• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • Tagged with
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Hydraulic Tomography: Field and Laboratory Experiments

Berg, Steven January 2011 (has links)
Accurately characterizing the distribution of hydraulic parameters is critical for any site investigation, particularly those dealing with solute or contaminant transport. Despite the fact that many tools are currently available for both characterizing (e.g. soil core analysis, slug and pumping tests, direct push techniques, etc.,) and modeling (e.g. geostatistical interpolators, construction of geological models, etc.,) heterogeneous aquifers, this still remains a challenge. In this thesis, hydraulic tomography (HT), a recently developed tool for characterizing and modeling heterogeneous aquifers is evaluated under both laboratory and field conditions. To date, both steady state hydraulic tomography (SSHT) and transient hydraulic tomography (THT) have been demonstrated at the laboratory scale, however, only SSHT has been rigorously validated through the prediction of independent tests (those not used for estimating the distribution of hydraulic parameters), and comparison to other characterization/modeling techniques. Additionally, laboratory and field validations of HT using comparisons other than the prediction of independent pumping tests (e.g. prediction of solute transport) are lacking. The laboratory studies performed in this thesis address some of these gaps by: i) rigorously validating THT through the prediction of independent pumping tests, and comparison to other characterization techniques; ii) using HT estimated parameter distributions to predict the migration of a conservative tracer in a heterogeneous sandbox aquifer; and, iii) predicting the flow of water to a well in a heterogeneous, unconfined, sandbox aquifer. For all three cases, HT was compared to more traditional characterization/modeling approaches, such as; the calculation of homogeneous effective parameters, kriging of point data, or the creation and calibration of a geological model. For each study the performance of HT was superior to the other characterization methods. These laboratory experiments demonstrated both the ability of HT to map aquifer heterogeneity, and the critical need for accurately understanding heterogeneity in order to make accurate predictions about a system. In this regard, HT is a powerful tool at the laboratory scale where the forcing functions (i.e., boundary conditions, flow rates, etc.,) are accurately known. While several field scale HT studies have been reported in the literature, none attempt to validate 3D THT through the prediction of independent pumping tests, or through comparison to known geology. The application of THT at the field scale presents unique challenges not faced in the laboratory setting. For example, boundary conditions are not accurately known and it is not possible to instrument a field site as densely as a sandbox aquifer. In the field studies conducted as part of this thesis, THT was validated by comparing estimated hydraulic parameter fields to known geology (borehole data) and simulating 9 pumping tests that were performed at the site. The THT analysis was able to capture the salient features of the aquifer (the presence of a double aquifer separated by an aquitard), and was able to reasonably reproduce most of the pumping tests. For comparison purposes, a homogeneous model and three additional heterogeneous models were created: i) permeameter estimates of hydraulic conductivity from soil cores were interpolated via kriging; ii) the transition probability/Markov Chain approach was used to interpret material classifications from borehole logs; and iii) a stratigraphic model was created and calibrated to pumping test data. Of these cases, THT and the calibrated stratigraphic model performed best, with THT performing slightly better. This work indicates that it is possible to interpret multiple pumping tests using hydraulic tomography to estimate the 3D distribution of hydraulic parameters in heterogeneous aquifer systems. Also, since hydraulic tomography does not require the collection and analysis of a large number of point samples, it is likely comparable in cost to other characterization/modeling approaches.
2

Hydraulic Tomography: Field and Laboratory Experiments

Berg, Steven January 2011 (has links)
Accurately characterizing the distribution of hydraulic parameters is critical for any site investigation, particularly those dealing with solute or contaminant transport. Despite the fact that many tools are currently available for both characterizing (e.g. soil core analysis, slug and pumping tests, direct push techniques, etc.,) and modeling (e.g. geostatistical interpolators, construction of geological models, etc.,) heterogeneous aquifers, this still remains a challenge. In this thesis, hydraulic tomography (HT), a recently developed tool for characterizing and modeling heterogeneous aquifers is evaluated under both laboratory and field conditions. To date, both steady state hydraulic tomography (SSHT) and transient hydraulic tomography (THT) have been demonstrated at the laboratory scale, however, only SSHT has been rigorously validated through the prediction of independent tests (those not used for estimating the distribution of hydraulic parameters), and comparison to other characterization/modeling techniques. Additionally, laboratory and field validations of HT using comparisons other than the prediction of independent pumping tests (e.g. prediction of solute transport) are lacking. The laboratory studies performed in this thesis address some of these gaps by: i) rigorously validating THT through the prediction of independent pumping tests, and comparison to other characterization techniques; ii) using HT estimated parameter distributions to predict the migration of a conservative tracer in a heterogeneous sandbox aquifer; and, iii) predicting the flow of water to a well in a heterogeneous, unconfined, sandbox aquifer. For all three cases, HT was compared to more traditional characterization/modeling approaches, such as; the calculation of homogeneous effective parameters, kriging of point data, or the creation and calibration of a geological model. For each study the performance of HT was superior to the other characterization methods. These laboratory experiments demonstrated both the ability of HT to map aquifer heterogeneity, and the critical need for accurately understanding heterogeneity in order to make accurate predictions about a system. In this regard, HT is a powerful tool at the laboratory scale where the forcing functions (i.e., boundary conditions, flow rates, etc.,) are accurately known. While several field scale HT studies have been reported in the literature, none attempt to validate 3D THT through the prediction of independent pumping tests, or through comparison to known geology. The application of THT at the field scale presents unique challenges not faced in the laboratory setting. For example, boundary conditions are not accurately known and it is not possible to instrument a field site as densely as a sandbox aquifer. In the field studies conducted as part of this thesis, THT was validated by comparing estimated hydraulic parameter fields to known geology (borehole data) and simulating 9 pumping tests that were performed at the site. The THT analysis was able to capture the salient features of the aquifer (the presence of a double aquifer separated by an aquitard), and was able to reasonably reproduce most of the pumping tests. For comparison purposes, a homogeneous model and three additional heterogeneous models were created: i) permeameter estimates of hydraulic conductivity from soil cores were interpolated via kriging; ii) the transition probability/Markov Chain approach was used to interpret material classifications from borehole logs; and iii) a stratigraphic model was created and calibrated to pumping test data. Of these cases, THT and the calibrated stratigraphic model performed best, with THT performing slightly better. This work indicates that it is possible to interpret multiple pumping tests using hydraulic tomography to estimate the 3D distribution of hydraulic parameters in heterogeneous aquifer systems. Also, since hydraulic tomography does not require the collection and analysis of a large number of point samples, it is likely comparable in cost to other characterization/modeling approaches.
3

Estudo da contaminação do lençol freático através da integração de técnicas geofísicas e geoquímicas em Ji-Paraná-RO

Silva, Ariveltom Cosme da [UNESP] 04 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-12-04Bitstream added on 2014-06-13T18:43:31Z : No. of bitstreams: 1 silva_ac_dr_rcla.pdf: 5801174 bytes, checksum: 92d008f9d5ed42a27b436eeed43ca551 (MD5) / A Cidade de Ji-Paraná, no Estado de Rondônia, tal como ocorre em muitas cidades brasileiras, não possui sistema público de coleta e tratamento de esgotos. Assim, águas residuárias produzidas pela população são lançadas em sistemas rústicos, fossas negras ou sépticas. Por outro lado, muitos habitantes utilizam água subterrânea extraída de poços cacimba ou tubulares rasos. Em razão da possibilidade de contaminação das águas subterrâneas por elementos oriundos do sistema séptico, tomou-se o Bairro Nova Brasília como área de estudo. Verificou-se, através de análises biológicas e físico-químicas das águas, a presença de coliformes fecais e totais, além de altas concentrações de nitrato no aqüífero. Em vista disso, foram realizados na área, ensaios geoelétricos de resistividade com as técnicas de Sondagem Elétrica Vertical (arranjo Schlumberger) e Caminhamento Elétrico (arranjo dipolo-dipolo) para determinar a extensão da pluma contaminante. Os ensaios geofísicos aplicados permitiram uma visão das heterogeneidades do meio hidrogeológico e o resultado dos ensaios mostrou-se bastante satisfatório na detecção da pluma de contaminação oriunda das inúmeras fossas, caracterizada por zonas de anomalias condutivas. Portanto, este estudo indica que a utilização de águas de aqüíferos freáticos urbanos rasos, desprovidos de um sistema de saneamento público, deve ser feita com cautela. / The city of Ji-Paraná in the State of Rondônia, does not have a public system of sewage drainage and treatment as happens in many Brazilian cities. This way, the wastewater produced by the population is drained toward rustic systems like concrete cesspool or cesspool. In the other hand, many people use groundwater extracted from wells. Due to the possibility of groundwater contamination for elements from these systems, the neighborhood of Nova Brasília was taken as a case study, the New Brasilia Neighborhood. It was verified by biological, physical-chemical and physical analysis of the wastewater the existence of fecal coliforms and total besides high concentration of nitrate in the aquiferous. Due to these facts, resistivity geoelectrical assays in the area, using the Vertical Electric Sounding- VES (Schlumberger array) and imaging profiles 2D (dipole-dipole array) to determine the extension of the contamination. The applied geophysical assays allowed a heterogenic view of the hydrogeology of the environment and the results were considered satisfactory in the detection of the contamination from the countless cesspits, featured by conductive anomalous zones. Therefore, this study indicates that the usage of urban low-level aquiferous water in lack of a public sanitation system must be done cautiously.
4

Estudo da contaminação do lençol freático através da integração de técnicas geofísicas e geoquímicas em Ji-Paraná-RO /

Silva, Ariveltom Cosme da. January 2008 (has links)
Orientador: João Carlos Dourado / Banca: Didier Gastmans / Banca: Walter Malagutti Filho / Banca: Vagner Roberto Elis / Banca: Alex Vladimir Krusche / Resumo: A Cidade de Ji-Paraná, no Estado de Rondônia, tal como ocorre em muitas cidades brasileiras, não possui sistema público de coleta e tratamento de esgotos. Assim, águas residuárias produzidas pela população são lançadas em sistemas rústicos, fossas negras ou sépticas. Por outro lado, muitos habitantes utilizam água subterrânea extraída de poços cacimba ou tubulares rasos. Em razão da possibilidade de contaminação das águas subterrâneas por elementos oriundos do sistema séptico, tomou-se o Bairro Nova Brasília como área de estudo. Verificou-se, através de análises biológicas e físico-químicas das águas, a presença de coliformes fecais e totais, além de altas concentrações de nitrato no aqüífero. Em vista disso, foram realizados na área, ensaios geoelétricos de resistividade com as técnicas de Sondagem Elétrica Vertical (arranjo Schlumberger) e Caminhamento Elétrico (arranjo dipolo-dipolo) para determinar a extensão da pluma contaminante. Os ensaios geofísicos aplicados permitiram uma visão das heterogeneidades do meio hidrogeológico e o resultado dos ensaios mostrou-se bastante satisfatório na detecção da pluma de contaminação oriunda das inúmeras fossas, caracterizada por zonas de anomalias condutivas. Portanto, este estudo indica que a utilização de águas de aqüíferos freáticos urbanos rasos, desprovidos de um sistema de saneamento público, deve ser feita com cautela. / Abstract: The city of Ji-Paraná in the State of Rondônia, does not have a public system of sewage drainage and treatment as happens in many Brazilian cities. This way, the wastewater produced by the population is drained toward rustic systems like concrete cesspool or cesspool. In the other hand, many people use groundwater extracted from wells. Due to the possibility of groundwater contamination for elements from these systems, the neighborhood of Nova Brasília was taken as a case study, the New Brasilia Neighborhood. It was verified by biological, physical-chemical and physical analysis of the wastewater the existence of fecal coliforms and total besides high concentration of nitrate in the aquiferous. Due to these facts, resistivity geoelectrical assays in the area, using the Vertical Electric Sounding- VES (Schlumberger array) and imaging profiles 2D (dipole-dipole array) to determine the extension of the contamination. The applied geophysical assays allowed a heterogenic view of the hydrogeology of the environment and the results were considered satisfactory in the detection of the contamination from the countless cesspits, featured by conductive anomalous zones. Therefore, this study indicates that the usage of urban low-level aquiferous water in lack of a public sanitation system must be done cautiously. / Doutor

Page generated in 0.0593 seconds