• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 6
  • 6
  • 6
  • 6
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Eficiência energética de estações de bombeamento : estudo de caso do campus do vale da Universidade Federal do Rio Grande do Sul

Tonial, Fernanda de Carli January 2014 (has links)
Tendo como motivação os altos gastos energéticos em estações de recalque de água, esta pesquisa está centrada na avaliação hidroenergética de estações de bombeamento que não utilizaram o conceito de eficiência energética como premissa na sua concepção. Para tanto, foi desenvolvida a avaliação da elevatória que abastece o anel viário do Campus do Vale da Universidade Federal do Rio Grande do Sul. O desenvolvimento do diagnóstico hidroenergético só foi possível ser realizado após a obtenção de informações documentais junto aos órgãos da Universidade; aquisição em campo de dados mecânicos, elétricos e hidráulicos como a obtenção da curva característica de consumo de água da área em estudo. Para a avaliação da estação em estudo, utilizaram-se os indicadores de desempenhos contíguos a um simulador hidráulico de redes de abastecimento. No simulador, foram desenvolvidos quatro diferentes cenários: Cenário I, buscou-se reproduzir as grandezas obtidas em campo visando validar o modelo gerado; Cenário II permitiu fazer um diagnóstico do comportamento e do consumo de energia na estação em estudo frente a novos valores de demanda de água; No Cenário III, foram propostas novas formas de se realizar o bombeamento de água na demanda atual e, na de final de plano, objetivando melhorar o desempenho e reduzir o consumo e o custo energético sem ser necessária nenhuma intervenção física no sistema existente; e no Cenário IV, foram sugeridas alterações de componentes físicos do sistema (adutora, grupo motobomba e implantação de sistema de acionamento e monitoramento) para possibilitar a implantação de leis guias de bombeamento mais complexas. A identificação da curva de consumo de água foi um dos principais resultados obtidos nesta pesquisa, pois retratou as diferentes sazonalidades que a área de estudo está sujeita, durante um ano inteiro. Os cenários criados foram modelados considerando a curva de consumo anual. Pelos valores encontrados é possível afirmar que o custo final para cada 1000 m³ bombeados diminui em 33% do Cenário I para o Cenário III na tarifa Horo-Sazonal Verde, que é a tarifa mais aconselhável para o sistema em estudo. Porém mesmo tendo-se economizado com o custo da energia elétrica o Cenário III apresentou valores de indicadores de desempenho mais distantes do ideal teórico. Então, entende-se que a melhora dos indicadores de desempenho analisados, por serem índices de desempenho técnicos e não financeiros, não repercute necessariamente em economicidade para o sistema. O Cenário IV foi o que apresentou os melhores valores tanto em termos de consumo de energia, quanto financeiros e nos índices de desempenho. A redução no consumo de energia elétrica, neste cenário, foi da ordem de 60%, o custo final para cada 1000 m³ bombeados diminui em 70% e, as melhoras dos indicadores de desempenho foram de até 60%. Porém mesmo assim dependendo do material a ser utilizado na implantação da nova adutora pode não haver o retorno do investimento inicial. Esta pesquisa salientou a importância da aplicação dos índices de desempenho atrelados à simulação hidráulica e a análise econômica para o desenvolvimento de diagnósticos hidroenergéticos em estações de recalque. / Having as a motivation the high energy costs of water booster stations , this research is focused on the evaluation of hydropower pumping stations that did not use the concept of energy efficiency as a basis in its design . Therefore, the evaluation of the station that supplies the Beltway off the Valley Campus of the Federal University of Rio Grande do Sul was developed. The development of the hydropower diagnosis was only possible to be done after obtaining documentary information from the organs of the University; acquisition in the field of mechanical, electrical and hydraulic data and obtaining the characteristic curve of water consumption of the study area. For the evaluation of the station under study, we used the indicators contiguous to a hydraulic supply network simulator performance. In the simulator , four different scenarios were developed: The Scenario I sought to reproduce the magnitudes obtained in the field aiming to validate the model generated; Scenario II allowed to diagnose the behavior and the energy consumption in the study station in view of the new values of water demand; in Scenario III a, new way of performing the pumping of water from current demand was proposed and that, in the final plan , aiming to improve performance and reduce energy consumption and costs without requiring any physical intervention on the existing system. In Scenario IV , changes in physical components of the system ( pipeline , pump unit and drive system deployment and monitoring) that enabled the implementation of more complex laws guiding, pumping were suggested. One of the main results obtained in this study was the identification of the consumption of water curve, which portrayed the seasonality that study area is subject to for a whole year. The scenarios created were modeled considering the curve of annual consumption. From the values found we can say that the final cost per 1000 m³ pumped decreases by 33 % from Scenario I to Scenario III - using Horo-Sazonal Verde tariff, which is the most desirable for the system under study. But even having saved in the cost of electricity, Scenario III showed values of the performance indicators far from the theoretical ideal. It is understood that the improvement of the performance indicators analyzed, being indices of technical and not of financial performance, do not necessarily reflect an operational economy for the system . Scenario IV showed the best values in terms of energy consumption, financial and performance ratios. The reduction in electricity consumption in this scenario was approximately 60 %, the final cost per 1000 m³ pumped decreases by 70 %, and the improvement of the performance indicators were up 60 %. However, depending on the material used in the implementation of the new pipeline there can be no return on initial investment. This research emphasized the importance of the application of performance indicators linked to hydraulic simulation and economic analysis for the development of hydropower diagnostics booster stations.
2

Eficiência energética de estações de bombeamento : estudo de caso do campus do vale da Universidade Federal do Rio Grande do Sul

Tonial, Fernanda de Carli January 2014 (has links)
Tendo como motivação os altos gastos energéticos em estações de recalque de água, esta pesquisa está centrada na avaliação hidroenergética de estações de bombeamento que não utilizaram o conceito de eficiência energética como premissa na sua concepção. Para tanto, foi desenvolvida a avaliação da elevatória que abastece o anel viário do Campus do Vale da Universidade Federal do Rio Grande do Sul. O desenvolvimento do diagnóstico hidroenergético só foi possível ser realizado após a obtenção de informações documentais junto aos órgãos da Universidade; aquisição em campo de dados mecânicos, elétricos e hidráulicos como a obtenção da curva característica de consumo de água da área em estudo. Para a avaliação da estação em estudo, utilizaram-se os indicadores de desempenhos contíguos a um simulador hidráulico de redes de abastecimento. No simulador, foram desenvolvidos quatro diferentes cenários: Cenário I, buscou-se reproduzir as grandezas obtidas em campo visando validar o modelo gerado; Cenário II permitiu fazer um diagnóstico do comportamento e do consumo de energia na estação em estudo frente a novos valores de demanda de água; No Cenário III, foram propostas novas formas de se realizar o bombeamento de água na demanda atual e, na de final de plano, objetivando melhorar o desempenho e reduzir o consumo e o custo energético sem ser necessária nenhuma intervenção física no sistema existente; e no Cenário IV, foram sugeridas alterações de componentes físicos do sistema (adutora, grupo motobomba e implantação de sistema de acionamento e monitoramento) para possibilitar a implantação de leis guias de bombeamento mais complexas. A identificação da curva de consumo de água foi um dos principais resultados obtidos nesta pesquisa, pois retratou as diferentes sazonalidades que a área de estudo está sujeita, durante um ano inteiro. Os cenários criados foram modelados considerando a curva de consumo anual. Pelos valores encontrados é possível afirmar que o custo final para cada 1000 m³ bombeados diminui em 33% do Cenário I para o Cenário III na tarifa Horo-Sazonal Verde, que é a tarifa mais aconselhável para o sistema em estudo. Porém mesmo tendo-se economizado com o custo da energia elétrica o Cenário III apresentou valores de indicadores de desempenho mais distantes do ideal teórico. Então, entende-se que a melhora dos indicadores de desempenho analisados, por serem índices de desempenho técnicos e não financeiros, não repercute necessariamente em economicidade para o sistema. O Cenário IV foi o que apresentou os melhores valores tanto em termos de consumo de energia, quanto financeiros e nos índices de desempenho. A redução no consumo de energia elétrica, neste cenário, foi da ordem de 60%, o custo final para cada 1000 m³ bombeados diminui em 70% e, as melhoras dos indicadores de desempenho foram de até 60%. Porém mesmo assim dependendo do material a ser utilizado na implantação da nova adutora pode não haver o retorno do investimento inicial. Esta pesquisa salientou a importância da aplicação dos índices de desempenho atrelados à simulação hidráulica e a análise econômica para o desenvolvimento de diagnósticos hidroenergéticos em estações de recalque. / Having as a motivation the high energy costs of water booster stations , this research is focused on the evaluation of hydropower pumping stations that did not use the concept of energy efficiency as a basis in its design . Therefore, the evaluation of the station that supplies the Beltway off the Valley Campus of the Federal University of Rio Grande do Sul was developed. The development of the hydropower diagnosis was only possible to be done after obtaining documentary information from the organs of the University; acquisition in the field of mechanical, electrical and hydraulic data and obtaining the characteristic curve of water consumption of the study area. For the evaluation of the station under study, we used the indicators contiguous to a hydraulic supply network simulator performance. In the simulator , four different scenarios were developed: The Scenario I sought to reproduce the magnitudes obtained in the field aiming to validate the model generated; Scenario II allowed to diagnose the behavior and the energy consumption in the study station in view of the new values of water demand; in Scenario III a, new way of performing the pumping of water from current demand was proposed and that, in the final plan , aiming to improve performance and reduce energy consumption and costs without requiring any physical intervention on the existing system. In Scenario IV , changes in physical components of the system ( pipeline , pump unit and drive system deployment and monitoring) that enabled the implementation of more complex laws guiding, pumping were suggested. One of the main results obtained in this study was the identification of the consumption of water curve, which portrayed the seasonality that study area is subject to for a whole year. The scenarios created were modeled considering the curve of annual consumption. From the values found we can say that the final cost per 1000 m³ pumped decreases by 33 % from Scenario I to Scenario III - using Horo-Sazonal Verde tariff, which is the most desirable for the system under study. But even having saved in the cost of electricity, Scenario III showed values of the performance indicators far from the theoretical ideal. It is understood that the improvement of the performance indicators analyzed, being indices of technical and not of financial performance, do not necessarily reflect an operational economy for the system . Scenario IV showed the best values in terms of energy consumption, financial and performance ratios. The reduction in electricity consumption in this scenario was approximately 60 %, the final cost per 1000 m³ pumped decreases by 70 %, and the improvement of the performance indicators were up 60 %. However, depending on the material used in the implementation of the new pipeline there can be no return on initial investment. This research emphasized the importance of the application of performance indicators linked to hydraulic simulation and economic analysis for the development of hydropower diagnostics booster stations.
3

Eficiência energética de estações de bombeamento : estudo de caso do campus do vale da Universidade Federal do Rio Grande do Sul

Tonial, Fernanda de Carli January 2014 (has links)
Tendo como motivação os altos gastos energéticos em estações de recalque de água, esta pesquisa está centrada na avaliação hidroenergética de estações de bombeamento que não utilizaram o conceito de eficiência energética como premissa na sua concepção. Para tanto, foi desenvolvida a avaliação da elevatória que abastece o anel viário do Campus do Vale da Universidade Federal do Rio Grande do Sul. O desenvolvimento do diagnóstico hidroenergético só foi possível ser realizado após a obtenção de informações documentais junto aos órgãos da Universidade; aquisição em campo de dados mecânicos, elétricos e hidráulicos como a obtenção da curva característica de consumo de água da área em estudo. Para a avaliação da estação em estudo, utilizaram-se os indicadores de desempenhos contíguos a um simulador hidráulico de redes de abastecimento. No simulador, foram desenvolvidos quatro diferentes cenários: Cenário I, buscou-se reproduzir as grandezas obtidas em campo visando validar o modelo gerado; Cenário II permitiu fazer um diagnóstico do comportamento e do consumo de energia na estação em estudo frente a novos valores de demanda de água; No Cenário III, foram propostas novas formas de se realizar o bombeamento de água na demanda atual e, na de final de plano, objetivando melhorar o desempenho e reduzir o consumo e o custo energético sem ser necessária nenhuma intervenção física no sistema existente; e no Cenário IV, foram sugeridas alterações de componentes físicos do sistema (adutora, grupo motobomba e implantação de sistema de acionamento e monitoramento) para possibilitar a implantação de leis guias de bombeamento mais complexas. A identificação da curva de consumo de água foi um dos principais resultados obtidos nesta pesquisa, pois retratou as diferentes sazonalidades que a área de estudo está sujeita, durante um ano inteiro. Os cenários criados foram modelados considerando a curva de consumo anual. Pelos valores encontrados é possível afirmar que o custo final para cada 1000 m³ bombeados diminui em 33% do Cenário I para o Cenário III na tarifa Horo-Sazonal Verde, que é a tarifa mais aconselhável para o sistema em estudo. Porém mesmo tendo-se economizado com o custo da energia elétrica o Cenário III apresentou valores de indicadores de desempenho mais distantes do ideal teórico. Então, entende-se que a melhora dos indicadores de desempenho analisados, por serem índices de desempenho técnicos e não financeiros, não repercute necessariamente em economicidade para o sistema. O Cenário IV foi o que apresentou os melhores valores tanto em termos de consumo de energia, quanto financeiros e nos índices de desempenho. A redução no consumo de energia elétrica, neste cenário, foi da ordem de 60%, o custo final para cada 1000 m³ bombeados diminui em 70% e, as melhoras dos indicadores de desempenho foram de até 60%. Porém mesmo assim dependendo do material a ser utilizado na implantação da nova adutora pode não haver o retorno do investimento inicial. Esta pesquisa salientou a importância da aplicação dos índices de desempenho atrelados à simulação hidráulica e a análise econômica para o desenvolvimento de diagnósticos hidroenergéticos em estações de recalque. / Having as a motivation the high energy costs of water booster stations , this research is focused on the evaluation of hydropower pumping stations that did not use the concept of energy efficiency as a basis in its design . Therefore, the evaluation of the station that supplies the Beltway off the Valley Campus of the Federal University of Rio Grande do Sul was developed. The development of the hydropower diagnosis was only possible to be done after obtaining documentary information from the organs of the University; acquisition in the field of mechanical, electrical and hydraulic data and obtaining the characteristic curve of water consumption of the study area. For the evaluation of the station under study, we used the indicators contiguous to a hydraulic supply network simulator performance. In the simulator , four different scenarios were developed: The Scenario I sought to reproduce the magnitudes obtained in the field aiming to validate the model generated; Scenario II allowed to diagnose the behavior and the energy consumption in the study station in view of the new values of water demand; in Scenario III a, new way of performing the pumping of water from current demand was proposed and that, in the final plan , aiming to improve performance and reduce energy consumption and costs without requiring any physical intervention on the existing system. In Scenario IV , changes in physical components of the system ( pipeline , pump unit and drive system deployment and monitoring) that enabled the implementation of more complex laws guiding, pumping were suggested. One of the main results obtained in this study was the identification of the consumption of water curve, which portrayed the seasonality that study area is subject to for a whole year. The scenarios created were modeled considering the curve of annual consumption. From the values found we can say that the final cost per 1000 m³ pumped decreases by 33 % from Scenario I to Scenario III - using Horo-Sazonal Verde tariff, which is the most desirable for the system under study. But even having saved in the cost of electricity, Scenario III showed values of the performance indicators far from the theoretical ideal. It is understood that the improvement of the performance indicators analyzed, being indices of technical and not of financial performance, do not necessarily reflect an operational economy for the system . Scenario IV showed the best values in terms of energy consumption, financial and performance ratios. The reduction in electricity consumption in this scenario was approximately 60 %, the final cost per 1000 m³ pumped decreases by 70 %, and the improvement of the performance indicators were up 60 %. However, depending on the material used in the implementation of the new pipeline there can be no return on initial investment. This research emphasized the importance of the application of performance indicators linked to hydraulic simulation and economic analysis for the development of hydropower diagnostics booster stations.
4

A influência do assoreamento na geração de energia hidrelétrica: estudo de caso na Usina de Três Irmãos - SP / The influence of silting in the generation of hydroelectric energy: case study at Três Irmãos power plant - SP

Miranda, Renato Billia de 23 February 2011 (has links)
Com a crescente demanda de energia elétrica há a necessidade da criação de novas fontes de energia e otimização das fontes já existentes. No caso de países que apresentam uma matriz energética predominantemente hidrelétrica como o Brasil, com grandes usinas e reservatórios, os estudos sedimentológicos e os levantamentos batimétricos se apresentam como importantes ferramentas para melhorar o planejamento e o gerenciamento dos recursos hídricos e energéticos. Atualmente, muitos reservatórios hidrelétricos operam com dados defasados devido, principalmente, ao contínuo processo de assoreamento dos reservatórios. Este fato faz com que as políticas de gestão e operação destes reservatórios sejam realizadas a partir de dados diferentes dos encontrados na realidade. Neste contexto, a dissertação apresenta um estudo de caso no Reservatório de Três Irmãos (SP), onde foi realizado um levantamento batimétrico em 2008, e a partir da comparação dos dados obtidos neste levantamento com os dados fornecidos pela concessionária de energia, de 1975, foi possível estimar as perdas de volume total, útil e morto do reservatório que correspondem a 14,3%, 14,5% e 14,2%, respectivamente. A partir da observação destas modificações nos dados operacionais do reservatório em estudo, foi realizada a simulação da operação do reservatório e da usina hidrelétrica por meio do software AcquaNet, com a intenção de analisar qual a interferência do assoreamento do reservatório na geração de energia elétrica, durante o período de 1993 a 2008. Com os resultados foi constatado que a diminuição do volume útil do reservatório (devido ao assoreamento) acarretou na redução da energia gerada pela usina durante o período analisado. Também foi possível estimar as perdas financeiras da concessionária de energia com a redução da produção energética. Foram sugeridas, ainda, algumas medidas preventivas e corretivas para a redução do processo de assoreamento do reservatório em estudo. / With the increasing demand of energy, it is necessary to create new sources and optimize the ones that already exist. In the case of countries that present an energy matrix predominantly hydroelectric such as Brazil, where there are huge power plants and reservoirs, the studies on sedimentation and beating surveys are presented as important tools to sharpen the planning and the management of water and energy resources. Currently, most of the hydroelectric reservoirs operate in gapped data, due to, mainly, the continuing process of reservoirs silting. This makes management policies and operation of these reservoirs be performed from data that differ from the ones found in reality. In this context, this dissertation presents a case study at the Três Irmãos Reservoir (SP), where a beating survey was carried out in 2008, and, from the comparison of the data revealed in that survey with the data provided by the power utility in 1975, it was possible to estimate the losses of total capacity, live storage and void volume of the reservoir, which correspond to 14,3%, 14,5% e 14,2%, respectively. From the observation of these operational data modification of the reservoir under study was performed the simulate of the operation of the reservoir and hydroelectric plant with the employing of the AcquaNet software with the intention to look into the interference of silting of the reservoir in generate electricity during the period 1993 to 2008. With the results was found that the decrease in the capacity of the reservoir (due to siltation) resulted in the reduction of energy generated by the plant during the period analyzed. With this verification, it was also possible to estimate the financial losses of the power utility with the reduction of energy production. Was suggested also, some preventive and corrective measures to reduce siltation process in the reservoir under study.
5

Sistemas de bombeamento de água com velocidade de rotação variável

Kuritza, Jóice Cristini January 2017 (has links)
O consumo de energia dispendido pelos sistemas de bombeamento apresenta valores elevados e que podem onerar a operação dos sistemas de abastecimento de água realizada pelas companhias de saneamento. Assim, esta pesquisa está centrada no desenvolvimento de uma metodologia para análise da eficiência energética desses sistemas. O procedimento metodológico foi desenvolvido para uma tipologia genérica de sistema composta de dois reservatórios, inferior e superior, um conjunto motobomba e uma adutora, responsável pelo transporte de água entre eles. Foram avaliadas 96 possibilidades geométricas para esse sistema, formadas a partir da combinação de diferentes alturas geométricas, comprimentos e diâmetros da linha adutora. Ainda, foram estudados três formatos de curva, com quatro volumes de consumo diário distintos, em duas situações, início e fim de projeto. O algoritmo Shuffled Complex Evolution – SCE-UA foi empregado para obter a regra de operação otimizada do sistema de bombeamento e a função-objetivo foi formulada para representar os custos de energia para 20 anos de operação somado aos custos de instalação do sistema de bombeamento (adutora, reservatório superior e conjunto motobomba). Além disso, foram calculados índices e indicadores para facilitar o entendimento e a avaliação da eficiência energética de sistemas de bombeamento. A partir da análise dos resultados dos sistemas cuja operação foi otimizada, e dos resultados dos índices e indicadores, foram estabelecidos critérios e equações que podem ser utilizados para análise da operação, dimensionamento e eficiência energética de sistemas de bombeamento de água. Também, foi desenvolvida uma metodologia para a estimativa da energia mínima que um sistema de bombeamento pode consumir se todos os critérios de eficiência energética forem satisfeitos, ou seja, quando todas as grandezas que compõem o cálculo da energia forem determinadas a partir de critérios otimizados. Essa metodologia foi aplicada em dois cenários: projetos de sistemas de bombeamento de água e diagnóstico de sistemas de bombeamento de água existentes. Na primeira abordagem, o indicador se mostrou útil para inferir sobre consumo de energia e, inclusive, definir o diâmetro ótimo da linha adutora com maior ponderação. Já na segunda abordagem, o indicador tem potencial para ser utilizado na definição da linha de base do sistema e pode auxiliar a tomada de decisão e gestão hidroenergética desses sistemas. / The energy consumed by the pumping systems has high values and can overload the operation of the water supply systems carried out by the sanitation companies. Thus, this research is focused on the development of a methodology to analyze the energy efficiency of these systems. The methodological procedure was developed for a generic system composed of two reservoirs, upper and lower, pumping system and a pipeline, responsible for transporting water between the reservoirs. It was evaluated 96 geometric possibilities for this system, formed from the combination of different static heights, lengths and diameters of the pipeline. Also, three curve formats were studied, with four distinct daily consumption volumes, in two situations, beginning and end of the project. The Shuffled Complex Evolution (SCE-UA) algorithm was employed to obtain the optimal operating rule for the pumping system and the objective function was formulated to represent the energy costs for 20 years of operation plus the pumping system installation costs (pipeline, upper reservoir and pumping system). In addition, indexes and indicators were calculated to facilitate the understanding and evaluation of the energy efficiency of pumping systems. Based on the analysis of the results of the systems whose operation was optimized, and the results of indexes and indicators, criteria and equations were established that can be used to analyze the operation, design and energy efficiency of water pumping systems. Also, a methodology was developed to estimate the minimum energy that a pumping system can consume if all the energy efficiency criteria are met, that is, when all the quantities that compose the energy calculation are determined from optimized criteria. This methodology was applied in two scenarios: projects of water pumping systems and diagnosis of existing water pumping systems. In the first approach, the indicator was useful to infer about energy consumption and, even, to define the optimum diameter of the most heavily weighted pipeline. In the second approach, the indicator has the potential to be used in the definition of the baseline of the system and may help decision making and hydropower management of these systems.
6

Sistemas de bombeamento de água com velocidade de rotação variável

Kuritza, Jóice Cristini January 2017 (has links)
O consumo de energia dispendido pelos sistemas de bombeamento apresenta valores elevados e que podem onerar a operação dos sistemas de abastecimento de água realizada pelas companhias de saneamento. Assim, esta pesquisa está centrada no desenvolvimento de uma metodologia para análise da eficiência energética desses sistemas. O procedimento metodológico foi desenvolvido para uma tipologia genérica de sistema composta de dois reservatórios, inferior e superior, um conjunto motobomba e uma adutora, responsável pelo transporte de água entre eles. Foram avaliadas 96 possibilidades geométricas para esse sistema, formadas a partir da combinação de diferentes alturas geométricas, comprimentos e diâmetros da linha adutora. Ainda, foram estudados três formatos de curva, com quatro volumes de consumo diário distintos, em duas situações, início e fim de projeto. O algoritmo Shuffled Complex Evolution – SCE-UA foi empregado para obter a regra de operação otimizada do sistema de bombeamento e a função-objetivo foi formulada para representar os custos de energia para 20 anos de operação somado aos custos de instalação do sistema de bombeamento (adutora, reservatório superior e conjunto motobomba). Além disso, foram calculados índices e indicadores para facilitar o entendimento e a avaliação da eficiência energética de sistemas de bombeamento. A partir da análise dos resultados dos sistemas cuja operação foi otimizada, e dos resultados dos índices e indicadores, foram estabelecidos critérios e equações que podem ser utilizados para análise da operação, dimensionamento e eficiência energética de sistemas de bombeamento de água. Também, foi desenvolvida uma metodologia para a estimativa da energia mínima que um sistema de bombeamento pode consumir se todos os critérios de eficiência energética forem satisfeitos, ou seja, quando todas as grandezas que compõem o cálculo da energia forem determinadas a partir de critérios otimizados. Essa metodologia foi aplicada em dois cenários: projetos de sistemas de bombeamento de água e diagnóstico de sistemas de bombeamento de água existentes. Na primeira abordagem, o indicador se mostrou útil para inferir sobre consumo de energia e, inclusive, definir o diâmetro ótimo da linha adutora com maior ponderação. Já na segunda abordagem, o indicador tem potencial para ser utilizado na definição da linha de base do sistema e pode auxiliar a tomada de decisão e gestão hidroenergética desses sistemas. / The energy consumed by the pumping systems has high values and can overload the operation of the water supply systems carried out by the sanitation companies. Thus, this research is focused on the development of a methodology to analyze the energy efficiency of these systems. The methodological procedure was developed for a generic system composed of two reservoirs, upper and lower, pumping system and a pipeline, responsible for transporting water between the reservoirs. It was evaluated 96 geometric possibilities for this system, formed from the combination of different static heights, lengths and diameters of the pipeline. Also, three curve formats were studied, with four distinct daily consumption volumes, in two situations, beginning and end of the project. The Shuffled Complex Evolution (SCE-UA) algorithm was employed to obtain the optimal operating rule for the pumping system and the objective function was formulated to represent the energy costs for 20 years of operation plus the pumping system installation costs (pipeline, upper reservoir and pumping system). In addition, indexes and indicators were calculated to facilitate the understanding and evaluation of the energy efficiency of pumping systems. Based on the analysis of the results of the systems whose operation was optimized, and the results of indexes and indicators, criteria and equations were established that can be used to analyze the operation, design and energy efficiency of water pumping systems. Also, a methodology was developed to estimate the minimum energy that a pumping system can consume if all the energy efficiency criteria are met, that is, when all the quantities that compose the energy calculation are determined from optimized criteria. This methodology was applied in two scenarios: projects of water pumping systems and diagnosis of existing water pumping systems. In the first approach, the indicator was useful to infer about energy consumption and, even, to define the optimum diameter of the most heavily weighted pipeline. In the second approach, the indicator has the potential to be used in the definition of the baseline of the system and may help decision making and hydropower management of these systems.
7

Sistemas de bombeamento de água com velocidade de rotação variável

Kuritza, Jóice Cristini January 2017 (has links)
O consumo de energia dispendido pelos sistemas de bombeamento apresenta valores elevados e que podem onerar a operação dos sistemas de abastecimento de água realizada pelas companhias de saneamento. Assim, esta pesquisa está centrada no desenvolvimento de uma metodologia para análise da eficiência energética desses sistemas. O procedimento metodológico foi desenvolvido para uma tipologia genérica de sistema composta de dois reservatórios, inferior e superior, um conjunto motobomba e uma adutora, responsável pelo transporte de água entre eles. Foram avaliadas 96 possibilidades geométricas para esse sistema, formadas a partir da combinação de diferentes alturas geométricas, comprimentos e diâmetros da linha adutora. Ainda, foram estudados três formatos de curva, com quatro volumes de consumo diário distintos, em duas situações, início e fim de projeto. O algoritmo Shuffled Complex Evolution – SCE-UA foi empregado para obter a regra de operação otimizada do sistema de bombeamento e a função-objetivo foi formulada para representar os custos de energia para 20 anos de operação somado aos custos de instalação do sistema de bombeamento (adutora, reservatório superior e conjunto motobomba). Além disso, foram calculados índices e indicadores para facilitar o entendimento e a avaliação da eficiência energética de sistemas de bombeamento. A partir da análise dos resultados dos sistemas cuja operação foi otimizada, e dos resultados dos índices e indicadores, foram estabelecidos critérios e equações que podem ser utilizados para análise da operação, dimensionamento e eficiência energética de sistemas de bombeamento de água. Também, foi desenvolvida uma metodologia para a estimativa da energia mínima que um sistema de bombeamento pode consumir se todos os critérios de eficiência energética forem satisfeitos, ou seja, quando todas as grandezas que compõem o cálculo da energia forem determinadas a partir de critérios otimizados. Essa metodologia foi aplicada em dois cenários: projetos de sistemas de bombeamento de água e diagnóstico de sistemas de bombeamento de água existentes. Na primeira abordagem, o indicador se mostrou útil para inferir sobre consumo de energia e, inclusive, definir o diâmetro ótimo da linha adutora com maior ponderação. Já na segunda abordagem, o indicador tem potencial para ser utilizado na definição da linha de base do sistema e pode auxiliar a tomada de decisão e gestão hidroenergética desses sistemas. / The energy consumed by the pumping systems has high values and can overload the operation of the water supply systems carried out by the sanitation companies. Thus, this research is focused on the development of a methodology to analyze the energy efficiency of these systems. The methodological procedure was developed for a generic system composed of two reservoirs, upper and lower, pumping system and a pipeline, responsible for transporting water between the reservoirs. It was evaluated 96 geometric possibilities for this system, formed from the combination of different static heights, lengths and diameters of the pipeline. Also, three curve formats were studied, with four distinct daily consumption volumes, in two situations, beginning and end of the project. The Shuffled Complex Evolution (SCE-UA) algorithm was employed to obtain the optimal operating rule for the pumping system and the objective function was formulated to represent the energy costs for 20 years of operation plus the pumping system installation costs (pipeline, upper reservoir and pumping system). In addition, indexes and indicators were calculated to facilitate the understanding and evaluation of the energy efficiency of pumping systems. Based on the analysis of the results of the systems whose operation was optimized, and the results of indexes and indicators, criteria and equations were established that can be used to analyze the operation, design and energy efficiency of water pumping systems. Also, a methodology was developed to estimate the minimum energy that a pumping system can consume if all the energy efficiency criteria are met, that is, when all the quantities that compose the energy calculation are determined from optimized criteria. This methodology was applied in two scenarios: projects of water pumping systems and diagnosis of existing water pumping systems. In the first approach, the indicator was useful to infer about energy consumption and, even, to define the optimum diameter of the most heavily weighted pipeline. In the second approach, the indicator has the potential to be used in the definition of the baseline of the system and may help decision making and hydropower management of these systems.
8

A influência do assoreamento na geração de energia hidrelétrica: estudo de caso na Usina de Três Irmãos - SP / The influence of silting in the generation of hydroelectric energy: case study at Três Irmãos power plant - SP

Renato Billia de Miranda 23 February 2011 (has links)
Com a crescente demanda de energia elétrica há a necessidade da criação de novas fontes de energia e otimização das fontes já existentes. No caso de países que apresentam uma matriz energética predominantemente hidrelétrica como o Brasil, com grandes usinas e reservatórios, os estudos sedimentológicos e os levantamentos batimétricos se apresentam como importantes ferramentas para melhorar o planejamento e o gerenciamento dos recursos hídricos e energéticos. Atualmente, muitos reservatórios hidrelétricos operam com dados defasados devido, principalmente, ao contínuo processo de assoreamento dos reservatórios. Este fato faz com que as políticas de gestão e operação destes reservatórios sejam realizadas a partir de dados diferentes dos encontrados na realidade. Neste contexto, a dissertação apresenta um estudo de caso no Reservatório de Três Irmãos (SP), onde foi realizado um levantamento batimétrico em 2008, e a partir da comparação dos dados obtidos neste levantamento com os dados fornecidos pela concessionária de energia, de 1975, foi possível estimar as perdas de volume total, útil e morto do reservatório que correspondem a 14,3%, 14,5% e 14,2%, respectivamente. A partir da observação destas modificações nos dados operacionais do reservatório em estudo, foi realizada a simulação da operação do reservatório e da usina hidrelétrica por meio do software AcquaNet, com a intenção de analisar qual a interferência do assoreamento do reservatório na geração de energia elétrica, durante o período de 1993 a 2008. Com os resultados foi constatado que a diminuição do volume útil do reservatório (devido ao assoreamento) acarretou na redução da energia gerada pela usina durante o período analisado. Também foi possível estimar as perdas financeiras da concessionária de energia com a redução da produção energética. Foram sugeridas, ainda, algumas medidas preventivas e corretivas para a redução do processo de assoreamento do reservatório em estudo. / With the increasing demand of energy, it is necessary to create new sources and optimize the ones that already exist. In the case of countries that present an energy matrix predominantly hydroelectric such as Brazil, where there are huge power plants and reservoirs, the studies on sedimentation and beating surveys are presented as important tools to sharpen the planning and the management of water and energy resources. Currently, most of the hydroelectric reservoirs operate in gapped data, due to, mainly, the continuing process of reservoirs silting. This makes management policies and operation of these reservoirs be performed from data that differ from the ones found in reality. In this context, this dissertation presents a case study at the Três Irmãos Reservoir (SP), where a beating survey was carried out in 2008, and, from the comparison of the data revealed in that survey with the data provided by the power utility in 1975, it was possible to estimate the losses of total capacity, live storage and void volume of the reservoir, which correspond to 14,3%, 14,5% e 14,2%, respectively. From the observation of these operational data modification of the reservoir under study was performed the simulate of the operation of the reservoir and hydroelectric plant with the employing of the AcquaNet software with the intention to look into the interference of silting of the reservoir in generate electricity during the period 1993 to 2008. With the results was found that the decrease in the capacity of the reservoir (due to siltation) resulted in the reduction of energy generated by the plant during the period analyzed. With this verification, it was also possible to estimate the financial losses of the power utility with the reduction of energy production. Was suggested also, some preventive and corrective measures to reduce siltation process in the reservoir under study.
9

Perfil da geração hidrelétrica no Oeste e Sudoeste do Paraná / Profile of hydropower generation in the west and southwest of Paraná

Silva, Fabricio Ströher da 09 March 2018 (has links)
Submitted by Rosangela Silva (rosangela.silva3@unioeste.br) on 2018-06-25T23:12:30Z No. of bitstreams: 2 Fabricio_S_Silva.pdf: 2675376 bytes, checksum: 37796693d06d9e4b32f5991fd61d17d1 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-06-25T23:12:30Z (GMT). No. of bitstreams: 2 Fabricio_S_Silva.pdf: 2675376 bytes, checksum: 37796693d06d9e4b32f5991fd61d17d1 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-09 / Hydroelectric generation is the main source of electricity in Brazil and also in the West and Southwest of Paraná. Year after year the energy matrix has been diversifying, including new sources, such as wind power. However, due to the power accumulation characteristic of hydroelectric plants, this type of source is important for the stability of the electric system. Currently, hydroelectric power corresponds to just over 60% of all power installed in Brazil. Particularly in the West and Southwest of Paraná, this number increases and Paraná's share in the Brazilian matrix is approximately 16% of all installed power. In order to verify the participation of these regions in the hydropower matrix and also their production, a survey was made of the installed potential and the constructive profile of the hydroenergy projects. In addition, the flow and production trends of the Salto Santiago hydroelectric plant in the Iguaçu River basin and the Melissa hydroelectric plant in the Piquiri river basin were verified in the 2003 to 2017 period. Finally, a conceptual map of the western and southwestern regions of Paraná was elaborated with the hydroelectric generation profile. It was noticed by the survey that the regions of the study have great participation in the hydroelectric matrix of Brazil and that its production and the flow of the rivers in the entrance of these remains practically unchanged in the studied period. / A geração hidrelétrica é a principal fonte de energia elétrica no Brasil e do Oeste e Sudoeste do Paraná. Ano após ano a matriz energética vem se diversificando, sendo nela inseridas novas fontes, como por exemplo a eólica. Porém pela característica de acumulação de energia potência das hidrelétricas faz com que este tipo de fonte seja importante para a estabilidade do sistema elétrico. Nos dias atuais a energia hidrelétrica corresponde a pouco mais que 60% de toda potência instalada no Brasil. Em especial na região Oeste e Sudoeste do Paraná, este número aumenta e a participação do Paraná na matriz brasileira é de aproximadamente 16% de toda potência instalada. Para verificar como está a participação destas regiões na matriz hidroenergética e sua produção, foi realizado um levantamento do potencial instalado e do perfil construtivo dos empreendimentos hidroenergéticos. Além disto foi verificada a tendência das vazões e produção no período de 2003 a 2017 da hidrelétrica Salto Santiago na bacia do Rio Iguaçu e a hidrelétrica Melissa na bacia do rio Piquiri. Por fim, foi elaborado um mapa conceitual das regiões Oeste e Sudoeste do Paraná com o perfil da geração hidrelétrica. Concluiu-se pelo levantamento que as regiões do estudo têm grande participação na matriz hidrelétrica do Brasil e que sua produção e a vazão dos rios na entrada destas permanece praticamente inalterada no período do estudado.

Page generated in 0.0506 seconds