• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Respostas fisiológicas durante o exercício intervalado realizado no ciclismo com recuperação passiva e ativa /

Barbosa, Luis Fabiano. January 2009 (has links)
Orientador: Camila Coelho Greco / Banca: Fabrizio Caputo / Banca: Sarah Regina Dias da Silva / Resumo: O objetivo deste estudo foi verificar a validade da máxima fase estável de lactato (MLSS) como fronteira entre o domínio pesado e severo, analisar o efeito do tempo para análise cinética da concentração de lactato sanguíneo ([La]) sobre a (MLSSw) e a [La] correspondentes a MLSS em exercícios intermitentes (MLSSi) com recuperação passiva e ativa e, verificar a influência da recuperação passiva ou ativa na [La], MLSSw, freqüência cardíaca (FC) e intensidade relativa à potência máxima (%Wmax) correspondentes à MLSS. Dezenove ciclistas treinados do gênero masculino divididos em dois grupos, recuperação passiva (VO2max = 3960,6 ± 312,8 ml.min-1; N = 9) ou ativa (VO2max = 3958,3 ± 318,3 ml.min-1; N = 10), realizaram os seguintes testes, em dias diferentes, em um cicloergômetro: 1) Teste incremental até a exaustão; 2) 2 a 3 testes de carga contínua para a determinação da MLSS de forma contínua (MLSSc) e; 3) testes intermitentes de carga submáxima (8 x 4 min, com 2 min de recuperação passiva ou ativa) para determinar a MLSSi com recuperação passiva (MLSSip) e ativa (MLSSia). A MLSSi foi definida como a mais alta carga na qual a [La] não aumentou mais do que 1 mM entre o 10o e o 30o min (critério 1 - C1) ou 14o e 44o min (critério 2 - C2) do protocolo. Os valores do VO2 obtidos no 30o min de exercício foi estatisticamente maior que o valor obtido no 3o min de exercício a 100%MLSSc (3379,3 ± 250,1 ml/min vs. 3496,7 ± 280,2 ml/min, p<0,05) e a 105%MLSSc (3439,5 ± 289,3 ml/min vs. 3545,5 ± 303,2 ml/min, p<0,05), sendo estes valores significantemente menores do que o VO2pico (3978,6 ± 296,2 ml/min, p>0,05). O tempo (C1 ou C2) parece não influenciar significantemente a [La] (Passiva - 5,89 ± 1,41 mM vs. 5,61 ± 1,78 mM; Ativa - 5,62 ± 1,83 mM vs. 4,91 ± 1,91 mM) e a MLSSw (Passiva - 294,5 ± 31,8 W vs. 294,7 ± 32,2 W; Ativa... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to analyze the validity of the maximal lactate state (MLSS) as a boundary between heavy and severe domain, to check the effect of time for the analysis of blood lactate concentration ([La]) kinetics on workload (MLSSw) and related to MLSS during intermittent exercises (MLSSi) with passive and active recovery and to verify the influence of passive or active recovery at [La], MLSSw, heart rate and relative intensity of Wmax (%Wmax) correspondent to maximal lactate steady state. Nineteen male trained cyclists were divided into two groups: passive recovery (VO2max = 3960,6 ± 312,8 ml.min-1; N = 9) and active (VO2max = 3958,3 ± 318,3 ml.min-1; N = 10), they performed the following tests, in different days, on a cycle ergometer: 1) Incremental test until exhaustion and; 2) 2 to 3 constants workload tests to determine (MLSSc) and; 3) intermittent submaximal workload tests (8 x 4 min, with 2 min of passive or active recovery) to determine MLSSi with passive recovery (MLSSip) and active (MLSSia). MLSSi was defined as the highest workload at which [La] increased no more than 1 mM between 10th and 30th min (criterion 1 - C1) or 14o and 44o min (criterion 2 - C2) of the protocol. VO2 values obtained at 30th min was statistically higher than that obtained at 3rd min of the exercise performed at 100%MLSS (3379.3 ± 250.1 vs. 3496.7 ± 280.2 ml/min, p<0.05) and 105%MLSS (3439.5 ± 289.3 vs. 3545.5 ± 303.2 ml/min, p<0.05) and the VO2 value obtained at 30th min of the exercise performed at 100%MLSS and 105%MLSS was statistically lower than VO2peak (3978.6 ± 296.2 ml/min, p>0.05). Time (C1 or C2) seems not influence significantly [La] (Passive - 5,89 ± 1,41 mM vs. 5,61 ± 1,78 mM; Active- 5,62 ± 1,83 mM vs. 4,91 ± 1,91 mM) and MLSSw ((Passive - 294.5 ± 31.8 vs. 294.7 ± 32.2 W; Active - 304.6 ± 23.0 vs. 300.5 ± 23.9 W). Interruptions at exercise... (Complete abstract click electronic access below) / Mestre

Page generated in 0.1319 seconds