• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 475
  • 220
  • 17
  • 6
  • 6
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 727
  • 225
  • 183
  • 145
  • 129
  • 123
  • 104
  • 80
  • 77
  • 76
  • 69
  • 65
  • 63
  • 56
  • 53
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

Estudo das condicionantes hidráulicas de uma ruptura de talude em São Vendelino (RS) / Study of the hydraulic conditioning factors of a slope failure at São Vendelino (RS)

Martinello, Isac Alexandre January 2006 (has links)
A presente dissertação apresenta um estudo experimental e de simulação de fluxo de água investigando os efeitos de chuvas torrenciais sobre o solo existente em um talude da região de São Vendelino. Para este estudo foi selecionada uma encosta na qual houve duas ocorrências de rupturas rasas que deram origem a corridas de detritos num evento importante que ocorreu no local em dezembro de 2000. Ao longo da cicatriz deixada por uma delas, foram realizados ensaios de caracterização e determinadas as propriedades hidráulicas do solo a partir de ensaios de campo e de laboratório. Os ensaios de campo compreenderam ensaios com o permeâmetro de Guelph, ensaios com piezômetros de tubo aberto e infiltrômetro de anel duplo. Em laboratório foram realizados ensaios utilizando dois diferentes permeâmetros de parede flexível. Foi feita também a determinação da curva característica do solo através do método do papel-filtro. A partir das propriedades hidráulicas do solo, da geometria do talude e espessura dos materiais, obtidas a partir de topografia, foram realizadas análises de fluxo utilizando o programa Seep/W simulando a precipitação medida de 148 mm/2 h que deflagrou as corridas de detritos de dezembro de 2000. As análises mostraram que, como o solo coluvionar tem uma condutividade hidráulica bastante elevada, ocorre a infiltração de toda a chuva ocorrida. As análises de fluxo mostraram uma elevação progressiva do nível freático com o tempo, o qual atinge a superfície do terreno no trecho crítico do talude (trecho de maior inclinação) após cerca de 95 minutos de precipitação. Análises de estabilidade simplificadas (talude infinito) mostram fatores de segurança próximos da unidade com o nível freático em 80% da camada de solo coluvionar, considerando o trecho mais íngreme do talude. Embora com algumas simplificações de análise, estes resultados mostram que as análises de fluxo e de ruptura, utilizando dados reais medidos em campo, são muito promissores pois conseguem modelar de forma adequada a ruptura ocorrida (FS=1,0). / This dissertation presents an experimental study and a simulation of hydraulic flow in a slope at São Vendelino region, to investigate the effects of torrential rains on the existing soil. A natural slope was selected in which two shallow slope failures had occurred in December 2000 during a serious debris flow event. Soil characterization tests and hydraulic properties have been determined in the laboratory on soil samples taken close to one of the scars left by the failures. The field tests involved Guelph permeameter, stand pipe piezometers and doublering infiltrometer tests. Tests on two different flexible wall permeameter tests and the determination of the moisture-suction characteristic curve have also been carried out in the laboratory. Using the measured soil hydraulic properties, the slope geometry and soil covering depths obtained through topography, some hydraulic flow analyses have been carried out. The SEEP/W software was used and the measured precipitation of 148mm/ 2h, which caused the debris flow event of December 2000, was simulated. The analyses have shown that all the precipitation can infiltrate, as the soil has a large hydraulic conductivity, and there is a progressive rising of the phreatic line with time. This level of water reaches the soil surface in the critical length of the slope (the length with the larger inclination) after 95 min of rain. Simplified slope stability analysis (infinite slopes) had shown values of safety factors close to one in the critical length of the slope when the phreatic line is at 80% depth of the colluvium soil. Although there are some simplifications in the analysis, these results show that the flow and the stability analyses using the real data collected from field tests modeled in an appropriate way the real failure (FS~1,0).
372

Condutividade hidráulica em solos contaminados encapsulados

Cruz, Rodrigo Caberlon January 2004 (has links)
No presente trabalho, a técnica de solidificação/estabilização de solos contaminados, foi analisada por meio de ensaios de resistência à compressão simples e ensaios de condutividade hidráulica em permeâmetro de parede flexível. O solo residual de arenito Botucatu (SRAB) foi utilizado como matriz, o óleo diesel foi utilizado como contaminante, e o cimento Portland CP V – ARI foi utilizado como o agente cimentante. Foram realizadas microscopias petrográficas dos materiais encapsulados, no intuito de analisar a estrutura do material para diferentes porcentagens de óleo diesel. Para os ensaios de condutividade hidráulica foi projetado e construído um permeâmetro de parede flexível, conforme a norma Americana ASTM D 5084/90, com adaptações para ensaiar amostras contaminadas, percoladas com água ou com percolados químicos. Para os ensaios de resistência à compressão simples utilizou-se de 0 a 50% de cimento (em relação ao peso de solo seco) e de 0 a 100% de contaminante (em relação ao peso de líquidos na amostra), correspondente à umidade ótima da amostra obtida através do ensaio de compactação. Para os ensaios de condutividade hidráulica foram utilizados os percentuais de 0 a 30% de cimento e 0 a 40% de óleo diesel. A resistência à compressão simples aumenta quanto maior for a quantidade de cimento, e diminui quanto maior for a quantidade de contaminante. Em amostras sem óleo diesel, a condutividade hidráulica diminui quanto maior for a quantidade de cimento. Para amostras sem cimento, a condutividade hidráulica diminui para quantidades de até 20% de óleo diesel, voltando a aumentar para quantidades maiores de 20% de óleo Para o SRAB com adição de cimento e óleo diesel, verifica-se uma tendência no comportamento, onde inicialmente a condutividade hidráulica diminui e volta a aumentar com o aumento da quantidade de óleo diesel. Foi observado que quanto maior a quantidade de cimento, menor a quantidade de óleo diesel necessária para a obtenção do mínimo valor de condutividade hidráulica para o material.
373

Estudo do comportamento hidráulico, mecânico e químico de barreiras hidráulicas verticais, compostas por solo residual, bentonita e cimento sob ação de substâncias agressivas / Study of the hydraulic, mechanic and chemical behavior of verticals hydraulic barriers composed by sandy soil, bentonite and cement under aggressive substances’ action

Lemos, Rosemar Gomes January 2006 (has links)
Este estudo tem como objetivo analisar os comportamentos hidráulico, mecânico e microestrutural de misturas compostas, por solo residual arenito Botucatu e bentonita sódica, com e sem adição de cimento, quando permeadas por água (H2O), soda cáustica (NaOH), na concentração de 5% e ácido sulfúrico (H2SO4) na mesma concentração para sua possível utilização em barreiras de contenção de contaminantes do tipo slurry wall. O arenito, solo areno-siltoso característico da região de São Leopoldo/ RS, compõe a matriz das misturas, sendo que a bentonita sódica confere a estas características impermeabilizantes, imprescindíveis às barreiras hidráulicas de contenção. O cimento, além de fazer com que a mistura adquira resistência, interfere na reatividade da barreira, mediante os contaminantes utilizados. A estimativa da eficiência destas misturas baseou-se na comparação entre os valores do coeficiente de condutividade hidráulica, resistência à compressão simples e parâmetros de compressibilidade determinados através dos ensaios de compressão confinada, apresentados nos ensaios com e sem contaminação, conjuntamente com a análise microestrutural das misturas nas mesmas situações. Foram feitas análises químicas por Difração de Raios-x, Microscopia Eletrônica de Varredura (SEM) e Análise Química Elementar (EDS) visando à explicação ordinária das causas microestruturais que levam as misturas a determinado comportamento sob percolação de contaminantes. Na busca do efeito de cada componente sobre o comportamento final de determinada mistura, houve a necessidade de realizar análises químicas e microscópicas individuais, também sob interferência ou não de substâncias agressivas. A partir deste estudo foi possível inferir que a mistura solo-cimentobentonita, é adequada à utilização como barreira vertical quando o contaminante for ácido sulfúrico, por no mínimo 20 semanas, já que a eficiência da mesma foi comprovada pela realização de ensaios no permeâmetro de parede rígida, considerado adequado para este tipo. O uso da mistura solo bentonita para barreiras verticais pode ser emergencial visto que quando o contaminante for soda cáustica a mistura resiste por 4 dias. / The objective of this study is to analyze the hydraulic, mechanical and micro-structural conduct of composite mixtures of Botucatu residual soil and sodic bentonite, with and without cement addition, when permeated by water (H2O), caustic soda (NaOH) in a concentration of 5% and sulfuric acid in the same concentration to their possible utilization in contention of contaminant barriers of the slurry walls type. The sandy soil constitutes part of the matrix of the mixtures. The sodic bentonite confers to these mixture essential waterproof characteristics of hydraulic barriers of containment. The cement interferes on the barrier reactivity moreover add resistance to the mixture by the contaminants that were utilized. The efficiency estimation of these mixtures was established by comparison between hydraulic conductive coefficient, unconfined compression strength and one dimensional compressibility presented on the tests with or without contamination, with the mixture micro-structural and chemical analysis on the same situations: X-ray diffraction, scanning electronic microscopy, Elemental Chemical Analysis (EDS), they want to explain the micro-structural causes that make the mixtures to determinate behavior by percolating of contaminants. Searching the effect of all components about the final behavior of determined mixture there was the necessity to carry out chemical and microscopically individual analysis also by aggressive or non-aggressive substances interference. After completed the study, it is possible to affirm that the soil-cement-bentonite mixture, is good for using as a vertical barrier when the contaminant is sulfuric acid, based on the results of rigid wall permeameter, adequate for this kind of mixture. The use of soilbentonite mixture as vertical barrier for caustic soda could be done just in emergency cases and for a short period of time, once that after some time the barrier reduces drastically its efficiency.
374

Aplicação do método dos elementos de contorno na simulação dos fenômenos dos cones de água e de gás em poços de petróleo horizontais

Gontijo, Gustavo Silva Vaz 02 December 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-04-01T16:26:47Z No. of bitstreams: 1 2015_GustavoSilvaVazGontijo.pdf: 2966352 bytes, checksum: 22a64bd241253dcb4f49a439c93d59f5 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-04-13T17:56:17Z (GMT) No. of bitstreams: 1 2015_GustavoSilvaVazGontijo.pdf: 2966352 bytes, checksum: 22a64bd241253dcb4f49a439c93d59f5 (MD5) / Made available in DSpace on 2016-04-13T17:56:17Z (GMT). No. of bitstreams: 1 2015_GustavoSilvaVazGontijo.pdf: 2966352 bytes, checksum: 22a64bd241253dcb4f49a439c93d59f5 (MD5) / Este trabalho apresenta um estudo sobre os fenômenos dos cones de água e de gás em poços de petróleo horizontais. O escopo é a modelagem numérica bidimensional dos fenômenos utilizando o Método dos Elementos de Contorno. Este texto traz uma revisão acerca destes fenômenos e de seu impacto na indústria de petróleo, de forma a situar o leitor sobre a motivação para o estudo do tema. São utilizados dois modelos de escoamento potencial, monofásico e bifásico. Um terceiro modelo, de escoamento compressível monofásico também é aplicado. Todo o tratamento matemático envolvido na dedução das equações governantes dos modelos é apresentado. Também estão presentes os desenvolvimentos matemáticos de três formulações do Método dos Elementos de Contorno. São elas a formulação para problemas regidos pela equação de Laplace, a formulação de Reciprocidade Dual para problemas regidos pela equação da difusividade e a formulação de sub-regiões, para problemas sobre domínios homogêneos por partes. O detalhamento do desenvolvimento matemático para a integração analítica das matrizes de influência é mostrado e utilizado para garantir uma melhor performance dos simuladores desenvolvidos. Uma alternativa na modelagem do poço de petróleo horizontal em domínio bidimensional é proposta, utilizando um conjunto de sumidouros pontuais para representar seu perímetro. Esta abordagem permite analisar de forma satisfatória o comportamento da interface entre fluidos, mesmo depois que ela já tenha tocado o poço. A implementação dos três simuladores é documentada de forma a permitir a utilização deste texto como consulta para implementações semelhantes. A determinação das condições de contorno para os três modelos, incluindo as condições de compatibilidade e equilíbrio na interface entre fluidos, é apresentada. Os simuladores propostos foram desenvolvidos e validados em comparação a resultados analíticos disponíveis. / This paper presents a study on water and gas coning phenomena in horizontal oil wells. The scope is their two-dimensional numerical modeling using the Boundary Element Method. This text provides a review of these phenomena including their impact on oil industry in order to situate the reader about the motivation for the study of this subject. Two potential flow models, single-phase and two-phase, are used. A third model, single-phase compressible flow is also applied. All the mathematical treatment involved in the deduction of the models' governing equations is presented. Also present are the mathematical developments of three formulations of the Boundary Element Method. They are the formulation for problems governed by the Laplace equation, the Dual Reciprocity formulation for problems governed by the diffusion equation, and the sub-regions formulation, for problems within a domain which is homogeneous by parts. The details of mathematical development for analytical integration of the influence matrices is shown and used to ensure better performance of the developed simulators. An alternative modeling of horizontal oil wells in two-dimensional domain is proposed, using a set of point sinks to represent its perimeter. This approach allows to satisfactorily analyze the behavior of fluids interface, even after it reaches the well. Implementation of the three simulators is documented to enable the use of this material as reference text for similar implementations. Determination of boundary conditions for the three models, including compatibility and equilibrium at the interface are presented. The proposed simulators were developed and validated in comparison to available analytical results.
375

Comparación de dos Métodos de Campo y uno de Laboratorio para la Medición de Conductividad Hidráulica Saturada en el Suelo

Pfeiffer Jakob, Marco January 2008 (has links)
Memoria para optar al título profesional de: Ingeniero Agrónomo / La conductividad hidráulica saturada del suelo (K s), es una propiedad física que es utilizada con diversos fines, tanto dentro como fuera del ámbito agrícola. Uno de estos lo constituyen los diseños de drenaje, para lo cual la conducti vidad hidráulica (Ks) es clave para definir la distancia a la que deben ir ub icados los drenes, siendo el mé todo del Pozo Barreno (PB) el más utilizado para medir la Ks. Sin embargo, es te método requiere de la presencia de un nivel freático, situación que suel e ser estacional en los suelos de nuestro país. De ahí la necesidad de buscar metodologías alternativas al Pozo Barreno. Se realizaron mediciones de Ks en un suelo de textura fina s obre un sustrato de gravas y piedras mediante tres metodologías a fin de comparar los result ados en este tipo de suelos. Se utilizaron dos métodos de campo, el pozo barr eno (PB) y el cilindro infiltrómetro (CI), y un método de laboratorio, el permeám etro de carga constante (PCC). Se realizaron mediciones por horizontes con los métodos del CI y el PCC, las cuales fueron comparadas. Las mediciones por horizontes fueron ponderadas a un valor de Ks representativo del perfil con el fin de compar arlas con las mediciones realizadas mediante el PB. El PB entregó los valores de Ks más altos, se guido por el CI con valores muy similares. El PCC entregó valores con un orden de magnitud de diferencia con las otras metodologías. La menor variabilidad de la s repeticiones las entregó el método del CI y la mayor variabilidad el PCC. Debido a la alta variabilidad y la diferencia en la magnitud de los valores de Ks entregados por el PCC, no se recomienda su utilización en suelos con características similares al estudiado. Los métodos del PB y el CI presentaron coefic ientes de variación bajos con respecto a la literatura, lo que junto con la similitud en los valores de Ks entregados, permiten recomendar la utilización de ambos métodos en suelos con características similares al estudiado. Estos métodos son complementarios, ya que el PB requiere de la presencia de un nivel freático, mientras que el CI de la ausencia de este.
376

Utilização de técnicas de otimização em redes de abastecimento de água

Pires, Rubem 12 1900 (has links)
Submitted by Fatima Fonseca (fatima.fonseca@sibi.ufrj.br) on 2017-10-09T12:57:06Z No. of bitstreams: 1 152008.pdf: 2034259 bytes, checksum: 1ae35eeced2e0b32e060a49251b35969 (MD5) / Made available in DSpace on 2017-10-09T12:57:06Z (GMT). No. of bitstreams: 1 152008.pdf: 2034259 bytes, checksum: 1ae35eeced2e0b32e060a49251b35969 (MD5) Previous issue date: 1979-12 / O objetivo deste trabalho foi otimizar os subsistemas de adução e de distribuição num sistema de abastecimento de água. No subsistema de distribuição foram consideradas redes de distribuição ramificadas e redes de distribuição em malhas. Foram utilizados, de acordo com o modelo selecionado, modelos matemáticos de otimização, programação linear e/ou simulação. Para cada sistema isolado, foram analisadas as metodologias tradicionalmente utilizadas e as propostas pelos modelos estudados, seguindo-se de aplicações em exemplos considerados. As aplicações das metodologias apresentadas, foram realizadas nos projetos de abastecimento de água das cidades de Pedras e Igarapé Mirim, no Estado do Pará. Os resultados obtidos são apresentados e discutidos detalhadamente. / The objective of this study was to analize the optimization tecniques for the main line and the distribution network of an urban water supply system. In the distribution subsystem, it was considered a branched network and a closed-loop network. According to the selected model, it was used mathematical optimization (Calculus, linear programming) or simulation. For each system, the traditional method were analyzed and the proposed method were also applied and the results were compared. The application of the methodologies were for the projected systems of Ponta de Pedras and Igarapé-Mirim in state of Pará, Brazil. The results obtained were discussed detailed.
377

Separação de escoamento a juzante de uma obstrução assimétrica em um tubo

Fleury Junior, Plínio 09 1900 (has links)
Submitted by maria angelica Varella (angelica@sibi.ufrj.br) on 2017-12-14T13:55:38Z No. of bitstreams: 1 146554.pdf: 4680162 bytes, checksum: 6babde90328908593d96227537429f17 (MD5) / Made available in DSpace on 2017-12-14T13:55:38Z (GMT). No. of bitstreams: 1 146554.pdf: 4680162 bytes, checksum: 6babde90328908593d96227537429f17 (MD5) Previous issue date: 1967-09 / CAPES / Estuda o campo de pressões nas regiões de separação, religação e redesenvolvimento, de um escoamento a juzante de uma obstrução em um tubo. A obstrução foi realizada pelo fechamento parcial da seção transversal da entrada do tubo, tal que a área aberta na seção de entrada tinha a forma de segmento circular. As experiências foram realizadas aspirando-se ar através de um tubo de latão de 7/8 polegadas de diâmetro interno, e com 130 diâmetros de comprimento. Foram conseguidas medidas de pressões estáticas por meio de dois conjuntos de tomadas nas paredes, distribuídas ao longo do tubo e localizados a 180 ºC um conjunto do outro. Um conjunto de tomadas foi localizado no lado oposto. Foram desenvolvidos para valores de h/D = 1,00, 0,75, 0,50 e 0,25, onde h é a flexa do segmento circular e D é o diâmetro interno do tubo. O número de Reynolds cobriu o campo de 7,75 x 10 4 e 1,40 x 10 4. A distribuição das pressões, em relação ao ambiente e normalizadas pela pressão dinâmica local foi lançada como uma função da coordenada axial, para todos os casos estudados. Os gráficos mostram claramente os processos de separação, religação e redesenvolvimento. A contração do escoamento, devido à separação, causa uma queda de pressão, a qual, em termos de pressão dinâmica, vai de 1,40 a 56,00 dependendo da gradação da separação. A localização da vena contracta move-se para juzante conforme cresce a separação indo, aproximadamente, de 1/2 a 2 diâmetros. O valor porcentual da recuperação da pressão diminui e ponto de religação move-se para juzante, conforme a separação se torna maior. A assimetria no campo de pressões dei.rido à obstrução assimétrica persiste somente, até o ponto de religação, uma distância relativamente curta da entrada. Por exemplo, para a maior separação estudada aqui, as pressões resultantes dos dois conjuntos de tomadas são essencialmente idênticas após 7 diâmetros a par- tir da entrada. É notável o comportamento dessas diferenças até desaparecerem, pois mudam de sentido no espaço entre a entrada e o ponto de religação. Foram avaliados dos dados experimentais, os coeficientes de atrito, para a região completamente redesenvolvida (depois de 30 diâmetros), e estão em excelente concordância com os valores aceitos na literatura. Foram tabelados os coeficientes de perda caracterizando a separação.
378

Estimativa da infiltração de água no solo a partir de pedofunções / Estimating soil water infiltration based on pedofunctions

Fiorin, Tatiana Tasquetto 06 March 2008 (has links)
Knowledge on soil water infiltration is essential for the solution of problems concerning irrigation and drainage areas and those related to water and soil conservation research. In that regard, the aim of this paper was to model water infiltration rate and hydraulic conductivity in saturated soil by means of pedotransfer functions for soils of various physical characteristics in 16 sites in Rio Grande do Sul and 04 sites in Uruguay. For each site, the following variables were determined: water infiltration rate, density (soil and particle), soil porosity (macro, micro and total), texture (clay, silt and sand), initial soil moisture content, saturation and water content at 1, 6, 10, 100, 500, 1500 KPa, and hydraulic conductivity (which was measured in seven sites only). Experimental water infiltration rate was obtained by use of the Double-ring infiltrometer and data were adjusted with Kostiakov s and Horton s model. Artificial rainfalls were applied by using a simulator with stationary and oscillating nozzles. Six plots measuring 0,5 m2 were delimited by galvanized steel boards inserted into the soil. Each board was equipped with a gutter at the lower part to collect runoff water (measured at 5-minute intervals). Smith s mathematical model as modified by Cabeda was used to describe infiltration rate. Experimental hydraulic conductivity in saturated soil was carried out by using Guelph s parameter. Kostiakov1s, Horton s and Smith s parameters were adjusted by means of multivariate equations. In comparison to Kostiakov s, Horton s model resulted in overestimation of soil water capacity. For Argissolo 01 and 02 and Chernossolo, cross-comparison between Kostiakov and Horton s model and Smith s model revealed overestimation of water infiltration rate by use of Kostiakov and Horton s model. While for Latossolo 12, Neossolo, and Vertissolo 01, water infiltration values were underestimated. In determining multivariate equations for the estimation of Kostiakov and Horton s models parameters, physical-hydraulic variables adopted were density (soil and particle), soil porosity (macro, micro and total), texture (clay, silt and sand), initial soil moisture content and saturation, and water content at 1, 6, 10, 100, 500, 1500 KPa. Such equations performed suitably for all the soils investigated. The pedofunction originated from the correlation between water infiltration rate obtained by means of Kostiakov and Horton s pedofunctions and water infiltration rate obtained by means of Smith s model can adequately predict water infiltration rate as estimated by Smith s model. Obtaining pedofunction equations by use of multivariate equations for estimating hydraulic conductivity in saturated soil solo by Guelph s model is suitable for estimating the model parameters. / O conhecimento da infiltração da água no solo é fundamental para a solução de problemas relativos as áreas de irrigação e drenagem e conservação da água e do solo. Deste modo, o objetivo desse trabalho foi modelar a taxa de infiltração de água no solo e a condutividade hidráulica em solo saturado através de funções de pedotransferência, para solos com diferentes características físicas, em 16 diferentes locais no Rio Grande do Sul e quatro no Uruguai. Em cada local foi determinada a taxa de infiltração de água no solo, densidade (do solo e de partícula), porosidade do solo (macro, micro e total), textura (argila, silte e areia), conteúdo volumétrico de água inicial e na saturação do solo e conteúdo volumétrico de água nas tensões de 1, 6, 10, 100, 500, 1500 KPa e a condutividade hidráulica (determinada apenas em sete locais). A taxa de infiltração de água no solo a campo foi obtida por meio do infiltrômetro dos duplos anéis concêntricos e os dados foram ajustados pelo modelo de Kostiakov e Horton. Chuvas artificiais foram aplicadas utilizando-se um simulador estacionário de bicos múltiplos e oscilantes. Seis parcelas de 0,5 m2 foram delimitadas por chapas metálicas galvanizadas cravadas no solo, contendo na parte inferior uma calha coletora, para recolher a água de escoamento superficial (mensurado em intervalos de cinco minutos). O modelo matemático usado para descrever a taxa de infiltração foi o de Smith modificado por Cabeda. A determinação da condutividade hidráulica em solo saturado a campo foi realizada utilizando o permeâmetro de Guelph. Os parâmetros dos modelos Kostiakov, Horton e Smith foram ajustados através de equações multivariadas. Observou-se que a capacidade de infiltração de água no solo estimada pelo modelo de Horton apresentou uma superestimava, em relação ao modelo estimado de Kostiakov. Ao comparar os modelos de Kostiakov e Horton com o de Smith, observa-se uma superestimativa da taxa de infiltração de água no solo, utilizando o modelo de Kostiakov e o de Horton, para o Argissolo 01 e 02 e Chernossolo. Para o Latossolo 12, Neossolo, e Vertissolo 01, houve uma subestimativa nos valores de infiltração de água. Na determinação das equações multivariadas, para estimativa dos parâmetros dos modelos de Kostiakov e Horton, as variáveis físico-hidrícas utilizadas foram densidade (do solo e de partícula), porosidade do solo (macro, micro e total), textura (argila, silte e areia), conteúdo volumétrico de água inicial e na saturação do solo e conteúdo volumétrico de água nas tensões de 1, 6, 10, 100, 500, 1500 KPa. Estas equações apresentaram desempenho satisfatório em todos os solos estudados. A pedofunção originada da correlação entre a taxa de infiltração de água no solo obtida através das pedofunções de Kostiakov e Horton, com a taxa de infiltração de água no solo obtida pelo modelo de Smith, prevê satisfatoriamente a taxa de infiltração de água no solo estimada pelo modelo de Smith. A obtenção das equações de pedofunções, através de equações multivariadas, para estimativa a condutividade hidráulica em solo saturado pelo modelo de Guelph, pode ser utilizada satisfatoriamente para estimativa dos parâmetros do modelo.
379

Variabilidade da condutividade hidráulica e de formas do nitrogênio em sistemas alagados construídos de escoamento horizontal subsuperficial / Variability of hydraulic conductivity and forms of nitrogen in constructed wetland systems of horizontal subsurface flow

Ferres, Gheila Corrêa 16 February 2012 (has links)
Made available in DSpace on 2015-03-26T13:23:42Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2319739 bytes, checksum: 8d787f013c376eae45142c8b694720cf (MD5) Previous issue date: 2012-02-16 / Fundação de Amparo a Pesquisa do Estado de Minas Gerais / Constructed wetland systems of horizontal subsurface flow (CW-SSHF) are systems used in wastewater treatment. The objective of the present study was to assess possible changes in hydrodynamic conditions, through analysis of hydraulic conductivity and forms of nitrogen in CW-SSHF. In this study, six CW-SSHF were installed with dimensions of 0.6 m x 0.5 m x 2.0 m in height, width and length, respectively, with no bottom slope, filled with pea gravel and maintained in a greenhouse for the treatment of swine wastewater (ARS). CW-SSHF1 and CW-SSHF4 were not cultivated with any plant species (control), while CW-SSHF2 and CW-SSHF5 were planted with Tifton 85 (Cynodon spp.), and CW-SSHF3 and CW-SSHF6 were planted with Alligator weed (Alternanthera philoxeroides). During the experimental period six samples were collected of the influent (ARSA) and effluent (ARSE) of each CW-SSHF. Five hydraulic conductivity tests were also conducted along the length of the systems as a function of time, in order to evaluate the effects of vegetation, position and time on this variable. For comparison, hydraulic conductivity was determined in one CW-SSHF filled with pea gravel and submitted to flow of clean water. In all CW-SSHF an average organic loading rate of 411 kg ha-1 d-1 was applied with average flow of 0.069 m3 d-1, where the hydraulic retention time was equal to 3.6 d. The monitoring period was 63 days. At the end of the experiment, the plants were cut and the dry material yield was determined. The analysis of variance of hydraulic conductivity showed that only the interaction of position and vegetation effects was significant at the level of 10% probability. Hydraulic conductivity values in the thirds ranged from 1,392 m d-1 to 2,834 m d-1, where the differences between thirds of the CW-SSHF primarily occurred between the planted and non-planted systems by the Tukey test level 10% probability. All CW-SSHF presented average hydraulic conductivity values less than those obtained the system with clean water, which was 2680 m d-1. Dry matter yields in the different thirds of the bed ranged from 6.0 to 9.8 t ha-1 in the CW-SSHF planted with Tifton 85 and Alligator weed during the growth period of 60 days. The removal efficiency of total nitrogen (NT) and ammonium (N-NH4+) was considered low, ranging from 8 to 15% and 3 to 13%, respectively. Nitrate (N-NO3-) removal efficiency ranged from 45 to 53%. In all cases, the cultivated CW-SSHF showed higher efficiency for nitrogen removal. The CW-SSHF did not provide conditions which favored the occurrence of nitrification/denitrification. / Os sistemas alagados construídos de escoamento horizontal subsuperficial (SACs-EHSS) são sistemas utilizados no tratamento de águas residuárias. Com a realização deste estudo, objetivou-se avaliar possíveis alterações nas condições hidrodinâmicas, via análise da condutividade hidráulica, e nas formas do nitrogênio em SACs-EHSS. Para possibilitar este estudo, foram instalados seis SACs-EHSS, nas dimensões de 0,6 m x 0,5 m x 2,0 m de altura, largura e comprimento, respectivamente, sem declividade de fundo, preenchidos com brita zero e mantidos em casa de vegetação, para se efetuar o tratamento de água residuária de suinocultura (ARS). Os SAC-EHSS1 e SAC-EHSS4 não foram cultivados com qualquer espécie vegetal (controle), os SAC-EHSS2 e SAC-EHSS5 foram cultivados com capim tifton 85 (Cynodon spp.) e os SAC-EHSS-EHSS3 e SAC-EHSS6 cultivados com alternanthera (Alternanthera philoxeroides). Durante o período experimental foram coletadas seis amostras do afluente (ARSA) e do efluente (ARSE) de cada SAC-EHSS. Realizaram-se, também, cinco testes de condutividade hidráulica, ao longo do sistema e ao longo do tempo, a fim de se avaliar os efeitos da vegetação, posição e tempo sobre esta variável. A título de comparação, determinou-se a condutividade hidráulica em um SACs-EHSS preenchido com brita e submetido a escoamento de água limpa. Em todos os SACs-EHSS foi aplicada, em média, uma taxa de carregamento orgânico de 411 kg ha-1 d-1 e vazão média de 0,069 m3 d-1, sendo o tempo de detenção hidráulica igual a 3,6 d. O período de monitoramento foi de 63 dias. Ao final do experimento, foi feito um corte das plantas e determinada a produtividade de matéria seca. A análise de variância dos dados de condutividade hidráulica demonstrou que apenas a interação dos efeitos posição e vegetação foi significativa, em nível de 10 % de probabilidade. Os valores de condutividade hidráulica para os terços variaram de 1.392 m d-1 a 2.834 m d-1, sendo que as diferenças entre os terços dos SACs-EHSS ocorreram, basicamente, entre os vegetados e não vegetados, pelo teste Tukey, em nível de 10% de probabilidade. Todos os SACs-EHSS apresentaram condutividade hidráulica média inferior à obtida na brita limpa, que foi de 2.680 m d-1. A produtividade de matéria seca nos terços do leito variou de 6,0 a 9,8 t ha-1, nos SACs-EHSS cultivados com tifton 85 e alternanthera, em um período de 60 dias de cultivo. A eficiência na remoção de nitrogênio total (NT) e amônio (N-NH4+) foram consideradas baixas, variando de 8 a 15% e 3 a 13%, respectivamente. A eficiência de remoção de nitrato (N-NO3-) variou de 45 a 53%. Em todos os casos, os SACs-EHSS cultivados apresentaram maior eficiência na remoção de nitrogênio. Os SACs-EHSS não proporcionaram condições que favorecessem a ocorrência de nitrificação/desnitrificação.
380

Aplicações de técnicas de controle Fuzzy em sistemas de abastecimento de água visando melhoria no rendimento energético e hidráulico

Camboim, Wil Lavor Lucena 30 October 2012 (has links)
Made available in DSpace on 2015-05-08T14:59:49Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2211091 bytes, checksum: a9fb48cc1e0172afdcc7b126c8668952 (MD5) Previous issue date: 2012-10-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This paper presents the development of a fuzzy system, in LabviewTM environment for the pressure control of distribution of water through two sets of motor-driven pump drives. The drive motor-pump sets is accomplished with three-phase induction motors with variable speed in order to save electricity and water. For this we developed an experimental bench instrumentalized emulating a real supply system. The proposed system consists of motor-pump assemblies in parallel due to varying flow demand required. These two charging system to generate a large number of possibilities mode associations of the motor-pump assemblies with different rotational speeds. The Fuzzy controller identifies the best option for the energy consumption and system performance and makes the decision alluding to the state of the engines (on, off or partial rotation speed). This entire process is performed under the condition of meeting the demand flow system, and maintain constant pressure at a predetermined value. To validate the controller were performed several tests that proved the efficiency of the control system and its influence on the consumption of electricity and water. It can be concluded that the performance of the fuzzy system has proved satisfactory, and can be deployed with relative ease other water distribution systems with similar characteristics. The results brought, besides the reduction of energy consumption, conservation of pressure at constant levels, increasing the degree of system reliability and the probable reduction of maintenance costs. / Neste trabalho apresenta-se o desenvolvimento de um sistema Fuzzy, em ambiente LabviewTM, para o controle de pressão de redes de distribuição de água, por meio de dois conjuntos motor-bomba acionados por conversores de frequência. O acionamento dos conjuntos motor-bomba é realizado com motores de indução trifásico com velocidade de rotação variável visando a economia de energia elétrica e água. Para isso foi desenvolvido uma bancada experimental instrumentalizada emulando um sistema de abastecimento real. O sistema proposto é constituído de conjuntos motor-bomba em paralelo, devido à variação de demanda de vazão requerida. Essas duas imposições geram ao sistema um grande número de possibilidades do modo de associações dos conjuntos motor-bomba, com velocidades de rotação diferentes. O controlador Fuzzy identifica a melhor opção, referente ao consumo energético e rendimento do sistema e toma a decisão alusiva ao estado dos motores (ligado, desligado ou com velocidade de rotação parcial). Todo esse processo é realizado na condição de atender a demanda de vazão do sistema, além de manter a pressão constante em um valor pré-determinado. Para validação do controlador foram realizados diversos testes que comprovaram a eficiência do sistema de controle e a influência desse no consumo de energia elétrica e água. Pode-se concluir que o desempenho do sistema Fuzzy se mostrou satisfatório, podendo ser implantado com relativa facilidade em outros sistemas de distribuição de água com características similares. Os resultados trouxeram, além da redução do consumo energético, a conservação da pressão em níveis constantes, o aumento do grau de confiabilidade do sistema e a provável redução dos custos com manutenção.

Page generated in 0.056 seconds