An analysis of maximum residential energy-efficiency in hot and humid climates

Malhotra, Mini 12 April 2006 (has links)
Energy-efficient building design involves minimizing the energy use and optimizing the performance of individual systems and components of the building. The benefits of energyefficient design, in the residential sector, are direct and tangible, provided that design strategies with a substantial combined energy and cost-saving potential are adopted. Many studies have been performed to evaluate the energy-saving potential and the costeffectiveness of various design options, and to identify conditions for optimizing the performance of building systems and components. The results of these studies, published in various resources, were analyzed discretely using different techniques, and were reported using different bases for comparison. Considering the complex interaction of, and energy flows through various building components, it is difficult to directly compare/combine the results from various studies to determine the energy-saving potential of combination of strategies, and to select an appropriate set of strategies for making design decisions. Therefore, this thesis develops a comprehensive survey and analysis of energy-efficient design strategies and their energy-saving potential, in isolation as well as in combination, using a DOE-2 simulation model of a prototype house in the hot and humid climate of Houston, Texas. Optimized strategies that included building configuration, materials/ assembly for building envelop components, and efficient mechanical and electrical systems, equipment and appliances, were applied in combination that could minimize the annual energy use. Application of these strategies is expected to allow downsizing systems and equipment and to confirm their operation at their rated performance, resulting in additional installation and operation cost savings. The study is concluded by outlining the procedures for selecting optimized set of strategies, and by developing guidelines for achieving maximum energy-efficiency in singlefamily detached houses in hot and humid climates. Thus, this study will facilitate the selection of energy-saving measures for their individual or combined application for developing energyefficient residences in hot and humid climates.
2

Modeling Building Energy Use and HVAC Efficiency Improvements in Extreme Hot and Humid Regions

Bible, Mitchell 2011 August 1900 (has links)
An energy analysis was performed on the Texas A & M University at Qatar building in Doha, Qatar. The building and its HVAC systems were modeled using EnergyPlus. Building chilled water and electrical data were collected to validate the computer simulation. The simulated monthly electricity consumption was within plus/minus 5 percent of the metered building data. Ninety-five percent of simulated hourly electricity data in a day were within plus/minus 10 percent of metered data. Monthly chilled water demand was within plus/minus 18 percent of measurements, and simulated monthly demand was correlated to metered monthly values with an R-squared correlation coefficient of 0.95. Once the simulation was verified with the metered data, an optimization of the building's HVAC systems was performed. Better utilizing the building's variable speed fans at part loads showed potential annual electricity savings of 16 percent over the base case, with another 22 percent savings in chilled water energy. After converting chilled water savings to equivalent chiller electricity savings, the potential utility cost savings over the base case were found to be $90,000/yr at local utility rates. Reducing outdoor air intake to ASHRAE indoor air quality minimums yielded an additional 17 percent in potential chilled water savings and brought total monetary savings over the base case to $110,000/yr. Using a dedicated outside air system to precisely control individual zone ventilation showed potential for an additional 12 percent chilled water savings and $14,000 in yearly utility savings, while also eliminating cases of under-ventilation. A hypothetical retrofit of fan powered terminal units (FPTU's) resulted in energy savings only at very low minimum flow rates, below ventilation standards. Savings were never more than 20 percent over the no-fan case. Series FPTU's showed no savings at any flow setting and negligible difference was found between ECM and SCR motor control. Finally, the dependence on climate of each improvement was studied. Simulations were run in the relatively milder climates of Houston and Phoenix and compared to those found for Doha. It was found that variable speed fan operation is a more cost effective option for milder climates, while outside air control is more cost effective in extreme hot and humid climates such as Doha. Future study is needed to make the FPTU model valid for different climates and flow ranges.