• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Herstellung und Charakterisierung von SiC-Faser-verstärktem Kupfer zur Anwendung in Hochleistungswärmesenken / Manufacturing and characterisation of SiC-fibre-reinforced copper in heat sink applications

Kimmig, Stefan January 2013 (has links) (PDF)
Die Wandmaterialien innerhalb des Plasmagefäßes zukünftiger Fusionsreaktoren sind teilweise extremen thermischen und mechanischen Belastungen ausgesetzt. Der thermisch höchstbelastete Bereich der Wand des Torusgefäßes ist der Divertor. Hier werden die anfallende Fusionsasche (Helium) und erodierte Wandpartikel aus dem Plasma entfernt, wodurch aufgrund erhöhter Teilchen-Wand-Interaktion Wärmeflüsse von bis zu 15 MW/m² erreicht werden. Wolfram gilt momentan als ideales Wandmaterial mit direktem Plasmakontakt (Plasma-Facing-Material, PFM) für diese Beanspruchungen. Unterhalb des PFM muss die Wärme möglichst effizient in das Kühlmedium übertragen werden. Im zukünftigen Experimentalreaktor ITER wird dafür eine Kupferlegierung (CuCrZr) verwendet, welche eine hohe Wärmeleitfähigkeit besitzt und für Temperaturen von bis zu 350°C unter fusionsrelevanten Bedingungen einsetzbar ist. In dieser Konfiguration kann ITER mit einer Kühlmitteltemperatur von 150°C betrieben werden. Zur kommerziellen Energiegewinnung ist dies unzureichend, da die thermische Effizienz durch eine deutliche Anhebung der Kühlmitteltemperatur verbessert werden muss. Wird der konventionelle Ansatz einer Wasserkühlung zu Grunde gelegt, ist das Ziel die Kühlmitteltemperatur auf mindestens 300°C anzuheben. In der Folge ist CuCrZr als Wärmesenkenmaterial nicht mehr einsetzbar, da verstärkte Alterung und Festigkeitsverlust im Material auftritt. Zusätzlich vergrößern sich die thermisch induzierten Spannungen in der Komponente mit höheren Temperaturen, durch unterschiedlich große thermische Ausdehnungskoeffizienten der beteiligten Materialien. Für höhere Temperaturen stellt faserverstärktes Kupfer eine mögliche Alternative dar. Die Kombination der hohen Wärmeleitfähigkeit der Kupfermatrix mit der hohen Steifigkeit und Festigkeit von Siliziumcarbidfasern soll die nötigen thermischen und mechanischen Eigenschaften des Wärmesenkenmaterials auch für Temperaturen über 350°C gewährleisten. Im Rahmen dieser Arbeit wurden zwei unterschiedlich hergestellte SiC-Verstärkungsfasertypen hinsichtlich ihrer Eignung für die Herstellung eines Kupfer-Matrix-Komposits (CuMMC) untersucht. Die Zielstellung für das CuMMC beinhaltet eine Festigkeit von 300 MPa bei 300°C sowie eine möglichst hohe Wärmeleitfähigkeit von über 200 W m-1 K-1. Beide Parameter werden stark von der Faserfestigkeit und der Anbindung zwischen Faser und Matrix beeinflusst. Die Wärmeleitfähigkeit durch das CuMMC wird von der Kupfermatrix dominiert, wodurch geringere Faservolumenanteile von Vorteil sind. Höhere Faserfestigkeit erfordert geringere Faseranteile zum Erreichen mechanischer Vorgaben, womit die erzielbare Wärmeleitfähigkeit des CuMMCs steigt. Die Faserfestigkeit wird durch Einzel-Faser- Zugversuche validiert. Darüber hinaus ist die Anbindung zwischen Faser und Matrix essentiell, um die optimale Verstärkungswirkung durch die Fasern im CuMMC zu erzielen. Zur Faser-Matrix-Anbindung werden für jeden Fasertyp unterschiedliche Zwischenschichtsysteme verwendet, die anschließend durch Einzelfaser-Push-Out-Versuche validiert werden. Sind die Voraussetzungen von Faserfestigkeit und Anbindung für einen Fasertyp erfüllt, wird dieser für die Herstellung eines unidirektional verstärkten CuMMCs verwendet, welches bezüglich seiner mechanischen und thermischen Eigenschaften charakterisiert wird. Die mechanische Charakterisierung des CuMMCs erfolgt durch Zugversuche und dehnungsgeregelte, zyklische Versuche, wobei der Fokus neben der Festigkeit auf der Plastifizierung, Verfestigung und Schädigung innerhalb des CuMMCs liegt. Die thermische Charakterisierung erfolgt anhand der Wärmeleitfähigkeitsbestimmung sowohl parallel, als auch transversal zur Faserrichtung. Die mechanischen und thermischen Eigenschaften werden in Abhängigkeit von Faservolumenanteil und Temperatur untersucht. Um den Einfluss von längeren Betriebsphasen unter hoher thermischer Belastung analysieren zu können, wird das CuMMC bei 550°C für 400 h ausgelagert und anschließend wiederum mittels Vergleich seiner mechanischen und thermischen Eigenschaften auf mögliche Schädigungen untersucht. Zur Begutachtung von Schliff- und Bruchflächen zur Schadensanalyse stehen als bildgebende Untersuchungsmethoden neben Lichtmikroskopen ebenso Rasterelektronenmikroskope (REM) zur Verfügung. / The wall materials in future fusion reactors will be operating under extreme thermal and mechanical load conditions. The divertor region of such a device is the most severely loaded component. This part is exposed to heat fluxes of up to 15 MW m-² due to the impinging plasma particle flux. Tungsten is currently considered as the best choice for the plasmafacing- materials (PFM) in the divertor region. An efficient heat sink material is required underneath the PFM for sufficient heat transfer to the cooling channels. In the research reactor ITER a copper alloy (CuCrZr) is foreseen as heat sink material, which is able to withstand temperatures of up to 350°C, corresponding to a water coolant temperature of 150°C. For the commercial use of fusion energy an increase of the thermal efficiency is necessary by increasing the coolant temperature to over 300°C. This will cause higher stresses in the connection area between PFM and the heat sink due to different coefficients of thermal expansion combined with higher temperatures. The mechanical properties of CuCrZr are insufficient for these conditions and fibre reinforced copper metal matrix composites (CuMMC) are considered as an alternative material to strengthen the critical connection area between the heat sink and the PFM. The composite should combine the high heat conductivity of a copper matrix with the high stiffness and mechanical strength of silicon-carbide fibres (SiC-fibres). During this investigation SiC-fibres of two different production principles were studied regarding their usage for the manufacturing of a CuMMC. The main goals for the CuMMC are a tensile strength of 300 MPa combined with a heat conductivity of more than 200 W m-1 K-1. Both of these parameters are affected by the single fibre tensile strength and by the bonding between the fibres and the copper matrix. The achievable heat conductivity in the CuMMC depends on the fibre volume ratio within the composite. Higher fibre strength reduces the necessary fibre volume ratio and hence increases the heat conductivity of the CuMMC. The fibre strength was validated by single fibre tension tests. Furthermore, a good bonding between fibre and matrix is necessary to optimize the fibre reinforcement, which is based on load transfer between fibre and matrix. Therefore, both fibre types were coated with interlayer systems and the effectiveness of the bonding was validated by single fibre push-outtests. For those cases where fibre strength and bonding were sufficient, a unidirectional fibre reinforced CuMMC was manufactured, who’s mechanical and thermal properties were then characterised. The mechanical tests included tensile tests and strain-controlled cycling tests which gave information about strength, plasticity, hardening and the effect of damage within the CuMMC. To verify that the CuMMC heat sink material achieves the thermal requirements, heat conductivity measurements parallel and perpendicular to the fibre direction were performed. These characterizations were done as a function of fibre volume fraction in the CuMMC and temperature. To investigate the influence of long term exposure to operation temperatures, a heat treatment was carried out for 400 h at 550°C and the mechanical and thermal properties were compared to their initial values. Different optical microscopes and scanning electron microscopes (REM) were used for the analysis of crack surfaces and grindings. For the engineering design of divertor components numerical models of the used material are required. These models need to be developed by adjusting their input parameters to fit experimental results. To that end, strain-controlled cycling tests allowed the analysis of the copper matrix hardening behaviour. This is necessary to understand stress development during operational load cycles of the CuMMC. The comparison of room temperature tests with 300°C tests showed the effects of fabrication-induced residual stress in the CuMMC.
2

Foam accumulators: packaging and weight reduction for mobile applications

Rexer, Manuel, Kloft, Peter, Bauer, Frank, Hartig, Jakob, Pelz, Peter F. 25 June 2020 (has links)
Standardized parts like hydraulic accumulators are used in nearly every hydraulic system, in many cases even several. Therefore, even small changes in size and weight of accumulators can save considerable material costs. In mobile applications, hydraulic accumulators are used among others in hydro-pneumatic suspension systems. There is a strong focus on miniaturization and weight reduction, as the components always have to be transported with the vehicle. Energy density and energy content of conventional hydraulic accumulators cannot be maximized at the same time. This limitation can be overcome by adding a heat capacity with large surface into the gas volume of the accumulator. The heat capacity enlarges the isothermal frequency range and therefore enlarges the energy density of the accumulator at the given frequency and the given size. In this paper an experimental comparison of conventional hydraulic accumulators and accumulators with foam inserts shows, that at a specific frequency band, the stiffness of foam filled accumulators is significantly lower than of conventional accumulators. The energy density is about 11 % higher than in conventional accumulators. Consequently, a space reduction of about 18 % is possible.

Page generated in 0.0281 seconds