Spelling suggestions: "subject:"m modes""
51 |
Theoretical studies of slow collisions : elastic electron scattering from positive ions, charge transfer in one-electron ion-ion systems and mutual neutralization of Hâ»/Dâ» and Hâºâ‚‚Shepherd, Juliet January 2001 (has links)
No description available.
|
52 |
Monitoração e diagnóstico para detecção de falhas de sensores utilizando a metodologia GMDH / Monitoring and diagnosis for sensor fault detection using GMDH methodologyGonçalves, Iraci Martinez Pereira 16 February 2006 (has links)
O sistema de detecção de falhas e diagnóstico é um sistema de suporte ao operador dedicado a funções específicas que alertam os operadores para problemas de falhas em sensores e atuadores, e auxiliam no diagnóstico antes que os limites normais de alarmes sejam atingidos. Sistemas de suporte ao operador surgiram para diminuir a complexidade dos painéis causada pelo grande aumento de informação disponível nas salas de controle das centrais nucleares. Neste trabalho foi desenvolvido um Sistema de Monitoração e Diagnóstico utilizando a metodologia GMDH (Group Method of Data Handling) aplicado ao reator de pesquisas do Ipen IEA-R1. O sistema faz a monitoração, comparando os valores calculados pelo modelo GMDH com os valores medidos. A metodologia desenvolvida foi aplicada inicialmente em modelos teóricos: um modelo teórico de trocador de calor e um modelo teórico do reator IEA-R1. Os resultados obtidos com os modelos teóricos propiciaram uma base para a aplicação da metodologia aos dados de operação do reator. Para a monitoração de dados de operação foram desenvolvidos três modelos GMDH: o primeiro utilizou apenas variáveis de processo, o segundo modelo foi desenvolvido considerando-se algumas variáveis nucleares e três variáveis de temperatura, e o terceiro modelo GMDH considerou todas as variáveis possíveis. Os três modelos apresentaram resultados excelentes, mostrando amplamente a viabilidade da utilização da metodologia GMDH na monitoração de dados de operação. A comparação entre os resultados dos três modelos desenvolvidos mostrou ainda a capacidade da metodologia GMDH de escolher as melhores variáveis para otimização do modelo. Para a implementação de um sistema de diagnóstico, foram adicionadas falhas sinteticamente aos valores das variáveis de temperatura. Os valores de falhas correspondem a uma descalibração da temperatura e o resultado da monitoração de dados com falhas foi utilizado para a elaboração de um sistema de diagnóstico simples e objetivo baseado na lógica nebulosa. / The fault detection and diagnosis system is an Operator Support System dedicated to specific functions that alerts operators to sensors and actuators fault problems, and guide them in the diagnosis before the normal alarm limits are reached. Operator Support Systems appears to reduce panels complexity caused by the increase of the available information in nuclear power plants control room. In this work a Monitoring and Diagnosis System was developed based on the GMDH (Group Method of Data Handling) methodology. The methodology was applied to the IPEN research reactor IEA-R1. The system performs the monitoring, comparing GMDH model calculated values with measured values. The methodology developed was firstly applied in theoretical models: a heat exchanger model and an IPEN reactor theoretical model. The results obtained with theoretical models gave a base to methodology application to the actual reactor operation data. Three GMDH models were developed for actual operation data monitoring: the first one using just the thermal process variables, the second one was developed considering also some nuclear variables, and the third GMDH model considered all the reactor variables. The three models presented excellent results, showing the methodology utilization viability in monitoring the operation data. The comparison between the three developed models results also shows the methodology capacity to choose by itself the best set of input variables for the model optimization. For the system diagnosis implementation, faults were simulated in the actual temperature variable values by adding a step change. The fault values correspond to a typical temperature descalibration and the result of monitoring faulty data was then used to build a simple diagnosis system based on fuzzy logic.
|
53 |
Monitoração e diagnóstico para detecção de falhas de sensores utilizando a metodologia GMDH / Monitoring and diagnosis for sensor fault detection using GMDH methodologyIraci Martinez Pereira Gonçalves 16 February 2006 (has links)
O sistema de detecção de falhas e diagnóstico é um sistema de suporte ao operador dedicado a funções específicas que alertam os operadores para problemas de falhas em sensores e atuadores, e auxiliam no diagnóstico antes que os limites normais de alarmes sejam atingidos. Sistemas de suporte ao operador surgiram para diminuir a complexidade dos painéis causada pelo grande aumento de informação disponível nas salas de controle das centrais nucleares. Neste trabalho foi desenvolvido um Sistema de Monitoração e Diagnóstico utilizando a metodologia GMDH (Group Method of Data Handling) aplicado ao reator de pesquisas do Ipen IEA-R1. O sistema faz a monitoração, comparando os valores calculados pelo modelo GMDH com os valores medidos. A metodologia desenvolvida foi aplicada inicialmente em modelos teóricos: um modelo teórico de trocador de calor e um modelo teórico do reator IEA-R1. Os resultados obtidos com os modelos teóricos propiciaram uma base para a aplicação da metodologia aos dados de operação do reator. Para a monitoração de dados de operação foram desenvolvidos três modelos GMDH: o primeiro utilizou apenas variáveis de processo, o segundo modelo foi desenvolvido considerando-se algumas variáveis nucleares e três variáveis de temperatura, e o terceiro modelo GMDH considerou todas as variáveis possíveis. Os três modelos apresentaram resultados excelentes, mostrando amplamente a viabilidade da utilização da metodologia GMDH na monitoração de dados de operação. A comparação entre os resultados dos três modelos desenvolvidos mostrou ainda a capacidade da metodologia GMDH de escolher as melhores variáveis para otimização do modelo. Para a implementação de um sistema de diagnóstico, foram adicionadas falhas sinteticamente aos valores das variáveis de temperatura. Os valores de falhas correspondem a uma descalibração da temperatura e o resultado da monitoração de dados com falhas foi utilizado para a elaboração de um sistema de diagnóstico simples e objetivo baseado na lógica nebulosa. / The fault detection and diagnosis system is an Operator Support System dedicated to specific functions that alerts operators to sensors and actuators fault problems, and guide them in the diagnosis before the normal alarm limits are reached. Operator Support Systems appears to reduce panels complexity caused by the increase of the available information in nuclear power plants control room. In this work a Monitoring and Diagnosis System was developed based on the GMDH (Group Method of Data Handling) methodology. The methodology was applied to the IPEN research reactor IEA-R1. The system performs the monitoring, comparing GMDH model calculated values with measured values. The methodology developed was firstly applied in theoretical models: a heat exchanger model and an IPEN reactor theoretical model. The results obtained with theoretical models gave a base to methodology application to the actual reactor operation data. Three GMDH models were developed for actual operation data monitoring: the first one using just the thermal process variables, the second one was developed considering also some nuclear variables, and the third GMDH model considered all the reactor variables. The three models presented excellent results, showing the methodology utilization viability in monitoring the operation data. The comparison between the three developed models results also shows the methodology capacity to choose by itself the best set of input variables for the model optimization. For the system diagnosis implementation, faults were simulated in the actual temperature variable values by adding a step change. The fault values correspond to a typical temperature descalibration and the result of monitoring faulty data was then used to build a simple diagnosis system based on fuzzy logic.
|
54 |
Monitoração e diagnóstico para detecção de falhas de sensores utilizando a metodologia GMDHGONCALVES, IRACI M. P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:37Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
55 |
Caracterização dos campos neutrônicos obtidos por meio de armadilhas de nêutrons a partir da utilização de água pesada (D2O) no interior do núcleo do reator nuclear IPEN/MB-01 / Characterization of the neutronic fields obtained by means of flux traps from heavy water (D2O) inside the core of the IPEN/MB-01 nuclear reactorSANTOS, DIOGO F. dos 23 July 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-07-23T11:04:17Z
No. of bitstreams: 0 / Made available in DSpace on 2015-07-23T11:04:17Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
56 |
Monitoração e diagnóstico para detecção de falhas de sensores utilizando a metodologia GMDHGONCALVES, IRACI M. P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:37Z (GMT). No. of bitstreams: 0 / O sistema de detecção de falhas e diagnóstico é um sistema de suporte ao operador dedicado a funções específicas que alertam os operadores para problemas de falhas em sensores e atuadores, e auxiliam no diagnóstico antes que os limites normais de alarmes sejam atingidos. Sistemas de suporte ao operador surgiram para diminuir a complexidade dos painéis causada pelo grande aumento de informação disponível nas salas de controle das centrais nucleares. Neste trabalho foi desenvolvido um Sistema de Monitoração e Diagnóstico utilizando a metodologia GMDH (Group Method of Data Handling) aplicado ao reator de pesquisas do Ipen IEA-R1. O sistema faz a monitoração, comparando os valores calculados pelo modelo GMDH com os valores medidos. A metodologia desenvolvida foi aplicada inicialmente em modelos teóricos: um modelo teórico de trocador de calor e um modelo teórico do reator IEA-R1. Os resultados obtidos com os modelos teóricos propiciaram uma base para a aplicação da metodologia aos dados de operação do reator. Para a monitoração de dados de operação foram desenvolvidos três modelos GMDH: o primeiro utilizou apenas variáveis de processo, o segundo modelo foi desenvolvido considerando-se algumas variáveis nucleares e três variáveis de temperatura, e o terceiro modelo GMDH considerou todas as variáveis possíveis. Os três modelos apresentaram resultados excelentes, mostrando amplamente a viabilidade da utilização da metodologia GMDH na monitoração de dados de operação. A comparação entre os resultados dos três modelos desenvolvidos mostrou ainda a capacidade da metodologia GMDH de escolher as melhores variáveis para otimização do modelo. Para a implementação de um sistema de diagnóstico, foram adicionadas falhas sinteticamente aos valores das variáveis de temperatura. Os valores de falhas correspondem a uma descalibração da temperatura e o resultado da monitoração de dados com falhas foi utilizado para a elaboração de um sistema de diagnóstico simples e objetivo baseado na lógica nebulosa. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
57 |
Caracterização dos campos neutrônicos obtidos por meio de armadilhas de nêutrons a partir da utilização de água pesada (D2O) no interior do núcleo do reator nuclear IPEN/MB-01 / Characterization of the neutronic fields obtained by means of flux traps from heavy water (D2O) inside the core of the IPEN/MB-01 nuclear reactorSANTOS, DIOGO F. dos 23 July 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-07-23T11:04:17Z
No. of bitstreams: 0 / Made available in DSpace on 2015-07-23T11:04:17Z (GMT). No. of bitstreams: 0 / Os experimentos realizados e apresentados nesta dissertação resultaram na caracterização neutrônica de núcleos na configuração cilíndrica com 30 varetas combustíveis de diâmetro com um espaço, criado pela retirada de 16 varetas centrais, preenchido com água leve (H2O) ou água pesada (D2O) no reator nuclear de pesquisa IPEN/MB-01. Nestes núcleos, efetuou-se experimentos de correlação de canais nucleares, calibração de barras de controle e irradiação de detectores de ativação de diversos materiais em forma de folhas, cujas faixas energéticas de atuação abrangem grande parte do espectro de nêutrons do núcleo do reator, para a obtenção de parâmetros nucleares, como excessos de reatividade, reatividades totais, atividades saturadas por núcleo alvo, razões espectrais, razões de cádmio e fluxo de nêutrons multigrupo. Com a irradiação de fios de ativação de ouro na parte radial foram obtidas as formas espaciais dos fluxos de nêutrons térmicos e epitérmicos. Os resultados mostraram as características espectrais dessa nova configuração com o espaço das 16 varetas combustíveis preenchido com os dois materiais moderadores. No espaço com a água leve houve um aumento significativo de 294% do fluxo de nêutrons térmicos em comparação com a configuração padrão retangular de 28×26 varetas combustíveis. Com a água pesada aumentou-se a reatividade do sistema com ρ = (783 ± 54) pcm a mais de excesso de reatividade que na configuração com água leve. Os resultados calculados foram simulados nos códigos computacionais MCNP5, SANDBP e CITATION, onde se obtiveram resultados acurados e precisos para as atividades saturadas por núcleo alvo, as distribuições energéticas e espaciais dos fluxos de nêutrons da parte ativa e de parte do refletor e as comparações diretas das seções de choque entre as razões espectrais experimentais e calculadas. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
Page generated in 0.049 seconds