• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Diagnóstico e avaliação de coleta e disposição de lodo de fossa e de tanque séptico em Cuiabá - MT

Ramos, Lediane Léslie Campos 27 February 2014 (has links)
Submitted by Simone Souza (simonecgsouza@hotmail.com) on 2017-10-13T15:14:41Z No. of bitstreams: 1 DISS_2014_Lediane Leslie Campos Ramos.pdf: 3409711 bytes, checksum: 0b979d9b033509b0f053399204bcbcc1 (MD5) / Approved for entry into archive by Jordan (jordanbiblio@gmail.com) on 2017-11-07T10:27:32Z (GMT) No. of bitstreams: 1 DISS_2014_Lediane Leslie Campos Ramos.pdf: 3409711 bytes, checksum: 0b979d9b033509b0f053399204bcbcc1 (MD5) / Made available in DSpace on 2017-11-07T10:27:32Z (GMT). No. of bitstreams: 1 DISS_2014_Lediane Leslie Campos Ramos.pdf: 3409711 bytes, checksum: 0b979d9b033509b0f053399204bcbcc1 (MD5) Previous issue date: 2014-02-27 / Devido a precariedade e a falta de rede pública coletora de esgoto na cidade de Cuiabá é grande a procura por serviços das empresas de limpa fossa, o que torna-se um problema, dado que o lodo gerado pelos sistemas de fossas sépticas comporta concentrações expressivas de nutrientes, matéria orgânica, poluentes inorgânicos e organismos patogênicos. O presente estudo tem como objetivo o diagnostico e avaliação da destinação final do lodo de fossa e de tanque séptico em Cuiabá/MT, e propor medidas de adequação de tratamento. Para isso, foram realizadas entrevistas junto às empresas prestadoras deste serviço, e levantamentos junto à Estação de Tratamento de Esgoto Tijucal (ETE Tijucal). A estação é composta por tratamento preliminar (caixa de areia, gradeamento e calha Parshall), dois reatores UASB, uma lagoa anaeróbia, seguida por duas lagoas facultativas em paralelo, e uma lagoa de maturação. Sua capacidade atual de tratamento é de 50 L/s, mas recebe uma vazão diária de 56,23 L/s. Levantamentos realizados neste trabalho indica que a vazão recebida diariamente pode ser maior que a apresentada pela Empresa responsável pela administração da ETE. Além da quantificação do volume de lodo lançado diariamente foi realizado a caracterização com determinação dos seguintes parâmetros: pH, Temperatura, Alcalinidade, Sólidos totais, Sólidos voláteis totais, Sólidos fixos, Sólidos sedimentáveis, Óleos e graxas, DBO, DQO, Fósforo total, Nitrogênio Kjeldahl. De acordo com o resultado da caracterização e comparação com estudos realizados nesta linha de pesquisa identificou-se um possível sistema de tratamento para o lodo de fossas e tanques sépticos. / Due to insecurity and lack of public collector sewer in the city of Cuiabá is great demand for the services of clean fossa companies, which becomes a problem, since the sludge generated by septic tank systems entails significant concentrations of nutrients, organic matter, inorganic pollutants and pathogenic organisms. The present study aims at the diagnosis and evaluation of the final destination of the sludge pit and septic tank in Cuiabá / MT, and proposes measures of adequacy of treatment. For this survey interviews were held with the companies providing this service, and with the Tijucal Sewage Treatment Station (ETE Tijucal). The station consists of preliminary treatment (sandbox, railing and Parshall), two UASB, anaerobic pond, facultative pond followed by two in parallel, and a maturation pond. Your current treatment capacity is 50 L / s, but receives a daily flow of 56.23 L / s. Surveys conducted in this paper indicates that the daily flow received may be higher than that presented by the company responsible for the management of ETE. Besides quantifying the volume of sludge released daily characterization was carried out by determining the following parameters: pH, temperature, alkalinity, total Total solids, volatile solids, fixed solids, settleable solids, oils and grease, BOD, COD, Total Phosphorus, Nitrogen Kjeldahl. According to the results of the characterization and comparison with studies conducted in this research identified a possible treatment system for the sludge pits and septic tanks.
2

Avaliação de sistemas individuais de disposição de esgotos e das empresas limpa-fossas na Região Metropolitana de Goiânia / Evaluation of individual systems of sanitary sewage disposal and onsite sewage cleaning service companies in the Metropolitan Area of Goiânia

RIOS, Fernanda Posch 26 March 2010 (has links)
Made available in DSpace on 2014-07-29T15:01:52Z (GMT). No. of bitstreams: 1 DISSERTACAO FERNANDA POSCH RIOS.pdf: 1644998 bytes, checksum: 1003a4a31d708046d991020d7c53ee0b (MD5) Previous issue date: 2010-03-26 / The system collects sewage from the city of Goiânia, capital of Goiás state, has more than 2500 km of collection network, which discharges into the sewer interceptors deployed on the banks of major watercourses in the city. About 82% of the population of this capital is serviced with sanitary sewer collection system, which the distance from the reality of the Metropolitan area of Goiânia, constituted the main city, Goiânia, comprising twelve municipal districts: Abadia de Goiás, Aparecida de Goiânia, Aragoiânia, Bela Vista de Goiás, Goianápolis, Goianira, Guapó, Hidrolândia, Nerópolis, Santo Antônio de Goiás, Senador de Goiás and Trindade. The Metropolitan area of Goiânia and the rest of the country lack accurate information about the constructive and maintenance aspects of individual systems of sanitary sewage treatment and sanitary sewage disposal, whether as a septic tank or as an onsite sewage facility. The quality and the number of on-site sewage cleaning service companies, their operational procedures, their workers conditions as well as their equipments are also unknown to people. Considering all that, the present work aims to evaluate the constructive and maintenance aspects of individual systems of sanitary sewage treatment and sanitary sewage disposal as well as to make a diagnosis of the performance of on-site sewage cleaning service companies that serve the Metropolitan area of Goiânia. All this information is essential to set corrective measures, plans and goals in order to minimize the impacts harmful to public health and to the environment as regards to the mud displayed by the on-site sewage cleaning service companies. All of the on-site sewage cleaning service companies that serve the Metropolitan area of Goiânia were identified and visited. As an addition to the useful information, 60 services displayed among different companies were closely watched. It was also determined the average percentage of the monthly treated flow related to the sludge displayed by the on-site sewage cleaning service companies inside the Sewage Treatment Plant of Goiânia. As a result it was verified that the correct use of the septic tank system, which is recommended by NBR 7227/93, is small compared to the house units demand not yet served by the plumbing sewage disposal system. As the users show little knowledge about the aforementioned system, the type of solution most used to sanitary sewage is still the cesspool. Few companies have environmental license, and most of them are classified as micro companies and have been in the market for over five years. Just one company was a market leader throughout 2008 and 2009. All companies have not been taking special care concerning both workers and equipments hygiene. Their truck fleet are in average 30 years old and all of them were adapted to receive the metallic tank and the liquid ring pump. The average month amount of sludge coming from sewage cleaning in the Sewage Treatment Station of Goiânia is small and does not alter the final flow quality. The Sewage Treatment Station of Goiânia daily receives an average of 28 trucks, being Friday the busiest day. Despite all companies are aware of the restrictions imposed by SANEAGO as regards to not receiving material other than sanitary sewage, 44% of them realize the collection, transport and final disposal in alternative places with industrial sludge which are clearly contaminated with chrome. / O sistema de coleta de esgoto sanitário da cidade de Goiânia, capital do estado de Goiás, conta com mais de 2.500 km de rede coletora, que descarrega os esgotos em interceptores implantados às margens dos principais cursos d água da cidade. Cerca de 82% da população dessa capital é atendida com rede coletora de esgoto sanitário, o que a distancia da realidade da Região Metropolitana de Goiânia (RMG), constituída da cidade principal, Goiânia, englobando mais doze municípios: Abadia de Goiás, Aparecida de Goiânia, Aragoiânia, Bela Vista de Goiás, Goianápolis, Goianira, Guapó, Hidrolândia, Nerópolis, Santo Antônio de Goiás, Senador Canedo e Trindade. Em todo o país, não se dispõe de informações precisas sobre os aspectos construtivos e de manutenção dos sistemas individuais de tratamento ou disposição de esgoto sanitário, seja na forma de tanque séptico ou de fossa rudimentar. Também são desconhecidas características qualitativas e quantitativas das empresas limpafossas, os procedimentos operacionais adotados, as condições de trabalho dos operários e dos equipamentos utilizados. Diante disso, o presente trabalho teve o objetivo de avaliar os aspectos construtivos e de manutenção dos sistemas individuais de disposição ou de tratamento de esgotos sanitário e diagnosticar a atuação das empresas limpa-fossas que atendem a RMG. Essas informações são imprescindíveis para o estabelecimento de medidas corretivas, planejamento e metas que venham minimizar os impactos deletérios à saúde pública e ao meio ambiente referentes ao lodo disposto pelas empresas limpa-fossas. A coleta de dados foi feita por meio de visitas in loco e entrevistas com 110 usuários de sistemas individuais de tratamento e disposição de esgotos sanitários distribuídos entre os 13 municípios da RMG. Posteriormente, foram identificadas e visitadas todas as empresas atuantes no ramo de serviços de limpa-fossas na RMG. Para complementação das informações necessárias, foi feito o acompanhamento de 60 atendimentos distribuídos entre todas as empresas. Foi determinado, ainda, o percentual médio da vazão mensal tratada referente ao lodo disposto pelas empresas limpa-fossas na Estação de Tratamento de Esgoto de Goiânia (ETE Goiânia). Como resultado, foi verificado que o uso correto do sistema tanque séptico, recomendado pela NBR 7229/93 é pequeno frente à demanda de domicílios ainda não atendidos por rede coletora de esgotos. A população usuária apresenta pouco conhecimento a respeito do referido sistema e a solução mais usada para a destinação dos esgotos sanitários ainda é a fossa rudimentar. Poucas empresas possuem licença ambiental, a maioria é classificada como microempresa e já atua no mercado por um período superior a 5 (cinco) anos. Uma empresa tem permanecido como líder no mercado da RMG durante o biênio 2008 e 2009. Entre todas as empresas, não há adoção de cuidados específicos com a higiene do trabalhador e com os equipamentos usados. A frota de caminhões apresenta idade média acima de 30 (trinta) anos, e todos eles foram adaptados para receber o tanque metálico e a bomba de anel líquido. O percentual médio mensal de lodo de limpa-fossa disposto na ETE Goiânia é pequeno, e não provoca alteração da qualidade do efluente final. A ETE recebe diariamente uma média de 28 caminhões, sendo a sexta-feira o dia mais movimentado. Apesar de todas as empresas estarem cientes das restrições estabelecidas pela empresa concessionária dos serviços de água e esgoto no Estado de Goiás (SANEAGO), para o recebimento de material com características diferentes de esgoto sanitário, 44% delas assumem a realização de coleta, transporte e disposição final em locais alternativos de lodo industrial, declaradamente contaminado com cromo

Page generated in 0.0574 seconds