• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Metodologia de controle de qualidade e implantação de campos padrões de radiação X, nível  mamografia, seguindo a norma IEC 61267 / Quality control methodology and implementation of X-radiation standards beams, mammography level, following the standard IEC 61267

Corrêa, Eduardo de Lima 24 November 2010 (has links)
Neste trabalho foi desenvolvido e aplicado um programa de controle de qualidade ao equipamento de raios X (160 kV, potencial constante, alvo de tungstênio) do Laboratório de Calibração de Instrumentos (LCI) do IPEN no intervalo de energia relativo aos feixes de mamografia (de 25 a 35 kV). Depois da aplicação deste programa foram implantados os campos padrões de radiação X, nível mamografia, utilizando filtração adicional de molibdênio e alumínio, seguindo recomendações nacionais e internacionais, neste mesmo equipamento. A câmara de ionização de referência possui rastreabilidade ao PTB e foi submetida rotineiramente a testes de controle de qualidade para avaliação e análise da confiabilidade de seu desempenho. Foram implantadas qualidades relativas aos feixes de entrada (RQR-M), feixes de saída (RQA-M), feixes estreitos (RQN-M) e feixes largos (RQB-M), seguindo as recomendações da nova norma internacional IEC 61267, de 2005 e do novo código de pratica da AIEA, TRS 457 (2007). Para a implantação dos feixes RQN-M e RQB-M foram desenvolvidos dois simuladores específicos para mamografia. As camadas semi-redutoras encontradas são aquelas apresentadas pelo laboratório primário alemão PTB, e variaram de 0,35 até 1,21 mmAl. As taxas de kerma no ar foram determinadas para todas as 15 qualidades implantadas. / In this work it was developed and applied a quality control program of the Xradiation system (160 kV, constant potential, target of tungsten) of the Calibration Laboratory of IPEN(LCI) in the energy range relative to mammography beams (from 25 kV to 35 kV). The X radiation standards beams, level mammography, using molybdenum and aluminum as additional filtration, were established after the application of this quality control program following national and international recommendations. The reference ionization chamber has traceability to PTB and was regularly submitted to quality control tests for evaluation and analysis of its performance. The radiation qualities emerging from the X-radiation assembly (RQR-M), based on a phantom made up of an aluminum added filter (RQA-M), narrow beam condition (RQN-M) and broad beam condition (RQB-M), following the recommendations of the international standard IEC 61267 (2005) and the IAEA code of practice, TRS 457 (2007) were established. For the implantation of RQN-M and RQB-M radiation qualities, two mammography phantoms were developed. The half-value layers found are those presented by the German primary laboratory PTB, and varied from 0.35 to 1.21 mmAl. The air kerma rates were obtained for all the 15 implanted qualities.
2

Metodologia de controle de qualidade e implantação de campos padrões de radiação X, nível  mamografia, seguindo a norma IEC 61267 / Quality control methodology and implementation of X-radiation standards beams, mammography level, following the standard IEC 61267

Eduardo de Lima Corrêa 24 November 2010 (has links)
Neste trabalho foi desenvolvido e aplicado um programa de controle de qualidade ao equipamento de raios X (160 kV, potencial constante, alvo de tungstênio) do Laboratório de Calibração de Instrumentos (LCI) do IPEN no intervalo de energia relativo aos feixes de mamografia (de 25 a 35 kV). Depois da aplicação deste programa foram implantados os campos padrões de radiação X, nível mamografia, utilizando filtração adicional de molibdênio e alumínio, seguindo recomendações nacionais e internacionais, neste mesmo equipamento. A câmara de ionização de referência possui rastreabilidade ao PTB e foi submetida rotineiramente a testes de controle de qualidade para avaliação e análise da confiabilidade de seu desempenho. Foram implantadas qualidades relativas aos feixes de entrada (RQR-M), feixes de saída (RQA-M), feixes estreitos (RQN-M) e feixes largos (RQB-M), seguindo as recomendações da nova norma internacional IEC 61267, de 2005 e do novo código de pratica da AIEA, TRS 457 (2007). Para a implantação dos feixes RQN-M e RQB-M foram desenvolvidos dois simuladores específicos para mamografia. As camadas semi-redutoras encontradas são aquelas apresentadas pelo laboratório primário alemão PTB, e variaram de 0,35 até 1,21 mmAl. As taxas de kerma no ar foram determinadas para todas as 15 qualidades implantadas. / In this work it was developed and applied a quality control program of the Xradiation system (160 kV, constant potential, target of tungsten) of the Calibration Laboratory of IPEN(LCI) in the energy range relative to mammography beams (from 25 kV to 35 kV). The X radiation standards beams, level mammography, using molybdenum and aluminum as additional filtration, were established after the application of this quality control program following national and international recommendations. The reference ionization chamber has traceability to PTB and was regularly submitted to quality control tests for evaluation and analysis of its performance. The radiation qualities emerging from the X-radiation assembly (RQR-M), based on a phantom made up of an aluminum added filter (RQA-M), narrow beam condition (RQN-M) and broad beam condition (RQB-M), following the recommendations of the international standard IEC 61267 (2005) and the IAEA code of practice, TRS 457 (2007) were established. For the implantation of RQN-M and RQB-M radiation qualities, two mammography phantoms were developed. The half-value layers found are those presented by the German primary laboratory PTB, and varied from 0.35 to 1.21 mmAl. The air kerma rates were obtained for all the 15 implanted qualities.
3

Modelo causal para análise probabilística de risco de falhas de motores a jato em situação operacional de fabricação

Pereira, José Cristiano 27 July 2017 (has links)
Submitted by Secretaria Pós de Produção (tpp@vm.uff.br) on 2017-07-27T19:21:56Z No. of bitstreams: 1 D2014 - José Cristiano Pereira.pdf: 9830334 bytes, checksum: d5be51799514c74451d0ca3358d7757b (MD5) / Made available in DSpace on 2017-07-27T19:21:56Z (GMT). No. of bitstreams: 1 D2014 - José Cristiano Pereira.pdf: 9830334 bytes, checksum: d5be51799514c74451d0ca3358d7757b (MD5) / O processo de fabricação de motores a jato é complexo. Perigos e riscos e muitos elementos críticos estão presentes em milhares de atividades necessárias para fabricar um motor. Na investigação realizada nota-se a inexistência de um modelo específico para calcular quantitativamente a probabilidade de falha operacional de um motor à jato. O objetivo da tese foi desenvolver um modelo causal para análise de risco probabilística de falhas de motores a jato em situação operacional de fabricação. O modelo se caracteriza pela aplicação de rede Bayesiana associada à árvore de falha / árvore de evento e elicitação de probabilidades por especialistas para quantificar a probabilidade de falha. Para a concepção da construção do modelo, foi inicialmente desenvolvida uma pesquisa bibliométrica, através da consulta aos principais motores de busca nacionais e internacionais, em periódicos científicos e técnicos, bancos de dissertações/teses e eventos técnicos relacionados ao tema, para estabelecimento dos estado-da-arte e da técnica. Para a estimativa das probabilidades associadas aos cenários de falhas propostos, foi desenvolvido um processo de elicitação de probabilidade a partir da consulta a especialistas e técnicos. Na concepção do modelo foram consideradas três áreas de influência para a confiabilidade do sistema: humana, software e calibração. Como resultado foi desenvolvido o modelo CAPEMO, que é suportado por um aplicativo que utiliza a teoria das probabilidades (Lei de Bayes) para modelar incerteza. A probabilidade de falha estimada ao final da processo de fabricação, antes do motor ser colocado em operação, contribui no processo de tomada de decisão, melhoria da segurança do sistema e redução de riscos de falha do motor em operação / The process of jet engines manufacturing is complex. Hazards and risks and many critical elements are present in the thousands of activities required to manufacture an engine. In the conducted investigation it is observed a lack of a specific model to estimate quantitatively the probability of a jet engine operational failure. The goal of this thesis is to develop a causal model for probabilistic risk analysis of jet engines failure in manufacturing situational operation. The model is characterized by the application of Bayesian Network associated with the fault tree and event tree to quantify the probability of failure. For the establishment of state-of-the-art and technique and for the conception and construction of the model, a bibliometric research was conducted in the main national and international search engines, in the scientific and technical journals, in the database of dissertations/theses and technical events related to the topic. For the estimation of the probabilities associated with the proposed fault scenarios, a process of probability elicitation from technicians and experts was developed. In the design of the model three areas of influence for the reliability of the system were considered: human, software and calibration. As a result CAPEMO model was developed, that is supported by a software application that uses probability theory to model uncertainty. The probability of engine failure estimated at the end of the manufacturing process, before the motor be put into operation, helps in the allocation of resources in the decision-making process and improves system safety reducing the risk of engine failure in operation

Page generated in 0.2061 seconds