modelo animal com tumor de próstata humano, indicando o potencial para aplicação do peptídeo radiomarcado no diagnóstico por PET. / Gastrin releasing peptide receptors (GRPRs) are over expressed in various types of cancer cells including prostate and breast cancer. Bombesin is an analogue of the mammalian GRP that binds with high specificity and affinity to GRPRs. Significant research efforts have been devoted to the design and radiolabel bombesin peptides for the diagnostic of prostatic and breast cancer using SPECT e PET, with radionuclides like 111In e 68Ga. The objective of this work was to study the labeling with 111In of a new bombesin series and evaluate the potential for diagnostic application using animal model. Several studies were evaluated to optimize the labelling conditions of BBN derivatives with 111In using different temperature, time, mass of peptide and radionuclide activity. High radiochemical purity and high specific activity were obtained for all the peptides labeled with 111-indium. Biodistribution studies in normal mices showed that the BBN derivative with Gly5 as aminoacidic spacer presented high uptake on pancreas and intestines that suggests that is the best peptide. Two DOTA-derivatives with Gly5 as spacer were radiolabelled with 68-gallium and evaluated in tumor model animals of human prostatic cancer and showed high potential for clinical application in diagnostic procedures with PET.
4

Estudo de radiomarcação com gálio-68 do inibidor de PSMA baseado em ureia - avaliação comparativa de método automatizado e não automatizado / Study radiolabeling of urea-based PSMA inibitor with 68-gallium comparative evaluation of authomated and not authomated methods

Lais Fernanda Alcarde 05 April 2016 (has links)
Os métodos para o diagnóstico clínico de câncer de próstata incluem o toque retal e a dosagem do antígeno prostático específico (PSA). Entretanto, o nível de PSA encontra-se elevado em cerca de 20 a 30% dos casos relacionados a patologias benignas, o que resulta em falsos positivos e leva os pacientes a realização de biópsias desnecessárias. O antígeno de membrana prostático específico (PSMA), ao contrário, é sobre expresso no câncer de próstata e encontrado em baixos níveis em órgãos saudáveis. Em razão disso, estimulou-se o desenvolvimento de pequenas moléculas inibidoras do receptor de PSMA, que carreguem agentes de imagem ao tumor e que não sejam prejudicadas pela microvasculatura deste. Estudos recentes sugerem que o quelante HBED-CC contribui intrinsicamente para a ligação do peptídeo inibidor de PSMA baseado em ureia (Glu-ureia-Lys) ao grupo farmacofórico. Este trabalho descreve os estudos de otimização das condições de radiomarcação do PSMA-HBED-CC com 68Ga, utilizando sistema automatizado (módulo de síntese) e método não automatizado, buscando estabelecer uma condição adequada de preparação deste novo radiofármaco, com ênfase no rendimento da marcação e na pureza radioquímica do produto. Também objetivou avaliar a estabilidade do peptídeo radiomarcado em condições de transporte e estudar a distribuição biológica do radiofármaco em camundongos sadios. O estudo dos parâmetros de radiomarcação possibilitou definir um método não automatizado que resultou em alta pureza radioquímica (> 95%), sem a necessidade de purificação do radiomarcado. Já o método de marcação automatizado foi adaptado para utilizar módulo de síntese e software já disponíveis no IPEN, e também resultou em rendimento de síntese elevado (≥ 90%) e superior aos descritos em literatura, com a vantagem associada de maior controle do processo produtivo em atendimento aos requisitos de Boas Práticas de Fabricação. O estudo dos parâmetros de radiomarcação permitiu a obtenção do PSMA-HBED-CC-68Ga com atividade específica superior à utilizada em estudos clínicos publicados (≥ 140,0 GBq/μmol), com estabilidade suficientemente longa, que permitirá o transporte às clínicas para aplicação na obtenção de imagens diagnósticas. Os perfis de biodistribuição e farmacocinético do peptídeo radiomarcado foram compatíveis com os encontrados na literatura. Conclui-se que o PSMA-HBED-CC-68Ga, é uma importante ferramenta de diagnóstico do câncer de próstata por imagem PET, pode ser produzido tanto por método automatizado ou não automatizado, com alta pureza radioquímica, alto rendimento de síntese e estabilidade do radiofármaco. / The methods for clinical diagnosis of prostate cancer include rectal examination and the dosage of the prostatic specific antigen (PSA). However, the PSA level is elevated in about 20 to 30% of cases related to benign pathologies, resulting in false positives and leading patients to unnecessary biopsies. The prostate specific membrane antigen (PSMA), in contrast, is over expressed in prostate cancer and founded at low levels in healthy organs. As a result, it stimulated the development of small molecule inhibitors of PSMA, which carry imaging agents to the tumor and are not affected by their microvasculature. Recent studies suggest that the HBED-CC chelator intrinsically contributes to the binding of the PSMA inhibitor peptide based on urea (Glu-urea-Lys) to the pharmacophore group. This work describes the optimization of radiolabeling conditions of PSMA-HBED-CC with 68Ga, using automated system (synthesis module) and no automated method, seeking to establish an appropriate condition to prepare this new radiopharmaceutical, with emphasis on the labeling yield and radiochemical purity of the product. It also aimed to evaluate the stability of the radiolabeled peptide in transport conditions and study the biological distribution of the radiopharmaceutical in healthy mice. The study of radiolabeling parameters enabled to define a non-automated method which resulted in high radiochemical purity (> 95 %) without the need for purification of the labeled peptide. The automated method has been adapted, using a module of synthesis and software already available at IPEN, and also resulted in high synthetic yield (≥ 90%) specially when compared with those described in the literature, with the associated benefit of greater control of the production process in compliance with Good Manufacturing Practices. The study of radiolabeling parameters afforded the PSMA-HBED-CC-68Ga with higher specific activity than observed in published clinical studies (≥ 140,0 GBq/μmol), with a sufficiently long stability, which will enable transport to clinics for use in diagnostic imaging. Biodistribution and pharmacokinetic profiles of the radiolabeled peptide were consistent with those founded in the literature. We concluded that PSMA-HBED-CC-68Ga, important diagnostic tool for prostate cancer imaging with PET, can be produced by either automated or not automated method with high radiochemical purity, high synthetic yield and stability of the radiopharmaceutical.

Page generated in 0.0235 seconds