Hyperspectral interferometry for single-shot profilometry and depth-resolved displacement field measurementWidjanarko, Taufiq January 2011 (has links)
A new approach to the absolute measurement of two-dimensional optical path differences is presented in this thesis. The method, which incorporates a white light interferometer and a hyperspectral imaging system, is referred to as Hyperspectral Interferometry. A prototype of the Hyperspectral Interferometry (HSI) system has been designed, constructed and tested for two types of measurement: for surface profilometry and for depth-resolved displacement measurement, both of which have been implemented so as to achieve single shot data acquisition. The prototype has been shown to be capable of performing a single-shot 3-D shape measurement of an optically-flat step-height sample, with less than 5% difference from the result obtained by a standard optical (microscope) based method. The HSI prototype has been demonstrated to be able to perform single-shot measurement with an unambiguous 352 (m depth range and a rms measurement error of around 80 nm. The prototype has also been tested to perform measurements on optically rough surfaces. The rms error of these measurements was found to increase to around 4× that of the smooth surface. For the depth-resolved displacement field measurements, an experimental setup was designed and constructed in which a weakly-scattering sample underwent simple compression with a PZT actuator. Depth-resolved displacement fields were reconstructed from pairs of hyperspectral interferograms. However, the experimental results did not show the expected result of linear phase variation with depth. Analysis of several possible causes has been carried out with the most plausible reasons being excessive scattering particle density inside the sample and the possibility of insignificant deformation of the sample due to insufficient physical contact between the transducer and the sample.
|
12 |
Analýza a ověření metody měření indexu lomu vzduchu pro laserovou interferometrii / Analysis and verification of air refractive index measurement method for laser interferometryPikálek, Tomáš January 2016 (has links)
This thesis deals with a theoretical analysis and experimental verification of a new method for the refractive index of air measurement. This method uses a combination of laser and low-coherence interferometry. The experimental setup is based on the Michelson interferometer equipped with a double-spaced glass cell. The optical path difference between the inner and outer part of the cell that is proportional to air refractivity is estimated using two low-coherence interference signals. These signals are analysed in the frequency domain which results in the dependence of the phase change caused the by air on vacuum wavelength. This dependency is fitted by a theoretical function based on Edlén's equations in order to calculate the phase difference for laser wavelength. This value is then made more accurate utilising two laser interference signals and used for the air refractive index calculation. The new method was experimentally verified and compared to two different techniques. Moreover, the measurement uncertainty was evaluated.
|
13 |
Evaluation of the thermal stability of a low-coherence interferometer for precision surface profilometryTaudt, Ch., Baselt, T., Nelsen, B., Assmann, H., Greiner, A., Koch, E., Hartmann, P. 09 August 2019 (has links)
Manufacturing of precise structures in MEMS, semiconductors, optics and other fields requires high standards in manufacturing and quality control. Appropriate surface topography measurement technologies should therefore deliver nm accuracy in the axial dimension under typical industrial conditions. This work shows the characterization of a dispersion-encoded low-coherence interferometer for the purpose of fast and robust surface topography measurements. The key component of the interferometer is an element with known dispersion. This dispersive element delivers a controlled phase variation in relation to the surface height variation which can be detected in the spectral domain. A laboratory setup equipped with a broadband light source (200 - 1100 nm) was established. Experiments have been carried out on a silicon-based standard with height steps of 100 nm under different thermal conditions such as 293.15 K and 303.15 K. Additionally, the stability of the setup was studied over periods of 5 hours (with constant temperature) and 15 hours (with linear increasing temperature). The analyzed data showed that a height measurement of 97.99 ± 4:9nm for 293.15 K and of 101.43 ± 3:3nm for 303.15 K was possible. The time-resolved measurements revealed that the developed setup is highly stable against small thermal uctuations and shows a linear behaviour under increasing thermal load. Calibration data for the mathmatical corrections under different thermal conditions was obtained.
|
14 |
Measurement of surface topographies in the nm-range for power chip technologies by a modified low-coherence interferometerTaudt, Ch., Baselt, T., Nelsen, B., Aßmann, H., Greiner, A., Koch, E., Hartmann, P. 29 August 2019 (has links)
This work introduces a modified low-coherence interferometry approach for nanometer surface-profilometry. The key component of the interferometer is an element with known dispersion which defines the measurement range as well as the resolution. This dispersive element delivers a controlled phase variation which can be detected in the spectral domain and used to reconstruct height differences on a sample. In the chosen setup, both axial resolution and measurement range are tunable by the choice of the dispersive element.
The basic working principle was demonstrated by a laboratory setup equipped with a supercontinuum light source (Δλ = 400 ̶ 1700 nm). Initial experiments were carried out to characterize steps of 101 nm on a silicon height standard. The results showed that the system delivers an accuracy of about 11.8 nm. These measurements also served as a calibration for the second set of measurements. The second experiment consisted of the measurement of the bevel of a silicon wafer. The modified low-coherence interferometer could be utilized to reproduce the slope on the edge within the previously estimated accuracy. The main advantage of the proposed measurement approach is the possibility to collect data without the need for mechanically moving parts.
|
15 |
Two-dimensional low-coherence interferometry for the characterization of nanometer wafer topographiesTaudt, Ch., Baselt, T., Nelsen, B., Aßmann, H., Greiner, A., Koch, E., Hartmann, P. 30 August 2019 (has links)
Within this work a scan-free, low-coherence interferometry approach for surface profilometry with nm-precision is presented. The basic setup consist of a Michelson-type interferometer which is powered by a supercontinuum light-source (Δλ = 400 - 1700 nm). The introduction of an element with known dispersion delivers a controlled phase variation which can be detected in the spectral domain and used to reconstruct height differences on a sample. In order to enable scan-free measurements, the interference signal is spectrally decomposed with a grating and imaged onto a two-dimensional detector. One dimension of this detector records spectral, and therefore height information, while the other dimension stores the spatial position of the corresponding height values.
In experiments on a height standard, it could be shown that the setup is capable of recording multiple height steps of 101 nm over a range of 500 µm with an accuracy of about 11.5 nm. Further experiments on conductive paths of a micro-electro-mechanical systems (MEMS) pressure sensor demonstrated that the approach is also suitable to precisely characterize nanometer-sized structures on production-relevant components. The main advantage of the proposed measurement approach is the possibility to collect precise height information over a line on a surface without the need for scanning. This feature makes it interesting for a production-accompanying metrology.
|