• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Implementação do método k0-INAA no laboratório de análise por ativação com nêutrons do IPEN utilizando o programa k0-IAEA. Aplicação à análise de amostras geológicas / k0-NAA implementation and application at IPEN neutron activation laboratory by using the k0-IAEA software. Application to geological sample analysis

Mariano, Davi Brigatto 01 February 2012 (has links)
O Laboratório de Análise por Ativação com Nêutrons (LAN-IPEN) vem analisando amostras geológicas, tais como rochas, solos e sedimentos, há vários anos, empregando o método de análise por ativação com nêutrons comparativa, visando estudos geoquímicos e ambientais. Este trabalho apresenta os resultados obtidos na implementação do método de padronização k0-INAA no LANIPEN, para a análise de amostras geológicas, utilizando o programa k0-IAEA, fornecido pela Agência Internacional de Energia Atômica (IAEA). A razão do fluxo de nêutrons térmico-epitérmico f e o fator &alpha; da distribuição de fluxo de nêutrons epitérmicos do reator IEA-R1 do IPEN foram determinados na estação pneumática de irradiação, e em uma posição de irradiação selecionada, para irradiações curtas e longas, respectivamente. Para obter esses fatores, foi utilizado o chamado método bare triple-monitor com 197Au-96Zr-94Zr. Para avaliar a exatidão e precisão do método, foram analisados os materiais geológicos de referência basalto JB-1 (GSJ) e BE-N (IWG-GIT), andesito AGV-1 (USGS), granito GS-N (ANRT), SOIL-7 (IAEA) e sedimento Buffalo River Sediment (NIST BRS-8704), que representam diferentes matrizes geológicas. Os resultados obtidos para até 30 elementos concordaram com os valores recomendados, com erros relativos (bias) menores que 10%, exceto no caso do Zn no AGV-1 (11,4%) e Mg no GS-N (13,4%). Os critérios estatísticos z-score, zeta-score e U-score foram aplicados para avaliação dos resultados. Pelo critério do z-score, os resultados obtidos puderam ser considerados satisfatórios (z<2), com exceção dos resultados obtidos para Mg no GS-N e no JB-1, e para Yb no Soil-7. O critério estatístico zeta-score se mostrou o mais restritivo, obtendo-se resultados questionáveis (2 < zeta < 3) para Mg no BE-N, Mn no GS-N e Yb no Soil-7, e resultados insatisfatórios (zeta>3) para Mn no BE-N, Mg, Ce e La no GS-N, Mg no JB-1, e Th e Eu no Buffalo River Sediment. Os valores de U-score mostraram que todos os resultados, com exceção do valor para Mg no JB-1, estão dentro de um intervalo de confiança de 95% (se for considerado 1,96 o valor limite para o Uteste para um nível de probabilidade de 95%). Estes resultados indicam excelentes possibilidades para o uso deste método paramétrico no LAN-IPEN para a análise de amostras geológicas em estudos geoquímicos e ambientais. / The Neutron Activation Analysis Laboratory (LAN-IPEN) has been analysing geological samples such as rocks, soils and sediments, for many years with the INAA comparative method, for geochemical and environmental research. This study presents the results obtained in the implementation of the k0-standardization method at LANIPEN, for geological sample analysis, by using the program k0- IAEA, provided by the International Atomic Energy Agency (IAEA). The thermal to epithermal flux ratio f and the shape factor &alpha; of the epithermal flux distribution of the IPEN IEA-R1 nuclear reactor were determined for the pneumatic irradiation facility and one selected irradiation position, for short and long irradiations, respectively. To obtain these factors, the bare triple-monitor method with 197Au- 96Zr-94Zr was used. In order to validate the methodology, the geological reference materials basalts JB-1 (GSJ) and BE-N (IWG-GIT), andesite AGV-1 (USGS), granite GS-N (ANRT), SOIL-7 (IAEA) and sediment Buffalo River Sediment (NISTBRS-8704), which represent different geological matrices, were analysed. The concentration results obtained agreed with assigned values, with bias less than 10% except for Zn in AGV-1 (11.4%) and Mg in GS-N (13.4%). Three different scores were used to evaluate the results: z-score, zeta-score and Uscore. The z-score showed that the results can be considered satisfactory (z<2), except for Mg in GS-N and JB-1, and for Yb in Soil-7. Zeta-score was the most restrictive criterion, indicating questionable results (2 < zeta < 3) for Mg in BE-N, Mn in GS-N and Yb in Soil-7, and unsatisfactory results (zeta>3) for Mn in BE-N, Mg, Ce and La in GS-N, Mg in JB-1, and Th and Eu in Buffalo River Sediment. The U-score test showed that all results, except Mg in JB-1, were within 95% confidence interval. These results indicate excellent possibilities of using this parametric method at the LAN-IPEN for geological samples analysis in geochemical and environmental studies.
2

Implementação do método k0-INAA no laboratório de análise por ativação com nêutrons do IPEN utilizando o programa k0-IAEA. Aplicação à análise de amostras geológicas / k0-NAA implementation and application at IPEN neutron activation laboratory by using the k0-IAEA software. Application to geological sample analysis

Davi Brigatto Mariano 01 February 2012 (has links)
O Laboratório de Análise por Ativação com Nêutrons (LAN-IPEN) vem analisando amostras geológicas, tais como rochas, solos e sedimentos, há vários anos, empregando o método de análise por ativação com nêutrons comparativa, visando estudos geoquímicos e ambientais. Este trabalho apresenta os resultados obtidos na implementação do método de padronização k0-INAA no LANIPEN, para a análise de amostras geológicas, utilizando o programa k0-IAEA, fornecido pela Agência Internacional de Energia Atômica (IAEA). A razão do fluxo de nêutrons térmico-epitérmico f e o fator &alpha; da distribuição de fluxo de nêutrons epitérmicos do reator IEA-R1 do IPEN foram determinados na estação pneumática de irradiação, e em uma posição de irradiação selecionada, para irradiações curtas e longas, respectivamente. Para obter esses fatores, foi utilizado o chamado método bare triple-monitor com 197Au-96Zr-94Zr. Para avaliar a exatidão e precisão do método, foram analisados os materiais geológicos de referência basalto JB-1 (GSJ) e BE-N (IWG-GIT), andesito AGV-1 (USGS), granito GS-N (ANRT), SOIL-7 (IAEA) e sedimento Buffalo River Sediment (NIST BRS-8704), que representam diferentes matrizes geológicas. Os resultados obtidos para até 30 elementos concordaram com os valores recomendados, com erros relativos (bias) menores que 10%, exceto no caso do Zn no AGV-1 (11,4%) e Mg no GS-N (13,4%). Os critérios estatísticos z-score, zeta-score e U-score foram aplicados para avaliação dos resultados. Pelo critério do z-score, os resultados obtidos puderam ser considerados satisfatórios (z<2), com exceção dos resultados obtidos para Mg no GS-N e no JB-1, e para Yb no Soil-7. O critério estatístico zeta-score se mostrou o mais restritivo, obtendo-se resultados questionáveis (2 < zeta < 3) para Mg no BE-N, Mn no GS-N e Yb no Soil-7, e resultados insatisfatórios (zeta>3) para Mn no BE-N, Mg, Ce e La no GS-N, Mg no JB-1, e Th e Eu no Buffalo River Sediment. Os valores de U-score mostraram que todos os resultados, com exceção do valor para Mg no JB-1, estão dentro de um intervalo de confiança de 95% (se for considerado 1,96 o valor limite para o Uteste para um nível de probabilidade de 95%). Estes resultados indicam excelentes possibilidades para o uso deste método paramétrico no LAN-IPEN para a análise de amostras geológicas em estudos geoquímicos e ambientais. / The Neutron Activation Analysis Laboratory (LAN-IPEN) has been analysing geological samples such as rocks, soils and sediments, for many years with the INAA comparative method, for geochemical and environmental research. This study presents the results obtained in the implementation of the k0-standardization method at LANIPEN, for geological sample analysis, by using the program k0- IAEA, provided by the International Atomic Energy Agency (IAEA). The thermal to epithermal flux ratio f and the shape factor &alpha; of the epithermal flux distribution of the IPEN IEA-R1 nuclear reactor were determined for the pneumatic irradiation facility and one selected irradiation position, for short and long irradiations, respectively. To obtain these factors, the bare triple-monitor method with 197Au- 96Zr-94Zr was used. In order to validate the methodology, the geological reference materials basalts JB-1 (GSJ) and BE-N (IWG-GIT), andesite AGV-1 (USGS), granite GS-N (ANRT), SOIL-7 (IAEA) and sediment Buffalo River Sediment (NISTBRS-8704), which represent different geological matrices, were analysed. The concentration results obtained agreed with assigned values, with bias less than 10% except for Zn in AGV-1 (11.4%) and Mg in GS-N (13.4%). Three different scores were used to evaluate the results: z-score, zeta-score and Uscore. The z-score showed that the results can be considered satisfactory (z<2), except for Mg in GS-N and JB-1, and for Yb in Soil-7. Zeta-score was the most restrictive criterion, indicating questionable results (2 < zeta < 3) for Mg in BE-N, Mn in GS-N and Yb in Soil-7, and unsatisfactory results (zeta>3) for Mn in BE-N, Mg, Ce and La in GS-N, Mg in JB-1, and Th and Eu in Buffalo River Sediment. The U-score test showed that all results, except Mg in JB-1, were within 95% confidence interval. These results indicate excellent possibilities of using this parametric method at the LAN-IPEN for geological samples analysis in geochemical and environmental studies.
3

Aplicação do método k0-INAA no Laboratório de Análise por Ativação com Nêutrons do IPEN utilizando o programa k0-IAEA. Análise de amostras biológicas. / k0-INAA application at IPEN Neutron Activation Laboratory by using the k0-IAEA program. Biological sample analysis

Daniel Correa Puerta 14 June 2013 (has links)
Este estudo apresenta os resultados obtidos na aplicação do método de padronização k0-INAA no LANIPEN, para a análise de amostras biológicas, utilizando o programa k0-IAEA, fornecido pela Agência Internacional de Energia Atômica (IAEA). Os parâmetros de fluxo f e &alpha; do reator IEA-R1 do IPEN foram determinados na estação pneumática de irradiação e na posição de irradiação 24B/prateleira2, para irradiações curtas e longas, respectivamente. Para obter esses fatores, foi utilizado o chamado método bare triple-monitor com 197Au-96Zr- 94Zr. Para a verificação da precisão e exatidão do método, foram analisados os materiais biológicos de referência Peach Leaves (NIST SRM 1547), Mixed Polish Herbs (INCT-MPH-2) e Tomato Leaves (NIST SRM 1573a). Os critérios estatísticos Erro Relativo (bias, %), Coeficiente de Variação (CV) e U-score foram aplicados para avaliação dos resultados obtidos (média de seis replicatas). Os erros relativos (bias, %) ficaram, para maioria dos elementos, entre 0 e 30%, em relação aos valores certificados. Os Coeficientes de Variação foram inferiores a 20%, mostrando boa reprodutibilidade nos resultados obtidos experimentalmente. Os valores de U-score mostraram que todos os resultados, com exceção do valor para Na no Peach Leaves e no Tomato Leaves, estão dentro de um intervalo de confiança de 95%. Estes resultados apontam para uma promissora utilização do método k0-INAA no LAN-IPEN para a análise de amostras biológicas. / The results obtained in the application of the k0-standardization method at LAN-IPEN for biological matrices analysis, by using the k0-IAEA software, provided by the International Atomic Energy Agency (IAEA), are presented. The flux parameters f and &alpha; of the IEA-R1 reactor were determined for the pneumatic irradiation facility and for one selected irradiation position, 24B/shelf2, for short and long irradiations, respectively. In order to obtain these parameters, the bare triple-monitor method with 197Au-96Zr-94Zr was used. In order to evaluate the accuracy and precision of the methodology, the biological reference materials Peach Leaves (NIST SRM 1547), Mixed Polish Herbs (INCT-MPH-2) e Tomato Leaves (NIST SRM 1573a) were analyzed. The statistical criteria Relative Errors (bias, %), Coefficient of Variation (CV) and U-score were applied to the obtained results (mean of six replicates). The relative errors (bias, %) in relation to certified values, were, for most elements, in the range of 0 e 30. The Coefficients of Variation were below 20%, showing a good reproducibility of the results. The Uscore test showed that all results, except Na in Peach Leaves and in Tomato Leaves, were within 95% confidence interval. These results point out to a promising use of the k0-INAA method at LAN-IPEN for biological sample analysis.
4

Aplicação do método k0-INAA no Laboratório de Análise por Ativação com Nêutrons do IPEN utilizando o programa k0-IAEA. Análise de amostras biológicas. / k0-INAA application at IPEN Neutron Activation Laboratory by using the k0-IAEA program. Biological sample analysis

Puerta, Daniel Correa 14 June 2013 (has links)
Este estudo apresenta os resultados obtidos na aplicação do método de padronização k0-INAA no LANIPEN, para a análise de amostras biológicas, utilizando o programa k0-IAEA, fornecido pela Agência Internacional de Energia Atômica (IAEA). Os parâmetros de fluxo f e &alpha; do reator IEA-R1 do IPEN foram determinados na estação pneumática de irradiação e na posição de irradiação 24B/prateleira2, para irradiações curtas e longas, respectivamente. Para obter esses fatores, foi utilizado o chamado método bare triple-monitor com 197Au-96Zr- 94Zr. Para a verificação da precisão e exatidão do método, foram analisados os materiais biológicos de referência Peach Leaves (NIST SRM 1547), Mixed Polish Herbs (INCT-MPH-2) e Tomato Leaves (NIST SRM 1573a). Os critérios estatísticos Erro Relativo (bias, %), Coeficiente de Variação (CV) e U-score foram aplicados para avaliação dos resultados obtidos (média de seis replicatas). Os erros relativos (bias, %) ficaram, para maioria dos elementos, entre 0 e 30%, em relação aos valores certificados. Os Coeficientes de Variação foram inferiores a 20%, mostrando boa reprodutibilidade nos resultados obtidos experimentalmente. Os valores de U-score mostraram que todos os resultados, com exceção do valor para Na no Peach Leaves e no Tomato Leaves, estão dentro de um intervalo de confiança de 95%. Estes resultados apontam para uma promissora utilização do método k0-INAA no LAN-IPEN para a análise de amostras biológicas. / The results obtained in the application of the k0-standardization method at LAN-IPEN for biological matrices analysis, by using the k0-IAEA software, provided by the International Atomic Energy Agency (IAEA), are presented. The flux parameters f and &alpha; of the IEA-R1 reactor were determined for the pneumatic irradiation facility and for one selected irradiation position, 24B/shelf2, for short and long irradiations, respectively. In order to obtain these parameters, the bare triple-monitor method with 197Au-96Zr-94Zr was used. In order to evaluate the accuracy and precision of the methodology, the biological reference materials Peach Leaves (NIST SRM 1547), Mixed Polish Herbs (INCT-MPH-2) e Tomato Leaves (NIST SRM 1573a) were analyzed. The statistical criteria Relative Errors (bias, %), Coefficient of Variation (CV) and U-score were applied to the obtained results (mean of six replicates). The relative errors (bias, %) in relation to certified values, were, for most elements, in the range of 0 e 30. The Coefficients of Variation were below 20%, showing a good reproducibility of the results. The Uscore test showed that all results, except Na in Peach Leaves and in Tomato Leaves, were within 95% confidence interval. These results point out to a promising use of the k0-INAA method at LAN-IPEN for biological sample analysis.

Page generated in 0.0142 seconds