1 |
Effect of lateral confining reinforcement on the ductile behaviour of reinforced concrete columnsTanaka, Hitoshi January 1990 (has links)
This thesis is concerned with the effects of lateral confining reinforcement on the ductile behaviour of reinforced concrete columns. The contents of the chapters are summarized as follows. In Chapter one, the general problems in seismic design are discussed and earthquake design methods based on the ductile design approach are described. Japanese, New Zealand and United States design codes are compared. Finally, the scope of this research project is outlined. In Chapter two, after reviewing previous research on confined concrete, the factors which affect the effectiveness of lateral confinement are discussed. Especially the effects of the yield strength of transverse reinforcement, the compressive strength of plain concrete and the strain gradient in the column section due to bending are discussed based on tests which were conducted by the author et al at Kyoto University and Akashi Technological College, Japan. In the axial compression tests on spirally reinforced concrete cylinders (150 mm in diameter by 300 mm in height), the yield strength of transverse reinforcement and the compressive strength of plain concrete were varied from 161 MPa to 1352 MPa and from 17 MPa to 60 MPa, respectively, as experimental parameters. It is found that, when high strength spirals are used as confining reinforcement, the strength and ductility of the confined core concrete are remarkably enhanced but need to be estimated assuming several failure modes which could occur. These are based on the observations that concrete cylinders with high strength spirals suddenly failed at a concrete compressive strain of 2 to 3.5 % due to explosive crushing of the core concrete between the spiral bars or due to bearing failure of the core concrete immediately beneath the spiral bars, while the concrete cylinders with ordinary strength spirals failed in a gentle manner normally observed. In addition, eccentric loading tests were conducted on concrete columns with 200 mm square section confined by square spirals. It is found that the effectiveness of confining reinforcement is reduced by the presence of the strain gradient along the transverse section of column. In Chapter three, the effectiveness of transverse reinforcement with various types of anchorage details which simplify the fabrication of reinforcing cages are investigated. Eight reinforced concrete columns, with either 400 mm or 550 mm square cross sections, were tested subjected to axial compression loading and cyclic lateral loading which simulated a severe earthquake. The transverse reinforcement consisted of arrangements of square perimeter hoops with 135° end hooks, cross ties with 90° and 135° or 180° end hooks, and 'U' and 'J' shaped cross ties and perimeter hoops with tension splices. Conclusions are reached with regard to the effectiveness of the tested anchorage details in the plastic hinge regions of columns designed for earthquake resistance. In Chapter four, the effectiveness of interlocking spirals as transverse reinforcement is studied. Firstly, the general aspects and the related problems of interlocking spirals to provide adequate ductility in the potential plastic hinge region of columns are discussed, referring to the provisions in the New Zealand code,the CALTRANS (California Transportation Authority) code and other related codes. Secondly, based on those discussions, a design method to securely interlock the spirals is proposed. Thirdly, the effectiveness of interlocking spirals is assessed based on column tests conducted as part of this study. Three columns with interlocking spirals and, for comparison, one rectangular column with rectangular hoopsandcross ties, were tested under cyclic horizontal loading which simulated a severe earthquake. The sections of those columns were 400 mm by 600 mm. In Chapter five, analytical models to investigate the buckling behaviour of longitudinal reinforcement restrained by cross ties with 90° and 135° end hooks and by peripheral hoops are proposed. The analyzed results using the proposed models compare well with the experimental observations described in Chapter three. Using those proposed models, a method to check the effectiveness of cross ties with 90° and 135° end hooks is proposed for practical design purposes. In Chapter six, a theory for the prediction of the ultimate longitudinal compressive concrete strain at the stage of first hoop fracture referred to as the "Energy Balance Theory", which has been developed by Mander, Priestley and Park at University of Canterbury, is introduced. After discussing the problems in the "Energy Balance Theory", a modified theory for the prediction of the ultimate longitudinal compressive concrete strain at the stage of first hoop fracture is proposed. The predictions from the modified theory are found to compare well with previous experimental results.
|
2 |
The influence of vertical reinforcement and lateral confinement on the axial capacity of masonry block wallsPaturova, Anna 28 March 2006
Concrete masonry is a multi-component structural system. In the case of reinforced concrete masonry, the system includes the concrete units, the mortar, the reinforcing steel and the grout fill. Placing vertical steel reinforcing bars in the cores of the concrete units enhances the flexural strength of the wall. The vertical steel, when subjected to compression at moderate strain levels, must be confined to improve its resistance to buckling and to improve the effectiveness of the grout around the reinforcing bar. Based on the well established behaviour of reinforced concrete systems, it seems reasonable to presume that the primary means of enhancing ductility is to provide lateral confining steel at closely-spaced intervals to effectively increase the ultimate compressive strain in the grout. It may be assumed that transverse reinforcement in concrete masonry provides lateral confinement to the core so that the axial compressive strength of the grout is enhanced and the ductility improved. <p>The focus of this study was to investigate the effect of vertical reinforcement and lateral confinement on the axial capacity of short partially grouted concrete masonry walls built in running bond. In order to better understand the structural behaviour of both confined and unconfined concrete masonry, it is important to have some knowledge of the load-displacement behaviour, stress-strain behaviour and failure modes of the masonry walls with different configurations of vertical and lateral reinforcement. <p>An experimental study was performed to investigate the behaviour of partially grouted concrete masonry block walls under axial loading. Three types of test specimens of partially grouted concrete block masonry walls were tested: <p>(1) specimens with a grouted core only; <p>(2) specimens with a grouted core and vertical reinforcement (i.e. no confinement); and <p>(3) specimens with a grouted core, vertical reinforcement and spiral
confinement in the grouted cores. In total, thirty short wall specimens were tested to failure. <p>The structural behaviour of vertically reinforced, laterally confined walls was compared to vertically reinforced, unconfined walls, as well as to unreinforced, unconfined masonry walls. The test results indicated that vertical reinforcement of the grouted core did not have a significant positive effect on the failure modes and strength of the short masonry walls. Due to problems with adequate compaction, the lateral confinement provided by the spiral reinforcement had a slightly negative effect on the compressive strength of concrete masonry walls built in running bond. Vertical reinforcement and lateral confinement of the grouted core had some positive effect on the ductility. From a comparison of the ductility for all three types of specimens it was found that both the vertical reinforcement and lateral confinement of the core had a beneficial influence on the post-peak ductility. <p>In general, similar crack patterns and failure modes were observed in all three types of specimens. Vertical cracks that progressed through the end faces of the concrete blocks and mortar joints, suggesting that the lateral expansion of the grouted core contributed to tensile splitting stresses in walls. All walls failed in a compression-tension stress state, which featured spalling away of the block shells and vertical tensile splitting on the end faces.
|
3 |
The influence of vertical reinforcement and lateral confinement on the axial capacity of masonry block wallsPaturova, Anna 28 March 2006 (has links)
Concrete masonry is a multi-component structural system. In the case of reinforced concrete masonry, the system includes the concrete units, the mortar, the reinforcing steel and the grout fill. Placing vertical steel reinforcing bars in the cores of the concrete units enhances the flexural strength of the wall. The vertical steel, when subjected to compression at moderate strain levels, must be confined to improve its resistance to buckling and to improve the effectiveness of the grout around the reinforcing bar. Based on the well established behaviour of reinforced concrete systems, it seems reasonable to presume that the primary means of enhancing ductility is to provide lateral confining steel at closely-spaced intervals to effectively increase the ultimate compressive strain in the grout. It may be assumed that transverse reinforcement in concrete masonry provides lateral confinement to the core so that the axial compressive strength of the grout is enhanced and the ductility improved. <p>The focus of this study was to investigate the effect of vertical reinforcement and lateral confinement on the axial capacity of short partially grouted concrete masonry walls built in running bond. In order to better understand the structural behaviour of both confined and unconfined concrete masonry, it is important to have some knowledge of the load-displacement behaviour, stress-strain behaviour and failure modes of the masonry walls with different configurations of vertical and lateral reinforcement. <p>An experimental study was performed to investigate the behaviour of partially grouted concrete masonry block walls under axial loading. Three types of test specimens of partially grouted concrete block masonry walls were tested: <p>(1) specimens with a grouted core only; <p>(2) specimens with a grouted core and vertical reinforcement (i.e. no confinement); and <p>(3) specimens with a grouted core, vertical reinforcement and spiral
confinement in the grouted cores. In total, thirty short wall specimens were tested to failure. <p>The structural behaviour of vertically reinforced, laterally confined walls was compared to vertically reinforced, unconfined walls, as well as to unreinforced, unconfined masonry walls. The test results indicated that vertical reinforcement of the grouted core did not have a significant positive effect on the failure modes and strength of the short masonry walls. Due to problems with adequate compaction, the lateral confinement provided by the spiral reinforcement had a slightly negative effect on the compressive strength of concrete masonry walls built in running bond. Vertical reinforcement and lateral confinement of the grouted core had some positive effect on the ductility. From a comparison of the ductility for all three types of specimens it was found that both the vertical reinforcement and lateral confinement of the core had a beneficial influence on the post-peak ductility. <p>In general, similar crack patterns and failure modes were observed in all three types of specimens. Vertical cracks that progressed through the end faces of the concrete blocks and mortar joints, suggesting that the lateral expansion of the grouted core contributed to tensile splitting stresses in walls. All walls failed in a compression-tension stress state, which featured spalling away of the block shells and vertical tensile splitting on the end faces.
|
Page generated in 0.1022 seconds