• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 285
  • 71
  • 1
  • Tagged with
  • 443
  • 443
  • 194
  • 174
  • 26
  • 17
  • 11
  • 11
  • 10
  • 8
  • 8
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Système de localisation relative ultrasonique pour équipe de véhicules sans-pilote : Principes et expérimentations

Morris, Alexandre 03 1900 (has links) (PDF)
No description available.
42

Gait Analysis, modelling, and comparison from unconstrained walks and viewpoints. View-rectification of Body-part Trajectories from Monocular Video Sequences

Jean, Frédéric 04 1900 (has links) (PDF)
L'analyse, la modélisation et la comparaison de la démarche de personnes à l'aide d'algorithmes de vision artificielle a récemment suscité beaucoup d'intérêt dans les domaines d'applications médicales et de surveillance. Il y a en effet plusieurs avantages à utiliser des algorithmes de vision artificielle pour faire l'analyse, la modélisation et la comparaison de la démarche de personnes. Par exemple, la démarche d'une personne peut être analysée et modélisée de loin en observant la personne à l'aide d'une caméra, ce qui ne requiert pas le placement de marqueurs ou de senseurs sur la personne. De plus, la coopération des personnes observées n'est pas requise, ce qui permet d'utiliser la démarche des personnes comme un facteur d'identification biométrique dans les systèmes de surveillance automatique. Les méthodes d'analyse et de modélisation de la démarche existantes comportent toutefois plusieurs limitations. Plusieurs de ces méthodes nécessitent une vue de profil des personnes puisque ce point de vue est optimal pour l'analyse et la modélisation de la démarche. La plupart de ces méthodes supposent également une distance assez grande entre les personnes et la caméra afin de limiter les effets néfastes que la projection de perspective a sur l'analyse et la modélisation de la démarche. Par ailleurs, ces méthodes ne gèrent pas les changements de direction et de vitesse dans les marches. Cela limite grandement les marches pouvant être analysées et modélisées dans les applications médicales et les applications de surveillance. L'approche proposée dans cette thèse permet d'effectuer l'analyse, la modélisation et la comparaison de la démarche de personnes à partir de marches et de points de vue non contraints. L'approche proposée est principalement constituée d'une méthode de rectification du point de vue qui permet de générer une vue fronto-parallèle (vue de profil) de la trajectoire imagée des membres d'une personne. Cette méthode de rectification de la vue est basée sur un modèle de marche novateur qui utilise la géométrie projective pour faire les liens spatio-temporels entre la position des membres dans la scène et leur contrepartie dans les images provenant d'une caméra. La tête et les pieds sont les seuls membres nécessaires à l'approche proposée dans cette thèse. La position et le suivi de ces membres sont automatiquement effectués par un algorithme de suivi des membres développé dans le cadre de cette thèse. L'analyse de la démarche est effectuée par une nouvelle méthode qui extrait des caractéristiques de la démarche à partir de la trajectoire rectifiée des membres. Un nouveau modèle de la démarche basé sur la trajectoire rectifiée des membres est proposé afin de permettre la modélisation et la comparaison de la démarche en utilisant les caractéristiques dynamiques de la démarche. L'approche proposée dans cette thèse est premièrement validée à l'aide de marches synthétiques comprenant plusieurs points de vue différents ainsi que des changements de direction. Les résultats de cette étape de validation montrent que la méthode de rectification de la vue fonctionne correctement, et qu'il est possible d'extraire des caractéristiques de la démarche valides à partir de la trajectoire rectifiée des membres. Par la suite, l'analyse, la modélisation et la comparaison de la démarche de personnes sont effectuées sur des marches réelles qui ont été acquises dans le cadre de cette thèse. Ces marches sont particulièrement difficiles à analyser et à modéliser puisqu'elles ont été effectuées près de la caméra et qu'elles comportent des changements de direction et de vitesse. Les résultats d'analyse de la démarche confirment que les caractéristiques de la démarche obtenues à l'aide de la méthode proposée sont réalistes et sont en accord avec les résultats présentés dans les études cliniques de la démarche. Les résultats de modélisation et de comparaison de la démarche démontrent qu'il est possible d'utiliser la méthode proposée pour reconnaître des personnes par leur démarche dans le contexte des applications de surveillance. Les taux de reconnaissance obtenus sont bons considérant la complexité des marches utilisées dans cette thèse. / Gait analysis, modelling and comparison using computer vision algorithms has recently attracted much attention for medical and surveillance applications. Analyzing and modelling a person's gait with computer vision algorithms has indeed some interesting advantages over more traditional biometrics. For instance, gait can be analyzed and modelled at a distance by observing the person with a camera, which means that no markers or sensors have to be worn by the person. Moreover, gait analysis and modelling using computer vision algorithms does not require the cooperation of the observed people, which thus allows for using gait as a biometric in surveillance applications. Current gait analysis and modelling approaches have however severe limitations. For instance, several approaches require a side view of the walks since this viewpoint is optimal for gait analysis and modelling. Most approaches also require the walks to be observed far enough from the camera in order to avoid perspective distortion effects that would badly affect the resulting gait analyses and models. Moreover, current approaches do not allow for changes in walk direction and in walking speed, which greatly constraints the walks that can be analyzed and modelled in medical and surveillance applications. The approach proposed in this thesis aims at performing gait analysis, modelling and comparison from unconstrained walks and viewpoints in medical and surveillance applications. The proposed approach mainly consists in a novel view-rectification method that generates a fronto-parallel viewpoint (side view) of the imaged trajectories of body parts. The view-rectification method is based on a novel walk model that uses projective geometry to provide the spatio-temporal links between the body-part positions in the scene and their corresponding positions in the images. The head and the feet are the only body parts that are relevant for the proposed approach. They are automatically localized and tracked in monocular video sequences using a novel body parts tracking algorithm. Gait analysis is performed by a novel method that extracts standard gait measurements from the view-rectified body-part trajectories. A novel gait model based on body-part trajectories is also proposed in order to perform gait modelling and comparison using the dynamics of the gait. The proposed approach is first validated using synthetic walks comprising different viewpoints and changes in the walk direction. The validation results shows that the proposed view-rectification method works well, that is, valid gait measurements can be extracted from the view-rectified body-part trajectories. Next, gait analysis, modelling, and comparison is performed on real walks acquired as part of this thesis. These walks are challenging since they were performed close to the camera and contain changes in walk direction and in walking speed. The results first show that the obtained gait measurements are realistic and correspond to the gait measurements found in references on clinical gait analysis. The gait comparison results then show that the proposed approach can be used to perform gait modelling and comparison in the context of surveillance applications by recognizing people by their gait. The computed recognition rates are quite good considering the challenging walks used in this thesis.
43

Nondestructive testing of metals and composite materials using ultrasound thermography : Comparison with pulse-echo ultrasonics

Peycheva, Kira 11 1900 (has links) (PDF)
No description available.
44

Modélisation interactive : amélioration du processus de reconstruction d'un modèle 3D par la compression temps réel

Deschênes, Jean-Daniel 05 1900 (has links) (PDF)
Inscrit au Tableau d'honneur de la Faculté des études supérieures
45

Comparaison expérimentale de la thermographie modulée et de la thermographie pulsée pour l'évaluation non destructive des matériaux employés en aérospatial

Ben Larbi, Wael 07 1900 (has links) (PDF)
No description available.
46

Mitigating Error Propagation of Decision Feedback Equalization in Broadband Communications

Wang, Rujiang 04 1900 (has links) (PDF)
No description available.
47

APIA : Architecture Propriété Interaction Acteur pour des mondes virtuels agiles

Bernier, François 05 1900 (has links) (PDF)
No description available.
48

Description incrémentale d'objets déformables dans des séquences vidéo

Drouin, Stéphane 05 1900 (has links) (PDF)
No description available.
49

Minimisation de la gigue d'échantillonnage d'un spectromètre à transformée de Fourier imageur à détecteur intégrateur en présence de perturbations mécaniques

Déry, Jean-Philippe 02 1900 (has links) (PDF)
No description available.
50

Rectifier Solutions for a Transverse Flux Permanent Magnet Machine

Taghizadeh Kakhki, Mehdi 05 1900 (has links) (PDF)
No description available.

Page generated in 0.0611 seconds