• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeitos agudos de flunitrazepam sobre o metabolismo da homocisteína em jovens saudáveis / Acute effects of flunitrazepam on the metabolism of homocysteine in healthy young

Grego, Bruno Henrique do Carmo [UNIFESP] 25 March 2009 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:49:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-25. Added 1 bitstream(s) on 2015-08-11T03:26:10Z : No. of bitstreams: 1 Publico-126.pdf: 520997 bytes, checksum: 85e8cbd8b81462d16c1e17d94e15990a (MD5) / Altos níveis de cortisol plasmático têm sido associados ao aumento de homocisteína. No presente estudo investigamos se a diminuição da concentração de cortisol, induzida pela administração aguda e oral de um benzodiazepínico, poderia diminuir níveis plasmáticos de homocisteína, e se tais mudanças seriam similares em ambos os gêneros. O estudo consistiu na administração de doses orais agudas de flunitrazepam e placebo, em 24 voluntários com idades entre 18 e 35 anos, saudáveis de ambos os sexos. Amostras de sangue foram coletadas após o pico plasmático da concentração de flunitrazepam. Diversos parâmetros bioquímicos foram analisados: homocisteína, cisteína, vitaminas B6 e B12, como também hormônios sexuais. O flunitrazepam diminuiu os níveis plasmáticos do cortisol, cisteína e homocisteína, independentemente do gênero. Não foram achadas correlações entre o cortisol e outros parâmetros bioquímicos. As concentrações plasmáticas de cisteína e homocisteína foram negativamente correlacionadas com concentrações plasmáticas de flunitrazepam, sugerindo que tais alterações nesses aminoácidos estariam relacionadas ao metabolismo desse benzodiazepínico. A administração aguda de flunitrazepam diminui níveis plasmáticos de homocisteína e cisteína por meio de mecanismos desconhecidos que não pareceram ter relação com as alterações plasmáticas de cortisol. Devido à importância da homocisteína como fator de risco de diversas doenças, tais mecanismos são alvos em potencial para a aplicação clínica. / Background: High cortisol plasma concentrations have been shown to be associated with increases in homocysteine. Here we studied whether decreases in cortisol, induced by an acute oral dose of a benzodiazepine, could decrease homocysteine, and if changes were similar in both genders. Methods: This was a double-blind, cross-over design study of acute oral doses of flunitrazepam and placebo in young, healthy, male and female volunteers. Blood samples were collected after peak-plasma concentration of flunitrazepam. Various biochemical parameters were analysed, such as homocysteine, cysteine, folate, vitamins B6 and B12, as well as male and female hormones. Results: flunitrazepam reduced cortisol, cysteine and homocysteine plasma concentrations, irrespective of gender. No correlations were found between cortisol and other biochemical markers. Plasma concentration of cysteine and homocysteine were negatively correlated with plasma flunitrazepam concentration, suggesting that changes in these amino acids were related to the metabolism of this benzodiazepine. Conclusion: Acute administration of flunitrazepam decreases plasma homocysteine and cysteine through as yet unknown mechanisms that do not seem related to changes in cortisol. Given the importance of homocysteine as a marker of life-threatening disorders, such mechanisms are potential targets for clinical application. / TEDE / BV UNIFESP: Teses e dissertações
2

Efeitos dos polimorfismos no gene TC2 nas concentrações dos metabólicos marcadores da deficiência de cobalamina em gestantes e seus recém nascidos / Effects of polymorphisms in TC2 gene on concentrations of metabolites cobalamin deficient markers of metabolism in pregnant women and their neonates

Trentin, Renata 28 June 2006 (has links)
A transcobalamina II (TCII) é a única proteína que leva a cobalamina (Cbl) para dentro das células. A TCII ligada a Cbl é denominada Holo-TC. Polimorfismos no gene TC2 podem alterar tanto a função como a concentração de Holo-TC. Os objetivos deste estudo foram avaliar se o parâmetro Holo-TC é um bom marcador de deficiência de Cbl; avaliar o efeito dos polimorfismos TC2 P259R, I23V e Q234R nos marcadores da deficiência da Cbl; verificar os fatores de predição para os valores de tHcy, SAM/SAH, MMA e Holo-TC nas gestantes e seus recém- nascidos. A Holo-TC não foi bom marcador para discriminar as gestantes com e sem deficiência de Cbl, diferente do encontrado no grupo de recém nascidos. Os genótipos matemos para os polimorfismos TC2 P259R e I23V não foram associados com as alterações nos valores matemos de tHcy, MMA e Holo-TC. Os neonatos portadores dos genótipos PR+RR apresentaram menores valores da razão SAM/SAH e maiores de MMA. Os neonatos com genótipos 23V+23VV apresentaram menores valores de SAM e maiores valores de tHcy. A combinação dos genótipos IV+VV/PR+RR no grupo de gestantes foi associada a menores valores de SAM. Já os neonatos com a mesma combinação de genótipos apresentaram menores valores de SAM e da razão SAM/SAH. O folato sérico foi o melhor fator de predição para a variação da tHcy materna, e a Cbl para os valores de Holo-TC, e finalmente a creatinina e a Cbl foram os fatores de predição para os valores de MMA. A Cbl e o folato foram os preditores para a tHcy neonatal quando foi utilizado apenas as variáveis independentes maternas no modelo de regressão linear múltipla. No entanto, quando as variáveis independentes foram as neonatais, Cbl, folato sérico e SAM/SAH neonatais foram as selecionadas para explicar os valores de tHcy neonatal. Para os modelos neonatais de MMA, a Cbl materna foi a única selecionada quando o modelo foi feito com variáveis independentes maternas. E noutro modelo da MMA neonatal, a Cbl e o genótipo PR + RR neonatal explicaram a variabilidade do MMA neonatal. Para a razão SAM/SAH neonatal, foram o folato sérico e o genótipo RR maternos as variáveis selecionadas quando só foram colocadas as variáveis independentes maternas no modelo. E finalmente, a tHcy e genótipos PR + RR foram as variáveis neonatais selecionadas no modelo de regressão linear múltipla para a razão SAM/SAH neonatal. Podemos concluir que os genótipos para os polimorfismos TC2 P259R e I23V não estão associados a variabilidade dos valores matemos dos metabólitos, no entanto, no recém nascido esta associação foi evidenciada. / Transcobalamin II (TCII) is the only protein that can take cobalamin (Cbl) into cells. When TCII is bound to the Cbl it is called Holo-TC. Polymorphisms inTC2 gene can alter both the function and the concentration of Holo-TC. The objective of this study was to evaluate whether the parameter Holo-TC is a good Cbl deficiency marker; to evaluate the effect of the polymorphisms TC2 P259R, I23V and Q234R in the Cbl deficiency markers; to verify the prediction factors for the values of tHcy, SAM/S~ MMA and Holo-TC in pregnant women and their neonates. Holo-TC has proved not be a good marker for discriminating pregnant women with Cbl deficiency from those without Cbl deficiency, unlike what was seen in the neonatal group. Maternal genotypes for polymorphisms TC2 P259R and I23 V were not related with the alterations ofmaternal values of tHcy, MMA and Holo-TC. The neonates presenting genotypes PR+RR showed lower SAM/SAH ratio values and higher MMA values. The neonates with genotypes 23V+23VV presented lower SAM values and higher tHcy values. The combination of genotypes IV+VV/PR+RR in the group of pregnant women was related with lower SAM values. On the other hand, the neonates presenting the same combination of genotypes presented lower SAM values and SAM/SAH ratio values. Se rum folate was the best predictor for the variation of the maternal tHcy, and Cbl for the Holo-TC values. The creatinine and the Cbl were the predictors for the values of MMA. Cbl and folate were the predictors for the neonatal tHcy when only the maternal independent variables were used in the multiple linear regression model. However, when the neonatal independent variables were used, Cbl, serum folate and SAM/SAH of neonates were selected to explain the neonatal tHcy values. For the neonatal models of MMA, only the maternal Cbl was selected for the model with maternal independent variables. In another neonatal MMA model, Cbl and neonatal PR + RR genotype explained the variability of the neonatal MMA. For the neonatal SAM/SAH ratio, serum folate and maternal RR genotype were the variables selected when only the maternal independent variables were used in the model. Finally, tHcy and genotypes PR + RR were the neonatal variables selected in the multiple linear regression model for the neonatal SAM/SAH ratio. We have concluded that the genotypes for the polymorphisms TC2 P25 9R and I23 V are not related to the variability of the maternal values of the metabolites; however, this relation is clear when evaluating the values observed in their newborn babies.
3

Efeitos dos polimorfismos no gene TC2 nas concentrações dos metabólicos marcadores da deficiência de cobalamina em gestantes e seus recém nascidos / Effects of polymorphisms in TC2 gene on concentrations of metabolites cobalamin deficient markers of metabolism in pregnant women and their neonates

Renata Trentin 28 June 2006 (has links)
A transcobalamina II (TCII) é a única proteína que leva a cobalamina (Cbl) para dentro das células. A TCII ligada a Cbl é denominada Holo-TC. Polimorfismos no gene TC2 podem alterar tanto a função como a concentração de Holo-TC. Os objetivos deste estudo foram avaliar se o parâmetro Holo-TC é um bom marcador de deficiência de Cbl; avaliar o efeito dos polimorfismos TC2 P259R, I23V e Q234R nos marcadores da deficiência da Cbl; verificar os fatores de predição para os valores de tHcy, SAM/SAH, MMA e Holo-TC nas gestantes e seus recém- nascidos. A Holo-TC não foi bom marcador para discriminar as gestantes com e sem deficiência de Cbl, diferente do encontrado no grupo de recém nascidos. Os genótipos matemos para os polimorfismos TC2 P259R e I23V não foram associados com as alterações nos valores matemos de tHcy, MMA e Holo-TC. Os neonatos portadores dos genótipos PR+RR apresentaram menores valores da razão SAM/SAH e maiores de MMA. Os neonatos com genótipos 23V+23VV apresentaram menores valores de SAM e maiores valores de tHcy. A combinação dos genótipos IV+VV/PR+RR no grupo de gestantes foi associada a menores valores de SAM. Já os neonatos com a mesma combinação de genótipos apresentaram menores valores de SAM e da razão SAM/SAH. O folato sérico foi o melhor fator de predição para a variação da tHcy materna, e a Cbl para os valores de Holo-TC, e finalmente a creatinina e a Cbl foram os fatores de predição para os valores de MMA. A Cbl e o folato foram os preditores para a tHcy neonatal quando foi utilizado apenas as variáveis independentes maternas no modelo de regressão linear múltipla. No entanto, quando as variáveis independentes foram as neonatais, Cbl, folato sérico e SAM/SAH neonatais foram as selecionadas para explicar os valores de tHcy neonatal. Para os modelos neonatais de MMA, a Cbl materna foi a única selecionada quando o modelo foi feito com variáveis independentes maternas. E noutro modelo da MMA neonatal, a Cbl e o genótipo PR + RR neonatal explicaram a variabilidade do MMA neonatal. Para a razão SAM/SAH neonatal, foram o folato sérico e o genótipo RR maternos as variáveis selecionadas quando só foram colocadas as variáveis independentes maternas no modelo. E finalmente, a tHcy e genótipos PR + RR foram as variáveis neonatais selecionadas no modelo de regressão linear múltipla para a razão SAM/SAH neonatal. Podemos concluir que os genótipos para os polimorfismos TC2 P259R e I23V não estão associados a variabilidade dos valores matemos dos metabólitos, no entanto, no recém nascido esta associação foi evidenciada. / Transcobalamin II (TCII) is the only protein that can take cobalamin (Cbl) into cells. When TCII is bound to the Cbl it is called Holo-TC. Polymorphisms inTC2 gene can alter both the function and the concentration of Holo-TC. The objective of this study was to evaluate whether the parameter Holo-TC is a good Cbl deficiency marker; to evaluate the effect of the polymorphisms TC2 P259R, I23V and Q234R in the Cbl deficiency markers; to verify the prediction factors for the values of tHcy, SAM/S~ MMA and Holo-TC in pregnant women and their neonates. Holo-TC has proved not be a good marker for discriminating pregnant women with Cbl deficiency from those without Cbl deficiency, unlike what was seen in the neonatal group. Maternal genotypes for polymorphisms TC2 P259R and I23 V were not related with the alterations ofmaternal values of tHcy, MMA and Holo-TC. The neonates presenting genotypes PR+RR showed lower SAM/SAH ratio values and higher MMA values. The neonates with genotypes 23V+23VV presented lower SAM values and higher tHcy values. The combination of genotypes IV+VV/PR+RR in the group of pregnant women was related with lower SAM values. On the other hand, the neonates presenting the same combination of genotypes presented lower SAM values and SAM/SAH ratio values. Se rum folate was the best predictor for the variation of the maternal tHcy, and Cbl for the Holo-TC values. The creatinine and the Cbl were the predictors for the values of MMA. Cbl and folate were the predictors for the neonatal tHcy when only the maternal independent variables were used in the multiple linear regression model. However, when the neonatal independent variables were used, Cbl, serum folate and SAM/SAH of neonates were selected to explain the neonatal tHcy values. For the neonatal models of MMA, only the maternal Cbl was selected for the model with maternal independent variables. In another neonatal MMA model, Cbl and neonatal PR + RR genotype explained the variability of the neonatal MMA. For the neonatal SAM/SAH ratio, serum folate and maternal RR genotype were the variables selected when only the maternal independent variables were used in the model. Finally, tHcy and genotypes PR + RR were the neonatal variables selected in the multiple linear regression model for the neonatal SAM/SAH ratio. We have concluded that the genotypes for the polymorphisms TC2 P25 9R and I23 V are not related to the variability of the maternal values of the metabolites; however, this relation is clear when evaluating the values observed in their newborn babies.

Page generated in 0.0385 seconds