• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Representação da variação da frequência em estudos de segurança de tensão de sistemas elétricos de potência

Almeida, Thiago Resende de 30 October 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-03-21T17:50:55Z No. of bitstreams: 1 thiagoresendedealmeida.pdf: 4974622 bytes, checksum: 0f8c86117d7625e1546498cd6c17f367 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-04-24T02:16:26Z (GMT) No. of bitstreams: 1 thiagoresendedealmeida.pdf: 4974622 bytes, checksum: 0f8c86117d7625e1546498cd6c17f367 (MD5) / Made available in DSpace on 2016-04-24T02:16:26Z (GMT). No. of bitstreams: 1 thiagoresendedealmeida.pdf: 4974622 bytes, checksum: 0f8c86117d7625e1546498cd6c17f367 (MD5) Previous issue date: 2013-10-30 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O principal objetivo deste trabalho é avaliar a influência da variação dos parâmetros da rede elétrica em função da frequência do sistema em estudos relacionados à avaliação da segurança de tensão de Sistemas Elétricos de Potência (SEP). Neste sentido, é proposta uma alteração na formulação denominada Fluxo de Potência com Regulação Primária. Tal formulação representa uma modelagem alternativa do problema de Fluxo de Potência, onde a frequência do sistema pode ser estimada com precisão satisfatória. É importante destacar que a metodologia proposta neste trabalho mantém a formulação full Newton do problema. A partir deste contexto são consideradas as variações dos parâmetros da rede, tais como shunts de barra, shunts de linha e o modelo de Linhas de Transmissão e Transformadores, tornando estes parâmetros dependentes com os desvios de frequência do sistema. É também realizada uma avaliação das cargas tipo motor de indução. Assim como os parâmetros da rede, os parâmetros do motor de indução são modificados de acordo com os desvios de frequência do sistema. Em seguida são desenvolvidos estudos de avaliação da segurança de tensão a partir do desenvolvimento e implementação de um Fluxo de Potência Continuado modificado e de uma formulação alternativa do problema de Fluxo de Potência Ótimo (FPO). A partir dessas ferramentas é possível avaliar a variação da frequência do sistema em função do aumento do seu carregamento. Também são feitas análises a partir dos autovalores da matriz Jacobiana do método proposto. Finalmente são utilizados cinco sistemas de pequeno e médio portes para a validação da metodologia proposta. Além de dois sistemas tutoriais de pequeno porte, é utilizado o sistema 16 Barras, que é um sistema criado a partir de dados reais e condições operativas encontradas no Sistema Interligado Nacional (SIN), os sistemas New England e IEEE-118 Barras, que são sistemas testes normalmente utilizados na literatura. O programa ANATEM, desenvolvido pelo CEPEL, é utilizado de forma a validar os desenvolvimentos realizados neste trabalho. / The main objective of this work is to evaluate the influence of varying the network parameters depending on the system frequency in studies related to the voltage security assessment of Electric Power Systems. In this sense, it is proposed a modification in the formulation of the called Governor Power Flow. Such formulation represents an alternative modeling of the power flow problem, where the system frequency can be estimated with satisfactory accuracy. It is important to highlight that in this work the proposed methodology retains full Newton formulation of the problem. From this context it is considered variations of the network parameters, such as shunt devices (capacitors and reactors) and equivalent models of transmission lines and transformers, making them dependent parameters with frequency system. It is also studied the induction motor modeling. As the network parameters, the parameters of the induction motor are modified according to the deviation of system frequency. Then voltage security assessment studies are carried out through the development and implementation of a Modified Continuation Power Flow and an Optimal Power Flow. Using these tools it is possible to evaluate the system frequency variation due to the increase of the system loading. Analyzes are also made using the eigenvalues of the Jacobian matrix associated with the proposed methodology. Finally six systems of small and medium scale are used in validation process of the proposed methodology. In addition to two tutorials small systems are used a 16 buses test system, which is created from real data and operating conditions found in the Interconnected Brazilian System, the well know New England system and the IEEE-118 buses test systems, which are systems commonly used in the literature. The ANATEM program, developed by CEPEL, is used to validate the developments made in this work.
2

Um novo modelo para representação da regulação primária e secundária de frequência no problema de fluxo de potência e fluxo de potência ótimo

La Gatta, Paula Oliveira 05 March 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-01T14:29:29Z No. of bitstreams: 1 paulaoliveiralagatta.pdf: 1917786 bytes, checksum: 627585584595873c205fcbcf5c79980f (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T16:01:23Z (GMT) No. of bitstreams: 1 paulaoliveiralagatta.pdf: 1917786 bytes, checksum: 627585584595873c205fcbcf5c79980f (MD5) / Made available in DSpace on 2016-07-13T16:01:23Z (GMT). No. of bitstreams: 1 paulaoliveiralagatta.pdf: 1917786 bytes, checksum: 627585584595873c205fcbcf5c79980f (MD5) Previous issue date: 2012-03-05 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho são propostas duas formulações de importantes ferramentas para análise de redes em regime permanente, onde são consideradas equações que descrevem o comportamento do controle primário e secundário de frequência em sistemas elétricos de potência. A primeira proposta é baseada em uma formulação do problema de fluxo de potência convencional e a segunda uma formulação do fluxo de potência ótimo. A formulação de fluxo de potência proposta é desenvolvida a partir de uma metodologia genérica de representação de dispositivos de controle. Esta metodologia consiste em incorporar as equações que modelam dispositivos de controle ao problema básico de fluxo de potência em coordenadas polares, formando um sistema de equações de ordem (2nb+nc). O fluxo de potência desenvolvido é capaz de estimar os desvios de frequência do sistema devido a uma perturbação da carga. Por outro lado, o fluxo de potência ótimo proposto é capaz de identificar montantes e locais de corte carga, de forma a manter a frequência do sistema em uma faixa aceitável de operação. A formulação proposta de FPO consiste em incluir no problema equações de igualdade e desigualdade associadas com o controle primário de frequência e geração de potência ativa. Os desenvolvimentos propostos para o fluxo de potência convencional foram implementados no ambiente MatLab®. Para solução do fluxo de potência ótimo utilizou-se um pacote comercial de otimização, denominado LINGO®. A avaliação do fluxo de potência e fluxo de potência ótimo propostos é feita através do estudo de sistemas tutoriais e do sistema New England. A validação da análise de desvios de frequência é feita através da utilização do programa ANATEM, desenvolvido pelo CEPEL. Os resultados obtidos mostram as vantagens da utilização das formulações propostas. / This work proposes a new formulation for both the conventional power flow and the optimal power flow formulation, in which the steady-state equations describing the primary and secondary frequency control in electrical power systems are included. The proposed power flow formulation is based on a flexible methodology for the representation of control devices. Such methodology incorporates equations that model control devices into the basic power flow formulation in polar coordinates, generating an augmented system of equations having order (2nb + nc). The developed power flow is able to estimate the system frequency deviation due to a load disturbance. On other hand, the proposed optimum power flow formulation is able to identify the minimum load shedding necessary to maintain the system frequency in an acceptable range of operation. The proposed OPF formulation includes additional equality and inequality constraints to represent the steady state primary frequency control as a function of the active power generation. The proposed development for the conventional power flow was made using the MATLAB® environment. The optimal power flow solution used a commercial optimization package called LINGO®. The evaluation of the proposed power flow and optimal power flow formulations were made through the study of small test systems and the New England test system. Validations of the frequency deviation analysis were made using the program ANATEM, developed by CEPEL. The results obtained show the advantages of using the proposed formulations.

Page generated in 0.081 seconds