• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Trends in levonorgestrel intrauterine device placement in adolescents following pelvic laparoscopy for endometriosis

Melero, Marina 02 March 2024 (has links)
Endometriosis is a chronic disease that is thought to potentially begin at menarche and progress through a woman’s reproductive years. Adolescents with endometriosis present with dysmenorrhea and chronic pelvic pain. Endometriosis can be treated with medical and surgical management. Levonorgestrel intrauterine devices (LNG-IUD) are an effective option for medical management in adolescents. The primary objective of this study was to determine the rate of IUD insertion after laparoscopy for endometriosis in adolescents. The secondary objective was to compare the characteristics of the adolescent population with and without an IUD placed at the time of surgery. The medical records of 109 adolescent patients </= 21 years old were retrospectively reviewed for patient demographic information and surgical information. In our cohort, 36% of patients had an IUD placed at the time of laparoscopic surgery for endometriosis. Patients with an IUD placed at the time of surgery had a significantly higher BMI than patients who did not have an IUD placed (p = 0.004). The most reported symptoms were dysmenorrhea (77.1%) and chronic pelvic pain (94.5%). Patients with an IUD placed had higher rates of excision of endometriosis while patients who did not have an IUD placed had higher rates of ablation of endometriosis (p = 0.003, p = 0.05). Dysmenorrhea and pelvic pain are commonly reported by adolescent patients with endometriosis. LNG-IUDs are often placed at time of excision of endometriosis surgery for adolescents and further studies are warranted to see if they are effective in the long term postoperative medical management of adolescents who have completed surgery.
2

O efeito do sistema intra-uterino de levonorgestrel (SIU-LNG) no fluxo das artérias uterinas, volume uterino e espessura endometrial em pacientes com endometriose pélvica: estudo comparativo com o análogo de GNRH (GnRHa) / The effect of System Intrauterine levonorgestrel (LNG-IUS) in the uterine artery flow, volume uterinoe Endometrial thickness in patients with endometriosis Pelvic: comparative study with the GnRH analogue (GnRHa)

Manetta, Luiz Alberto 13 December 2007 (has links)
Objetivos: O objetivo deste estudo foi comparar os índices de Pulsatilidade (IP) e Resistência (IR) das artérias uterinas, o volume uterino e a espessura endometrial após o uso do Sistema Intra-uterino de Levonorgestrel (SIU-LNG) ou do agonista do GnRHa (GnRHa) em pacientes portadoras de endometriose pélvica. Pacientes e métodos: Setenta e nove mulheres voluntárias, com idade entre 18 e 40 anos, foram incluídas neste ensaio clínico comparativo, prospectivo, randomizado e controlado. Dezoito foram eliminadas do estudo baseadas nos critérios de exclusão, As 61 pacientes remanescentes foram divididas em dois grupos: 31 pacientes fizeram parte do grupo SIU-LNG (uma foi excluída antes da inserção por apresentar-se grávida) e 30 fizeram parte do grupo GnRHa. Foram submetidasa exame ultra-sonográfico transvaginal bidimensional no dia em que iniciaram o tratamento (inserção do SIU-LNG ou administração de uma ampola de 3,75 mg de GnRHa por via intra-muscular) e seis meses após, avaliando a espessura endometrial, o volume uterino e os IR e IP das artérias uterinas. Resultados: Ambos tratamentos promoveram redução da espessura endometrial (6.08±3.00mm para 2.70±0.98mm e 6.96±3.82mm para 3.23±2.32mm - média ±SD, grupo SIU-LNG e grupo GnRHa, respectivamente). O volume uterino teve redução no grupo usuário do GnRHa (86.67±28.38cm3 para 55.27±25.52cm3) sem alteração significativa nas usuárias do SIU-LNG (75.77±20.88cm3 para 75.97±26.62cm3). Em relação à ascularização uterina, notamos incremento dos IP das artérias uterinas em ambos os grupos (grupo SIU-LNG: artéria uterina direita de 2.38±0.72 para 2.76±0.99 (média ±SD) e artéria uterina esquerda 2.46±0.70 para 2.87±0.96, e grupo GnRHa: artéria uterina direita 2.04±0.59 para 3.12±0.98 eartéria uterina esquerda 2.24±0.59 para 3.15±0.89). Em relação ao IR das artérias uterinas, observamos incremento no grupo GnRHa em ambas artérias e somente na artéria uterina esquerda no grupo SIU-LNG (grupoSIU-LNG - artéria uterina direita de 0.85±0.08 para 0.88±0.07 e artéria uterina esquerda de 0.86±0.07 para 0.89±0.06, e grupo GnRHa: artéria uterina direita de 0.81±0.07 para 0.93±0.09 e artéria uterina esquerda 0.84±0.06 para 0.93±0.09). No entanto, ao compararmos as diferenças, a elevação foi significativamente maior nas usuárias do GnRHa. Conclusões: Ambos GnRHa e SIU-LNG promoveram redução na espessura endometrial e aumento no IP das artérias uterinas. Houve redução do volume uterino nas usuárias do grupo GnRHa, não se alterando no grupo SIU-LNG. Em relação ao IR, houve incremento em ambas as artérias nas usuárias de GnRHa e somente na artéria uterina esquerda nas usuárias do SIU-LNG. / Objectives:The objective of the present study was to compare the uterine arteries pulsatility index (PI) and resistence index (IR), uterine volume and endometrial thickness changes promoted by the use of the levonorgestrel intrauterine device (LNG-IUD) and the gonadotropin-releasing hormone analogue (GnRHa)in patients with endometriosis. Methods: Seventy nine women aged 18 to 40 years were included in this randomized controlled trial. Eighteen was excluded based on the exclusion criteria. The patients were randomly allocated in two groups: 31 women who used the LNG-IUD (since one became pregnant before insertion and wasexcluded) and 30 who used monthly GnRHa injections. They were submitted to a transvaginal two dimensional ultrasound scan on the day the treatment started and 6 months later, for the evaluation of uterine arteries PI, uterine arteries RI, uterine volume and endometrial thickness. Results: The use of LNG-IUD promoted an ndometrial thickness decrease (6.08±3.00mm to 2.7±0.98mm; mean±SD) as does the use of GnRHa (6.96±3.82mm to 3.23±2.32mm). The uterine volume decreased in the GnRHa group (86.67±28.38cm3to 55.27±25.52cm3), but not in the LNG-IUD group (75.77±20.88cm3 to 75.97±26.62cm3). Uterine arteries PI increased in both groups : Uterine arteries PI: LNG-IUD right uterine arterie 2.38 ± 0.72 to 2.76 ± 0.99 and left uterine arterie 2.46 ± 0.70 to 2.87 ± 0.96, and GnRHa right uterine arterie 2.04 ± 0.59 to 3.12 ± 0.98 and left uterine arterie 2.24±0.59 to 3.15 ± 0.89. Uterine arteries RI increased in both arteries in GnRHa and only in the left uterine arterie in the LNG-IUD :Uterine arteries RI : LNG-IUD right uterine arterie 0.85 ± 0..08 to 0.88 ± 0.07 and left uterine arterie 0.86 ± 0.07 to 0.89 ± 0.06, and GnRHa right uterine arterie 0.81 ± 0.07 to 0.93 ± 0.09 and left uterine arterie 0.84 ± 0.06 to 0.93 ± 0.09 . However, the increase was significant higher in the GnRHa group. Conclusions: Both GnRHa and LNG-IUD promoted an endometrial thickness decrease and an increase in the uterine arteries PI. The uterine volume decreased in women who used GnRHa, but not in those who used LNG-IUD.
3

O efeito do sistema intra-uterino de levonorgestrel (SIU-LNG) no fluxo das artérias uterinas, volume uterino e espessura endometrial em pacientes com endometriose pélvica: estudo comparativo com o análogo de GNRH (GnRHa) / The effect of System Intrauterine levonorgestrel (LNG-IUS) in the uterine artery flow, volume uterinoe Endometrial thickness in patients with endometriosis Pelvic: comparative study with the GnRH analogue (GnRHa)

Luiz Alberto Manetta 13 December 2007 (has links)
Objetivos: O objetivo deste estudo foi comparar os índices de Pulsatilidade (IP) e Resistência (IR) das artérias uterinas, o volume uterino e a espessura endometrial após o uso do Sistema Intra-uterino de Levonorgestrel (SIU-LNG) ou do agonista do GnRHa (GnRHa) em pacientes portadoras de endometriose pélvica. Pacientes e métodos: Setenta e nove mulheres voluntárias, com idade entre 18 e 40 anos, foram incluídas neste ensaio clínico comparativo, prospectivo, randomizado e controlado. Dezoito foram eliminadas do estudo baseadas nos critérios de exclusão, As 61 pacientes remanescentes foram divididas em dois grupos: 31 pacientes fizeram parte do grupo SIU-LNG (uma foi excluída antes da inserção por apresentar-se grávida) e 30 fizeram parte do grupo GnRHa. Foram submetidasa exame ultra-sonográfico transvaginal bidimensional no dia em que iniciaram o tratamento (inserção do SIU-LNG ou administração de uma ampola de 3,75 mg de GnRHa por via intra-muscular) e seis meses após, avaliando a espessura endometrial, o volume uterino e os IR e IP das artérias uterinas. Resultados: Ambos tratamentos promoveram redução da espessura endometrial (6.08±3.00mm para 2.70±0.98mm e 6.96±3.82mm para 3.23±2.32mm - média ±SD, grupo SIU-LNG e grupo GnRHa, respectivamente). O volume uterino teve redução no grupo usuário do GnRHa (86.67±28.38cm3 para 55.27±25.52cm3) sem alteração significativa nas usuárias do SIU-LNG (75.77±20.88cm3 para 75.97±26.62cm3). Em relação à ascularização uterina, notamos incremento dos IP das artérias uterinas em ambos os grupos (grupo SIU-LNG: artéria uterina direita de 2.38±0.72 para 2.76±0.99 (média ±SD) e artéria uterina esquerda 2.46±0.70 para 2.87±0.96, e grupo GnRHa: artéria uterina direita 2.04±0.59 para 3.12±0.98 eartéria uterina esquerda 2.24±0.59 para 3.15±0.89). Em relação ao IR das artérias uterinas, observamos incremento no grupo GnRHa em ambas artérias e somente na artéria uterina esquerda no grupo SIU-LNG (grupoSIU-LNG - artéria uterina direita de 0.85±0.08 para 0.88±0.07 e artéria uterina esquerda de 0.86±0.07 para 0.89±0.06, e grupo GnRHa: artéria uterina direita de 0.81±0.07 para 0.93±0.09 e artéria uterina esquerda 0.84±0.06 para 0.93±0.09). No entanto, ao compararmos as diferenças, a elevação foi significativamente maior nas usuárias do GnRHa. Conclusões: Ambos GnRHa e SIU-LNG promoveram redução na espessura endometrial e aumento no IP das artérias uterinas. Houve redução do volume uterino nas usuárias do grupo GnRHa, não se alterando no grupo SIU-LNG. Em relação ao IR, houve incremento em ambas as artérias nas usuárias de GnRHa e somente na artéria uterina esquerda nas usuárias do SIU-LNG. / Objectives:The objective of the present study was to compare the uterine arteries pulsatility index (PI) and resistence index (IR), uterine volume and endometrial thickness changes promoted by the use of the levonorgestrel intrauterine device (LNG-IUD) and the gonadotropin-releasing hormone analogue (GnRHa)in patients with endometriosis. Methods: Seventy nine women aged 18 to 40 years were included in this randomized controlled trial. Eighteen was excluded based on the exclusion criteria. The patients were randomly allocated in two groups: 31 women who used the LNG-IUD (since one became pregnant before insertion and wasexcluded) and 30 who used monthly GnRHa injections. They were submitted to a transvaginal two dimensional ultrasound scan on the day the treatment started and 6 months later, for the evaluation of uterine arteries PI, uterine arteries RI, uterine volume and endometrial thickness. Results: The use of LNG-IUD promoted an ndometrial thickness decrease (6.08±3.00mm to 2.7±0.98mm; mean±SD) as does the use of GnRHa (6.96±3.82mm to 3.23±2.32mm). The uterine volume decreased in the GnRHa group (86.67±28.38cm3to 55.27±25.52cm3), but not in the LNG-IUD group (75.77±20.88cm3 to 75.97±26.62cm3). Uterine arteries PI increased in both groups : Uterine arteries PI: LNG-IUD right uterine arterie 2.38 ± 0.72 to 2.76 ± 0.99 and left uterine arterie 2.46 ± 0.70 to 2.87 ± 0.96, and GnRHa right uterine arterie 2.04 ± 0.59 to 3.12 ± 0.98 and left uterine arterie 2.24±0.59 to 3.15 ± 0.89. Uterine arteries RI increased in both arteries in GnRHa and only in the left uterine arterie in the LNG-IUD :Uterine arteries RI : LNG-IUD right uterine arterie 0.85 ± 0..08 to 0.88 ± 0.07 and left uterine arterie 0.86 ± 0.07 to 0.89 ± 0.06, and GnRHa right uterine arterie 0.81 ± 0.07 to 0.93 ± 0.09 and left uterine arterie 0.84 ± 0.06 to 0.93 ± 0.09 . However, the increase was significant higher in the GnRHa group. Conclusions: Both GnRHa and LNG-IUD promoted an endometrial thickness decrease and an increase in the uterine arteries PI. The uterine volume decreased in women who used GnRHa, but not in those who used LNG-IUD.

Page generated in 0.1247 seconds