• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Využití core-shell kolon pro stanovení flukonazolu / Using of core-shell columns for fluconazole determination

Brokešová, Kateřina January 2014 (has links)
Charles University in Prague Faculty of Pharmacy in Hradec Králové Department of Biophysics and Physical Chemistry Candidate: Kateřina Brokešová Supervisor: Ing. Martin Drastík, Ph. D. Thesis title: The use of core-shell columns for fluconazole determination A novel HPLC method for determination of fluconazole in dissolution test samples was developed and partly validated. A matrix formed by lactic and glycolic acid copolymer branched by different compounds was used as a drug carrier. Fluconazol was incorporated as the model drug. The concentration profile of fluconazole was studied by developed HPLC method during the dissolution test. A modern core-shell column Ascentis Express RP-Amide, 10 cm × 3.0 mm; 2.7 μm was employed. A mixture of acetate buffer pH 5.0:methanol (80:20) served as the mobile phase. The flow rate was 0.70 ml/min and the detection wavelength was 260 nm. The temperature of analysis was 50 řC. The retention time of fluconazole was 3.3 min and the whole analysis took just 4 min. Keywords: fluconazole, core-shell column, HPLC, PLGA
2

Zjednodušení HPLC analýzy terbinafinu ve vzorcích na bázi biodegradabilních polyesterů / Simplification of terbinafine HPLC analysis of samples based on biodegradable polyesters

Malovaná, Andrea January 2016 (has links)
Charles University in Prague Faculty of Pharmacy in Hradec Králové Department of Biophysics and Physical Chemistry Candidate: Andrea Malovaná Supervisor: Ing. Martin Drastík, Ph. D. Diploma thesis: Simplification of terbinafine HPLC analysis of samples based on biodegradable polyesters A HPLC method for determination of terbinafine in samples consisting of copolymers of lactic and glycolic acid was optimized and validated. The development of the method was based on the finding of suitable chromatographic conditions for separation of terbinafine. The separation was performed on the Ascentis Express ES-CN, 15 cm × 4.6 mm; 2.7 μm core- shell column. The mixture of the citrate phosphate buffer pH 4 and acetonitrile in ratio 40:60 (v/v) was chosen as the mobile phase. The mobile phase flow rate was set to 1.4 ml/min and the temperature to 30 řC. The injection volume of samples containing terbinafine was 5 µl. The UV detection at 226 nm was employed. The retention time of terbinafine was 3.3 min. The whole analysis was completed within 4 min. The method was validated, following parameters were tested: column efficiency, factor of symmetry, LOD, LOQ, linearity, repeatability and robustness. Keywords: terbinafine, HPLC, core-shell column, PLGA
3

Využití core-shell kolon pro stanovení mikonazolu / Using of core-shell columns for miconazole determination

Hloušková, Martina January 2015 (has links)
BSc. Martina Hloušková Supervisor: Ing. Martin Drastík, Ph.D. The aim of this diploma thesis was the optimization and validation of a HPLC method for miconazole determination in samples supplied by the Department of Pharmaceutical Technology. A gradual miconazole release dependent on the composition of the copolymere of glycolic and lactic acid was studied. HPLC analysis was performed using a modern core-shell Column Ascentis Express RP- Amide, 10 cm x 3.0 mm; 2.7 μm. Optimized analytical conditions were: mobile phase methanol:water 70:30, flow rate 0.8 ml/min, temperature 45 řC, injection 5 l and UV detection at 220 nm. Miconazole retention time was 5.65 min. The entire analysis was carried out in 7 minutes. When the optimal conditions of analysis were determined, the method could be validated. The following parameters were monitored during validation: linearity, selectivity, efficiency, LOD, LOQ, repeatability and tailing factor. All of the monitored parameters met the requirements of the Czech Pharmacopoeia.
4

Stanovení steviových glykosidů metodou HPLC / Determination of steviol glycosides by HPLC

Hollá, Marcela January 2017 (has links)
Charles University Faculty of Pharmacy in Hradec Králové Department of Biophysics and Physical Chemistry Candidate: Marcela Hollá Supervisor: Ing. Martin Drastík, Ph.D. Title of Diploma Thesis: Determination of steviol glycosides by HPLC A new HPLC method was developed and validated for simultaneous detemination of major steviol glycosides stevioside and rebaudioside A in food supplements. Separation took place in hydrophilic interaction chromatography mode on column with core-shell particles. The method was aplicated on analysis of steviol glycosides in products Valosun, SlaDIA, Solia and extract from dried stevia leaves. Isocratic separation was performed using Kinetex 2,6u HILIC 100A, (100 x 2,1 mm; 2,6 µm), Phenomenex analytical column with mobile phase consisted of acetonitrile/0,05 M ammonium formate adjusted with formic acid to pH=3 in ratio 90:10, with flow rate 0,7 ml/min, column temperature set at 30 řC, pressure 19,8 MPa, UV detection at 203 nm and injection volume 1 µl. We compared the results of the analyzes with content of stevioside glycosides declared by the manufacturer. The new developed method allows rapid analysis of food supplements and plant extract containig steviol glycosides. Key words: steviol glycosides, stevioside, rebaudioside A, Stevia rebaudiana Bertoni, high...
5

Příprava a testování kapilárních monolitických kolon pro hydrofilní interakční chromatografii / Preparation and testing of capillary monolithic columns for hydrophobic interaction chromatography

Vlková, Michaela January 2015 (has links)
In frame work of this diploma thesis, monolithic stationary phases based on hydroxymethylmethacrylate were prepared in fused silica capillaries of 320 μm innerdiameter. Monolithic columns were synthesized by a simple procedure using a polymerization mixture, consisting of a monomer N-(hydroxymethyl) methacrylamide (HMMAA), a croslinking agent ethylene dimethacrylate (EDMA), porogenic solvents butane- 1,4-diol, propane-1-ol and an initiator α,α′-azobisisobutyronitrile (AIBN). Prepared HMMA monolithic columns were utilized for separation of mixtures of biologically active compounds, namely peptides with small number of amino acids. Mechanical strength and specific permeability were determined for selected monolithic columns. Keywords: HPLC, HILIC mechanism, hydroxymethyl methacrylate (HMMA) monolithic columns, amino acid, enkephalins.
6

Aplikace standardu ISA95 na destilační koloně / Application ISA 95 standard to the distillation column

Lesák, Michal January 2017 (has links)
This diploma thesis is about design of implementation of the ISA-95 standard for model of distillation column. The thesis consists of two parts, theoretical part and empiric part. In theoretical part, based on scientific literature there are defined terms about regarding standard ISA-95 in which are described individual models of standard ISA-95. Next chapter of diploma thesis is focused on FactoryTalk Services Platform, in which are introdced applications made by RockWell Automation, which are applied for this standard. Then there is description of distilation and model of distilation column. Last chapter of theoretical part is focused on industrial EtherNet/IP. This chapter blends into empiric part. In the next chapter of empiric part, there is design of implementation of standard ISA-95 using applications made by Rockwell Automation. Next chapter is focused on realization of the desing. Chapter of empiric part evaluates the entire project.

Page generated in 0.0348 seconds