Spelling suggestions: "subject:"instrumentación""
1 |
Análise da contaminação das águas do córrego São Lourenço (Nova Friburgo, RJ) por agrotóxicos organofosforados e carbamatos / Contamination analisys of São Lourenço river water (Nova Friburgo/RJ) by organophosphorade a carbamate pesticidesAndré Ribeiro Silva de Almeida 30 June 2008 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / O córrego de São Lourenço (Nova Friburgo RJ), situado na principal região agrícola do estado, representa um importante manancial hídrico do município de Nova Friburgo que percorre um vale onde se concentram as principais lavouras responsáveis pela produção de olerícolas do Estado. Esta localidade apresenta expressiva relação de consumo de agrotóxicos por trabalhador (56 kg/trabalhador/ano). Assim, este córrego recebe todos os resíduos provenientes das lavouras situadas em suas margens. As águas desse córrego são usadas após tratamento pela população residente na área metropolitana e, são usadas sem tratamento pela população residente em suas margens. Este estudo tem como objetivo avaliar a contaminação das águas desse córrego por agrotóxicos anticolinesterásicos. Amostras de água foram coletadas mensalmente de abril/07 a fevereiro/08, em seis pontos do Córrego São Lourenço e em um ponto do Córrego das Paixões. Foram utilizadas garrafas previamente rinsadas com metanol e enxaguadas várias vezes com água destilada. A avaliação dos níveis de pesticidas se deu por método enzimático descrito por Cunha Bastos et al (1991) e pela etapa de concentração e extração dos pesticidas em coluna de carvão ativado foi adaptada a partir do método descrito por Kaipper et al. (2001), que possui a vantagem de ser um teste rápido de avaliação inicial e de baixo custo. Como controle negativo foi usado águas coletadas no ponto um, situado em área de floresta, sem terras cultivadas ao redor. Foram geradas 72 amostras, onde 33 apresentaram indícios de contaminação, mas apenas uma atingiu o limite de detecção do método, 5 ppb, em maio/07. Estes resultados, principalmente os obtidos nos pontos localizados na parte final do córrego São Lourenço, sugerem, além da utilização recente de agrotóxicos, a importância de fatores climatológicos e do regime do uso de tais compostos possivelmente interferindo na detecção dos resíduos em questão / The São Lourenço river, located in the main agriculture region of the State of Rio de Janeiro, Brazil, represents an important water supply for the Municipality of Nova Friburgo. This region is very fertile concentrating most of the vegetables production of Rio de Janeiro. The area presents an expressive rate of pesticides consumption per worker, estimated in about 56 kg/worker/year. The São Lourenço river receives all residues from the area and, with no water treatment, provides the water supply for the population living in its margins. After conventional treatment its water also supplies the metropolitan area of the City of Nova Friburgo. This study focuses its levels of contamination by pesticides. Water samples were collected, monthly, from april/07 february/08 at six points of the São Lourenço river using sterile 1 L plastic bottles previously washed with methanol and rinsed several times with distilled water. Evaluation of the pesticides levels were carried out a through an enzymatic method described by Cunha Bastos et al (1991), with presents the advantages of low cost and rapid assessment, for initial screening. Water collected at the source of the São Lourenço was used as a negative control. This spring is located at the same region but in the middle of forest with no cultivated lands around it. Concentrations of acetylcolinesterase inhibitors was found in 33 analisys, but only one apresented concentraition of inhibitors some than the method limity (5 ppb), detected in point number 3, in may/07, located in the main agriculture in the region of São Lourenço. These results, suggests that besides recent use of anticholinesterasic compounds, others factors are to be considered: climatologic factors and the regimen of use of such compounds. They are considered altogether interfering in a significant way in the detection of the residues in subject. Although the remaining water samples of the study presented values lower than possible for the enzymatic method detect, its use is highly recommended for agricultural areas, due to the need of simples and low cost routine screening methods to alert on risks for human population an environmental
|
2 |
Conservação de Água, Tratamento, reuso e Reciclo de efluentes em Refinaria de Petróleo / Water Conservation, Effluent Treatment, Reusing and Recycling at Petroleum RefineryJosé Henrique da Silva Carvalho 20 June 2006 (has links)
Nesse estudo foram analisados os principais resultados do programa de conservação de água e reuso e reciclo de efluentes aquosos em refinarias de petróleo. As principais ações empregadas visando a conservação (redução) do uso de água foram: implantação de programas de conscientização, modificações de projeto e otimização de processo. Na etapa de reuso buscou-se avaliar a compatibilidade quali e quantitativa dos efluentes aquosos com o intuito de reaproveitá-los como água reposição de outros processos industriais. Na etapa de reciclo, procurou-se melhorar a qualidade do efluente final da refinaria através de otimização da estação de tratamento de efluentes com o intuito de reaproveitá-lo no sistema de resfriamento (fechado), principal consumidor de uma refinaria. O resultado das ações de redução (conservação), reuso e reciclo foi uma redução de consumo de água de, respectivamente, 108.000, 6.100 e 130.000 m anuais. Outro resultado conseguido foi uma melhoria ambiental através da redução da vazão de efluente (80%) bem como redução da concentração dos principais contaminantes (DQO, DBO, sulfeto, óleos e graxas, sólidos suspensos, fenol e nitrogênio amoniacal). A redução do efluente após a implantação do programa foi de 80% em relação à inicial. Por fim, após análise técnico econômica do referido projeto tendo como resultado um tempo de retorno de investimento de nove meses, confirmando ser um empreendimento extremamente atrativo, demonstrando que é possível racionalizar o uso de recursos naturais, melhorar qualidade do meio ambiente e realizar bons resultados econômicos simultaneamente. / In this study the main results of water conservation and effluent reusing and recycling programs at petroleum refinery was analyzed. The main actions used to look for water conservation (reduction) were: implanting of personnel training program; plant design changes and process optimization. At reuse step the objective was to evaluate the compatibility of aqueous effluents in order to reuse it as make-up water at other industrial processes. At recycle step, the purpose was to improve the refinery effluent quality by effluent treatment station optimization in order to recycle it at cooling system, the higher water consumer at a refinery. The results of conservation, reuse and recycle actions provide the reduction of water consumption of, respectively, 108,000, 6,100 and 130,000 m3/year. Another important result was an environmental improvement by a reduction of final effluent flow rate, besides the reduction of the concentration of mainly contaminants (COD, BOD, sulphide, oils and greases, suspended solids, phenol and ammoniac nitrogen. The total reduction of effluent flow rate was 80% relative to initial status. Finally, a technical economical analysis of global program was made and showed nine months as returning rate of investment, confirming that was an extremely attractive design, proving that its possible to rationalize natural resources, improve environmental quality and gain good economic results simultaneously.
|
3 |
Conservação de Água, Tratamento, reuso e Reciclo de efluentes em Refinaria de Petróleo / Water Conservation, Effluent Treatment, Reusing and Recycling at Petroleum RefineryJosé Henrique da Silva Carvalho 20 June 2006 (has links)
Nesse estudo foram analisados os principais resultados do programa de conservação de água e reuso e reciclo de efluentes aquosos em refinarias de petróleo. As principais ações empregadas visando a conservação (redução) do uso de água foram: implantação de programas de conscientização, modificações de projeto e otimização de processo. Na etapa de reuso buscou-se avaliar a compatibilidade quali e quantitativa dos efluentes aquosos com o intuito de reaproveitá-los como água reposição de outros processos industriais. Na etapa de reciclo, procurou-se melhorar a qualidade do efluente final da refinaria através de otimização da estação de tratamento de efluentes com o intuito de reaproveitá-lo no sistema de resfriamento (fechado), principal consumidor de uma refinaria. O resultado das ações de redução (conservação), reuso e reciclo foi uma redução de consumo de água de, respectivamente, 108.000, 6.100 e 130.000 m anuais. Outro resultado conseguido foi uma melhoria ambiental através da redução da vazão de efluente (80%) bem como redução da concentração dos principais contaminantes (DQO, DBO, sulfeto, óleos e graxas, sólidos suspensos, fenol e nitrogênio amoniacal). A redução do efluente após a implantação do programa foi de 80% em relação à inicial. Por fim, após análise técnico econômica do referido projeto tendo como resultado um tempo de retorno de investimento de nove meses, confirmando ser um empreendimento extremamente atrativo, demonstrando que é possível racionalizar o uso de recursos naturais, melhorar qualidade do meio ambiente e realizar bons resultados econômicos simultaneamente. / In this study the main results of water conservation and effluent reusing and recycling programs at petroleum refinery was analyzed. The main actions used to look for water conservation (reduction) were: implanting of personnel training program; plant design changes and process optimization. At reuse step the objective was to evaluate the compatibility of aqueous effluents in order to reuse it as make-up water at other industrial processes. At recycle step, the purpose was to improve the refinery effluent quality by effluent treatment station optimization in order to recycle it at cooling system, the higher water consumer at a refinery. The results of conservation, reuse and recycle actions provide the reduction of water consumption of, respectively, 108,000, 6,100 and 130,000 m3/year. Another important result was an environmental improvement by a reduction of final effluent flow rate, besides the reduction of the concentration of mainly contaminants (COD, BOD, sulphide, oils and greases, suspended solids, phenol and ammoniac nitrogen. The total reduction of effluent flow rate was 80% relative to initial status. Finally, a technical economical analysis of global program was made and showed nine months as returning rate of investment, confirming that was an extremely attractive design, proving that its possible to rationalize natural resources, improve environmental quality and gain good economic results simultaneously.
|
4 |
Análise da contaminação das águas do córrego São Lourenço (Nova Friburgo, RJ) por agrotóxicos organofosforados e carbamatos / Contamination analisys of São Lourenço river water (Nova Friburgo/RJ) by organophosphorade a carbamate pesticidesAndré Ribeiro Silva de Almeida 30 June 2008 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / O córrego de São Lourenço (Nova Friburgo RJ), situado na principal região agrícola do estado, representa um importante manancial hídrico do município de Nova Friburgo que percorre um vale onde se concentram as principais lavouras responsáveis pela produção de olerícolas do Estado. Esta localidade apresenta expressiva relação de consumo de agrotóxicos por trabalhador (56 kg/trabalhador/ano). Assim, este córrego recebe todos os resíduos provenientes das lavouras situadas em suas margens. As águas desse córrego são usadas após tratamento pela população residente na área metropolitana e, são usadas sem tratamento pela população residente em suas margens. Este estudo tem como objetivo avaliar a contaminação das águas desse córrego por agrotóxicos anticolinesterásicos. Amostras de água foram coletadas mensalmente de abril/07 a fevereiro/08, em seis pontos do Córrego São Lourenço e em um ponto do Córrego das Paixões. Foram utilizadas garrafas previamente rinsadas com metanol e enxaguadas várias vezes com água destilada. A avaliação dos níveis de pesticidas se deu por método enzimático descrito por Cunha Bastos et al (1991) e pela etapa de concentração e extração dos pesticidas em coluna de carvão ativado foi adaptada a partir do método descrito por Kaipper et al. (2001), que possui a vantagem de ser um teste rápido de avaliação inicial e de baixo custo. Como controle negativo foi usado águas coletadas no ponto um, situado em área de floresta, sem terras cultivadas ao redor. Foram geradas 72 amostras, onde 33 apresentaram indícios de contaminação, mas apenas uma atingiu o limite de detecção do método, 5 ppb, em maio/07. Estes resultados, principalmente os obtidos nos pontos localizados na parte final do córrego São Lourenço, sugerem, além da utilização recente de agrotóxicos, a importância de fatores climatológicos e do regime do uso de tais compostos possivelmente interferindo na detecção dos resíduos em questão / The São Lourenço river, located in the main agriculture region of the State of Rio de Janeiro, Brazil, represents an important water supply for the Municipality of Nova Friburgo. This region is very fertile concentrating most of the vegetables production of Rio de Janeiro. The area presents an expressive rate of pesticides consumption per worker, estimated in about 56 kg/worker/year. The São Lourenço river receives all residues from the area and, with no water treatment, provides the water supply for the population living in its margins. After conventional treatment its water also supplies the metropolitan area of the City of Nova Friburgo. This study focuses its levels of contamination by pesticides. Water samples were collected, monthly, from april/07 february/08 at six points of the São Lourenço river using sterile 1 L plastic bottles previously washed with methanol and rinsed several times with distilled water. Evaluation of the pesticides levels were carried out a through an enzymatic method described by Cunha Bastos et al (1991), with presents the advantages of low cost and rapid assessment, for initial screening. Water collected at the source of the São Lourenço was used as a negative control. This spring is located at the same region but in the middle of forest with no cultivated lands around it. Concentrations of acetylcolinesterase inhibitors was found in 33 analisys, but only one apresented concentraition of inhibitors some than the method limity (5 ppb), detected in point number 3, in may/07, located in the main agriculture in the region of São Lourenço. These results, suggests that besides recent use of anticholinesterasic compounds, others factors are to be considered: climatologic factors and the regimen of use of such compounds. They are considered altogether interfering in a significant way in the detection of the residues in subject. Although the remaining water samples of the study presented values lower than possible for the enzymatic method detect, its use is highly recommended for agricultural areas, due to the need of simples and low cost routine screening methods to alert on risks for human population an environmental
|
5 |
Desenvolvimento, implementaÃÃo e avaliaÃÃo de uma estaÃÃo agrohidrometeorolÃgica automÃtica e sensores ambientais / Development, implementation and evaluation of an automatic agrohidrometeorolÃgica station and environmental sensorsFrancisco Josà Firmino Canafistula 30 September 2013 (has links)
O acesso ao recurso hÃdrico gera conflitos em todas as regiÃes do mundo. Com o aumento do consumo e da escassez da Ãgua, a tendÃncia à aumentar a inseguranÃa hÃdrica e os conflitos. Por conseguinte, à fundamental e necessÃria a geraÃÃo de ferramentas, instrumentos e metodologias de mediÃÃo que aumentem a consistÃncia dos estudos e a eficiÃncia do gerenciamento desse recurso. O desenvolvimento tecnolÃgico de um sistema de coleta automÃtica e armazenamento de dados meteorolÃgicos e hidrolÃgicos à apresentado neste trabalho. O trabalho tambÃm descreve o desenvolvimento, metodologia de calibraÃÃo, instalaÃÃo e avaliaÃÃo do funcionamento em campo experimental de sensores com caracterÃsticas especiais. O foco do desenvolvimento e avaliaÃÃo dos sensores à para atender Ãs incertezas das variaÃÃes espaÃo temporal de dados meteorolÃgicos e hidrolÃgicos do semiÃrido nordestino. Buscou-se na tecnologia de microcontroladores o desenvolvimento do sistema de aquisiÃÃo de dados, em decorrÃncia da gama de arquiteturas disponÃveis a baixo custo. Parte dos sensores desenvolvidos vem da tecnologia de transdutores industriais com base em semicondutores. A dimensÃo do valor da constante dielÃtrica da Ãgua, aliada ao modelo de funcionamento dos capacitores produziu tambÃm transdutores presentes neste trabalho. Foi possÃvel fazer a mediÃÃo e o armazenamento de dados ambientais de microbacias presentes no semiÃrido e assim apresentar a relaÃÃo entre eventos meteorolÃgicos (medidas pluviomÃtricas) e hidrolÃgicos (vazÃo de cursos de 1 ordem no (picos de descarga) semiÃrido. Umidade relativa do ar, temperatura do ar, temperatura do solo e umidade do solo tambÃm tiveram seus valores monitorados pelas sondas desenvolvidas. Testar os instrumentos à necessÃrio, pois permite aperfeiÃoar a precisÃo e a robustez do sistema. Os dados obtidos pelo sistema permitiram a construÃÃo de hidrogramas das microbacias. O canal de comunicaÃÃo dos sistema foi eficiente na coleta de dados, entretanto, faz-se necessÃrio estabelecer vias alternativas de conectividade, para obter uma melhor avaliaÃÃo e manutenÃÃo do sistema. A investigaÃÃo de desempenho do pluviÃmetro capacitivo automÃtico no laboratÃrio e em campo demonstrou a capacidade do instrumento em medir todos os parÃmetros da precipitaÃÃo pluvial. Eventos com 0,7 mm de lÃmina podem ser mensurados, inclusive a intensidade da precipitaÃÃo. / Access to water resources creates conflicts in all regions of the world. With the increase in consumption and water scarcity, the tendency is to increase water insecurity and conflict, therefore it is essential and necessary to develop tools, instruments and measurement methodologies that increase the efficiency and consistency of studies of the management of this resource. The technological development of a system for automatic collection and storage of meteorological and hydrological data is presented in this thesis. The text also describes the development, methodology, calibration, installation and evaluation of operation, in the experimental field, of sensors with special features. The focus of the development and evaluation of the sensors is to meet the uncertainties of changing space-time weather data from the semi-arid Northeast. Sought in the microcontroller technology development system of data acquisition, because its range of architectures and the low costs. Part of the sensors has developed technology on based industrial transducers and semiconductors. The range of the value of the dielectric constant of water, coupled with the operating model of the capacitors also produced transducers in this work. It was possible to make the measurement and storage of environmental data from these micro-watersheds in the semiarid and thus present the relationship between weather events (rainfall) and hydrological (flow of courses in a second order semi-arid region). Relative humidity, air temperature, soil temperature and soil moisture values were also monitored by the probes developed. Test instruments is necessary because it allows improving the accuracy and robustness of the data obtained by the system. The system has allowed to the construction of hydrographs of micro-basins. The communication channel of the system was efficient in data collection, however, it is necessary to establish alternative means of connectivity for better evaluation and system maintenance. Research on performance of capacitive automatic rain gauge in laboratory and field demonstrated the ability of the instrument to measure all parameters of rainfall. Events with in 0.7 mm range can be measured, including rainfall intensity
|
6 |
Desenvolvimento de medidor de vazão de gás por ultra-som : modelagem, protótipo e testesRamos, Rodrigo 14 December 2006 (has links)
Made available in DSpace on 2016-12-23T14:08:13Z (GMT). No. of bitstreams: 1
Dissertacao de Rodrigo Ramos.pdf: 1546367 bytes, checksum: d9dd7667fd9e6d0f4d87e3b238a29764 (MD5)
Previous issue date: 2006-12-14 / The use of transit time ultrasonic flow measurement technique has
increased very quickly in the last years, so that it is urgently
necessary to develop Brazilian technology in this instrumentation field. This work presents the development of a transit time flow meter prototype, called MEVUS, devoted to measurement of gas flows. It presents the mathematical modeling of the governing physical process of the interaction between the ultrasonic wave and the flow that one wants to measure, which is supposed completely developed in a circular pipe. It also presents a systematization of the uncertainty analysis related to the measurement process. The process of conception, analysis and design of the prototype is equally described, so that the reader can easily understand the problems found during the development, highlighting the proposed solutions and the feedback of the creation process of MEVUS Medidor de Vazão por Ultra-Som (Ultrasonic Flowmeter). Performance tests were conducted in the Flow Machines Laboratory of the Mechanical Engineering Department UFES. They are clearly described. The conclusions are presented, as well as the suggestions for future works / A medição ultra-sônica por tempo de trânsito vem alargando
velozmente seu campo de aplicação nos últimos anos, havendo, sem dúvida, a necessidade urgente de desenvolvimento de tecnologia brasileira neste campo da instrumentação. O trabalho apresenta o desenvolvimento de um protótipo, batizado de MEVUS, para medidor de vazão ultra-sônico por tempo de trânsito voltado à medição de vazão de gás. Desenvolve-se a modelagem matemática do processo físico que governa a interação entre a onda ultra-sônica e o escoamento que se deseja medir, o qual se supõe plenamente desenvolvido numa tubulação circular. Apresenta-se também a sistematização da análise de incertezas. O processo de concepção, análise e projeto do protótipo é igualmente descrito, permitindo ao leitor a compreensão dos desafios enfrentados durante as atividades, destacando as soluções propostas e realimentação do processo de desenvolvimento do MEVUS Medidor de Vazão por Ultra-Som. Os testes preliminares de desempenho conduzidos no Laboratório de Máquinas de Fluxo do departamento de Engenharia Mecânica UFES são claramente descritos, apresentando-se as conclusões e as sugestões de trabalhos futuros
|
7 |
Implementação de um quadrotor como plataforma de desenvolvimento para algoritmos de controleMelo, Alexandre Secchin de 30 June 2010 (has links)
Made available in DSpace on 2016-12-23T14:07:26Z (GMT). No. of bitstreams: 1
Alexandre Secchin de Melo - parte 1.pdf: 1376671 bytes, checksum: 7504ac977143d6adfd9ac0c7c2bc0d2f (MD5)
Previous issue date: 2010-06-30 / Este trabalho visa a implementação de um objeto voador não-tripulado, em formato miniatura, com quatro rotores como plataforma de desenvolvimento, como parte de uma pesquisa mais abrangente. O objetivo final, ainda por ser alcançado, é chegar a um veículo voador miniatura com o máximo grau de autonomia de decisões baseadas no sensoreamento a bordo e poder computacional embarcados, estratégia do controle inteligente, e tarefa a cumprir. Tal implemetação, até o momento, consiste em uma máquina eletro-mecânica de baixo custo, cuja parte eletrônica a bordo, um microcontrolador de 8 bits, acelerômetros e giroscópios do tipo MEMS, permite a implementação de um controlador de voo genérico para automatizar a sua estabilização em torno dos eixos X, Y e Z. Tem vasta gama de aplicações como: inspeções aéreas em diversos ambientes, como linhas de transmissão elétrica, detecção de foragidos da polícia, monitoramento de plantações e rebanhos, bem como tomadas de filmagens para as indústrias cinematográfica e imobiliária. Testes realizados com o protótipo até agora sugerem a implementação bem sucedida de um controlador de estabilização de voo / This work aims the implementation of a unmanned, four-rotor miniature flying machine as a development platform, part of a long term research. The final goal, yet to be achieved, is the realization of a flying object with maximum practicable degree of autonomous decisions based on the on-board sensory and computational power, control strategy and assigned task. Up to this work, it consists of a low cost electro-mechanical hardware, whose electronic part allows the implementation of an 8-bit microcontroller-based, MEMS accelerometer and gyroscopes, allows the implementation of a generic fly control for attitude stabilization. The broad spectrum of applications includes: the inspection of various kinds of environments such as electric power transmission lines, police surveillance of woods and hard-to-reach places with sky sight for fugitive detection, crops and herd monitoring, as well as film takings for the cinematographic and real estate industries. Tests undertaking so far with the prototype suggest the successful implementation of a fly attitude controller
|
8 |
[en] METROLOGICAL RELIABILITY OF OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICAL APPLICATIONS / [pt] CONFIABILIDADE METROLÓGICA DA TOMOGRAFIA POR COERÊNCIA ÓPTICA EM APLICAÇÕES BIOMÉDICASCAROLINA MOREIRA GOLONI MARQUES 14 April 2014 (has links)
[pt] A Tomografia por Coerência Óptica (OCT) vem sendo utilizada desde a década de 1990 em diversas áreas do campo biomédico, uma biópsia óptica com importantes perspectivas como ferramenta diagnóstica para caracterização quantitativa de estruturas teciduais.No presente trabalho é realizado estudo dos parâmetros para avaliação de conformidade dos equipamentos optoeletrônicos para aplicação biomédica como Laser, IPL(Luz Pulsada Intensa) e OCT, objetivando a identificação dos itens cuja avaliação é necessária como requisito em futura norma específica para equipamentos de Tomografia por Coerência Óptica. Além dos parâmetros metrológicos requeridos na norma particular para equipamentos a Laser, e alguns dos parâmetros da norma para IPL, foram identificados outros parâmetros metrológicos específicos para avaliação de equipamentos de OCT, considerando sua aplicação biomédica, como comprimento de coerência, resolução axial e resolução transversal. Considerando a possibilidade de elaboração futura de norma específica para OCT, para alguns dos parâmetros identificados, recomendou-se o requisito de medição e, para outros, somente a inclusão da informação nos documentos acompanhantes. Dentre os parâmetros cujo requisito de medição foi recomendado para equipamentos de OCT são: potência da emissão eletromagnética, comprimento de onda central, concentricidade entre os feixes de trabalho e de mira, diâmetro e divergência do feixe de trabalho, duração de um pulso, número de pulsos em um trem de pulsos e irradiância espectral. / [en] Optical Coherence Tomography has been proving to be an efficient diagnostics technique for imaging in vivo tissues, an optical biopsy with important perspectives as a diagnostics tool for quantitative characterization of tissue structures.The present work studies the parameters conformity evaluation of optoelectronics equipment for biomedical applications like Laser, IPL (Intense Pulsed Light), and OCT, targeting the identification of items which are necessary as a requirement to develop a future specific standard for Optical Coherence Tomography equipments. Beside the metrological parameters required by the particular standard for Laser and IPL equipment, specific parameters necessary for OCT’s evaluation have been identified, regarding its biomedical application. For some parameters identified,
measurement requisite has been recommended, and for others, only the information on the accompanying documents. Among the parameters required for measurement, highlights for: electromagnetic emission power, measurement uncertainty of incident power, coherence length, work beam diameter and divergence, pulse duration and spectral irradiance.
|
9 |
[en] BEHAVIOUR OF AN EXPERIMENTAL LANDFILL OVER A GOLD TAILINGS DEPOSIT PARACATU MINING CO / [pt] COMPORTAMENTO DE UM ATERRO EXPERIMENTAL SOBRE UM DEPÓSITO DE REJEITOS DE OURO: MINERAÇÃO PARACATUGERMAN LUIS GONZALES MAMANI 05 September 2013 (has links)
[pt] Em projetos de barragens de rejeitos de mineração, normalmente existe uma
grande preocupação relacionada aos aspectos construtivos e de segurança, em
função do processo de lançamento de material sobre depósitos fofos de rejeitos
saturados. Os maiores desafios consistem na avaliação da resistência e da
deformabilidade do material de fundação, na possibilidade de ocorrência de
liquefação, e no desenvolvimento e velocidade de dissipação das poropressões.
Neste contexto, a Rio Paracatu Mineração (RPM) construiu um aterro
experimental instrumentado em grande escala,com material de empréstimo
siltoarenoso sobre o depósito de rejeito na Mina do Ouro. Este aterro
experimental foi projetado e construído com 10,0 m de altura, talude frontal de
1,5H:1,0V e um talude suave com uma berma de estabilização de 4,0 m de altura
no talude oposto. A fundação do aterro foi instrumentada com piezômetros
elétricos de corda vibrante, inclinômetros e placas de recalque. Além da
instrumentação de campo, há uma base de dados de ensaios de laboratório
realizados nas universidades de Viçosa (UFV), São Carlos (USP/SC) e PUC-Rio.
Todos estes dados permitem a caracterização do material do rejeito, além da
determinação de parâmetros de resistência, deformabilidade, permeabilidade e
adensamento. O objetivo desta Tese é contribuir para uma melhor compreensão
do comportamento de barragens de rejeitos de mineração com base nas evidências
laboratoriais e na retroanálise do comportamento do aterro experimental de larga
escala. Para tanto, foi realizada a simulação numérica do processo construtivo do
aterro experimental, buscando-se o modelo constitutivo e os parâmetros mais
adequados para a representação do comportamento de solos granulares saturados.
As análises numéricas foram executadas com o programa computacional Plaxis V11, de elementos finitos. Uma vez reproduzido o comportamento do aterro
experimental, procedeu-se à previsão dos recalques e deslocamentos horizontais
da barragem de ouro da Rio Paracatu Mineração. Os resultados mostraram que o
modelo Hardening Soil permitiu a reprodução do comportamento do aterro
experimental durante as etapas construtivas. A boa seleção de parâmetros, com
base em um extenso programa experimental, permitiu a previsão do
comportamento da barragem principal. / [en] In projects of mining tailings dams, there is usually a big concern and
constructive aspects related to security, according to the release process of
material on saturated tailings deposits cute. The biggest challenges consist in
evaluating the strength and deformability of the foundation material, the
possibility of liquefaction and speed the development and dissipation of
poropressures. In this context, the Rio Paracatu Mineração (RPM) built an
instrumented experimental landfill on a large scale, with sandy silty material loan
on the deposit of waste in the Gold Mine. This experimental landfill was designed
and constructed with 10.0 m height, front slope of 1.5 H: 1.0 V and a gentle slope
with a stabilizing berm of 4.0 m high on the slope opposite. The foundation of the
embankment was instrumented with vibrating string electric piezometers,
inclinometers and settlement plates. Besides the instrumentation field, there is a
database of laboratory tests conducted at the Universities of Viçosa (UFV), San
Carlos (USP / SC) and PUC-Rio. All these data allow the characterization of
tailings material, besides the determination of parameters of resistance,
deformability, permeability and density. The goal of this dissertation is to
contribute to a better understanding of the behavior of mining tailings dams based
on laboratory evidence and backcalculation behavior of large-scale experimental
landfill. Therefore, we performed a numerical simulation of the construction
process of the experimental landfill, seeking the constitutive model and
parameters best suited to represent the behavior of granular soils saturated. The
numerical analyzes were performed with the computer program Plaxis V11, finite
elements. Once reproduced the experimental behavior of the landfill, proceeded to
the prediction of settlements and horizontal displacements of the dam the Rio
Paracatu gold mining. The results showed that the model Hardening Soil allowed
playback behavior of the experimental landfill during the construction stages. A good selection of parameters based on an extensive experimental program allowed
the prediction of the behavior of the main dam.
|
10 |
[en] BEHAVIOUR OF A NAILED EXCAVATION IN GNEISSIC RESIDUAL SOIL / [pt] COMPORTAMENTO DE UMA ESCAVAÇÃO GRAMPEADA EM SOLO RESIDUAL DE GNAISSEANDRE PEREIRA LIMA 04 December 2007 (has links)
[pt] O comportamento de uma escavação grampeada em solo
residual de
gnaisse foi avaliado por um programa de monitoramento
geotécnico do maciço
reforçado. Diversas obras estão sendo realizadas no país,
sem conhecimentos
detalhados sobre as deformações inerentes à técnica e
sobre os mecanismos de
interação solo-grampo. No Brasil, menos de 10% das obras
de solo grampeado
utilizaram algum tipo de instrumentação. Esta pesquisa
teve por objetivo a
análise de uma escavação em solo residual reforçada com
grampos. A
escavação foi instrumentada para o monitoramento dos
deslocamentos do
maciço e dos esforços nos grampos. Um extenso programa
experimental de
ensaios de campo e laboratório foi executado para fornecer
os parâmetros
geotécnicos utilizados nas análises computacionais. A
escavação grampeada
teve cerca de 40m de altura, constituindo uma experiência
inédita no país e
talvez no mundo. Devido a esta altura, os grampos
superiores foram instalados
com comprimentos de até 24m. O comportamento do talude foi
influenciado pelo
processo executivo e por uma outra escavação no terreno
vizinho. O
monitoramento indicou que os deslocamentos do maciço e os
esforços nos
grampos cresceram significativamente com o avanço da
escavação e não
cessaram ao final da obra. Os grampos trabalharam
predominantemente à
tração, com momentos fletores pouco significativos. Os
valores de tração
estimados na fase de projeto diferiram dos resultados
obtidos na instrumentação.
A distribuição dos esforços de tração foi influenciada
pelas características
geológicas do maciço. A tração máxima (Tmáx) teve uma
posição variando com a
profundidade e a inclinação do talude, e uma magnitude
aumentando
exponencialmente com o avanço da escavação. A tração na
face (To) foi de 0,3 a
0,6 de Tmáx. A resistência mobilizada no contacto solo-
grampo não ultrapassou
35% do valor de qs medido nos ensaios de campo. / [en] The behavior of a nailed excavation in gneissic residual
soil has been
studied by a comprehensive research program, including
instrumentation, field
and laboratory tests and numerical analyses. Soil nailing
is becoming a popular
stabilization technique in Brazil. However, a solid
knowledge about the soil-nail
interaction is still lacking. There are a few studies
about the inherent
deformations of the reinforced mass and the magnitude of
nail`s stresses. In
Brazil, less than 10% of stabilization works have some
type of instrumentation.
The main objective of this research was monitoring and
analysing a 40m high soil
nailed slope excavation.
Due to this unique height, the upper nails were installed
with 24m length.
The slope behavior was influenced by several factors, such
as the construction
technique and a subsequent excavation at one adjacent
site. The results
indicated a significant increase of reinforced mass
displacements and of the nail s
mobilized tension during the progress of the excavation.
These did not cease
after the end of the excavation, due to the adjacent work.
During and after
construction, the nails worked predominantly in tension.
Estimated tension loads
in the project phase were compared with the
instrumentation s results. The stress
distribution was influenced by local geology. The maximum
axial force (Tmáx)
increased exponentially with the progress of the
excavation and its position, in
each nail, varies with the slope s depth and inclination.
The magnitude of the
axial load in the excavation face is observed to be
between 0,3 and 0,6 of Tmáx.
The mobilization of the reinforcement elements was smaller
than 35% qs.
|
Page generated in 0.0967 seconds