Spelling suggestions: "subject:"gallium arsenic (dass)"" "subject:"gallium arsenic (bass)""
1 |
Compact high-repetition-rate terahertz source based on difference frequency generation from an efficient 2-μm dual-wavelength KTP OPOMei, Jialin, Zhong, Kai, Wang, Maorong, Liu, Pengxiang, Xu, Degang, Wang, Yuye, Shi, Wei, Yao, Jianquan, Norwood, Robert A., Peyghambarian, Nasser 03 November 2016 (has links)
A compact optical terahertz (THz) source was demonstrated based on an efficient high-repetition-rate doubly resonant optical parametric oscillator (OPO) around 2 mu m with two type-II phase-matched KTP crystals in the walk-off compensated configuration. The KTP OPO was intracavity pumped by an acousto-optical (AO) Q-switched Nd:YVO4 laser and emitted two tunable wavelengths near degeneracy. The tuning range extended continuously from 2.068 mu m to 2.191 mu m with a maximum output power of 3.29 W at 24 kHz, corresponding to an optical-optical conversion efficiency (from 808 nm to 2 mu m) of 20.69%. The stable pulsed dual-wavelength operation provided an ideal pump source for generating terahertz wave of micro-watt level by the difference frequency generation (DFG) method. A 7.84-mm-long periodically inverted quasi-phase-matched (QPM) GaAs crystal with 6 periods was used to generate a terahertz wave, the maximum voltage of 180 mV at 1.244 THz was acquired by a 4.2-K Si bolometer, corresponding to average output power of 0.6 mu W and DFG conversion efficiency of 4.32x10(-7). The acceptance bandwidth was found to be larger than 0.35 THz (FWHM). As to the 15-mm-long GaSe crystal used in the type-II collinear DFG, a tunable THz source ranging from 0.503 THz to 3.63 THz with the maximum output voltage of 268 mV at 1.65 THz had been achieved, and the corresponding average output power and DFG conversion efficiency were 0.9 mu W and 5.86x10(-7) respectively. This provides a potential practical palm-top tunable THz sources for portable applications.
|
2 |
VLSI design and implementation of a parallel sorterMao, Hsein-Jung Joey January 1988 (has links)
No description available.
|
3 |
Optical Excitation in Scanning Tunneling Microscopy: From Surface Photovoltages to Charge Dynamics oin the Atomic ScaleKloth, Philipp 15 December 2016 (has links)
No description available.
|
4 |
ZnO/GaAs-based acoustic waves microsensor for the detection of bacteria in complex liquid media / Microapteur à ondes acoustiques en ZnO/GaAs pour la détection de bactéries en milieux liquides complexesChawich, Juliana 28 May 2019 (has links)
Cette thèse s’inscrit dans le cadre d’une cotutelle internationale entre l’Université de Bourgogne Franche-Comté en France et l’Université de Sherbrooke au Canada. Elle porte sur le développement d'un biocapteur miniature pour la détection et la quantification de bactéries dans des milieux liquides complexes. La bactérie visée est l’Escherichia coli (E. coli), régulièrement mise en cause dans des épidémies d'infections alimentaires, et parfois meurtrière.La géométrie du biocapteur consiste en une membrane en arséniure de gallium (GaAs) sur laquelle est déposé un film mince piézoélectrique d’oxyde de zinc (ZnO). L'apport du ZnO structuré en couche mince constitue un réel atout pour atteindre de meilleures performances du transducteur piézoélectrique et consécutivement une meilleure sensibilité de détection. Une paire d'électrodes déposée sur le film de ZnO permet de générer sous une tension sinusoïdale une onde acoustique se propageant dans le GaAs, à une fréquence donnée. La face arrière de la membrane, quant à elle, est fonctionnalisée avec une monocouche auto-assemblée (SAM) d'alkanethiols et des anticorps anti-E. coli, conférant la spécificité de la détection. Ainsi, le biocapteur bénéficie à la fois des technologies de microfabrication et de bio-fonctionnalisation du GaAs, déjà validées au sein de l’équipe de recherche, et des propriétés piézoélectriques prometteuses du ZnO, afin d’atteindre potentiellement une détection hautement sensible et spécifique de la bactérie d’intérêt. Le défi consiste à pouvoir détecter et quantifier cette bactérie à de très faibles concentrations dans un échantillon liquide et/ou biologique complexe.Les travaux de recherche ont en partie porté sur les dépôts et caractérisations de couches minces piézoélectriques de ZnO sur des substrats de GaAs. L’effet de l’orientation cristalline du GaAs ainsi que l’utilisation d’une couche intermédiaire de Platine entre le ZnO et le GaAs ont été étudiés par différentes techniques de caractérisation structurale (diffraction des rayons X, spectroscopie Raman, spectrométrie de masse à ionisation secondaire), topographique (microscopie à force atomique), optique (ellipsométrie) et électrique. Après la réalisation des contacts électriques, la membrane en GaAs a été usinée par gravure humide. Une fois fabriqué, le transducteur a été testé en air et en milieu liquide par des mesures électriques, afin de déterminer les fréquences de résonance pour les modes de cisaillement d’épaisseur. Un protocole de bio-fonctionnalisation de surface, validé au sein du laboratoire, a été appliqué à la face arrière du biocapteur pour l’ancrage des SAMs et des anticorps, tout en protégeant la face avant. De plus, les conditions de greffage d’anticorps en termes de concentration utilisée, pH et durée d’incubation, ont été étudiées, afin d’optimiser la capture de bactérie. Par ailleurs, l’impact du pH et de la conductivité de l’échantillon à tester sur la réponse du biocapteur a été déterminé. Les performances du biocapteur ont été évaluées par des tests de détection de la bactérie cible, E. coli, tout en corrélant les mesures électriques avec celles de fluorescence. Des tests de détection ont été réalisés en variant la concentration d’E. coli dans des milieux de complexité croissante. Différents types de contrôles ont été réalisés pour valider les critères de spécificité. En raison de sa petite taille, de son faible coût de fabrication et de sa réponse rapide, le biocapteur proposé pourrait être potentiellement utilisé dans les laboratoires de diagnostic clinique pour la détection d’E. coli. / This thesis was conducted in the frame of an international collaboration between Université de Bourgogne Franche-Comté in France and Université de Sherbrooke in Canada. It addresses the development of a miniaturized biosensor for the detection and quantification of bacteria in complex liquid media. The targeted bacteria is Escherichia coli (E. coli), regularly implicated in outbreaks of foodborne infections, and sometimes fatal.The adopted geometry of the biosensor consists of a gallium arsenide (GaAs) membrane with a thin layer of piezoelectric zinc oxide (ZnO) on its front side. The contribution of ZnO structured in a thin film is a real asset to achieve better performances of the piezoelectric transducer and consecutively a better sensitivity of detection. A pair of electrodes deposited on the ZnO film allows the generation of an acoustic wave propagating in GaAs under a sinusoidal voltage, at a given frequency. The backside of the membrane is functionalized with a self-assembled monolayer (SAM) of alkanethiols and antibodies anti-E. coli, providing the specificity of detection. Thus, the biosensor benefits from the microfabrication and bio-functionalization technologies of GaAs, validated within the research team, and the promising piezoelectric properties of ZnO, to potentially achieve a highly sensitive and specific detection of the bacteria of interest. The challenge is to be able to detect and quantify these bacteria at very low concentrations in a complex liquid and/or biological sample.The research work partly focused on the deposition and characterization of piezoelectric ZnO thin films on GaAs substrates. The effect of the crystalline orientation of GaAs and the use of a titanium / platinum buffer layer between ZnO and GaAs were studied using different structural (X-ray diffraction, Raman spectroscopy, secondary ionization mass spectrometry), topographic (atomic force microscopy), optical (ellipsometry) and electrical characterizations. After the realization of the electrical contacts on top of the ZnO film, the GaAs membrane was micromachined using chemical wet etching. Once fabricated, the transducer was tested in air and liquid medium by electrical measurements, in order to determine the resonance frequencies for thickness shear mode. A protocol for surface bio-functionalization, validated in the laboratory, was applied to the back of the biosensor for anchoring SAMs and antibodies, while protecting the top side. Furthermore, different conditions of antibody grafting such as the concentration, pH and incubation time, were tested to optimize the immunocapture of bacteria. In addition, the impact of the pH and the conductivity of the solution to be tested on the response of the biosensor has been determined. The performances of the biosensor were evaluated by detection tests of the targeted bacteria, E. coli, while correlating electrical measurements with fluorescence microscopy. Detection tests were completed by varying the concentration of E. coli in environments of increasing complexity. Various types of controls were performed to validate the specificity criteria. Thanks to its small size, low cost of fabrication and rapid response, the proposed biosensor has the potential of being applied in clinical diagnostic laboratories for the detection of E. coli.
|
5 |
Le procédé HVPE pour la croissance de nanofils semiconducteurs III-V / The HVPE process for the growth of III-V semiconductor nanowiresLekhal, Kaddour 18 February 2013 (has links)
Cette thèse est consacrée à l’étude de l’outil d’épitaxie HVPE (Hydride Vapour Phase Epitaxy) pour la synthèse avec et sans catalyseur de nanofils semiconducteurs GaN et GaAs. Une étude systématique de l’influence des conditions expérimentales sur la croissance des fils de GaN est effectuée, afin de démontrer la faisabilité de cette croissance sur la surface des substrats saphir plan-c et silicium sans aucun traitement de la surface préalablement à la croissance. Nous avons démontré la croissance par VLS-HVPE, de nanofils de GaN de diamètres constants de 40 à 200 nm, de longueurs supérieures à 60 μm et présentant des qualités optique et cristallographique remarquables. Pour les nanofils de GaAs, la stabilité, inédite, de la phase cubique zinc-blende pour des diamètres de 10 nm a été démontrée par le procédé de croissance VLS-HVPE sur des longueurs de quelques dizaines de micromètres. Les mécanismes de croissance sont discutés à partir des diagrammes de phase et de la physique de la croissance HVPE qui met en oeuvre des précurseurs gazeux chlorés. Pour les semiconducteurs III-V, cette étude permet d’envisager des applications liées aux nanofils longs qui jusque là n’étaient exploitées que pour le silicium. Ces travaux montrent que dans le contexte des Nanosciences, la HVPE, outil épitaxial à fortes vitesses de croissance, mérite une audience élargie, et peut s’inscrire comme un outil complémentaire efficace aux procédés MOVPE et MBE pour le façonnage contrôlé de la matière à l’échelle nanométrique. / This thesis is devoted to the study of HVPE (Hydride Vapour Phase Epitaxy) method of growing GaN and GaAs nanowires with and without catalyst. A systematic study of the influence of the growth conditions on GaN formation was performed in order to demonstrate the feasibility of this growth on c-plane sapphire and silicon substrates without preliminary treatment of the surface. We have demonstrated by VLS-HVPE the growth of the GaN nanowires with constant diameters of 40 to 200 nm and of length up to 60 μm, while they possess remarkable optical and crystal quality. The newly observed stability of the zinc blende structure for GaAs nanowires with diameters of 10 nm has been described by the VLS-HVPE process, for lengths of few tens of micrometers. The growth mechanisms are discussed based on the phase diagram and the physics of near-equilibrium HVPE using chloride precursors. For III-V semiconductors, the study allows us to consider applications related to long nanowires that, at present, are used only for silicon. This work shows that in the context of Nanoscience, the fast growth HVPE method deserves a wider audience and thus could be considered as an effective complementary tool to MOVPE and MBE processes for the controlled shaping of matter on the nanoscale.
|
Page generated in 0.0772 seconds