• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Hydrographic Characteristics of the Love River

Tsai, Jr-wei 16 September 2004 (has links)
In this study, twenty-seven experiments of transport and hydrographic observations were conducted at 9 bridges along the Love River during the period between 2001/12/20 and 2003/9/10. In each experiment repeated measurements were made at each bridge every two hours for a total period of 12 hours. An additional experiment (the 28th experiment) was conducted at 2004/6/16 in the Chihsien Bridge which consists of continuous measurements of velocity, depth and turbidity with a total length of 27 hours. Our results indicate that the Love River is influenced by the incoming tides from the river mouth up to the Dingxin Bridge. The tidal range is approximately 1m during spring tides (10cm during neap tides) at river mouth. The velocity at the Chihsien Bridge has a high frequency variation with a period of approximately 1 hour and amplitude of 20 cm/s during the 28th experiment. Salinity variations are in phase with tides, while turbidity and tides are out of phase. Harmonic analysis of depth, velocity, salinity and turbidity data all indicate that K1 is the principal tidal constituent followed by M2. River transport in the lower estuary is mainly comprised of two parts: tide and river discharge. The tidal induced transport is estimated to be ¡Ó30 CMS and net river discharge is about 1~9 CMS. The upper estuary is affected by two transport mechanisms: agricultural runoff and rain precipitation. After analyzing the measurement results, the transport of the upper branches is estimated to be 0~0.5 CMS during dry seasons and 1~5 CMS during rainy seasons. The agricultural transport reaches its maximum value in January with an estimated rate of 1~2.8 CMS. For the upper branches of Love River, the ratio£\between the hydraulic depth D and hydraulic radius R is found to reach a constant value of 0.9~1.0 when the transport Q is less than 2CMS, and£\is 0.8~0.9 when Q is greater than 2 CMS. The relationship between Q and the section factor TaDb, where T is the channel width, is found to be TD5/3=7.171Q (Dingxin Bridge) and TD5/3=0.744Q (Hougang Bridge) based on Manning formula. Finally, the relationship between Q and D is found to be D=1.811Q0.2981 (Longxin bridge) and D=0.266Q0.256 (Hougang Bridge).
2

Metodologia para determinação da perda de carga localizada em emissores não coaxiais integrados a tubos de polietileno / Methodology for Localized head loss determination of non coaxial emitters inserted in polyethylene pipe

Rettore Neto, Osvaldo 25 February 2008 (has links)
O procedimento de dimensionamento de uma linha lateral de irrigação localizada necessita ser avaliado com precisão, devido às perdas de carga tanto distribuídas na tubulação como nas inserções dos emissores com os tubos. Devido a isso, desenvolveu-se uma metodologia para a determinação da perda de carga localizada mediante a formulação de um modelo matemático a partir do índice de obstrução. Estas perdas localizadas podem ser significativas quando comparadas com as perdas de carga totais, devido ao grande número de emissores instalados ao longo da linha lateral. O experimento foi junto ao Departamento de Engenharia Rural (ESALQ-USP) e ajustado para valores número de Reynolds (R), no intervalo de 7.480 a 32.597 para proporcionar fluxo turbulento e velocidade máxima de 2,0 m s-1. A pesquisa foi conduzida em duas etapas: 1) ajuste do fator f para um seguimento de 0,5 m de tubo,sendo realizada 10 repetições, com o intuito de validação da metodologia empregada comparando-se o ajuste dos dados encontrados com os trabalhos existentes na literatura, 2) determinação da perda de carga (hf) em um seguimento de tubo de 1 m de comprimento com emissor devidamente vedado, portanto, pela diferença entre a hf do tubo mais o emissor e a hf do tubo obtido na primeira etapa, obteve-se a perda de carga localizada do emissor (hfe). Além disso, com a determinação da geometria do emissor, pelo projetor ótico HB 400, formulou-se uma equação que permitiu o cálculo da perda de carga localizada utilizando-se as características geométricas do emissor (comprimento do emissor, índice de obstrução e coeficiente de contração). Pelos resultados obtidos para 4 modelos utilizados, o modelo estimou satisfatoriamente para 2 modelos, e também verificou-se que o modelo apresentou um desempenho classificado como \'ótimo\', portanto, podendo ser empregado para estimativa de perda de carga localizada provocada por emissores integrados não coaxiais com geometria semelhante ao emissor Uniram e Drip Net. / The design of a lateral line of trickle irrigation requires an accurate evaluation of head losses in not only the pipe but the emitters as well. A procedure was developed to determine localized head losses within the emitters by the formulation of a mathematical model accounting for the obstruction caused by the insertion point. These localized losses can be significant when compared with the total head losses within the system, due to the large number of emitters typically installed along the lateral line. An experiment was carried out by altering flow characteristics to create Reynolds Number (R) in the interval from 7480 to 32597 to provide turbulent flow and a maximum velocity of 2.0 m s-1. The geometry of the emitter point was determined by an optical projector and sensor. An equation was formulated that allows the localized head loss calculation using the geometric characteristics of the emitter (emitter length, obstruction index and the contraction coefficient). The obtained results for 4 used models, the model esteemed satisfactorily for 2 models, and was also verified that the model presents an acting classified as \'great\', therefore, could be used to estimate localized head loss provoked by non coaxial emitters inserted in polyethylene pipe with similar geometry as the Uniram and Drip Net emitters.
3

Metodologia para determinação da perda de carga localizada em emissores não coaxiais integrados a tubos de polietileno / Methodology for Localized head loss determination of non coaxial emitters inserted in polyethylene pipe

Osvaldo Rettore Neto 25 February 2008 (has links)
O procedimento de dimensionamento de uma linha lateral de irrigação localizada necessita ser avaliado com precisão, devido às perdas de carga tanto distribuídas na tubulação como nas inserções dos emissores com os tubos. Devido a isso, desenvolveu-se uma metodologia para a determinação da perda de carga localizada mediante a formulação de um modelo matemático a partir do índice de obstrução. Estas perdas localizadas podem ser significativas quando comparadas com as perdas de carga totais, devido ao grande número de emissores instalados ao longo da linha lateral. O experimento foi junto ao Departamento de Engenharia Rural (ESALQ-USP) e ajustado para valores número de Reynolds (R), no intervalo de 7.480 a 32.597 para proporcionar fluxo turbulento e velocidade máxima de 2,0 m s-1. A pesquisa foi conduzida em duas etapas: 1) ajuste do fator f para um seguimento de 0,5 m de tubo,sendo realizada 10 repetições, com o intuito de validação da metodologia empregada comparando-se o ajuste dos dados encontrados com os trabalhos existentes na literatura, 2) determinação da perda de carga (hf) em um seguimento de tubo de 1 m de comprimento com emissor devidamente vedado, portanto, pela diferença entre a hf do tubo mais o emissor e a hf do tubo obtido na primeira etapa, obteve-se a perda de carga localizada do emissor (hfe). Além disso, com a determinação da geometria do emissor, pelo projetor ótico HB 400, formulou-se uma equação que permitiu o cálculo da perda de carga localizada utilizando-se as características geométricas do emissor (comprimento do emissor, índice de obstrução e coeficiente de contração). Pelos resultados obtidos para 4 modelos utilizados, o modelo estimou satisfatoriamente para 2 modelos, e também verificou-se que o modelo apresentou um desempenho classificado como \'ótimo\', portanto, podendo ser empregado para estimativa de perda de carga localizada provocada por emissores integrados não coaxiais com geometria semelhante ao emissor Uniram e Drip Net. / The design of a lateral line of trickle irrigation requires an accurate evaluation of head losses in not only the pipe but the emitters as well. A procedure was developed to determine localized head losses within the emitters by the formulation of a mathematical model accounting for the obstruction caused by the insertion point. These localized losses can be significant when compared with the total head losses within the system, due to the large number of emitters typically installed along the lateral line. An experiment was carried out by altering flow characteristics to create Reynolds Number (R) in the interval from 7480 to 32597 to provide turbulent flow and a maximum velocity of 2.0 m s-1. The geometry of the emitter point was determined by an optical projector and sensor. An equation was formulated that allows the localized head loss calculation using the geometric characteristics of the emitter (emitter length, obstruction index and the contraction coefficient). The obtained results for 4 used models, the model esteemed satisfactorily for 2 models, and was also verified that the model presents an acting classified as \'great\', therefore, could be used to estimate localized head loss provoked by non coaxial emitters inserted in polyethylene pipe with similar geometry as the Uniram and Drip Net emitters.

Page generated in 0.0562 seconds