Spelling suggestions: "subject:"imagem dde fluorescência dde raiosx."" "subject:"imagem dde fluorescência dde raiosâx.""
1 |
X-Ray fluorescence imaging system based on Thick-GEM detectors / Sistema de imagem de fluorescência de raios-X baseado em detectores Thick-GEMSouza, Geovane Grossi Araújo de 19 February 2019 (has links)
GEMs (Gas Electron Multiplier) and Thick-GEMs (Thick-Gas Electron Multiplier) are MPGDs (Micropattern Gas Detector) that make part of the new generation of gaseous detectors, allowing high counting rates, low cost when compared to solid state detectors, high radiation hardness and gain when using multiple structures. Besides that, the handling and maintenance of these detectors is relatively simple, being versatile to detect different types of radiation. Therefore, these detectors are an effective alternative to build imaging systems with large sensitive area. This work consists in the study and characterization of a set of gaseous detectors, more specifically the Thick-GEMs produced in the High Energy Physics and Instrumentation Center at IFUSP, which were tested showing promising results in terms of gain, energy resolution and operational stability. However, due to the low signal-to-noise ratio of the Thick-GEMs, the X-ray fluorescence imaging system was mounted using GEMs. During this work the necessary software tools for image processing and reconstruction were developed as a parallel study in computational simulations to better understand the operation of gaseous detectors. X-ray fluorescence techniques are essential in areas such as medicine and the study of historical and cultural heritage since they are non-invasive and non-destructive. Techniques to check the authenticity of masterpieces are required and museums are gradually becoming more interested in the Physics and instrumentation needed to characterize their patrimony. / Os GEMs (Gas Electron Multiplier) e Thick-GEMs (Thick-Gas Electron Multiplier) são estruturas do tipo MPGD (Micropattern Gas Detector) que fazem parte da nova geração de detectores de radiação a gás e permitem altas taxas de contagens, baixo custo quando comparados com os detectores de estado sólido, uma elevada resistência à radiação e ganhos elevados, quando utilizadas estruturas múltiplas para multiplicação. Além disso, o manuseio e manutenção desses detectores é relativamente simples, sendo versáteis em relação à montagem podendo detectar diferentes tipos de radiação. Sendo assim, a utilização desses detectores é uma alternativa eficiente para montar um sistema de imagem com grande área sensível. Este trabalho consiste no estudo e caracterização de um conjunto de detectores gasosos, mais especificamente os Thick-GEMs produzidos pelo grupo de Física de altas energias e Instrumentação do IFUSP, que foram testados para serem empregados em um sistema de imagem de fluorescência de raios-X. Os Thick-GEMs testados apresentaram resultados promissores em termos de ganho, resolução em energia e estabilidade operacional. No entanto, devido à baixa relação sinal-ruído, um sistema de imagem de fluorescência de raios-X foi montado utilizando GEMs. Durante o trabalho as ferramentas de software necessárias para processamento e reconstrução de imagens foram desenvolvidas, assim como um estudo paralelo de simulações computacionais para entender melhor o funcionamento de detectores gasosos. Técnicas como o imageamento por fluorescência de raios-X são de suma importância pois são consideradas não invasivas e não destrutivas. Sua utilização tem uma importância imprescindível nas áreas da medicina e na análise de patrimônios histórico e cultural. Atualmente, a verificação e validação de autenticidade de obras é um requisito obrigatório e alguns museus começam a se interessar cada vez mais em áreas da Física e da instrumentação necessária para caracterizar o seu patrimônio.
|
2 |
X-Ray fluorescence imaging system based on Thick-GEM detectors / Sistema de imagem de fluorescência de raios-X baseado em detectores Thick-GEMGeovane Grossi Araújo de Souza 19 February 2019 (has links)
GEMs (Gas Electron Multiplier) and Thick-GEMs (Thick-Gas Electron Multiplier) are MPGDs (Micropattern Gas Detector) that make part of the new generation of gaseous detectors, allowing high counting rates, low cost when compared to solid state detectors, high radiation hardness and gain when using multiple structures. Besides that, the handling and maintenance of these detectors is relatively simple, being versatile to detect different types of radiation. Therefore, these detectors are an effective alternative to build imaging systems with large sensitive area. This work consists in the study and characterization of a set of gaseous detectors, more specifically the Thick-GEMs produced in the High Energy Physics and Instrumentation Center at IFUSP, which were tested showing promising results in terms of gain, energy resolution and operational stability. However, due to the low signal-to-noise ratio of the Thick-GEMs, the X-ray fluorescence imaging system was mounted using GEMs. During this work the necessary software tools for image processing and reconstruction were developed as a parallel study in computational simulations to better understand the operation of gaseous detectors. X-ray fluorescence techniques are essential in areas such as medicine and the study of historical and cultural heritage since they are non-invasive and non-destructive. Techniques to check the authenticity of masterpieces are required and museums are gradually becoming more interested in the Physics and instrumentation needed to characterize their patrimony. / Os GEMs (Gas Electron Multiplier) e Thick-GEMs (Thick-Gas Electron Multiplier) são estruturas do tipo MPGD (Micropattern Gas Detector) que fazem parte da nova geração de detectores de radiação a gás e permitem altas taxas de contagens, baixo custo quando comparados com os detectores de estado sólido, uma elevada resistência à radiação e ganhos elevados, quando utilizadas estruturas múltiplas para multiplicação. Além disso, o manuseio e manutenção desses detectores é relativamente simples, sendo versáteis em relação à montagem podendo detectar diferentes tipos de radiação. Sendo assim, a utilização desses detectores é uma alternativa eficiente para montar um sistema de imagem com grande área sensível. Este trabalho consiste no estudo e caracterização de um conjunto de detectores gasosos, mais especificamente os Thick-GEMs produzidos pelo grupo de Física de altas energias e Instrumentação do IFUSP, que foram testados para serem empregados em um sistema de imagem de fluorescência de raios-X. Os Thick-GEMs testados apresentaram resultados promissores em termos de ganho, resolução em energia e estabilidade operacional. No entanto, devido à baixa relação sinal-ruído, um sistema de imagem de fluorescência de raios-X foi montado utilizando GEMs. Durante o trabalho as ferramentas de software necessárias para processamento e reconstrução de imagens foram desenvolvidas, assim como um estudo paralelo de simulações computacionais para entender melhor o funcionamento de detectores gasosos. Técnicas como o imageamento por fluorescência de raios-X são de suma importância pois são consideradas não invasivas e não destrutivas. Sua utilização tem uma importância imprescindível nas áreas da medicina e na análise de patrimônios histórico e cultural. Atualmente, a verificação e validação de autenticidade de obras é um requisito obrigatório e alguns museus começam a se interessar cada vez mais em áreas da Física e da instrumentação necessária para caracterizar o seu patrimônio.
|
Page generated in 0.1106 seconds